메뉴 건너뛰기




Volumn 74, Issue 1, 2005, Pages 570-581

Current status of prosthetic bypass grafts: A review

Author keywords

Dacron ; EPTFE; Microvessel; Polymer; Polypropylene; Polyurethane; Prosthesis; Vascular graft

Indexed keywords

BIOMATERIALS; POLYTETRAFLUOROETHYLENES; PROSTHETICS; TISSUE;

EID: 21444443183     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/jbm.b.30247     Document Type: Review
Times cited : (472)

References (131)
  • 1
    • 0142043905 scopus 로고    scopus 로고
    • Percutaneous treatment of saphenous vein graft disease: The ongoing challenge
    • Baim DS. Percutaneous treatment of saphenous vein graft disease: the ongoing challenge. J Am Coll Cardiol 2003;42: 1370-1372.
    • (2003) J Am Coll Cardiol , vol.42 , pp. 1370-1372
    • Baim, D.S.1
  • 2
    • 0033146023 scopus 로고    scopus 로고
    • Arterial grafts in coronary bypass surgery
    • Suma H. Arterial grafts in coronary bypass surgery. Ann Thorac Cardiovasc Surg 1999;5:141-145.
    • (1999) Ann Thorac Cardiovasc Surg , vol.5 , pp. 141-145
    • Suma, H.1
  • 3
    • 0034991257 scopus 로고    scopus 로고
    • Is the preferential use of ePTFE grafts in femorofemoral bypass justified?
    • Lau H, Cheng SW. Is the preferential use of ePTFE grafts in femorofemoral bypass justified? Ann Vasc Surg 2001;15:383-387.
    • (2001) Ann Vasc Surg , vol.15 , pp. 383-387
    • Lau, H.1    Cheng, S.W.2
  • 4
    • 0026443830 scopus 로고
    • Mechanical issues in vascular grafting: A review
    • Brossollet LJ. Mechanical issues in vascular grafting: a review. Int J Artif Organs 1992;15:579-584.
    • (1992) Int J Artif Organs , vol.15 , pp. 579-584
    • Brossollet, L.J.1
  • 5
    • 0031238929 scopus 로고    scopus 로고
    • Eight years of clinical endothelial cell transplantation. Closing the gap between prosthetic grafts and vein grafts
    • Meinhart J, Deutsch M, Zilla P. Eight years of clinical endothelial cell transplantation. Closing the gap between prosthetic grafts and vein grafts. ASAIO J 1997;43:M515-M521.
    • (1997) ASAIO J , vol.43
    • Meinhart, J.1    Deutsch, M.2    Zilla, P.3
  • 7
    • 0025812456 scopus 로고
    • The effect of preformed confluent endothelial cell monolayers on the patency and thrombogenicity of small calibre vascular grafts
    • Budd JS, Allen KE, Hartley G, Bell PR. The effect of preformed confluent endothelial cell monolayers on the patency and thrombogenicity of small calibre vascular grafts. Eur J Vasc Surg 1991;5:397-405.
    • (1991) Eur J Vasc Surg , vol.5 , pp. 397-405
    • Budd, J.S.1    Allen, K.E.2    Hartley, G.3    Bell, P.R.4
  • 9
    • 0036019428 scopus 로고    scopus 로고
    • Evaluation of polytetrafluoroethylene micrografts in microvascular surgery
    • Harris JR, Seikaly H. Evaluation of polytetrafluoroethylene micrografts in microvascular surgery. J Otolaryngol 2002;31: 89-92.
    • (2002) J Otolaryngol , vol.31 , pp. 89-92
    • Harris, J.R.1    Seikaly, H.2
  • 11
    • 0034898239 scopus 로고    scopus 로고
    • Cell seeded decellularised allogeneic matrix grafts and biodegradable polydioxanone-prostheses compared with arterial autografts in a porcine model
    • Teebken OE, Pichlmaier AM, Haverich A. Cell seeded decellularised allogeneic matrix grafts and biodegradable polydioxanone-prostheses compared with arterial autografts in a porcine model. Eur J Vasc Endovasc Surg 2001;22:139-145.
    • (2001) Eur J Vasc Endovasc Surg , vol.22 , pp. 139-145
    • Teebken, O.E.1    Pichlmaier, A.M.2    Haverich, A.3
  • 12
    • 0027995533 scopus 로고
    • Long-term vein graft patency
    • Bourassa MG. Long-term vein graft patency. Curr Opin Cardiol 1994;9:685-691.
    • (1994) Curr Opin Cardiol , vol.9 , pp. 685-691
    • Bourassa, M.G.1
  • 13
    • 0030860096 scopus 로고    scopus 로고
    • Vessel wall and flow characteristics after carotid endarterectomy: Eversion endarterectomy compared with Dacron patch plasty
    • Baan J Jr, Thompson JM, Reul GJ, Cooley DA, Brand R, Henderson MC, et al. Vessel wall and flow characteristics after carotid endarterectomy: eversion endarterectomy compared with Dacron patch plasty. Eur J Vasc Endovasc Surg 1997;13: 583-591.
