메뉴 건너뛰기




Volumn 16, Issue 7, 2005, Pages 999-1005

Pulmonary embolism: Comprehensive evaluation with MR ventilation and perfusion scanning with hyperpolarized helium-3, arterial spin tagging, and contrast-enhanced MRA

Author keywords

[No Author keywords available]

Indexed keywords

GADODIAMIDE; HELIUM; HELIUM 3; UNCLASSIFIED DRUG;

EID: 22244472036     PISSN: 10510443     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.RVI.0000162416.64412.FC     Document Type: Article
Times cited : (29)

References (31)
  • 1
    • 0032499904 scopus 로고    scopus 로고
    • Pulmonary embolism
    • Goldhaber SZ. Pulmonary embolism. N Engl J Med 1998; 339:93-104.
    • (1998) N Engl J Med , vol.339 , pp. 93-104
    • Goldhaber, S.Z.1
  • 2
    • 0025354523 scopus 로고
    • Value of the ventilation/perfusion scan in acute pulmonary embolism: Result of the Prospective Investigation of Pulmonary Embolism Diagnosis (PIOPED)
    • The PIOPED Investigators. Value of the ventilation/perfusion scan in acute pulmonary embolism: result of the Prospective Investigation of Pulmonary Embolism Diagnosis (PIOPED). JAMA 1990; 263:2753-2759.
    • (1990) JAMA , vol.263 , pp. 2753-2759
  • 3
    • 0028787550 scopus 로고
    • Comprehensive analysis of the results of the PIOPED study
    • Worsley DF, Alavi A. Comprehensive analysis of the results of the PIOPED study. J Nucl Med. 1995; 36:2380-2387.
    • (1995) J Nucl Med , vol.36 , pp. 2380-2387
    • Worsley, D.F.1    Alavi, A.2
  • 4
    • 0026577798 scopus 로고
    • The clinical course of pulmonary embolism
    • Carson JL, Kelly MA, Duff A, et al. The clinical course of pulmonary embolism. N Engl J Med 1992; 326:1240-1245.
    • (1992) N Engl J Med , vol.326 , pp. 1240-1245
    • Carson, J.L.1    Kelly, M.A.2    Duff, A.3
  • 5
    • 0031878546 scopus 로고    scopus 로고
    • Pulmonary embolism: Diagnosis with spiral CT and ventilation perfusion scanning-correlation with pulmonary angiographic results or clinical outcome
    • Garg K, Welsh CH, Feyerabend AJ, et al. Pulmonary embolism: diagnosis with spiral CT and ventilation perfusion scanning-correlation with pulmonary angiographic results or clinical outcome. Radiology 1998; 208:201-208.
    • (1998) Radiology , vol.208 , pp. 201-208
    • Garg, K.1    Welsh, C.H.2    Feyerabend, A.J.3
  • 6
    • 0030711577 scopus 로고    scopus 로고
    • Pulmonary embolism: Prospective comparison of spiral CT with ventilation perfusion scintigraphy
    • Garg K, Mayo JR, Remy-Jardin M, Miller NL, et al. Pulmonary embolism: prospective comparison of spiral CT with ventilation perfusion scintigraphy. Radiology 1997; 205:447-452.
    • (1997) Radiology , vol.205 , pp. 447-452
    • Garg, K.1    Mayo, J.R.2    Remy-Jardin, M.3    Miller, N.L.4
  • 7
    • 0026640165 scopus 로고
    • Central volumetric CT with the single-breath-hold technique comparison with pulmonary angiography
    • Remy-Jardin M, Remy J, Wattinne L, et al. Central volumetric CT with the single-breath-hold technique comparison with pulmonary angiography. Radiology 1992; 185:381-387.
    • (1992) Radiology , vol.185 , pp. 381-387
    • Remy-Jardin, M.1    Remy, J.2    Wattinne, L.3
  • 8
    • 0029959067 scopus 로고    scopus 로고
    • Pulmonary embolism: Validation of spiral CT angiography in 149 patients
