메뉴 건너뛰기




Volumn 16, Issue 5, 2004, Pages 243-246

A Meta-Analysis of Percutaneous Vascular Closure Devices after Diagnostic Catheterization and Percutaneous Coronary Intervention

Author keywords

Complications; Meta analysis; Vascular sealing devices

Indexed keywords

ARTICLE; CATHETERIZATION; CLINICAL TRIAL; CONFIDENCE INTERVAL; DEVICE; FEMORAL ARTERY; HEMATOMA; HUMAN; INTERMETHOD COMPARISON; MANTEL HAENSZEL TEST; MEDLINE; META ANALYSIS; PERCUTANEOUS CORONARY INTERVENTION; PERCUTANEOUS VASCULAR CLOSURE DEVICE; RISK REDUCTION; SAFETY; SYSTEMATIC REVIEW;

EID: 2442443079     PISSN: 10423931     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (142)

References (27)
  • 1
    • 0033678576 scopus 로고    scopus 로고
    • Femoral hemostasis after transcatheter therapeutic intervention: A prospective randomized study of the Angio-Seal device vs. the Femostop device
    • Amin FR, Yousufuddin M, Stables R, et al. Femoral hemostasis after transcatheter therapeutic intervention: A prospective randomized study of the Angio-Seal device vs. the Femostop device. Int J Cardiol 2000;76:235-240.
    • (2000) Int J Cardiol , vol.76 , pp. 235-240
    • Amin, F.R.1    Yousufuddin, M.2    Stables, R.3
  • 2
    • 0028022156 scopus 로고
    • Collagen application versus manual compression: A prospective randomized trial for arterial puncture site closure after coronary angioplasty
    • Camenzind E, Grossholz M, Urban P, et al. Collagen application versus manual compression: A prospective randomized trial for arterial puncture site closure after coronary angioplasty. J Am Coll Cardiol 1994;24:655-662.
    • (1994) J Am Coll Cardiol , vol.24 , pp. 655-662
    • Camenzind, E.1    Grossholz, M.2    Urban, P.3
  • 3
    • 0033564591 scopus 로고    scopus 로고
    • Management of arterial puncture site after catheterization procedures: Evaluating a suture-mediated closure device
    • Gerckens U, Cattelaens N, Lampe EG, Grube E. Management of arterial puncture site after catheterization procedures: Evaluating a suture-mediated closure device. Am J Cardiol 1999;83:1658-1663.
    • (1999) Am J Cardiol , vol.83 , pp. 1658-1663
    • Gerckens, U.1    Cattelaens, N.2    Lampe, E.G.3    Grube, E.4
  • 4
    • 0031043073 scopus 로고    scopus 로고
    • Use of a collagen plug versus manual compression for sealing arterial puncture site after cardiac catheterization
    • Gwechenberger M, Katzenschlager R, Heinz G, et al. Use of a collagen plug versus manual compression for sealing arterial puncture site after cardiac catheterization. Angiology 1997;48:121-126.
    • (1997) Angiology , vol.48 , pp. 121-126
    • Gwechenberger, M.1    Katzenschlager, R.2    Heinz, G.3
  • 5
    • 0029034865 scopus 로고
    • Rapid arterial hemostasis and decreased access site complications after cardiac catheterization and angioplasty: Results of a randomized trial of a novel hemostatic device
    • Kussmaul WG, Buchbinder M, Whitlow PW, et al. Rapid arterial hemostasis and decreased access site complications after cardiac catheterization and angioplasty: Results of a randomized trial of a novel hemostatic device. J Am Coll Cardiol 1995;25:1685-1692.
    • (1995) J Am Coll Cardiol , vol.25 , pp. 1685-1692
    • Kussmaul, W.G.1    Buchbinder, M.2    Whitlow, P.W.3
  • 6
    • 0034193750 scopus 로고    scopus 로고
    • A randomized controlled trial of Prostar Plus for haemostasis in patients after coronary angioplasty
    • Noguchi T, Miyazaki S, Yasuda S, et al. A randomized controlled trial of Prostar Plus for haemostasis in patients after coronary angioplasty. Eur J Endovasc Surg 2000;19:451-455.