    • (1997) Eur J Vasc Endovasc Surg , vol.13 , pp. 583-591
    • Baan Jr., J.1    Thompson, J.M.2    Reul, G.J.3    Cooley, D.A.4    Brand, R.5    Henderson, M.C.6
  • 15
    • 0036124481 scopus 로고    scopus 로고
    • Thermomechanical analysis of a compliant poly(carbonate-urea)urethane after exposure to hydrolytic, oxidative, peroxidative and biological solutions
    • Salacinski HJ, Odlyha M, Hamilton G, Seifalian AM. Thermomechanical analysis of a compliant poly(carbonate-urea)urethane after exposure to hydrolytic, oxidative, peroxidative and biological solutions. Biomaterials 2002;23:2231-2240.
    • (2002) Biomaterials , vol.23 , pp. 2231-2240
    • Salacinski, H.J.1    Odlyha, M.2    Hamilton, G.3    Seifalian, A.M.4
  • 16
    • 0030131075 scopus 로고    scopus 로고
    • Role of polymers in improving the results of stenting in coronary arteries
    • Peng T, Gibula P, Yao KD, Goosen MF. Role of polymers in improving the results of stenting in coronary arteries. Biomaterials 1996;17:685-694.
    • (1996) Biomaterials , vol.17 , pp. 685-694
    • Peng, T.1    Gibula, P.2    Yao, K.D.3    Goosen, M.F.4
  • 17
    • 0003091108 scopus 로고
    • Vascular grafts
    • Bronzino J, editor. Boca Raton, FL: CRC Press
    • Ku DN, Allen RC. Vascular grafts. In: Bronzino J, editor. The biomedical engineering handbook. Boca Raton, FL: CRC Press; 1995. p 1871-1878.
    • (1995) The Biomedical Engineering Handbook , pp. 1871-1878
    • Ku, D.N.1    Allen, R.C.2
  • 19
    • 0027363489 scopus 로고
    • Dacron prosthesis dilatation. Case report and review of the literature
    • Boss A, Stierli P. Dacron prosthesis dilatation. Case report and review of the literature. Helv Chir Acta 1993;60:153-156.
    • (1993) Helv Chir Acta , vol.60 , pp. 153-156
    • Boss, A.1    Stierli, P.2
  • 20
    • 0037643305 scopus 로고    scopus 로고
    • A long term comparison between Denacol EX-313-treated bovine jugular vein graft and ultrafine polyester fiber graft for reconstruction of tight ventricular outflow tract in dogs
    • Matsumoto H, Sugiyama S, Shibazaki A, Tanaka R, Takashima K, Noishiki Y, et al. A long term comparison between Denacol EX-313-treated bovine jugular vein graft and ultrafine polyester fiber graft for reconstruction of tight ventricular outflow tract in dogs. J Vet Med Sci 2003;65:363-368.
    • (2003) J Vet Med Sci , vol.65 , pp. 363-368
    • Matsumoto, H.1    Sugiyama, S.2    Shibazaki, A.3    Tanaka, R.4    Takashima, K.5    Noishiki, Y.6
  • 23
    • 0030245623 scopus 로고    scopus 로고
    • Biological molecule-impregnated polyester: An in vivo angiogenesis study
    • Fournier N, Doillon CJ. Biological molecule-impregnated polyester: an in vivo angiogenesis study. Biomaterials 1996; 17:1659-1665.
    • (1996) Biomaterials , vol.17 , pp. 1659-1665
    • Fournier, N.1    Doillon, C.J.2
  • 24
    • 0034837690 scopus 로고    scopus 로고
    • Collagen versus gelatin-coated Dacron versus stretch polytetrafluoroethylene in abdominal aortic bifurcation graft surgery: Results of a seven-year prospective, randomized multicenter trial
    • Prager M, Polterauer P, Bohmig HJ, Wagner O, Fugl A, Kretschmer G, et al. Collagen versus gelatin-coated Dacron versus stretch polytetrafluoroethylene in abdominal aortic bifurcation graft surgery: results of a seven-year prospective, randomized multicenter trial. Surgery 2001;130:408-414.
    • (2001) Surgery , vol.130 , pp. 408-414
    • Prager, M.1    Polterauer, P.2    Bohmig, H.J.3    Wagner, O.4    Fugl, A.5    Kretschmer, G.6
  • 25
    • 0025105260 scopus 로고
    • Present status of reversed vein bypass grafting: Five-year results of a modern series
    • Taylor LM Jr, Edwards JM, Porter JM. Present status of reversed vein bypass grafting: five-year results of a modern series. J Vasc Surg 1990;11:193-205.
    • (1990) J Vasc Surg , vol.11 , pp. 193-205
    • Taylor Jr., L.M.1    Edwards, J.M.2    Porter, J.M.3
  • 26
    • 0027220334 scopus 로고
    • The effect of carbon coating and porosity on early patency of expanded polytetrafluoroethylene grafts: An experimental study
    • Akers DL, Du YH, Kempczinski RF. The effect of carbon coating and porosity on early patency of expanded polytetrafluoroethylene grafts: an experimental study. J Vasc Surg 1993;18:10-15.
    • (1993) J Vasc Surg , vol.18 , pp. 10-15
    • Akers, D.L.1    Du, Y.H.2    Kempczinski, R.F.3
  • 28
    • 0027641736 scopus 로고
    • Quantification of in vitro endothelial cell adhesion to vascular graft material
    • Wigod MD, Klitzman B. Quantification of in vitro endothelial cell adhesion to vascular graft material. J Biomed Mater Res 1993;27:1057-1062.
