메뉴 건너뛰기




Volumn 34, Issue 3, 2005, Pages 140-144

Effects of the automatic exposure compensation on the proximal caries diagnosis

Author keywords

Caries; Diagnostic accuracy; Digital radiography, dental; Radiography, dental

Indexed keywords

ARTICLE; AUTOMATIC EXPOSURE COMPENSATION; DENTAL CARIES; DIAGNOSTIC ACCURACY; DIGITAL RADIOGRAPHY; FILM; HUMAN; HUMAN TISSUE; PLOTS AND CURVES; RADIOLOGIST; ROC CURVE; TOOTH RADIOGRAPHY;

EID: 22044449950     PISSN: 0250832X     EISSN: None     Source Type: Journal    
DOI: 10.1259/dmfr/88681265     Document Type: Article
Times cited : (18)

References (17)
  • 1
    • 0031610927 scopus 로고    scopus 로고
    • Digital radiography and caries diagnosis
    • Wenzel A. Digital radiography and caries diagnosis. Dentomaxillofac Radiol 1998; 27: 3-11.
    • (1998) Dentomaxillofac Radiol , vol.27 , pp. 3-11
    • Wenzel, A.1
  • 2
    • 0027639992 scopus 로고
    • Perception of image quality in direct digital radiography after application of various image treatment filters for detectability of dental disease
    • Wenzel A, Hintze H. Perception of image quality in direct digital radiography after application of various image treatment filters for detectability of dental disease. Dentomaxillofac Radiol 1993; 22: 131-134.
    • (1993) Dentomaxillofac Radiol , vol.22 , pp. 131-134
    • Wenzel, A.1    Hintze, H.2
  • 3
    • 0031197203 scopus 로고    scopus 로고
    • Direct digital radiography for the detection of periapical bone lesions: A clinical study
    • Kullendorff B, Petersson K, Rohlin M. Direct digital radiography for the detection of periapical bone lesions: a clinical study. Endod Dent Traumatol 1997; 13: 183-189.
    • (1997) Endod Dent Traumatol , vol.13 , pp. 183-189
    • Kullendorff, B.1    Petersson, K.2    Rohlin, M.3
  • 4
    • 0030224978 scopus 로고    scopus 로고
    • Technical report. Processing to achieve high-contrast images with computed dental radiography
    • Hayakawa Y, Farman AG, Scarfe WC, Kuroyanagi K. Technical report. Processing to achieve high-contrast images with computed dental radiography. Dentomaxillofac Radiol 1996; 25: 211-214.
    • (1996) Dentomaxillofac Radiol , vol.25 , pp. 211-214
    • Hayakawa, Y.1    Farman, A.G.2    Scarfe, W.C.3    Kuroyanagi, K.4
  • 5
    • 0029847482 scopus 로고    scopus 로고
    • Pixel value modification using RVG-4 automatic exposure compensation for instant high-contrast images
    • Hayakawa Y, Farman AG, Scarfe WC, Kuroyanagi K. Pixel value modification using RVG-4 automatic exposure compensation for instant high-contrast images. Oral Radiology 1996; 12: 11-17.
    • (1996) Oral Radiology , vol.12 , pp. 11-17
    • Hayakawa, Y.1    Farman, A.G.2    Scarfe, W.C.3    Kuroyanagi, K.4
  • 6
    • 0032610558 scopus 로고    scopus 로고
    • Assessment of image quality in dental radiography, part 2. Optimum exposure conditions for detection of small mass changes in 6 intraoral radiography systems
    • Yoshiura K, Kawazu T, Chikui T, Tatsumi M, Tokumori K, Tanaka T, et al. Assessment of image quality in dental radiography, part 2. Optimum exposure conditions for detection of small mass changes in 6 intraoral radiography systems. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 1999; 87: 123-129.
    • (1999) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.87 , pp. 123-129
    • Yoshiura, K.1    Kawazu, T.2    Chikui, T.3    Tatsumi, M.4    Tokumori, K.5    Tanaka, T.6
  • 7
    • 0029677913 scopus 로고    scopus 로고
    • Observers' use of image enhancement in assessing caries in radiographs taken by four intra-oral digital systems
    • Gotfredsen E, Wenzel A, Gröndahl HG. Observers' use of image enhancement in assessing caries in radiographs taken by four intra-oral digital systems. Dentomaxillofac Radiol 1996; 25: 34-38.
    • (1996) Dentomaxillofac Radiol , vol.25 , pp. 34-38
    • Gotfredsen, E.1    Wenzel, A.2    Gröndahl, H.G.3
  • 8
    • 0026346331 scopus 로고
    • Radiographic detection of occlusal caries in noncavitated teeth. A comparison of conventional film radiographs, digitized film radiographs, and RadioVisioGraphy
    • Wenzel A, Hintze H, Mikkelsen L, Mouyen F. Radiographic detection of occlusal caries in noncavitated teeth. A comparison of conventional film radiographs, digitized film radiographs, and RadioVisioGraphy. Oral Surg Oral Med Oral Pathol 1991; 72: 621-626.
    • (1991) Oral Surg Oral Med Oral Pathol , vol.72 , pp. 621-626