    • (2000) Eur J Endovasc Surg , vol.19 , pp. 451-455
    • Noguchi, T.1    Miyazaki, S.2    Yasuda, S.3
  • 7
    • 0027361507 scopus 로고
    • A multicenter randomized trial comparing a percutaneous collagen hemostasis device with conventional manual compression after diagnostic angiography and angioplasty
    • Sanborn TA, Gibbs HH, Brinker JA, et al. A multicenter randomized trial comparing a percutaneous collagen hemostasis device with conventional manual compression after diagnostic angiography and angioplasty. J Am Coll Cardiol 1993;22:1273-1279.
    • (1993) J Am Coll Cardiol , vol.22 , pp. 1273-1279
    • Sanborn, T.A.1    Gibbs, H.H.2    Brinker, J.A.3
  • 8
    • 0026475648 scopus 로고
    • Collagen application for sealing of arterial puncture sites in comparison to pressure dressing: A randomized trial
    • Schrader R, Steinbacher S, Burger W, et al. Collagen application for sealing of arterial puncture sites in comparison to pressure dressing: A randomized trial. Cathet Cardiovasc Diagn 1992;27:298-302.
    • (1992) Cathet Cardiovasc Diagn , vol.27 , pp. 298-302
    • Schrader, R.1    Steinbacher, S.2    Burger, W.3
  • 9
    • 0345516041 scopus 로고    scopus 로고
    • Usefulness of collagen plugging with VasoSeal after PTCA as compared to manual compression with identical sheath dwell times
    • Silber S, Bjorvik A, Muhling H, Rosch A. Usefulness of collagen plugging with VasoSeal after PTCA as compared to manual compression with identical sheath dwell times. Cathet Cardiovasc Diagn 1998;43:421-427.
    • (1998) Cathet Cardiovasc Diagn , vol.43 , pp. 421-427
    • Silber, S.1    Bjorvik, A.2    Muhling, H.3    Rosch, A.4
  • 10
    • 0028929625 scopus 로고
    • A single-center randomized trial assessing use of a vascular hemostasis device vs. conventional manual compression following PTCA: What are the potential resource savings?
    • Slaughter PM, Chetty R, Flintoff VF, et al. A single-center randomized trial assessing use of a vascular hemostasis device vs. conventional manual compression following PTCA: What are the potential resource savings? Cathet Cardiovasc Diagn 1995;34:210-214.
    • (1995) Cathet Cardiovasc Diagn , vol.34 , pp. 210-214
    • Slaughter, P.M.1    Chetty, R.2    Flintoff, V.F.3
  • 11
    • 0029028602 scopus 로고
    • Efficacy and safety of collagen implants for haemostasis of the vascular access site after coronary balloon angioplasty and coronary stent implantation
    • von Hoch F, Neumann FJ, Theiss W, et al. Efficacy and safety of collagen implants for haemostasis of the vascular access site after coronary balloon angioplasty and coronary stent implantation. Eur Heart J 1995;16:640-646.
    • (1995) Eur Heart J , vol.16 , pp. 640-646
    • Von Hoch, F.1    Neumann, F.J.2    Theiss, W.3
  • 12
    • 0032031838 scopus 로고    scopus 로고
    • Efficacy and safety of a hemostatic puncture closure device with early ambulation after coronary angiography
    • Ward SR, Casale P, Raymond R, et al. Efficacy and safety of a hemostatic puncture closure device with early ambulation after coronary angiography. Am J Cardiol 1998;81:569-572.
    • (1998) Am J Cardiol , vol.81 , pp. 569-572
    • Ward, S.R.1    Casale, P.2    Raymond, R.3
  • 13
    • 0033795719 scopus 로고    scopus 로고
    • Early sheath removal after coronary artery interventions with use of a suture-mediated closure device: Clinical outcome and results of Doppler US evaluation
    • Wetter DR, Rickli H, won Smekal A, Amann F. Early sheath removal after coronary artery interventions with use of a suture-mediated closure device: Clinical outcome and results of Doppler US evaluation. J Vasc Intervent Radiol 2000;11:1033-1037.