    • Van Rossum AB, Pattynama PMT, Tjin A, et al. Pulmonary embolism: validation of spiral CT angiography in 149 patients. Radiology 1996; 201:467-470.
    • (1996) Radiology , vol.201 , pp. 467-470
    • Van Rossum, A.B.1    Pattynama, P.M.T.2    Tjin, A.3
  • 9
    • 0029026454 scopus 로고
    • Detection of pulmonary embolism in patients with unresolved clinical and scintigraphic diagnosis: Helical CT vs. angiography
    • Goodman LR, Curtin JJ, Mewissen MW, et al. Detection of pulmonary embolism in patients with unresolved clinical and scintigraphic diagnosis: helical CT vs. angiography. AJR Am J Roentgenol 1995; 164:1369-1374.
    • (1995) AJR Am J Roentgenol , vol.164 , pp. 1369-1374
    • Goodman, L.R.1    Curtin, J.J.2    Mewissen, M.W.3
  • 10
    • 0030939253 scopus 로고    scopus 로고
    • Diagnosis of pulmonary embolism with magnetic resonance angiography
    • Meaney JFM, Weg JG, Chenevert TL, et al. Diagnosis of pulmonary embolism with magnetic resonance angiography, N Engl J Med 1997; 336:1422-1427.
    • (1997) N Engl J Med , vol.336 , pp. 1422-1427
    • Meaney, J.F.M.1    Weg, J.G.2    Chenevert, T.L.3
  • 11
    • 0037062132 scopus 로고    scopus 로고
    • Comparison of contrast-enhanced magnetic resonance angiography and conventional pulmonary angiography for the diagnosis of pulmonary embolism: A prospective study
    • Oudkerk M, van Beek EJ, Wielopolski P, et al. Comparison of contrast-enhanced magnetic resonance angiography and conventional pulmonary angiography for the diagnosis of pulmonary embolism: a prospective study. Lancet 2002; 359:1643-1647.
    • (2002) Lancet , vol.359 , pp. 1643-1647
    • Oudkerk, M.1    Van Beek, E.J.2    Wielopolski, P.3
  • 12
    • 0015009325 scopus 로고
    • Pulmonary angiography in acute pulmonary embolism: Indications, techniques and results in 367 patients
    • Dalen JE, Brooks HC, Johnson LW, et al. Pulmonary angiography in acute pulmonary embolism: indications, techniques and results in 367 patients. Am Heart J 1971; 81:175-185.
    • (1971) Am Heart J , vol.81 , pp. 175-185
    • Dalen, J.E.1    Brooks, H.C.2    Johnson, L.W.3
  • 13
    • 0031961194 scopus 로고    scopus 로고
    • Pulmonary embolism comparison of cut-film and digital pulmonary angiography
    • Hagspiel KD, Polak JF, Grassi CJ, et al. Pulmonary embolism comparison of cut-film and digital pulmonary angiography. Radiology 1998; 207:139-145.
    • (1998) Radiology , vol.207 , pp. 139-145
    • Hagspiel, K.D.1    Polak, J.F.2    Grassi, C.J.3
  • 14
    • 0032928766 scopus 로고    scopus 로고
    • MR perfusion imaging of pulmonary parenchyma using pulsed arterial spin labeling techniques: FAIRER and FAIR
    • Mai VM, Berr SS. MR perfusion imaging of pulmonary parenchyma using pulsed arterial spin labeling techniques: FAIRER and FAIR. J Magn Reson Imaging 1999; 9:483-487.
    • (1999) J Magn Reson Imaging , vol.9 , pp. 483-487
    • Mai, V.M.1    Berr, S.S.2
  • 15
    • 0033623752 scopus 로고    scopus 로고
    • NMR of hyperpolarized 129Xe in the canine chest: Spectral dynamics during a breath-hold
    • Ruppert K, Brookeman JR, Hagspiel KD, Driehuys B, Mugler JP III. NMR of hyperpolarized 129Xe in the canine chest: spectral dynamics during a breath-hold. NMR Biomed 2000; 13: 220-228.
    • (2000) NMR Biomed , vol.13 , pp. 220-228
    • Ruppert, K.1    Brookeman, J.R.2    Hagspiel, K.D.3    Driehuys, B.4    Mugler III, J.P.5
  • 16
