메뉴 건너뛰기




Volumn 13, Issue 5, 2001, Pages 354-362

Femoral arterial puncture management after percutaneous coronary procedures: A comparison of clinical outcomes and patient satisfaction between Manual Compression and two different vascular closure devices

Author keywords

Coronary catheterization; Patient satisfaction; Percutaneous closure device

Indexed keywords

ABCIXIMAB; ANTICOAGULANT AGENT; IMMUNOGLOBULIN F(AB) FRAGMENT; MONOCLONAL ANTIBODY;

EID: 0035347050     PISSN: 10423931     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (137)

References (15)
  • 1
    • 0027361507 scopus 로고    scopus 로고
    • A multicenter randomized trial comparing a percutaneous collagen hemostasis device with conventional manual compression after diagnostic angiography and angioplasty
    • Sanborn TA, Gibbs HH, Brinker JA, et al. A multicenter randomized trial comparing a percutaneous collagen hemostasis device with conventional manual compression after diagnostic angiography and angioplasty. J Am Coll Cardiol 1999;22:1273-1279.
    • (1999) J Am Coll Cardiol , vol.22 , pp. 1273-1279
    • Sanborn, T.A.1    Gibbs, H.H.2    Brinker, J.A.3
  • 2
    • 0029034865 scopus 로고
    • Rapid arterial hemostasis and decreased access site complications after cardiac catheterization and angioplasty. Results of a randomized trial of a novel hemostatic device
    • Kussmaul WG III, Buchbinder M, Whitlow PL, et al. Rapid arterial hemostasis and decreased access site complications after cardiac catheterization and angioplasty. Results of a randomized trial of a novel hemostatic device. J Am Coll Cardiol 1995;25:1685-1692.
    • (1995) J Am Coll Cardiol , vol.25 , pp. 1685-1692
    • Kussmaul III, W.G.1    Buchbinder, M.2    Whitlow, P.L.3
  • 3
    • 0027368682 scopus 로고
    • Vascular complications after balloon and new device angioplasty
    • Popma JJ, Satler LF, Augusto PD, et al. Vascular complications after balloon and new device angioplasty. Circulation 1993;88:1569-1577.
    • (1993) Circulation , vol.88 , pp. 1569-1577
    • Popma, J.J.1    Satler, L.F.2    Augusto, P.D.3
  • 4
    • 0032602917 scopus 로고    scopus 로고
    • Vascular sealing devices: Are the advantages sustainable?
    • Shrake KL. Vascular sealing devices: Are the advantages sustainable? J Am Coll Cardiol 1999;33:16-19.
    • (1999) J Am Coll Cardiol , vol.33 , pp. 16-19
    • Shrake, K.L.1
  • 5
    • 0032522410 scopus 로고    scopus 로고
    • A randomized trial of vascular hemostasis techniques to reduce femoral vascular complications after coronary intervention
    • Pracyk JB, Wall TC, Longabough TC, et al. A randomized trial of vascular hemostasis techniques to reduce femoral vascular complications after coronary intervention. Am J Cardiol 1998;81:970-976.
    • (1998) Am J Cardiol , vol.81 , pp. 970-976
    • Pracyk, J.B.1    Wall, T.C.2    Longabough, T.C.3
  • 6
    • 0029377586 scopus 로고
    • The Femstop compression device, utilization guidelines for the critical care nurse
    • Petula SM, Hudalk S. The Femstop compression device, utilization guidelines for the critical care nurse. Dim Crit Care Nurs 1995;14:259-264.
    • (1995) Dim Crit Care Nurs , vol.14 , pp. 259-264
    • Petula, S.M.1    Hudalk, S.2
  • 7
    • 0029266345 scopus 로고
    • Time to hemostasis: A comparison of manual compression vs. mechanical compression of the femoral artery
    • Bogart MA. Time to hemostasis: A comparison of manual compression vs. mechanical compression of the femoral artery. Am J Clin Cardiol 1995;4:149-156.
    • (1995) Am J Clin Cardiol , vol.4 , pp. 149-156
    • Bogart, M.A.1
  • 8
    • 0032525976 scopus 로고    scopus 로고
    • Improved clinical effectiveness with a collagen vascular device for shortened immobilization time following diagnostic angiography and percutaneous transluminal coronary angioplasty
    • Brachmann J, Ansah M, Kosinski EJ, Schuler GD. Improved clinical effectiveness with a collagen vascular device for shortened immobilization time following diagnostic angiography and percutaneous transluminal coronary angioplasty. Am J Clin Cardiol 1998;81:1502-1505.
    • (1998) Am J Clin Cardiol , vol.81 , pp. 1502-1505
    • Brachmann, J.1    Ansah, M.2    Kosinski, E.J.3    Schuler, G.D.4
  • 9
    • 0032020722 scopus 로고    scopus 로고
    • Developing effective physician partnerships: The Vasoseal experience
    • Schrake KL, Zuck VP. Developing effective physician partnerships: The Vasoseal experience. J Cardiovasc Manage 1998;9:26-30.
    • (1998) J Cardiovasc Manage , vol.9 , pp. 26-30
    • Schrake, K.L.1    Zuck, V.P.2
  • 11
    • 0001621728 scopus 로고    scopus 로고
    • Femoral arterial hemostasis using Angio-Seal™ system after coronary and vascular percutaneous angioplasty and stenting
    • Cremonesi A, Fausto C, Tarentino F, et al. Femoral arterial hemostasis using Angio-Seal™ system after coronary and vascular percutaneous angioplasty and stenting. J Invas Cardiol 1998;10:454-469.
    • (1998) J Invas Cardiol , vol.10 , pp. 454-469
    • Cremonesi, A.1    Fausto, C.2    Tarentino, F.3
  • 12
    • 0033093248 scopus 로고    scopus 로고
    • Significant improvements in patient care and cost savings resulting from percutaneous vascular surgery (PVS)
    • Rogers EW, Doty WD, Stewart J. Significant improvements in patient care and cost savings resulting from percutaneous vascular surgery (PVS). J Cardiovasc Manage 1999;10:13-17.
    • (1999) J Cardiovasc Manage , vol.10 , pp. 13-17
    • Rogers, E.W.1    Doty, W.D.2    Stewart, J.3
  • 13
    • 0033564591 scopus 로고    scopus 로고
    • Management of arterial puncture site after catheterization procedures: Evaluating a suture mediated closure device
    • Gerckens U, Cattelaens N, Lampe E, Grupbe E. Management of arterial puncture site after catheterization procedures: Evaluating a suture mediated closure device. Am J Cardiol 1999;83:1658-1663.
    • (1999) Am J Cardiol , vol.83 , pp. 1658-1663
    • Gerckens, U.1    Cattelaens, N.2    Lampe, E.3    Grupbe, E.4
  • 14
    • 0000650023 scopus 로고    scopus 로고
    • Review of the Angio-Seal hemostatic puncture closure device
    • Fry SM. Review of the Angio-Seal hemostatic puncture closure device. J Invas Cardiol 1998;10:111-120.
    • (1998) J Invas Cardiol , vol.10 , pp. 111-120
    • Fry, S.M.1
  • 15
    • 0032031838 scopus 로고    scopus 로고
    • Efficacy and safety of a hemostatic puncture closure device with early ambulation after coronary angioplasty
    • Ward SR, Casale P, Raymond R, et al. Efficacy and safety of a hemostatic puncture closure device with early ambulation after coronary angioplasty. Am J Cardiol 1998;81:569-572.
    • (1998) Am J Cardiol , vol.81 , pp. 569-572
    • Ward, S.R.1    Casale, P.2    Raymond, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.