Longitudinally implanted intrafascicular electrodes for stimulating and recording fascicular physioelectrical signals in the sciatic nerve of rabbits

Author keywords

[No Author keywords available]

Indexed keywords

AMPLITUDE MODULATION; ANIMAL EXPERIMENT; ARM PROSTHESIS; ARTICLE; CONTROLLED STUDY; ELECTROMYOGRAPHY; ELECTROSTIMULATION; EVOKED MUSCLE RESPONSE; EXPERIMENTAL MODEL; GASTROCNEMIUS MUSCLE; LATENT PERIOD; MUSCLE EXCITATION; NERVE FUNCTION; NERVE TRACT; NONHUMAN; PRIORITY JOURNAL; RECORDING; SCIATIC NERVE; TIBIALIS ANTERIOR MUSCLE;

EID: 0038503570     PISSN: 07381085     EISSN: None     Source Type: Journal    
DOI: 10.1002/micr.10116     Document Type: Article
Times cited : (20)

References (18)
  • 2
    • 0018248287 scopus 로고
    • Clinical application study of multifunctional prosthetic hands
    • Herberts P, Almström C, Caine K. Clinical application study of multifunctional prosthetic hands. J Bone Joint Surg [Br] 1978; 60:552-560.
    • (1978) J Bone Joint Surg [Br] , vol.60 , pp. 552-560
    • Herberts, P.1    Almström, C.2    Caine, K.3
  • 3
    • 0029076241 scopus 로고
    • Prosthetic usage in major upper extremity amputations
    • Wright TW, Hagen AD, Wood MB. Prosthetic usage in major upper extremity amputations. J Hand Surg [Am] 1995;20:619-622.
    • (1995) J Hand Surg [Am] , vol.20 , pp. 619-622
    • Wright, T.W.1    Hagen, A.D.2    Wood, M.B.3
  • 4
    • 0021907009 scopus 로고
    • Electronically powered prostheses for the adult with an upper limb amputation
    • Heger H, Millostein S, Hunter GA. Electronically powered prostheses for the adult with an upper limb amputation. J Bone Joint Surg [Br] 1985;67:278-281.
    • (1985) J Bone Joint Surg [Br] , vol.67 , pp. 278-281
    • Heger, H.1    Millostein, S.2    Hunter, G.A.3
  • 6
    • 0016618733 scopus 로고
    • Clinical application study of externally powered upper limb prosthetics system: The VA elbow, the VA hand, and the VA/NU myoelectric hand system
    • Lewis EA, Sherdos CR, Sowell TT, Houston VL. Clinical application study of externally powered upper limb prosthetics system: the VA elbow, the VA hand, and the VA/NU myoelectric hand system. Bull Prosthet Res 1975;11:51-136.
    • (1975) Bull Prosthet Res , vol.11 , pp. 51-136
    • Lewis, E.A.1    Sherdos, C.R.2    Sowell, T.T.3    Houston, V.L.4
  • 7
    • 0029294523 scopus 로고
    • Neuromuscular stimulation selectivity of multiple-contact nerve cuff electrode arrays
    • Sweeney JD, Crawford NR, Brandon TA. Neuromuscular stimulation selectivity of multiple-contact nerve cuff electrode arrays. Med Biol Eng Comput 1995;33:418-425.
    • (1995) Med Biol Eng Comput , vol.33 , pp. 418-425
    • Sweeney, J.D.1    Crawford, N.R.2    Brandon, T.A.3
  • 10
    • 0028037380 scopus 로고
    • Somatosensory evoked potential evaluation of acute nerve injury associated with external fixation procedures
    • Marina RW, Mauricio RD, Mikhail LS, Welch RD, Birch JG. Somatosensory evoked potential evaluation of acute nerve injury associated with external fixation procedures. Clin Orthop 1994;308:254-263.
    • (1994) Clin Orthop , vol.308 , pp. 254-263
    • Marina, R.W.1    Mauricio, R.D.2    Mikhail, L.S.3    Welch, R.D.4    Birch, J.G.5
  • 11
    • 0031868320 scopus 로고    scopus 로고
    • Protocol for microneurography with xoncentric needle electrodes
    • Hallin RG, Wu G. Protocol for microneurography with xoncentric needle electrodes. Brain Res Brain Res Protoc 1998;2:120-132.
    • (1998) Brain Res Brain Res Protoc , vol.2 , pp. 120-132
    • Hallin, R.G.1    Wu, G.2
  • 12
    • 0024320175 scopus 로고
    • An intrafascicular electrode for recording of action potentials in peripheral nerves
    • Malagodi MS, Horch KW, Schoenberg AA. An intrafascicular electrode for recording of action potentials in peripheral nerves. Ann Biomed Eng 1989;17:397-410.
    • (1989) Ann Biomed Eng , vol.17 , pp. 397-410
    • Malagodi, M.S.1    Horch, K.W.2    Schoenberg, A.A.3
  • 14
    • 0030560821 scopus 로고    scopus 로고
    • Metallized polymer fibers as lead-wires and intrafascicular microelectrodes
    • McNughton TG, Horch KW. Metallized polymer fibers as lead-wires and intrafascicular microelectrodes. J Neurosci Methods 1996;70:103-110.
    • (1996) J Neurosci Methods , vol.70 , pp. 103-110
    • McNughton, T.G.1    Horch, K.W.2
  • 15
    • 0030088097 scopus 로고    scopus 로고
    • Closed-loop control of ankle position using muscle afferent feedback with functional neuromuscular stimulation
    • Yoshida K, Horch K. Closed-loop control of ankle position using muscle afferent feedback with functional neuromuscular stimulation. IEEE Biomed Eng 1996;43:167-176.
    • (1996) IEEE Biomed Eng , vol.43 , pp. 167-176
    • Yoshida, K.1    Horch, K.2
  • 16
    • 0027588996 scopus 로고
    • Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes
    • Yoshida K, Horch K. Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes. IEEE Biomed Eng 1993;40:492-494.
    • (1993) IEEE Biomed Eng , vol.40 , pp. 492-494
    • Yoshida, K.1    Horch, K.2
  • 17
    • 0034001248 scopus 로고    scopus 로고
    • Intrafascicular electrodes for stimulation and recording from mudpuppy spinal roots
    • Yoshida K, Jovanovie K, Richard BS. Intrafascicular electrodes for stimulation and recording from mudpuppy spinal roots. J Neurosci Methods 2000;96:47-55.
    • (2000) J Neurosci Methods , vol.96 , pp. 47-55
    • Yoshida, K.1    Jovanovie, K.2    Richard, B.S.3
  • 18
    • 0034001259 scopus 로고    scopus 로고
    • A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats
    • Branner A, Normann RA. A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats. Brain Res Bull 2000;51:293-306.
    • (2000) Brain Res Bull , vol.51 , pp. 293-306
    • Branner, A.1    Normann, R.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.