    • (2000) J Vasc Intervent Radiol , vol.11 , pp. 1033-1037
    • Wetter, D.R.1    Rickli, H.2    Won Smekal, A.3    Amann, F.4
  • 14
    • 0034176701 scopus 로고    scopus 로고
    • Suture-mediated closure of the femoral access site after cardiac catheterization: Results of the suture to ambulate and discharge (STAND I and STAND II) trials
    • Baim DS, Knopf WD, Honohara T, et al. Suture-mediated closure of the femoral access site after cardiac catheterization: Results of the suture to ambulate and discharge (STAND I and STAND II) trials. Am J Cardiol 2000;85:864-869.
    • (2000) Am J Cardiol , vol.85 , pp. 864-869
    • Baim, D.S.1    Knopf, W.D.2    Honohara, T.3
  • 15
    • 0036242616 scopus 로고    scopus 로고
    • Assessment of the safety and efficacy of the DUETT vascular hemostasis device: Final results of the safe and effective vascular hemostasis (SEAL) trial
    • The SEAL Trial Study Team. Assessment of the safety and efficacy of the DUETT vascular hemostasis device: Final results of the safe and effective vascular hemostasis (SEAL) trial. Am Heart J 2002;143:612-619.
    • (2002) Am Heart J , vol.143 , pp. 612-619
  • 16
    • 0037372717 scopus 로고    scopus 로고
    • Effect of a closure device on complication rates in high-local-risk patients: Results of a randomized multicenter trial
    • Chevalier B, Lancelin B, Koning R, et al., for the HEMOSTASE Trial Investigators. Effect of a closure device on complication rates in high-local-risk patients: Results of a randomized multicenter trial. Cathet Cardiovasc Interv 2003;58:285-291.
    • (2003) Cathet Cardiovasc Interv , vol.58 , pp. 285-291
    • Chevalier, B.1    Lancelin, B.2    Koning, R.3
  • 17
    • 0032525976 scopus 로고    scopus 로고
    • Improved clinical effectiveness with a collagen vascular hemostasis device for shortened immobilization time following diagnostic angiography and percutaneous transluminal coronary angioplasty
    • Brachmann J, Ansah M, Kosinski EJ, Schuler GC. Improved clinical effectiveness with a collagen vascular hemostasis device for shortened immobilization time following diagnostic angiography and percutaneous transluminal coronary angioplasty. Am J Cardiol 1998;81:1502-1504.
    • (1998) Am J Cardiol , vol.81 , pp. 1502-1504
    • Brachmann, J.1    Ansah, M.2    Kosinski, E.J.3    Schuler, G.C.4
  • 18
    • 0002606538 scopus 로고
    • Hemostatic puncture closure device versus regular compression: A randomized study
    • Chevalier B, Lancelin B, Berthaux X. Hemostatic puncture closure device versus regular compression: A randomized study. J Am Coll Cardiol 1995;25:93A.
    • (1995) J Am Coll Cardiol , vol.25
    • Chevalier, B.1    Lancelin, B.2    Berthaux, X.3
  • 19
    • 24544452024 scopus 로고
    • Comparison of hemostasis time and vascular complications between the Angio-Seal hemostatic puncture closure device and manual pressure
    • Condon JV, Eisner GB, Nootens MT, et al. Comparison of hemostasis time and vascular complications between the Angio-Seal hemostatic puncture closure device and manual pressure. Circulation 1995;92:1-599.
    • (1995) Circulation , vol.92 , pp. 1-599
    • Condon, J.V.1    Eisner, G.B.2    Nootens, M.T.3
  • 20
    • 0035347050 scopus 로고    scopus 로고
    • Femoral arterial puncture management after percutaneous coronary procedures: A comparison of clinical outcomes and patient satisfaction between manual compression and two different vascular closure devices
