메뉴 건너뛰기




Volumn 18, Issue 4, 2005, Pages 235-241

Anatomical and functional brain imaging using high-resolution echo-planar spectroscopic imaging at 1.5 Tesla

Author keywords

Echo planar spectroscopic imaging; fMRI; Magnetic resonance spectroscopic imaging; Water resonance

Indexed keywords

BANDWIDTH; ENERGY ABSORPTION; FUNCTION EVALUATION; IMAGING TECHNIQUES; WATER;

EID: 21644468140     PISSN: 09523480     EISSN: None     Source Type: Journal    
DOI: 10.1002/nbm.952     Document Type: Article
Times cited : (14)

References (34)
  • 2
    • 0036180435 scopus 로고    scopus 로고
    • Spectrally inhomogeneous BOLD contrast changes detected in rodent tumors with high spectral and spatial resolution MRI
    • Al-Hallaq HA, Fan X, Zamora M, River JN, Moulder JE, Karczmar GS. Spectrally inhomogeneous BOLD contrast changes detected in rodent tumors with high spectral and spatial resolution MRI. NMR Biomed. 2002; 15: 28-36.
    • (2002) NMR Biomed. , vol.15 , pp. 28-36
    • Al-Hallaq, H.A.1    Fan, X.2    Zamora, M.3    River, J.N.4    Moulder, J.E.5    Karczmar, G.S.6
  • 3
    • 0036236461 scopus 로고    scopus 로고
    • Functional and anatomic imaging of tumor vasculature: High resolution MR spetroscopic imaging combined with a superparamagnetic contrast agent
    • Karczmar GS, Fan X, Al-Hallaq HA, River JN, Tarlo K, Kellar K, Zamora M, Rinker-Schaeffer C, Lipton MJ. Functional and anatomic imaging of tumor vasculature: high resolution MR spetroscopic imaging combined with a superparamagnetic contrast agent. Acad. Radiol. 2002; 9(Suppl. 1): S115-S118.
    • (2002) Acad. Radiol. , vol.9 , Issue.SUPPL. 1
    • Karczmar, G.S.1    Fan, X.2    Al-Hallaq, H.A.3    River, J.N.4    Tarlo, K.5    Kellar, K.6    Zamora, M.7    Rinker-Schaeffer, C.8    Lipton, M.J.9
  • 4
    • 0036829894 scopus 로고    scopus 로고
    • Structure of the water resonance in small voxels in rat brain detected with high spectral and spatial resolution MRI
    • Fan X, Du W, MacEneaney PM, Zamora M, Karczmar GS. Structure of the water resonance in small voxels in rat brain detected with high spectral and spatial resolution MRI. J. Magn. Reson. Imag. 2002; 16: 547-552.
    • (2002) J. Magn. Reson. Imag. , vol.16 , pp. 547-552
    • Fan, X.1    Du, W.2    MacEneaney, P.M.3    Zamora, M.4    Karczmar, G.S.5
  • 5
    • 0027973923 scopus 로고
    • Theory of NMR signal behavior in magnetically inhomogeneous tissues: The static dephasing regime
    • Yablonskiy DA, Haacke EM. Theory of NMR signal behavior in magnetically inhomogeneous tissues: the static dephasing regime. Magn. Reson. Med. 1994; 32: 749-763.
    • (1994) Magn. Reson. Med. , vol.32 , pp. 749-763
    • Yablonskiy, D.A.1    Haacke, E.M.2
  • 9
    • 0141618489 scopus 로고    scopus 로고
    • The effect of varying spectral resolution on the quality of high spectral and spatial resolution magnetic resonance images of the breast
    • Medved M, Du W, Zamora MA, Fan X, Olopade OI, MacEneaney PM, Newstead G, Karczmar GS. The effect of varying spectral resolution on the quality of high spectral and spatial resolution magnetic resonance images of the breast. J. Magn. Reson. Imag. 2003; 18: 442-448.
    • (2003) J. Magn. Reson. Imag. , vol.18 , pp. 442-448
    • Medved, M.1    Du, W.2    Zamora, M.A.3    Fan, X.4    Olopade, O.I.5    MacEneaney, P.M.6    Newstead, G.7    Karczmar, G.S.8
  • 15
    • 0038778596 scopus 로고    scopus 로고
    • Microvascular BOLD contribution at 4 and 7 T in the human brain: Gradient-echo and spin-echo fMRI with suppression of blood effects
    • Duong TQ, Yacoub E, Adriany G, Hu X, Ugurbil K, Kim SG. Microvascular BOLD contribution at 4 and 7 T in the human brain: gradient-echo and spin-echo fMRI with suppression of blood effects. Magn. Reson. Med. 2003; 49: 1019-1027.