    • (1993) J Biomed Mater Res , vol.27 , pp. 1057-1062
    • Wigod, M.D.1    Klitzman, B.2
  • 32
    • 0038405176 scopus 로고    scopus 로고
    • Improving compliance at peripheral arterial and cardiovascular anastomosis: The effect of suture materials and techniques
    • Tiwari A, Cheng K, Salacinski HJ, Hamilton G, Seifalian AM. Improving compliance at peripheral arterial and cardiovascular anastomosis: the effect of suture materials and techniques. Eur J Vasc Endovasc Surg 2003;25:325-329.
    • (2003) Eur J Vasc Endovasc Surg , vol.25 , pp. 325-329
    • Tiwari, A.1    Cheng, K.2    Salacinski, H.J.3    Hamilton, G.4    Seifalian, A.M.5
  • 33
    • 0030614329 scopus 로고    scopus 로고
    • Vascugraft polyurethane arterial prosthesis as femoropopliteal and femoro-peroneal bypasses in humans: Pathological, structural and chemical analyses of four excised grafts
    • Zhang Z, Marois Y, Guidoin RG, Bull P, Marois M, How T, et al. Vascugraft polyurethane arterial prosthesis as femoropopliteal and femoro-peroneal bypasses in humans: pathological, structural and chemical analyses of four excised grafts. Biomaterials 1997;18:113-124.
    • (1997) Biomaterials , vol.18 , pp. 113-124
    • Zhang, Z.1    Marois, Y.2    Guidoin, R.G.3    Bull, P.4    Marois, M.5    How, T.6
  • 34
    • 0032898813 scopus 로고    scopus 로고
    • Polyurethane vascular prostheses decreases neointimal formation compared with expanded polytetrafluoroethylene
    • Jeschke MG, Hermanutz V, Wolf SE, Koveker GB. Polyurethane vascular prostheses decreases neointimal formation compared with expanded polytetrafluoroethylene. J Vasc Surg 1999;29:168-176.
    • (1999) J Vasc Surg , vol.29 , pp. 168-176
    • Jeschke, M.G.1    Hermanutz, V.2    Wolf, S.E.3    Koveker, G.B.4
  • 35
    • 0026183543 scopus 로고
    • The composite Corethane/Dacron vascular prosthesis. Canine in vivo evaluation of 4 mm diameter grafts with 1 year follow-up
    • Wilson GJ, MacGregor DC, Klement P, Dereume JP, Weber BA, Binnington AG, et al. The composite Corethane/Dacron vascular prosthesis. Canine in vivo evaluation of 4 mm diameter grafts with 1 year follow-up. ASAIO Trans 1991;37: M475-M476.
    • (1991) ASAIO Trans , vol.37
    • Wilson, G.J.1    MacGregor, D.C.2    Klement, P.3    Dereume, J.P.4    Weber, B.A.5    Binnington, A.G.6
  • 38
    • 35948986208 scopus 로고    scopus 로고
    • Biodegradable synthetic polymers for tissue engineering
    • Gunatillake PA, Adhikari R. Biodegradable synthetic polymers for tissue engineering. Eur Cell Mater 2003;5:1-16.
    • (2003) Eur Cell Mater , vol.5 , pp. 1-16
    • Gunatillake, P.A.1    Adhikari, R.2
  • 39
    • 0037026406 scopus 로고    scopus 로고
    • Synthesis, characterization, and cytocompatibility of elastomeric, biodegradable poly(ester-urethane)ureas based on poly(caprolactone) and putrescine
    • Guan J, Sacks MS, Beckman EJ, Wagner WR. Synthesis, characterization, and cytocompatibility of elastomeric, biodegradable poly(ester-urethane)ureas based on poly(caprolactone) and putrescine. J Biomed Mater Res 2002;61:493-503.
    • (2002) J Biomed Mater Res , vol.61 , pp. 493-503
    • Guan, J.1    Sacks, M.S.2    Beckman, E.J.3    Wagner, W.R.4
  • 41
    • 0030176014 scopus 로고    scopus 로고
    • Surface microarchitectural design in biomedical applications: In vitro transmural endothelialization on microporous segmented polyurethane films fabricated using an excimer laser
    • Matsuda T, Nakayama Y. Surface microarchitectural design in biomedical applications: in vitro transmural endothelialization on microporous segmented polyurethane films fabricated using an excimer laser. J Biomed Mater Res 1996;31:235-242.
    • (1996) J Biomed Mater Res , vol.31 , pp. 235-242
    • Matsuda, T.1    Nakayama, Y.2
  • 42
    • 0035687499 scopus 로고    scopus 로고
    • An approach to constructing three-dimensional tissue
    • Ko IK, Iwata H. An approach to constructing three-dimensional tissue. Ann N Y Acad Sci 2001;944:443-455.
    • (2001) Ann N Y Acad Sci , vol.944 , pp. 443-455
    • Ko, I.K.1    Iwata, H.2
  • 43
    • 0024235855 scopus 로고
    • Fabrication and characterization of small-diameter vascular prostheses
    • Kowligi RR, von Maltzahn WW, Eberhart RC. Fabrication and characterization of small-diameter vascular prostheses. J Biomed Mater Res 1988;22:245-256.