    • Duffin DC, Muhlestein JB, Allison SB, et al. Femoral arterial puncture management after percutaneous coronary procedures: A comparison of clinical outcomes and patient satisfaction between manual compression and two different vascular closure devices. J Invas Cardiol 2001;13:354-362.
    • (2001) J Invas Cardiol , vol.13 , pp. 354-362
    • Duffin, D.C.1    Muhlestein, J.B.2    Allison, S.B.3
  • 21
    • 0027372249 scopus 로고
    • Improve anticoagulation management after Palmaz-Schatz coronary stent implantation by sealing the arterial puncture site with a vascular hemostasis device
    • Kiemeneij F, Laarman GJ. Improve anticoagulation management after Palmaz-Schatz coronary stent implantation by sealing the arterial puncture site with a vascular hemostasis device. Cathet Cardiovasc Diagn 1993;30:317-322.
    • (1993) Cathet Cardiovasc Diagn , vol.30 , pp. 317-322
    • Kiemeneij, F.1    Laarman, G.J.2
  • 22
    • 0344106616 scopus 로고
    • Comparison of puncture site closure with collagen plug (Vasoseal) or by early manual compression following PTCA
    • Legrand V, Doneux P. Comparison of puncture site closure with collagen plug (Vasoseal) or by early manual compression following PTCA. Circulation 1995;88:1-72.
    • (1995) Circulation , vol.88 , pp. 1-72
    • Legrand, V.1    Doneux, P.2
  • 23
    • 2442621703 scopus 로고    scopus 로고
    • A randomized controlled prospective study of the Angio-Seal device versus manual pressure for rapid arterial puncture closure
    • Murray CR, Mortzavi A, Warth DC, Buchbinder M. A randomized controlled prospective study of the Angio-Seal device versus manual pressure for rapid arterial puncture closure. Circulation 1996;94:1-376.
    • (1996) Circulation , vol.94 , pp. 1-376
    • Murray, C.R.1    Mortzavi, A.2    Warth, D.C.3    Buchbinder, M.4
  • 24
    • 0023036598 scopus 로고
    • A general estimator for the variance of the Mantel-Haenszel odds ratio
    • Robins JM, Greenland S, Breslow NE. A general estimator for the variance of the Mantel-Haenszel odds ratio. Am J Epidemiol 1986;124:719-723.
    • (1986) Am J Epidemiol , vol.124 , pp. 719-723
    • Robins, J.M.1    Greenland, S.2    Breslow, N.E.3
  • 25
    • 0024546358 scopus 로고
    • A comparison of statistical methods for combining event rates from clinical trials
    • Berlin JA, Laird NM, Sacks HS, Chalmers TC. A comparison of statistical methods for combining event rates from clinical trials. Stat Med 1989;8:141-151.
    • (1989) Stat Med , vol.8 , pp. 141-151
    • Berlin, J.A.1    Laird, N.M.2    Sacks, H.S.3    Chalmers, T.C.4
  • 26
    • 0034908828 scopus 로고    scopus 로고
    • It's time to seal every artery, but... Comparing apples and oranges in the vascular sealing literature
    • Turi ZG. It's time to seal every artery, but... Comparing apples and oranges in the vascular sealing literature. Cathet Cardiovasc Intervent 2001;53:443-444.
    • (2001) Cathet Cardiovasc Intervent , vol.53 , pp. 443-444
    • Turi, Z.G.1
  • 27
    • 19044383002 scopus 로고    scopus 로고
    • A prospective randomized trial comparing the safety and efficacy of three commercially available closure devices (Angio-Seal, Vasoseal and Duett)
    • Michalis LK, Rees MR, Patsouras D, et al. A prospective randomized trial comparing the safety and efficacy of three commercially available closure devices (Angio-Seal, Vasoseal and Duett). Cardiovasc Intervent Radiol 2002;25:423-429.
    • (2002) Cardiovasc Intervent Radiol , vol.25 , pp. 423-429
    • Michalis, L.K.1    Rees, M.R.2    Patsouras, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.