    • (2003) Magn. Reson. Med. , vol.49 , pp. 1019-1027
    • Duong, T.Q.1    Yacoub, E.2    Adriany, G.3    Hu, X.4    Ugurbil, K.5    Kim, S.G.6
  • 16
    • 0037372093 scopus 로고    scopus 로고
    • Functional magnetic resonance imaging of the human brain based on signal enhancement by extravascular protons (SEEP fMRI)
    • Stroman PW, Tomanek B, Krause V, Frankenstein UN, Malisza KL. Functional magnetic resonance imaging of the human brain based on signal enhancement by extravascular protons (SEEP fMRI). Magn. Res. Med. 2003; 49(3): 433-439.
    • (2003) Magn. Res. Med. , vol.49 , Issue.3 , pp. 433-439
    • Stroman, P.W.1    Tomanek, B.2    Krause, V.3    Frankenstein, U.N.4    Malisza, K.L.5
  • 17
    • 12844253960 scopus 로고    scopus 로고
    • Functional magnetic resonance imaging of the human brain and spinal cord by means of signal enhancement by extravascular protons
    • Stroman PW, Tomanek B, Malisza KL. Functional magnetic resonance imaging of the human brain and spinal cord by means of signal enhancement by extravascular protons. Conc. Magn. Reson. A 2003; 16(1): 28-34.
    • (2003) Conc. Magn. Reson. A , vol.16 , Issue.1 , pp. 28-34
    • Stroman, P.W.1    Tomanek, B.2    Malisza, K.L.3
  • 18
    • 0021669012 scopus 로고
    • Spatial mapping of the chemical shift in NMR
    • Mansfield P. Spatial mapping of the chemical shift in NMR. Magn. Reson. Med. 1984; 1: 370-386.
    • (1984) Magn. Reson. Med. , vol.1 , pp. 370-386
    • Mansfield, P.1
  • 19
    • 0028978906 scopus 로고
    • High speed 1H spectroscopic imaging in human brain by echo planar spatial-spectral encoding
    • Posse S, Tedeschi G, Risinger R, Ogg R, Le Bihan D. High speed 1H spectroscopic imaging in human brain by echo planar spatial-spectral encoding. Magn. Reson. Med. 1995; 33: 34-40.
    • (1995) Magn. Reson. Med. , vol.33 , pp. 34-40
    • Posse, S.1    Tedeschi, G.2    Risinger, R.3    Ogg, R.4    Le Bihan, D.5
  • 20
    • 0021948756 scopus 로고
    • Measurement of signal intensities in the presence of noise in MR images
    • Henkelman RM. Measurement of signal intensities in the presence of noise in MR images. Med. Phys. 1985; 12: 232-233.
    • (1985) Med. Phys. , vol.12 , pp. 232-233
    • Henkelman, R.M.1
  • 21
    • 0028387214 scopus 로고
    • Spin-echo and gradient-echo EPI of human brain activation using BOLD contrast: A comparative study at 1.5 T
    • Bandettini PA, Wong EC, Jesmanowicz A, Hinks RS, Hyde JS. Spin-echo and gradient-echo EPI of human brain activation using BOLD contrast: a comparative study at 1.5 T. NMR Biomed. 1994; 7: 12-20.
    • (1994) NMR Biomed. , vol.7 , pp. 12-20
    • Bandettini, P.A.1    Wong, E.C.2    Jesmanowicz, A.3    Hinks, R.S.4    Hyde, J.S.5
  • 22
    • 0030834248 scopus 로고    scopus 로고
    • Spectroscopic imaging of the water resonance with short repetition time to study tumor response to hyperoxia
    • Oikawa H, Al-Hallaq HA, Lewis MZ, River JN, Kovar DA, Karczmar GS. Spectroscopic imaging of the water resonance with short repetition time to study tumor response to hyperoxia. Magn. Reson. Med. 1997; 38: 27-32.
    • (1997) Magn. Reson. Med. , vol.38 , pp. 27-32
    • Oikawa, H.1    Al-Hallaq, H.A.2    Lewis, M.Z.3    River, J.N.4    Kovar, D.A.5    Karczmar, G.S.6
  • 23
    • 0038101604 scopus 로고    scopus 로고
    • Reduction of spectral ghost artifacts in high-resolution echo-planar spectroscopic imaging of water and fat resonances
    • Du W, Du YP, Fan X, Zamora MA, Karczmar GS. Reduction of spectral ghost artifacts in high-resolution echo-planar spectroscopic imaging of water and fat resonances. Magn. Reson. Med. 2003; 49: 1113-1120.