    • (1988) J Biomed Mater Res , vol.22 , pp. 245-256
    • Kowligi, R.R.1    Von Maltzahn, W.W.2    Eberhart, R.C.3
  • 44
    • 0023112495 scopus 로고
    • Long-term biologic fate of neoarteries regenerated in microporous, compliant, biodegradable, small-caliber vascular grafts in rats
    • van der LB, Nieuwenhuis P, Molenaar I, Wildevuur CR. Long-term biologic fate of neoarteries regenerated in microporous, compliant, biodegradable, small-caliber vascular grafts in rats. Surgery 1987;101:459-467.
    • (1987) Surgery , vol.101 , pp. 459-467
    • Van Der, L.B.1    Nieuwenhuis, P.2    Molenaar, I.3    Wildevuur, C.R.4
  • 46
    • 0035747128 scopus 로고    scopus 로고
    • Novel synthetic selectively degradable vascular prostheses: A preliminary implantation study
    • Izhar U, Schwalb H, Borman JB, Hellener GR, Hotoveli-Salomon A, Marom G, et al. Novel synthetic selectively degradable vascular prostheses: a preliminary implantation study. J Surg Res 2001;95:152-160.
    • (2001) J Surg Res , vol.95 , pp. 152-160
    • Izhar, U.1    Schwalb, H.2    Borman, J.B.3    Hellener, G.R.4    Hotoveli-Salomon, A.5    Marom, G.6
  • 48
    • 17144438621 scopus 로고    scopus 로고
    • Tissue engineering of autologous aorta using a new biodegradable polymer
    • Shum-Tim D, Stock U, Hrkach J, Shinoka T, Lien J, Moses MA, et al. Tissue engineering of autologous aorta using a new biodegradable polymer. Ann Thorac Surg 1999;68: 2298-2304.
    • (1999) Ann Thorac Surg , vol.68 , pp. 2298-2304
    • Shum-Tim, D.1    Stock, U.2    Hrkach, J.3    Shinoka, T.4    Lien, J.5    Ma, M.6
  • 49
    • 0024806662 scopus 로고
    • From a synthetic, microporous, compliant, biodegradable small-caliber vascular graft to a new artery
    • van der LB, Wildevuur CR. From a synthetic, microporous, compliant, biodegradable small-caliber vascular graft to a new artery. Thorac Cardiovasc Surg 1989;37:337-347.
    • (1989) Thorac Cardiovasc Surg , vol.37 , pp. 337-347
    • Van Der, L.B.1    Wildevuur, C.R.2
  • 50
    • 0347385151 scopus 로고    scopus 로고
    • Novel method of preparing acellular cardiovascular grafts by decellularization with poly(ethylene glycol)
    • Uchimura E, Sawa Y, Taketani S, Yamanaka Y, Hara M, Matsuda H, et al. Novel method of preparing acellular cardiovascular grafts by decellularization with poly(ethylene glycol). J Biomed Mater Res 2003;67A:834-837.
    • (2003) J Biomed Mater Res , vol.67 A , pp. 834-837
    • Uchimura, E.1    Sawa, Y.2    Taketani, S.3    Yamanaka, Y.4    Hara, M.5    Matsuda, H.6
  • 52
    • 0035569011 scopus 로고    scopus 로고
    • Evaluation of a xenogeneic acellular collagen matrix as a small-diameter vascular graft in dogs-preliminary observations
    • Nemcova S, Noel AA, Jost CJ, Gloviczki P, Miller VM, Brockbank KG. Evaluation of a xenogeneic acellular collagen matrix as a small-diameter vascular graft in dogs-preliminary observations. J Invest Surg 2001;14:321-330.
    • (2001) J Invest Surg , vol.14 , pp. 321-330
    • Nemcova, S.1    Noel, A.A.2    Jost, C.J.3    Gloviczki, P.4    Miller, V.M.5    Brockbank, K.G.6
  • 53
    • 0036773529 scopus 로고    scopus 로고
    • A stable matrix for generation of tissue-engineered nonthrombogenic vascular grafts
    • Kumar TR, Krishnan LK. A stable matrix for generation of tissue-engineered nonthrombogenic vascular grafts. Tissue Eng 2002;8:763-770.
    • (2002) Tissue Eng , vol.8 , pp. 763-770
    • Kumar, T.R.1    Krishnan, L.K.2
  • 54
    • 0036314103 scopus 로고    scopus 로고
    • Utilizing granulocyte colony-stimulating factor to enhance vascular graft endothelialization from circulating blood cells
    • Shi Q, Bhattacharya V, Hong-De Wu M, Sauvage LR. Utilizing granulocyte colony-stimulating factor to enhance vascular graft endothelialization from circulating blood cells. Ann Vasc Surg 2002;16:314-320.
    • (2002) Ann Vasc Surg , vol.16 , pp. 314-320
    • Shi, Q.1    Bhattacharya, V.2    Hong-De Wu, M.3    Sauvage, L.R.4
  • 55
    • 0035425284 scopus 로고    scopus 로고
    • Engineering of vascular ingrowth matrices: Are protein domains an alternative to peptides?
