메뉴 건너뛰기




Volumn 81, Issue 5, 1998, Pages 569-572

Efficacy and safety of a hemostatic puncture closure device with early ambulation after coronary angiography

Author keywords

[No Author keywords available]

Indexed keywords

COLLAGEN; POLYGLACTIN;

EID: 0032031838     PISSN: 00029149     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0002-9149(97)00970-3     Document Type: Article
Times cited : (126)

References (13)
  • 1
    • 0026527394 scopus 로고
    • Peripheral vascular complications after conventional and complex percutaneous coronary interventional procedures
    • Muller DW, Shamir KJ, Ellis SG, Topol EJ. Peripheral vascular complications after conventional and complex percutaneous coronary interventional procedures. Am J Cardiol 1992;69:63-68.
    • (1992) Am J Cardiol , vol.69 , pp. 63-68
    • Muller, D.W.1    Shamir, K.J.2    Ellis, S.G.3    Topol, E.J.4
  • 2
    • 0027278949 scopus 로고
    • Retroperitoneal hematoma following femoral arterial catheterization: A serious and often fatal complication
    • Sreeram S, Lumsden AB, Miller JS, Salam AA, Dodson TF, Smith RB. Retroperitoneal hematoma following femoral arterial catheterization: a serious and often fatal complication. Am Surg 1993;59:94-98.
    • (1993) Am Surg , vol.59 , pp. 94-98
    • Sreeram, S.1    Lumsden, A.B.2    Miller, J.S.3    Salam, A.A.4    Dodson, T.F.5    Smith, R.B.6
  • 3
    • 0028360526 scopus 로고
    • Vascular complications of cardiac catheterization
    • Ricci MA, Trevisani GT, Pilcher DB. Vascular complications of cardiac catheterization. Am J Surg 1994;167:375-378.
    • (1994) Am J Surg , vol.167 , pp. 375-378
    • Ricci, M.A.1    Trevisani, G.T.2    Pilcher, D.B.3
  • 7
    • 0026741040 scopus 로고
    • Initial experience with a new compression device for hemostasis after femoral arterial puncture
    • Roth R, Modrisic K, Brown M, Kern MS. Initial experience with a new compression device for hemostasis after femoral arterial puncture. Cathet Cardiovasc Diagn 1992;26:241-244.
    • (1992) Cathet Cardiovasc Diagn , vol.26 , pp. 241-244
    • Roth, R.1    Modrisic, K.2    Brown, M.3    Kern, M.S.4
  • 8
    • 0028213486 scopus 로고
    • Immediate arterial hemostasis after cardiac catheterization: Initial experience with a new puncture closure device
    • Aker UT, Kensey KR, Heuser RR, Sandza JG, Kussmaul WG. Immediate arterial hemostasis after cardiac catheterization: initial experience with a new puncture closure device. Cathet Cardiovasc Diagn 1994;31:228-232.
    • (1994) Cathet Cardiovasc Diagn , vol.31 , pp. 228-232
    • Aker, U.T.1    Kensey, K.R.2    Heuser, R.R.3    Sandza, J.G.4    Kussmaul, W.G.5
  • 9
    • 0027175065 scopus 로고
    • Early mobilisation after percutaneous cardiac catheterisation using collagen plug (VasoSeal) haemostasis
    • Foran JP, Patel D, Brookes J, Wainwright RJ. Early mobilisation after percutaneous cardiac catheterisation using collagen plug (VasoSeal) haemostasis. Br Heart J 1993;69:424-429.
    • (1993) Br Heart J , vol.69 , pp. 424-429
    • Foran, J.P.1    Patel, D.2    Brookes, J.3    Wainwright, R.J.4
  • 10
    • 0028522215 scopus 로고
    • Puncture site hemostasis
    • Kensey KR. Puncture site hemostasis. J Invas Cardiol 1994;6:273-276.
    • (1994) J Invas Cardiol , vol.6 , pp. 273-276
    • Kensey, K.R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.