메뉴 건너뛰기




Volumn 13, Issue 21, 2005, Pages 8612-8617

CVD diamond alpha-particle detectors with different electrode geometry

Author keywords

[No Author keywords available]

Indexed keywords

ALPHA PARTICLES; DETECTORS; ELECTRIC FIELD EFFECTS; MICROSTRUCTURE; PHOTOCURRENTS; SANDWICH STRUCTURES;

EID: 26844509356     PISSN: None     EISSN: 10944087     Source Type: Journal    
DOI: 10.1364/OPEX.13.008612     Document Type: Article
Times cited : (13)

References (8)
  • 1
    • 0016925287 scopus 로고
    • Diamond dosimeter for X-ray and gamma-radiation
    • Kozlov S. F., et al., “Diamond dosimeter for X-ray and gamma-radiation, ” IEEE Trans. Nucl. Sci. NS-24, 235-237(1976).
    • (1976) IEEE Trans. Nucl. Sci. NS , vol.24 , pp. 235-237
    • Kozlov, S.F.1
  • 2
    • 0018433730 scopus 로고
    • Transport properties of natural diamond used as nuclear particle detector for a wide temperature range
    • Nava F., et al., “Transport properties of natural diamond used as nuclear particle detector for a wide temperature range, ” IEEE Trans. Nucl. Sci. NS-26, 308-315(1979).
    • (1979) IEEE Trans. Nucl. Sci. , vol.26 , pp. 308-315
    • Nava, F.1
  • 3
    • 0030562743 scopus 로고    scopus 로고
    • Field emission characteristics of polycrystalline and single-crystalline diamond grown on Si tips
    • Givargizov E. I., et al., “Field emission characteristics of polycrystalline and single-crystalline diamond grown on Si tips, ” Appl. Surf. Sci. 94-95, 117-112(1996).
    • (1996) Appl. Surf. Sci. , vol.94 , Issue.95 , pp. 112-117
    • Givargizov, E.I.1
  • 4
    • 0027393650 scopus 로고
    • Application of a natural diamond detector for the measurement of relative dose distributions in radiotherapy
    • Vatnitsky S., et al., “Application of a natural diamond detector for the measurement of relative dose distributions in radiotherapy, ” Phys. Med. Biol. 38, 173-184(1993).
    • (1993) Phys. Med. Biol. , vol.38 , pp. 173-184
    • Vatnitsky, S.1
  • 5
    • 0033702161 scopus 로고    scopus 로고
    • Pulse height distribution and radiation tolerance of CVD diamond detectors
    • Adam W., et al., “Pulse height distribution and radiation tolerance of CVD diamond detectors, ” Nucl. Instrum. Methods A 447, 244-250(2000).
    • (2000) Nucl. Instrum. Methods A , vol.447 , pp. 244-250
    • Adam, W.1
  • 6
    • 0006759828 scopus 로고    scopus 로고
    • Systematic study of the normal and pumped state of high efficiency diamond particle detectors grown by chemical vapor deposition
    • Marinelli M., et al., “Systematic study of the normal and pumped state of high efficiency diamond particle detectors grown by chemical vapor deposition, ” J. Appl. Phys. 89, 1430(2001).
    • (2001) J. Appl. Phys. , vol.89 , pp. 1430
    • Marinelli, M.1
  • 7
    • 11144254445 scopus 로고    scopus 로고
    • Effects of the deposition conditions and annealing process on the electric properties of hot-filament CVD diamond films
    • Zhang M. L., et al., “Effects of the deposition conditions and annealing process on the electric properties of hot-filament CVD diamond films, ” J. Crystal Growth 274, 1-27(2005).
    • (2005) J. Crystal Growth , vol.274 , pp. 1-27
    • Zhang, M.L.1
  • 8
    • 0242336742 scopus 로고    scopus 로고
    • Infrared optical properties of diamond films and electrical properties of CVD diamond detectors
    • Wang L. J., et al., “Infrared optical properties of diamond films and electrical properties of CVD diamond detectors, ” J. Phys. D: Appl. Phys. 36, 2548-2552(2003).
    • (2003) J. Phys. D: Appl. Phys. , vol.36 , pp. 2548-2552
    • Wang, L.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.