    • (2003) Magn. Reson. Med. , vol.49 , pp. 1113-1120
    • Du, W.1    Du, Y.P.2    Fan, X.3    Zamora, M.A.4    Karczmar, G.S.5
  • 25
    • 0028147317 scopus 로고
    • Detection of brain activation using oxygenation sensitive functional spectroscopy
    • Hennig J, Ernst T, Speck O, Deuschl G, Feifel E. Detection of brain activation using oxygenation sensitive functional spectroscopy. Magn. Reson. Med. 1994; 31: 85-90.
    • (1994) Magn. Reson. Med. , vol.31 , pp. 85-90
    • Hennig, J.1    Ernst, T.2    Speck, O.3    Deuschl, G.4    Feifel, E.5
  • 26
    • 0031596012 scopus 로고    scopus 로고
    • 2*-parameter mapping using multi-image EPI
    • 2*-parameter mapping using multi-image EPI. Magn. Reson. Med. 1998; 40: 243-248.
    • (1998) Magn. Reson. Med. , vol.40 , pp. 243-248
    • Speck, O.1    Hennig, J.2
  • 27
    • 0027265576 scopus 로고
    • Identification of vascular structures as a major source of signal contrast in high resolution 2D and 3D functional activation imaging of the motor cortex at 1.5 T: Preliminary results
    • Lai S, Hopkins AL, Haacke EM, Li D, Wasserman BA, Buckley P, Friedman L, Meltzer H, Hedera P, Friedman R. Identification of vascular structures as a major source of signal contrast in high resolution 2D and 3D functional activation imaging of the motor cortex at 1.5 T: preliminary results. Magn. Reson. Med. 1993; 30: 387-392.
    • (1993) Magn. Reson. Med. , vol.30 , pp. 387-392
    • Lai, S.1    Hopkins, A.L.2    Haacke, E.M.3    Li, D.4    Wasserman, B.A.5    Buckley, P.6    Friedman, L.7    Meltzer, H.8    Hedera, P.9    Friedman, R.10
  • 29
    • 0031907230 scopus 로고    scopus 로고
    • Quantitation of intrinsic magnetic susceptibility-related effects in a tissue matrix. Phantom study
    • Yablonskiy DA. Quantitation of intrinsic magnetic susceptibility-related effects in a tissue matrix. Phantom study. Magn. Reson. Med. 1998; 39: 417-428.
    • (1998) Magn. Reson. Med. , vol.39 , pp. 417-428
    • Yablonskiy, D.A.1
  • 31
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): Ultra-fast imaging with radiofrequency coil arrays
    • Sodickson DK, Manning WJ. Simultaneous acquisition of spatial harmonics (SMASH): ultra-fast imaging with radiofrequency coil arrays. Magn. Reson. Med. 1997; 38: 591-603.
    • (1997) Magn. Reson. Med. , vol.38 , pp. 591-603
    • Sodickson, D.K.1    Manning, W.J.2
  • 32
    • 0027499838 scopus 로고
    • Functional MRI of human brain activation at high spatial resolution
    • Frahm J, Merboldt KD, Hanicke W. Functional MRI of human brain activation at high spatial resolution. Magn. Reson. Med. 1993; 29: 139-144.
    • (1993) Magn. Reson. Med. , vol.29 , pp. 139-144
    • Frahm, J.1    Merboldt, K.D.2    Hanicke, W.3
  • 33
    • 0033005698 scopus 로고    scopus 로고
    • Submillimeter functional localization in human striate cortex using BOLD contrast at 4 Tesla: Implications for the vascular point-spread function
    • Menon RS, Goodyear BG. Submillimeter functional localization in human striate cortex using BOLD contrast at 4 Tesla: implications for the vascular point-spread function. Magn. Reson. Med. 1999; 41: 230-235.
    • (1999) Magn. Reson. Med. , vol.41 , pp. 230-235
    • Menon, R.S.1    Goodyear, B.G.2
  • 34
    • 0034952064 scopus 로고    scopus 로고
    • High-resolution fMRI using multislice partial k-space GR-EPI with cubic voxels
    • Hyde JS, Biswal BB, Jesmanowicz A. High-resolution fMRI using multislice partial k-space GR-EPI with cubic voxels. Magn. Reson. Med. 2001; 46: 114-125.
    • (2001) Magn. Reson. Med. , vol.46 , pp. 114-125
    • Hyde, J.S.1    Biswal, B.B.2    Jesmanowicz, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.