    • Merzkirch C, Davies N, Zilla P. Engineering of vascular ingrowth matrices: are protein domains an alternative to peptides? Anat Rec 2001;263:379-387.
    • (2001) Anat Rec , vol.263 , pp. 379-387
    • Merzkirch, C.1    Davies, N.2    Zilla, P.3
  • 56
    • 0038405176 scopus 로고    scopus 로고
    • Improving endothelial cell retention for single stage seeding of prosthetic grafts: Use of polymer sequences of arginine-glycine-aspartate
    • Tiwari A, Kidane A, Salacinski H, Punshon G, Hamilton G, Seifalian AM. Improving endothelial cell retention for single stage seeding of prosthetic grafts: use of polymer sequences of arginine-glycine-aspartate. Eur J Vasc Endovasc Surg 2003; 25:325-329.
    • (2003) Eur J Vasc Endovasc Surg , vol.25 , pp. 325-329
    • Tiwari, A.1    Kidane, A.2    Salacinski, H.3    Punshon, G.4    Hamilton, G.5    Seifalian, A.M.6
  • 57
    • 0038015691 scopus 로고    scopus 로고
    • Endothelial cell adhesion to the fibronectin CS5 domain in artificial extracellular matrix proteins
    • Heilshorn SC, DiZio KA, Welsh ER, Tirrell DA. Endothelial cell adhesion to the fibronectin CS5 domain in artificial extracellular matrix proteins. Biomaterials 2003;24:4245-4252.
    • (2003) Biomaterials , vol.24 , pp. 4245-4252
    • Heilshorn, S.C.1    Dizio, K.A.2    Welsh, E.R.3    Tirrell, D.A.4
  • 58
    • 0141799707 scopus 로고    scopus 로고
    • Expression of adhesion molecules and cytokines in vitro by endothelial cells seeded on various polymer surfaces coated with titaniumcarboxonitride
    • Lehle K, Buttstaedt J, Birnbaum DE. Expression of adhesion molecules and cytokines in vitro by endothelial cells seeded on various polymer surfaces coated with titaniumcarboxonitride. J Biomed Mater Res 2003;65A:393-401.
    • (2003) J Biomed Mater Res , vol.65 A , pp. 393-401
    • Lehle, K.1    Buttstaedt, J.2    Birnbaum, D.E.3
  • 59
    • 0038046174 scopus 로고    scopus 로고
    • Endothelial cells grown on thin polyelectrolyte mutlilayered films: An evaluation of a new versatile surface modification
    • Boura C, Menu P, Payan E, Picart C, Voegel JC, Muller S, et al. Endothelial cells grown on thin polyelectrolyte mutlilayered films: an evaluation of a new versatile surface modification. Biomaterials 2003;24:3521-3530.
    • (2003) Biomaterials , vol.24 , pp. 3521-3530
    • Boura, C.1    Menu, P.2    Payan, E.3    Picart, C.4    Voegel, J.C.5    Muller, S.6
  • 60
    • 0142248333 scopus 로고    scopus 로고
    • Endothelial and vascular smooth muscle cell function on poly(lactic-co-glycolic acid) with nano-structured surface features
    • Miller DC, Thapa A, Haberstroh KM, Webster TJ. Endothelial and vascular smooth muscle cell function on poly(lactic-co-glycolic acid) with nano-structured surface features. Biomaterials 2004;25:53-61.
    • (2004) Biomaterials , vol.25 , pp. 53-61
    • Miller, D.C.1    Thapa, A.2    Haberstroh, K.M.3    Webster, T.J.4
  • 61
    • 0037323469 scopus 로고    scopus 로고
    • Biomaterials in the development and future of vascular grafts
    • Xue L, Greisler HP. Biomaterials in the development and future of vascular grafts. J Vasc Surg 2003;37:472-480.
    • (2003) J Vasc Surg , vol.37 , pp. 472-480
    • Xue, L.1    Greisler, H.P.2
  • 62
    • 0141446082 scopus 로고    scopus 로고
    • Long-term outcome of femoral above-knee popliteal artery bypass using autologous saphenous vein versus expanded polytetrafluoroethylene grafts
    • Sala F, Hassen-Khodja R, Lecis A, Bouillanne PJ, Declemy S, Batt M. Long-term outcome of femoral above-knee popliteal artery bypass using autologous saphenous vein versus expanded polytetrafluoroethylene grafts. Ann Vasc Surg 2003; 17:401-407.
    • (2003) Ann Vasc Surg , vol.17 , pp. 401-407
    • Sala, F.1    Hassen-Khodja, R.2    Lecis, A.3    Bouillanne, P.J.4    Declemy, S.5    Batt, M.6
  • 64
    • 0036319650 scopus 로고    scopus 로고
    • Comparative evaluation of stretch and non-stretch polytetrafluorethylene (PTFE) prosthetic grafts for femoro-popliteal bypass
    • Lu CH, Chang J, Lai ST, Shin CC. Comparative evaluation of stretch and non-stretch polytetrafluorethylene (PTFE) prosthetic grafts for femoro-popliteal bypass. Zhonghua Yi Xue Za Zhi (Taipei) 2002;65:200-204.
