Volumn 11, Issue 2, 2000, Pages 97-102

Detection of regional pulmonary perfusion deficit of the occluded lung using arterial spin labeling in magnetic resonance imaging

Author keywords

Arterial spin labeling; FAIRER; Lung perfusion; MRI; Pulmonary

Indexed keywords

IODINATED CONTRAST MEDIUM; TECHNETIUM 99M;

EID: 0033964957     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1522-2586(200002)11:2<97::AID-JMRI4>3.0.CO;2-8     Document Type: Article
Times cited : (28)

References (28)
  • 1
    • 0025354523 scopus 로고
    • Value of the ventilation/perfusion scan in acute pulmonary embolism: Results of the Prospective Investigation of Pulmonary Embolism Diagnosis (PIOPED)
    • The PIOPED Investigators. Value of the ventilation/perfusion scan in acute pulmonary embolism: results of the Prospective Investigation of Pulmonary Embolism Diagnosis (PIOPED). JAMA 1990;263: 2753-2759.
    • (1990) JAMA , vol.263 , pp. 2753-2759
  • 2
    • 0028046340 scopus 로고
    • A detailed evaluation of patients with acute pulmonary embolism and low or very low probability scan interpretations
    • Worsley DF, Palevsky HI, Alavi A. A detailed evaluation of patients with acute pulmonary embolism and low or very low probability scan interpretations. Arch Intern Med 1994;154:2737-2741.
    • (1994) Arch Intern Med , vol.154 , pp. 2737-2741
    • Worsley, D.F.1    Palevsky, H.I.2    Alavi, A.3
  • 3
    • 0030090545 scopus 로고    scopus 로고
    • Prospective comparison of helical CT and MR imaging in clinically suspected acute pulmonary embolism
    • Sostman HD, Layish DT, Tapson VF, et al. Prospective comparison of helical CT and MR imaging in clinically suspected acute pulmonary embolism. J Magn Reson Imaging 1996;6:275-281.
    • (1996) J Magn Reson Imaging , vol.6 , pp. 275-281
    • Sostman, H.D.1    Layish, D.T.2    Tapson, V.F.3
  • 4
    • 0027966141 scopus 로고
    • Pulmonary angiography and the diagnosis of pulmonary embolism
    • Greenspan R. Pulmonary angiography and the diagnosis of pulmonary embolism. Prog Cardiovasc Dis 1994;37:93-106.
    • (1994) Prog Cardiovasc Dis , vol.37 , pp. 93-106
    • Greenspan, R.1
  • 5
    • 0030939253 scopus 로고    scopus 로고
    • Diagnosis of pulmonary embolism with magnetic resonance
    • Meaney JF, Weg JG, Chenevert TL, et al. Diagnosis of pulmonary embolism with magnetic resonance. N Engl J Med 1997;336:1422-1427.
    • (1997) N Engl J Med , vol.336 , pp. 1422-1427
    • Meaney, J.F.1    Weg, J.G.2    Chenevert, T.L.3
  • 6
    • 0002926370 scopus 로고
    • A mathematical model of diamagnetic line broadening in lung tissue and similar heterogeneous systems: Calculations and measurements
    • Case TA, Durney CH, Ailion DC, Cutillo AG, Morris AH. A mathematical model of diamagnetic line broadening in lung tissue and similar heterogeneous systems: calculations and measurements. J Magn Reson 1987;73:304-314.
    • (1987) J Magn Reson , vol.73 , pp. 304-314
    • Case, T.A.1    Durney, C.H.2    Ailion, D.C.3    Cutillo, A.G.4    Morris, A.H.5
  • 7
    • 0001404296 scopus 로고
    • Calculation and interpretation of inhomogeneous line broadening in models of lungs and other heterogeneous structures
    • Durney CH, Bertolina J, Ailion DC, et al. Calculation and interpretation of inhomogeneous line broadening in models of lungs and other heterogeneous structures. J Magn Reson 1989;85:554-570.
    • (1989) J Magn Reson , vol.85 , pp. 554-570
    • Durney, C.H.1    Bertolina, J.2    Ailion, D.C.3
  • 8
    • 0029760132 scopus 로고    scopus 로고
    • Pulmonary perfusion: Qualitative assessment with dynamic contrast-enhanced MRI using ultrashort TE and inversion recovery turbo FLASH
    • Hatabu H, Gaa J, Kim D, et al. Pulmonary perfusion: qualitative assessment with dynamic contrast-enhanced MRI using ultrashort TE and inversion recovery turbo FLASH. Magn Reson Med 1996;36:503-508.
    • (1996) Magn Reson Med , vol.36 , pp. 503-508
    • Hatabu, H.1    Gaa, J.2    Kim, D.3
  • 9
    • 0030934861 scopus 로고    scopus 로고
    • Pulmonary embolism: Detection with MR perfusion imaging of lung-a feasibility study
    • Amundsen T, Kvaerness J, Jones RA, et al. Pulmonary embolism: detection with MR perfusion imaging of lung-a feasibility study. Radiology 1997;203:181-185.
    • (1997) Radiology , vol.203 , pp. 181-185
    • Amundsen, T.1    Kvaerness, J.2    Jones, R.A.3
  • 11
    • 0027936294 scopus 로고
    • Quantitative mapping of cerebral blood flow and functional localization with echo-planar MR imaging and signal targeting with alternating radio frequency
    • Edelman RR, Siewert B, Darby DG, et al. Quantitative mapping of cerebral blood flow and functional localization with echo-planar MR imaging and signal targeting with alternating radio frequency. Radiology 1994;192:513-520.
    • (1994) Radiology , vol.192 , pp. 513-520