    • 4243281909 scopus 로고    scopus 로고
    • 129Xe-The University of Virginia Experience
    • nd International Meeting: Hyperpolarized Gases in Magnetic Resonance: Biomedical Investigations and Clinical Applications, Les Houches, France, June 1999
    • nd International Meeting: Hyperpolarized Gases in Magnetic Resonance: Biomedical Investigations and Clinical Applications, Les Houches, France, June 1999. Eur Radiol 1999; 9:B20.
    • (1999) Eur Radiol , vol.9
    • Hagspiel, K.D.1    Mugler III, J.P.2    Altes, T.A.3
  • 17
    • 0036260633 scopus 로고    scopus 로고
    • Magnetic resonance imaging of the lungs using hyperpolarized noble gases
    • Möller HE, Chen J, Saam B, et al. Magnetic resonance imaging of the lungs using hyperpolarized noble gases. Magn Reson Med 2002; 47:1029-1051.
    • (2002) Magn Reson Med , vol.47 , pp. 1029-1051
    • Möller, H.E.1    Chen, J.2    Saam, B.3
  • 18
    • 0026689524 scopus 로고
    • Contrast-enhanced MR imaging of the lung: Assessments of ventilation and perfusion
    • Berthezene Y, Vexler V, Clement O, et al. Contrast-enhanced MR imaging of the lung: assessments of ventilation and perfusion. Radiology 1992; 183: 667-672.
    • (1992) Radiology , vol.183 , pp. 667-672
    • Berthezene, Y.1    Vexler, V.2    Clement, O.3
  • 19
    • 0036260586 scopus 로고    scopus 로고
    • Pulmonary ventilation and perfusion scanning using hyperpolarized helium-3 MRI and arterial spin tagging in healthy normal subjects and in pulmonary embolism and orthotopic lung transplant patients
    • Lipson DA, Roberts DA, Hansen-Flaschen J, et al. Pulmonary ventilation and perfusion scanning using hyperpolarized helium-3 MRI and arterial spin tagging in healthy normal subjects and in pulmonary embolism and orthotopic lung transplant patients. Magn Reson Med 2002; 47:1073-1076.
    • (2002) Magn Reson Med , vol.47 , pp. 1073-1076
    • Lipson, D.A.1    Roberts, D.A.2    Hansen-Flaschen, J.3
  • 20
    • 0034040936 scopus 로고    scopus 로고
    • Imaging pulmonary blood flow and perfusion using phase-sensitive selective inversion recovery
    • Mai VM, Chen Q, Bankier AA, et al. Imaging pulmonary blood flow and perfusion using phase-sensitive selective inversion recovery. Magn Reson Med 2000; 43:793-795.
    • (2000) Magn Reson Med , vol.43 , pp. 793-795
    • Mai, V.M.1    Chen, Q.2    Bankier, A.A.3
  • 21
    • 0033964957 scopus 로고    scopus 로고
    • Detection of regional pulmonary perfusion deficit of the occluded lung using arterial spin labeling in magnetic resonance imaging
    • Mai VM, Hagspiel KD, Altes T, Goode AR, Williams MB, Berr SS. Detection of regional pulmonary perfusion deficit of the occluded lung using arterial spin labeling in magnetic resonance imaging. J Magn Reson Imaging 2000; 11:97-102.
    • (2000) J Magn Reson Imaging , vol.11 , pp. 97-102
    • Mai, V.M.1    Hagspiel, K.D.2    Altes, T.3    Goode, A.R.4    Williams, M.B.5    Berr, S.S.6
  • 22
    • 0034768727 scopus 로고    scopus 로고
    • Gravity-dependent perfusion of the lung demonstrated with the FAIRER arterial spin tagging method
    • Keilholz SD, Knight-Scott J, Christopher JM, Mai VM, Berr SS. Gravity-dependent perfusion of the lung demonstrated with the FAIRER arterial spin tagging method. Magn Reson Imaging 2001; 19:929-935.
    • (2001) Magn Reson Imaging , vol.19 , pp. 929-935