    • (2002) Zhonghua Yi Xue Za Zhi (Taipei) , vol.65 , pp. 200-204
    • Lu, C.H.1    Chang, J.2    Lai, S.T.3    Shin, C.C.4
  • 65
    • 0034062207 scopus 로고    scopus 로고
    • Prosthetic above-knee femoropopliteal bypass grafting: Five-year results of a randomized trial
    • Green RM, Abbott WM, Matsumoto T, Wheeler JR, Miller N, Veith FJ, et al. Prosthetic above-knee femoropopliteal bypass grafting: five-year results of a randomized trial. J Vasc Surg 2000;31:417-425.
    • (2000) J Vasc Surg , vol.31 , pp. 417-425
    • Green, R.M.1    Abbott, W.M.2    Matsumoto, T.3    Wheeler, J.R.4    Miller, N.5    Veith, F.J.6
  • 66
    • 0036620041 scopus 로고    scopus 로고
    • Prosthetic grafts for above-knee femoropopliteal bypass. A multicenter retrospective study of 564 grafts
    • Miyazaki K, Nishibe T, Sata F, Miyazaki YI, Kudo FA, Flores J, et al. Prosthetic grafts for above-knee femoropopliteal bypass. A multicenter retrospective study of 564 grafts. Int Angiol 2002;21:145-151.
    • (2002) Int Angiol , vol.21 , pp. 145-151
    • Miyazaki, K.1    Nishibe, T.2    Sata, F.3    Miyazaki, Y.I.4    Kudo, F.A.5    Flores, J.6
  • 67
    • 0027515683 scopus 로고
    • Tibial bypass grafting for limb salvage with ringed polytetrafluoroethylene prostheses: Results of primary and secondary procedures
    • Schweiger H, Klein P, Lang W. Tibial bypass grafting for limb salvage with ringed polytetrafluoroethylene prostheses: results of primary and secondary procedures. J Vasc Surg 1993;18: 867-874.
    • (1993) J Vasc Surg , vol.18 , pp. 867-874
    • Schweiger, H.1    Klein, P.2    Lang, W.3
  • 68
    • 0035099052 scopus 로고    scopus 로고
    • Tibial bypass for limb salvage using polytetrafluoroethylene and a distal vein patch
    • Neville RF, Tempesta B, Sidway AN. Tibial bypass for limb salvage using polytetrafluoroethylene and a distal vein patch. J Vasc Surg 2001;33:266-271.
    • (2001) J Vasc Surg , vol.33 , pp. 266-271
    • Neville, R.F.1    Tempesta, B.2    Sidway, A.N.3
  • 69
    • 0033999638 scopus 로고    scopus 로고
    • Adjunctive techniques to improve patency of distal prosthetic bypass grafts: Polytetrafluoroethylene with remote arteriovenous fistulae versus vein cuffs
    • Kreienberg PB, Darling RC III, Chang BB, Paty PS, Lloyd WE, Shah DM. Adjunctive techniques to improve patency of distal prosthetic bypass grafts: polytetrafluoroethylene with remote arteriovenous fistulae versus vein cuffs. J Vasc Surg 2000;31:696-701.
    • (2000) J Vasc Surg , vol.31 , pp. 696-701
    • Kreienberg, P.B.1    Darling III, R.C.2    Chang, B.B.3    Paty, P.S.4    Lloyd, W.E.5    Shah, D.M.6
  • 70
    • 0033252608 scopus 로고    scopus 로고
    • Clinical and biological relevance of vein cuff anastomosis
    • Steinthorsson G, Sumpio B. Clinical and biological relevance of vein cuff anastomosis. Acta Chir Belg 1999;99:282-288.
    • (1999) Acta Chir Belg , vol.99 , pp. 282-288
    • Steinthorsson, G.1    Sumpio, B.2
  • 71
    • 0033984857 scopus 로고    scopus 로고
    • Vein interposition cuffs decrease the intimal hyperplastic response of polytetrafluoroethylene bypass grafts
    • Kissin M, Kansal N, Pappas PJ, DeFouw DO, Duran WN, Hobson RW. Vein interposition cuffs decrease the intimal hyperplastic response of polytetrafluoroethylene bypass grafts. J Vasc Surg 2000;31:69-83.
    • (2000) J Vasc Surg , vol.31 , pp. 69-83
    • Kissin, M.1    Kansal, N.2    Pappas, P.J.3    Defouw, D.O.4    Duran, W.N.5    Hobson, R.W.6
  • 72
    • 0034062272 scopus 로고    scopus 로고
    • Venous boot construction for a distal prosthetic bypass
    • Smout JD, Wolfe JH. Venous boot construction for a distal prosthetic bypass. Semin Vasc Surg 2000;13:53-57.
    • (2000) Semin Vasc Surg , vol.13 , pp. 53-57
    • Smout, J.D.1    Wolfe, J.H.2
  • 73
    • 0033636497 scopus 로고    scopus 로고
    • A comparative study of alternative conduits for lower extremity revascularization: All-autogenous conduit versus prosthetic grafts
    • Faries PL, Logerfo FW, Arora S, Hook S, Pulling MC, Akbari CM, et al. A comparative study of alternative conduits for lower extremity revascularization: all-autogenous conduit versus prosthetic grafts. J Vasc Surg 2000;32:1080-1090.
