메뉴 건너뛰기




Volumn 26, Issue 4, 2005, Pages 620-623

Neural response telemetry results with the nucleus 24 contour in a perimodiolar position

Author keywords

Cochlear implants; Contour electrode; Neural response telemetry; Nucleus 24 contour; Perimodiolar position

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; COCHLEA PROSTHESIS; COCHLEAR NUCLEUS; CONGENITAL DEAFNESS; ELECTRODE; HEARING LOSS; HUMAN; IMPLANTATION; NERVE POTENTIAL; NEURAL RESPONSE TELEMETRY; PRIORITY JOURNAL; TELEMETRY;

EID: 22644439163     PISSN: 15317129     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.mao.0000178122.35988.df     Document Type: Article
Times cited : (22)

References (23)
  • 1
    • 0942265287 scopus 로고    scopus 로고
    • Electrophysiologic effects of placing cochlear implant electrodes in a perimodiolar position in young children
    • Wackym PA, Firszt JB, Gaggl W, et al. Electrophysiologic effects of placing cochlear implant electrodes in a perimodiolar position in young children. Laryngoscope 2004;114:71-6.
    • (2004) Laryngoscope , vol.114 , pp. 71-76
    • Wackym, P.A.1    Firszt, J.B.2    Gaggl, W.3
  • 2
    • 0035025489 scopus 로고    scopus 로고
    • The importance of human cochlear anatomy for the results of modiolus-hugging multi-channel cochlear implants
    • Frijns JH, Briaire JJ, Grote JJ. The importance of human cochlear anatomy for the results of modiolus-hugging multi-channel cochlear implants. Otol Neurotol 2001;22:340-9.
    • (2001) Otol Neurotol , vol.22 , pp. 340-349
    • Frijns, J.H.1    Briaire, J.J.2    Grote, J.J.3
  • 3
    • 0033104647 scopus 로고    scopus 로고
    • Strategies to improve electrode positioning and safety in cochlear implants
    • Rebscher SJ, Heilmann M, Bruszewski W, et al. Strategies to improve electrode positioning and safety in cochlear implants. IEEE Trans Biomed Eng 1999;46:340-52.
    • (1999) IEEE Trans Biomed Eng , vol.46 , pp. 340-352
    • Rebscher, S.J.1    Heilmann, M.2    Bruszewski, W.3
  • 4
    • 0030777468 scopus 로고    scopus 로고
    • Guinea pig auditory nerve response triggered by a high density electrode array
    • Jolly CN, Clopton BM, Spelman FA, et al. Guinea pig auditory nerve response triggered by a high density electrode array. Med Prog Technol 1997;21(Suppl):13-23.
    • (1997) Med Prog Technol , vol.21 , Issue.SUPPL. , pp. 13-23
    • Jolly, C.N.1    Clopton, B.M.2    Spelman, F.A.3
  • 5
    • 0028868915 scopus 로고
    • Potential distributions and neural excitation patterns in a rotationally symmetric model of the electrically stimulated cochlea
    • Frijns JH, de Snoo SL, Schoonhoven R. Potential distributions and neural excitation patterns in a rotationally symmetric model of the electrically stimulated cochlea. Hear Res 1995;87:170-86.
    • (1995) Hear Res , vol.87 , pp. 170-186
    • Frijns, J.H.1    De Snoo, S.L.2    Schoonhoven, R.3
  • 6
    • 0027503532 scopus 로고
    • Electrical stimulation of the auditory nerve: The effect of electrode position on neural excitation
    • Shepherd RK, Hatsushika S, Clark GM. Electrical stimulation of the auditory nerve: the effect of electrode position on neural excitation. Hear Res 1993;66:108-20.
    • (1993) Hear Res , vol.66 , pp. 108-120
    • Shepherd, R.K.1    Hatsushika, S.2    Clark, G.M.3
  • 7
    • 0035990161 scopus 로고    scopus 로고