    • Keilholz, S.D.1    Knight-Scott, J.2    Christopher, J.M.3    Mai, V.M.4    Berr, S.S.5
  • 24
    • 0036021708 scopus 로고    scopus 로고
    • Comparison of first-pass Gd-DOTA and FAIRER MR Perfusion imaging in a rabbit model of pulmonary embolism
    • Keilholz-George S, Mai V, Berr S, Fujiwara N, Hagspiel KD. Comparison of first-pass Gd-DOTA and FAIRER MR Perfusion imaging in a rabbit model of pulmonary embolism. J Magn Reson Imaging 2002; 16:168-171.
    • (2002) J Magn Reson Imaging , vol.16 , pp. 168-171
    • Keilholz-George, S.1    Mai, V.2    Berr, S.3    Fujiwara, N.4    Hagspiel, K.D.5
  • 25
    • 0033923377 scopus 로고    scopus 로고
    • Laser-polarized 3H3 as a probe for dynamic regional measurements of lung perfusion and ventilation using magnetic resonance imaging
    • Viallon V, Berthezene Y, Decorps M, et al. Laser-polarized 3H3 as a probe for dynamic regional measurements of lung perfusion and ventilation using magnetic resonance imaging. Magn Reson Med 2000; 44:1-4.
    • (2000) Magn Reson Med , vol.44 , pp. 1-4
    • Viallon, V.1    Berthezene, Y.2    Decorps, M.3
  • 27
    • 0034759082 scopus 로고    scopus 로고
    • MR ventilation-perfusion imaging of human lung using oxygen-enhanced and arterial spin labeling techniques
    • Mai VM, Bankier AA, Prasad PV, et al. MR ventilation-perfusion imaging of human lung using oxygen-enhanced and arterial spin labeling techniques. J Magn Reson Imaging 2001; 14:574-579.
    • (2001) J Magn Reson Imaging , vol.14 , pp. 574-579
    • Mai, V.M.1    Bankier, A.A.2    Prasad, P.V.3
  • 28
    • 0029907856 scopus 로고    scopus 로고
    • Noninvasive assessment of regional ventilation in the human lung using oxygen-enhanced magnetic resonance imaging
    • Edelman RR, Hatabu H, Tadamura E, Li W, Prasad PV. Noninvasive assessment of regional ventilation in the human lung using oxygen-enhanced magnetic resonance imaging. Nat Med 1996; 2:1236-1239.
    • (1996) Nat Med , vol.2 , pp. 1236-1239
    • Edelman, R.R.1    Hatabu, H.2    Tadamura, E.3    Li, W.4    Prasad, P.V.5
  • 29
    • 0032720216 scopus 로고    scopus 로고
    • Pulmonary disorders: Ventilation-perfusion MR imaging with animal models
    • Chen Q, Levin DL, Kim D, et al. Pulmonary disorders: ventilation- perfusion MR imaging with animal models. Radiology 1999; 213:871-879.
    • (1999) Radiology , vol.213 , pp. 871-879
    • Chen, Q.1    Levin, D.L.2    Kim, D.3
  • 30
    • 0037225768 scopus 로고    scopus 로고
    • Coregistration of acquired MR ventilation and perfusion images-validation in a porcine model
    • Rizi RR, Saha PK, Wang B, et al. Coregistration of acquired MR ventilation and perfusion images-validation in a porcine model. Magn Reson Med 2003; 49:13-18.
    • (2003) Magn Reson Med , vol.49 , pp. 13-18
    • Rizi, R.R.1    Saha, P.K.2    Wang, B.3
  • 31
    • 0036187987 scopus 로고    scopus 로고
    • Combined MR proton lung perfusion/angiography and helium ventilation: Potential for detecting pulmonary emboli and ventilation defects
    • Zheng J, Leawoods JC, Nolte M, et al. Combined MR proton lung perfusion/angiography and helium ventilation: potential for detecting pulmonary emboli and ventilation defects. Magn Reson Med 2002; 47:433-438.
    • (2002) Magn Reson Med , vol.47 , pp. 433-438
    • Zheng, J.1    Leawoods, J.C.2    Nolte, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.