    • Wenzel, A.1    Hintze, H.2    Mikkelsen, L.3    Mouyen, F.4
  • 10
    • 0028440848 scopus 로고
    • Direct digital radiography for the detection of defects in a standard aluminium test object through composite resin restorative materials
    • Golubow NA, Farman AG, von Fraunhofer JA, Kelly MS. Direct digital radiography for the detection of defects in a standard aluminium test object through composite resin restorative materials. Dentomaxillofac Radiol 1994; 23: 91-96.
    • (1994) Dentomaxillofac Radiol , vol.23 , pp. 91-96
    • Golubow, N.A.1    Farman, A.G.2    Von Fraunhofer, J.A.3    Kelly, M.S.4
  • 11
    • 0021336242 scopus 로고
    • Digital image processing: Effect on detectability of simulated low-contrast radiographic patterns
    • Ishida M, Doi K, Loo L-N, Metz CE, Lehr JL. Digital image processing: effect on detectability of simulated low-contrast radiographic patterns. Radiology 1984; 150: 569-575.
    • (1984) Radiology , vol.150 , pp. 569-575
    • Ishida, M.1    Doi, K.2    Loo, L.-N.3    Metz, C.E.4    Lehr, J.L.5
  • 12
    • 1542639421 scopus 로고    scopus 로고
    • Detection of approximal caries with a storage phosphor system. A comparison of enhanced digital images with dental X-ray film
    • Møystad A, Svanaes DB, Risnes S, Larheim TA, Gröndahl HG. Detection of approximal caries with a storage phosphor system. A comparison of enhanced digital images with dental X-ray film. Dentomaxillofac Radiol 1996; 25: 202-206.
    • (1996) Dentomaxillofac Radiol , vol.25 , pp. 202-206
    • Møystad, A.1    Svanaes, D.B.2    Risnes, S.3    Larheim, T.A.4    Gröndahl, H.G.5
  • 13
    • 0034323618 scopus 로고    scopus 로고
    • Approximal caries depth assessment with storage phosphor versus film radiography. Evaluation of the caries-specific Oslo enhancement procedure
    • Svanaes DB, Møystad A, Larheim TA. Approximal caries depth assessment with storage phosphor versus film radiography. Evaluation of the caries-specific Oslo enhancement procedure. Caries Res 2000; 34: 448-453.
    • (2000) Caries Res , vol.34 , pp. 448-453
    • Svanaes, D.B.1    Møystad, A.2    Larheim, T.A.3
  • 14
    • 0036491504 scopus 로고    scopus 로고
    • Detection of approximal caries in digital radiographs before and after correction for attenuation and visual response. An in vitro study
    • Li G, Yoshiura K, Welander U, Shi X-Q, McDavid W. Detection of approximal caries in digital radiographs before and after correction for attenuation and visual response. An in vitro study. Dentomaxillofac Radiol 2002; 31: 113-116.
    • (2002) Dentomaxillofac Radiol , vol.31 , pp. 113-116
    • Li, G.1    Yoshiura, K.2    Welander, U.3    Shi, X.-Q.4    McDavid, W.5
  • 15
    • 0031421510 scopus 로고    scopus 로고
    • Exposure parameters in Sens-A-Ray direct digital radiography and their effects on diagnostic accuracy of carious lesions
    • Svenson B, Shi X-Q, Stamatakis C, Welander U, Söderfeldt B, Tronje G, et al. Exposure parameters in Sens-A-Ray direct digital radiography and their effects on diagnostic accuracy of carious lesions. Oral Radiology 1997; 13: 83-91.
    • (1997) Oral Radiology , vol.13 , pp. 83-91
    • Svenson, B.1    Shi, X.-Q.2    Stamatakis, C.3    Welander, U.4    Söderfeldt, B.5    Tronje, G.6
  • 16
    • 0028708602 scopus 로고
    • In vitro comparison of D- And E-speed film radiography, RVG, and Visualix digital radiography for the detection of enamel approximal and dentinal occlusal caries lesions
    • Hintze H, Wenzel A, Jones C. In vitro comparison of D- and E-speed film radiography, RVG, and Visualix digital radiography for the detection of enamel approximal and dentinal occlusal caries lesions. Caries Res 1994; 28: 363-367.
    • (1994) Caries Res , vol.28 , pp. 363-367
    • Hintze, H.1    Wenzel, A.2    Jones, C.3
  • 17
    • 0031613130 scopus 로고    scopus 로고
    • A comparison of Kodak Ektaspeed Plus film and the Siemens Sidexis digital imaging system for caries detection using receiver operating characteristic analysis
    • Tyndall DA, Ludlow JB, Platin E, Nair M. A comparison of Kodak Ektaspeed Plus film and the Siemens Sidexis digital imaging system for caries detection using receiver operating characteristic analysis. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 1998; 85: 113-118.
    • (1998) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.85 , pp. 113-118
    • Tyndall, D.A.1    Ludlow, J.B.2    Platin, E.3    Nair, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.