    • (2000) J Vasc Surg , vol.32 , pp. 1080-1090
    • Faries, P.L.1    Logerfo, F.W.2    Arora, S.3    Hook, S.4    Pulling, M.C.5    Akbari, C.M.6
  • 74
    • 0005767695 scopus 로고    scopus 로고
    • Clinical autologous in vitro endothelialization of infrainguinal ePTFE grafts in 100 patients: A 9-year experience
    • Deutsch M, Meinhart J, Fischlein T, Preiss P, Zilla P. Clinical autologous in vitro endothelialization of infrainguinal ePTFE grafts in 100 patients: a 9-year experience. Surgery 1999;126: 847-855.
    • (1999) Surgery , vol.126 , pp. 847-855
    • Deutsch, M.1    Meinhart, J.2    Fischlein, T.3    Preiss, P.4    Zilla, P.5
  • 76
    • 0036130724 scopus 로고    scopus 로고
    • Newly designed compliant hierarchic hybrid vascular graft wrapped with microprocessed elastomeric film-II: Morphogenesis and compliance change upon implantation
    • He H, Matsuda T. Newly designed compliant hierarchic hybrid vascular graft wrapped with microprocessed elastomeric film-II: morphogenesis and compliance change upon implantation. Cell Transplant 2002;11:75-87.
    • (2002) Cell Transplant , vol.11 , pp. 75-87
    • He, H.1    Matsuda, T.2
  • 77
    • 0030701944 scopus 로고    scopus 로고
    • Prospective randomized study of carbon-impregnated polytetrafluoroethylene grafts for below-knee popliteal and distal bypass: Results at 2 years
    • The Association Universitaire de Recherche en Chirurgie
    • Bacourt F. Prospective randomized study of carbon-impregnated polytetrafluoroethylene grafts for below-knee popliteal and distal bypass: results at 2 years. The Association Universitaire de Recherche en Chirurgie. Ann Vasc Surg 1997;11: 596-603.
    • (1997) Ann Vasc Surg , vol.11 , pp. 596-603
    • Bacourt, F.1
  • 78
    • 0036239873 scopus 로고    scopus 로고
    • Improving the clinical patency of prosthetic vascular and coronary bypass grafts: The role of seeding and tissue engineering
    • Seifalian AM, Tiwari A, Hamilton G, Salacinski HJ. Improving the clinical patency of prosthetic vascular and coronary bypass grafts: the role of seeding and tissue engineering. Artif Organs 2002;26:307-320.
    • (2002) Artif Organs , vol.26 , pp. 307-320
    • Seifalian, A.M.1    Tiwari, A.2    Hamilton, G.3    Salacinski, H.J.4
  • 79
    • 0035811268 scopus 로고    scopus 로고
    • Small-diameter compliant arterial graft prosthesis: Design concept of coaxial double tubular graft and its fabrication
    • Sonoda H, Takamizawa K, Nakayama Y, Yasui H, Matsuda T. Small-diameter compliant arterial graft prosthesis: Design concept of coaxial double tubular graft and its fabrication. J Biomed Mater Res 2001;55:266-276.
    • (2001) J Biomed Mater Res , vol.55 , pp. 266-276
    • Sonoda, H.1    Takamizawa, K.2    Nakayama, Y.3    Yasui, H.4    Matsuda, T.5
  • 82
    • 0345099652 scopus 로고    scopus 로고
    • Synthesis and evaluation of amphiphilic RGD derivatives: Uses for solvent casting in polymers and tissue engineering applications
    • Kidane AG, Salacinski HJ, Punshon G, Ramesh B, Srai KS, Seifalian AM. Synthesis and evaluation of amphiphilic RGD derivatives: uses for solvent casting in polymers and tissue engineering applications. Med Biol Eng Comput 2003;41: 740-745.
    • (2003) Med Biol Eng Comput , vol.41 , pp. 740-745
    • Kidane, A.G.1    Salacinski, H.J.2    Punshon, G.3    Ramesh, B.4    Srai, K.S.5    Seifalian, A.M.6
  • 84
    • 0242575847 scopus 로고    scopus 로고
    • Carotid bypass with polytetrafluoroethylene grafts: A study of 110 consecutive patients
    • Camiade C, Maher A, Ricco JB, Roumy J, Febrer G, Marchand C, et al. Carotid bypass with polytetrafluoroethylene grafts: a study of 110 consecutive patients. J Vasc Surg 2003; 38:1031-1037.
    • (2003) J Vasc Surg , vol.38 , pp. 1031-1037
    • Camiade, C.1    Maher, A.2    Ricco, J.B.3    Roumy, J.4    Febrer, G.5    Marchand, C.6
  • 85
    • 0036891016 scopus 로고    scopus 로고
    • Choice of material for internal carotid artery bypass grafting: Vein or prosthetic? Analysis of 44 procedures
    • Roddy SP, Darling RC III, Ozsvath KJ, Mehta M, Chang BB, Paty PS, et al. Choice of material for internal carotid artery bypass grafting: vein or prosthetic? Analysis of 44 procedures. Cardiovasc Surg 2002;10:540-544.