    • Edelman, R.R.1    Siewert, B.2    Darby, D.G.3
  • 12
    • 0026653875 scopus 로고
    • Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation
    • Kwong KK, Belliveau JW, Chesler DA, et al. Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation. Proc Natl Acad Sci USA 1992;89:5675-5679.
    • (1992) Proc Natl Acad Sci USA , vol.89 , pp. 5675-5679
    • Kwong, K.K.1    Belliveau, J.W.2    Chesler, D.A.3
  • 13
    • 0029151256 scopus 로고
    • Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: Application to functional mapping
    • Kim SG. Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: application to functional mapping. Magn Reson Med 1995;34:293-301.
    • (1995) Magn Reson Med , vol.34 , pp. 293-301
    • Kim, S.G.1
  • 14
    • 0012307156 scopus 로고    scopus 로고
    • Pulmonary perfusion: Noninvasive imaging and quantification by magnetic resonance
    • New York
    • Edelman RR, Hatabu H, Tadamurä E, et al. Pulmonary perfusion: noninvasive imaging and quantification by magnetic resonance (abstr). In: Proceedings of the ISMRM 4th Annual Meeting, New York, 1996. p 1314.
    • (1996) Proceedings of the ISMRM 4th Annual Meeting , pp. 1314
    • Edelman, R.R.1    Hatabu, H.2    Tadamurä, E.3
  • 15
    • 0342390872 scopus 로고    scopus 로고
    • Noninvasive imaging of pulmonary blood flow and volume using steady-state arterial spin tagging: Preliminary results in healthy volunteers
    • Vancouver
    • Roberts DA, Gefter W, Hirsch J, et al. Noninvasive imaging of pulmonary blood flow and volume using steady-state arterial spin tagging: preliminary results in healthy volunteers (abstr). In: Proceedings of the ISMRM 5th Annual Meeting, Vancouver, 1997. p 1764.
    • (1997) Proceedings of the ISMRM 5th Annual Meeting , pp. 1764
    • Roberts, D.A.1    Gefter, W.2    Hirsch, J.3
  • 17
    • 0032945093 scopus 로고    scopus 로고
    • Noninvasive MR perfusion imaging of pulmonary parenchyma using flow-sensitive alternating inversion recovery with an extra radiofrequency pulse (FAIRER)
    • Mai VM, Hagspiel KD, Christopher JM, et al. Noninvasive MR perfusion imaging of pulmonary parenchyma using flow-sensitive alternating inversion recovery with an extra radiofrequency pulse (FAIRER). Magn Reson Imaging 1999;17:355-361.
    • (1999) Magn Reson Imaging , vol.17 , pp. 355-361
    • Mai, V.M.1    Hagspiel, K.D.2    Christopher, J.M.3
  • 18
    • 0032928766 scopus 로고    scopus 로고
    • MR perfusion imaging of pulmonary parenchyma using pulsed arterial spin labeling techniques: FAIRER and FAIR
    • Mai VM, Berr SS. MR perfusion imaging of pulmonary parenchyma using pulsed arterial spin labeling techniques: FAIRER and FAIR. J Magn Reson Imaging 1999;9:483-487.
    • (1999) J Magn Reson Imaging , vol.9 , pp. 483-487
    • Mai, V.M.1    Berr, S.S.2
  • 19
    • 0343260506 scopus 로고    scopus 로고
    • MR perfusion imaging of pulmonary parenchyma using arterial spin labeling techniques: FAIRER, FAIR, EST, hybrid FAIRER
    • Philadelphia
    • Mai VM, Knight-Scott J, Chen Q, et al. MR perfusion imaging of pulmonary parenchyma using arterial spin labeling techniques: FAIRER, FAIR, EST, hybrid FAIRER (abstr.). In: Proceedings of the ISMRM 7th Annual Meeting, Philadelphia, 1999. p 1852.
    • (1999) Proceedings of the ISMRM 7th Annual Meeting , pp. 1852
    • Mai, V.M.1    Knight-Scott, J.2    Chen, Q.3
  • 21
    • 78651150557 scopus 로고
    • Distribution of blood flow in isolated lung: Relation to vascular and alveolar pressures
    • West JB, Dollery CT, Naimark A. Distribution of blood flow in isolated lung: relation to vascular and alveolar pressures. J Appl Physiol 1964;19:713-724.
    • (1964) J Appl Physiol , vol.19 , pp. 713-724
    • West, J.B.1    Dollery, C.T.2    Naimark, A.3
  • 25
    • 0029907856 scopus 로고    scopus 로고
    • Noninvasive assessment of regional ventilation in the human lung using oxygen-enhanced magnetic resonance imaging
    • Edelman RR, Hatabu H, Tadamura E, Li W, Prasad PV. Noninvasive assessment of regional ventilation in the human lung using oxygen-enhanced magnetic resonance imaging. Nature Med 1996;2: 1236-1239.
    • (1996) Nature Med , vol.2 , pp. 1236-1239
    • Edelman, R.R.1    Hatabu, H.2    Tadamura, E.3    Li, W.4    Prasad, P.V.5
  • 28
    • 0001945010 scopus 로고    scopus 로고
    • Noninvasive ventilation-perfusion MR imaging using oxygen and FAIRER in humans and in a porcine model of airway obstruction
    • Philadelphia
    • Mai VM, Chen Q, Gladstone S, et al. Noninvasive ventilation-perfusion MR imaging using oxygen and FAIRER in humans and in a porcine model of airway obstruction (abstr.). In: Proceedings of the ISMRM 7th Annual Meeting, Philadelphia, 1999. p 137.
    • (1999) Proceedings of the ISMRM 7th Annual Meeting , pp. 137
    • Mai, V.M.1    Chen, Q.2    Gladstone, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.