    • Modiolar proximity of three perimodiolar cochlear implant electrodes
    • Balkany TJ, Eshraghi AA, Yang N. Modiolar proximity of three perimodiolar cochlear implant electrodes. Acta Otolaryngol 2002; 122:363-9.
    • (2002) Acta Otolaryngol , vol.122 , pp. 363-369
    • Balkany, T.J.1    Eshraghi, A.A.2    Yang, N.3
  • 8
    • 0035126110 scopus 로고    scopus 로고
    • The contour electrode array: Safety study and initial patient trials of a new perimodiolar design
    • Tykocinski M, Saunders E, Cohen LT, et al. The contour electrode array: safety study and initial patient trials of a new perimodiolar design. Otol Neurotol 2001;22:33-41.
    • (2001) Otol Neurotol , vol.22 , pp. 33-41
    • Tykocinski, M.1    Saunders, E.2    Cohen, L.T.3
  • 9
    • 0036728565 scopus 로고    scopus 로고
    • The nucleus contour electrode array: An electrophysiological study
    • Pasanisi E, Vincenti V, Bacciu A, et al. The nucleus contour electrode array: an electrophysiological study. Laryngoscope 2002;112: 1653-6.
    • (2002) Laryngoscope , vol.112 , pp. 1653-1656
    • Pasanisi, E.1    Vincenti, V.2    Bacciu, A.3
  • 10
    • 0942273625 scopus 로고    scopus 로고
    • Contour electrodes: Surgical approaches and results
    • Kubo T, Takahashi Y, Iwaki T, eds. The Hague, The Netherlands: Kugler Publications
    • Aschendorff A, Klenzner T, Richter B, Laszig R. Contour electrodes: surgical approaches and results. In Kubo T, Takahashi Y, Iwaki T, eds. Cochlear Implants: An Update. The Hague, The Netherlands: Kugler Publications, 2002:295-9.
    • (2002) Cochlear Implants: An Update , pp. 295-299
    • Aschendorff, A.1    Klenzner, T.2    Richter, B.3    Laszig, R.4
  • 11
    • 0025109523 scopus 로고
    • Electrically evoked whole-nerve action potentials: Data from human cochlear implant users
    • Brown CJ, Abbas PJ, Gantz B. Electrically evoked whole-nerve action potentials: data from human cochlear implant users. J Acoust Soc Am 1990;88:1385-91.
    • (1990) J Acoust Soc Am , vol.88 , pp. 1385-1391
    • Brown, C.J.1    Abbas, P.J.2    Gantz, B.3
  • 12
    • 0025243501 scopus 로고
    • Electrically evoked whole-nerve action potentials: Parametric data from the cat
    • Brown CJ, Abbas PJ. Electrically evoked whole-nerve action potentials: parametric data from the cat. J Acoust Soc Am 1990;88: 2205-10.
    • (1990) J Acoust Soc Am , vol.88 , pp. 2205-2210
    • Brown, C.J.1    Abbas, P.J.2
  • 13
    • 0033042930 scopus 로고    scopus 로고
    • Summary of results using the nucleus CI24M implant
    • Abbas PJ, Brown CJ, Shallop JK, et al. Summary of results using the nucleus CI24M implant. Ear Hear 1999;20:45-59.
    • (1999) Ear Hear , vol.20 , pp. 45-59
    • Abbas, P.J.1    Brown, C.J.2    Shallop, J.K.3
  • 14
    • 0034113705 scopus 로고    scopus 로고
    • The relationship between EAP and EABR thresholds and levels used to program the Nucleus 24 speech processor: Data from adults
    • Brown CJ, Hughes ML, Luk B, et al. The relationship between EAP and EABR thresholds and levels used to program the Nucleus 24 speech processor: data from adults. Ear Hear 2000;21:151-63.
    • (2000) Ear Hear , vol.21 , pp. 151-163
    • Brown, C.J.1    Hughes, M.L.2    Luk, B.3
  • 15
    • 0032693388 scopus 로고    scopus 로고
    • Neural response telemetry with the Nucleus CI24M cochlear implant
    • Shallop JK, Facer GW, Peterson A. Neural response telemetry with the Nucleus CI24M cochlear implant. Laryngoscope 1999;109: 1755-9.
    • (1999) Laryngoscope , vol.109 , pp. 1755-1759
    • Shallop, J.K.1    Facer, G.W.2    Peterson, A.3
  • 16
    • 0842348351 scopus 로고    scopus 로고
    • Further prospective findings with compound action potentials from Nucleus 24 cochlear implants
    • Polak M, Hodges AV, King JE, et al. Further prospective findings with compound action potentials from Nucleus 24 cochlear implants. Hear Res 2004;188:104-16.
    • (2004) Hear Res , vol.188 , pp. 104-116
    • Polak, M.1    Hodges, A.V.2    King, J.E.3
  • 17
    • 0023787809 scopus 로고
    • Quantification of human spiral ganglion cells by serial section reconstruction and segmental density estimates
    • Nadol JB. Quantification of human spiral ganglion cells by serial section reconstruction and segmental density estimates. Am J Otolaryngol 1988;9:47-51.
    • (1988) Am J Otolaryngol , vol.9 , pp. 47-51
    • Nadol, J.B.1
  • 18
    • 0021957980 scopus 로고
    • Ganglion cell counts in the cochlea of patients with normal audiograms
    • Hinojosa R, Seligsohn R, Lerner SA. Ganglion cell counts in the cochlea of patients with normal audiograms. Acta Otolaryngol 1985;99:8-13.
    • (1985) Acta Otolaryngol , vol.99 , pp. 8-13
    • Hinojosa, R.1    Seligsohn, R.2    Lerner, S.A.3
  • 19
    • 0022480066 scopus 로고
    • Correlative studies of cochlear neuronal loss with speech discrimination and pure-tone thresholds
    • Pauler M, Schuknecht HF, Thornton AR. Correlative studies of cochlear neuronal loss with speech discrimination and pure-tone thresholds. Arch Otorhinolaryngol 1986;243:200-6.
    • (1986) Arch Otorhinolaryngol , vol.243 , pp. 200-206
    • Pauler, M.1    Schuknecht, H.F.2    Thornton, A.R.3
  • 20
    • 0017357877 scopus 로고
    • Primary neural disorders in the deaf white cat cochlea
    • Pujol R, Rebillard M, Rebillard G. Primary neural disorders in the deaf white cat cochlea. Acta Otolaryngol 1977;83:59-64.
    • (1977) Acta Otolaryngol , vol.83 , pp. 59-64
    • Pujol, R.1    Rebillard, M.2    Rebillard, G.3
  • 21
    • 0017650373 scopus 로고
    • Sudden deafness ith severe loss of cochlear neurons
    • Ishii T, Toriyama M. Sudden deafness ith severe loss of cochlear neurons. Ann Otol Rhinol Laryngol 1977;86:541-7.
    • (1977) Ann Otol Rhinol Laryngol , vol.86 , pp. 541-547
    • Ishii, T.1    Toriyama, M.2
  • 22
    • 0036009014 scopus 로고    scopus 로고
    • The nucleus 24 contour cochlear implant system: Adult clinical trial results
    • Parkinson AJ, Arcaroli J, Staller SJ, et al. The nucleus 24 contour cochlear implant system: adult clinical trial results. Ear Hear 2002;23(1 Suppl):41-8.
    • (2002) Ear Hear , vol.23 , Issue.1 SUPPL. , pp. 41-48
    • Parkinson, A.J.1    Arcaroli, J.2    Staller, S.J.3
  • 23
    • 0036189781 scopus 로고    scopus 로고
    • Threshold, comfortable level and impedance changes as a function of electrodemodiolar distance
    • Saunders E, Cohen L, Aschendorff A, et al. Threshold, comfortable level and impedance changes as a function of electrodemodiolar distance. Ear Hear 2002;23(1 Suppl):28-40.
    • (2002) Ear Hear , vol.23 , Issue.1 SUPPL. , pp. 28-40
    • Saunders, E.1    Cohen, L.2    Aschendorff, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.