    • (2002) Cardiovasc Surg , vol.10 , pp. 540-544
    • Roddy, S.P.1    Darling III, R.C.2    Ozsvath, K.J.3    Mehta, M.4    Chang, B.B.5    Paty, P.S.6
  • 87
    • 0033146862 scopus 로고    scopus 로고
    • Experimental studies on application of small-caliber vascular prosthesis produced by polyurethane
    • Miyamoto K, Sugimoto T, Okada M, Maeda S. Experimental studies on application of small-caliber vascular prosthesis produced by polyurethane. Ann Thorac Cardiovasc Surg 1999;5: 174-181.
    • (1999) Ann Thorac Cardiovasc Surg , vol.5 , pp. 174-181
    • Miyamoto, K.1    Sugimoto, T.2    Okada, M.3    Maeda, S.4
  • 88
    • 0032170507 scopus 로고    scopus 로고
    • Bioengineering of a novel small diameter polyurethane vascular graft with covalently bound recombinant hirudin
    • Phaneuf MD, Dempsey DJ, Bide MJ, Szycher M, Quist WC, Logerfo FW. Bioengineering of a novel small diameter polyurethane vascular graft with covalently bound recombinant hirudin. ASAIO J 1998;44:M653-M658.
    • (1998) ASAIO J , vol.44
    • Phaneuf, M.D.1    Dempsey, D.J.2    Bide, M.J.3    Szycher, M.4    Quist, W.C.5    Logerfo, F.W.6
  • 90
    • 0033660328 scopus 로고    scopus 로고
    • Development of a prosthetic coronary artery bypass graft
    • Farrar DJ. Development of a prosthetic coronary artery bypass graft. Heart Surg Forum 2000;3:36-40.
    • (2000) Heart Surg Forum , vol.3 , pp. 36-40
    • Farrar, D.J.1
  • 92
    • 0023178619 scopus 로고
    • Aorta-coronary bypass grafting with polytetrafluoroethylene conduits. Early and late outcome in eight patients
    • Chard RB, Johnson DC, Nunn GR, Cartmill TB. Aorta-coronary bypass grafting with polytetrafluoroethylene conduits. Early and late outcome in eight patients. J Thorac Cardiovasc Surg 1987;94:132-134.
    • (1987) J Thorac Cardiovasc Surg , vol.94 , pp. 132-134
    • Chard, R.B.1    Johnson, D.C.2    Nunn, G.R.3    Cartmill, T.B.4
  • 93
    • 0027208136 scopus 로고
    • Very small-diameter polyurethane vascular prostheses with rapid endothelialization for coronary artery bypass grafting
    • Okoshi T, Soldani G, Goddard M, Galletti PM. Very small-diameter polyurethane vascular prostheses with rapid endothelialization for coronary artery bypass grafting. J Thorac Cardiovasc Surg 1993;105:791-795.
    • (1993) J Thorac Cardiovasc Surg , vol.105 , pp. 791-795
    • Okoshi, T.1    Soldani, G.2    Goddard, M.3    Galletti, P.M.4
  • 95
    • 0035108808 scopus 로고    scopus 로고
    • Heparin-bonded Dacron or polytetrafluoroethylene for femoropopliteal bypass grafting: A multicenter trial
    • Devine C, Hons B, McCollum C. Heparin-bonded Dacron or polytetrafluoroethylene for femoropopliteal bypass grafting: a multicenter trial. J Vasc Surg 2001;33:533-539.
    • (2001) J Vasc Surg , vol.33 , pp. 533-539
    • Devine, C.1    Hons, B.2    McCollum, C.3
  • 96
    • 0027684115 scopus 로고
    • Femoropopliteal bypass with a compliant, composite polyurethane/Dacron graft: Short-term results of a multicentre trial
    • Dereume JP, van Romphey A, Vincent G, Engelmann E. Femoropopliteal bypass with a compliant, composite polyurethane/Dacron graft: short-term results of a multicentre trial. Cardiovasc Surg 1993;1:499-503.
    • (1993) Cardiovasc Surg , vol.1 , pp. 499-503
    • Dereume, J.P.1    Van Romphey, A.2    Vincent, G.3    Engelmann, E.4
  • 97
    • 0141523105 scopus 로고    scopus 로고
    • Upper arm polytetrafluoroethylene grafts for dialysis access. Analysis of two different graft sizes: 6 mm and 6-8 mm
    • Garcia-Pajares R, Polo JR, Flores A, Gonzalez-Tabares E, Sous JV. Upper arm polytetrafluoroethylene grafts for dialysis access. Analysis of two different graft sizes: 6 mm and 6-8 mm. Vasc Endovascular Surg 2003;37:335-343.
    • (2003) Vasc Endovascular Surg , vol.37 , pp. 335-343
    • Garcia-Pajares, R.1    Polo, J.R.2    Flores, A.3    Gonzalez-Tabares, E.4    Sous, J.V.5
  • 98
    • 0029907427 scopus 로고    scopus 로고
    • Australian multicentre evaluation of a new polyurethane vascular access graft
    • Allen RD, Yuill E, Nankivell BJ, Francis DM. Australian multicentre evaluation of a new polyurethane vascular access graft. Aust N Z J Surg 1996;66:738-742.
    • (1996) Aust N Z J Surg , vol.66 , pp. 738-742
    • Allen, R.D.1    Yuill, E.2    Nankivell, B.J.3    Francis, D.M.4
  • 99
    • 0036192268 scopus 로고    scopus 로고
    • A polymeric sealant inhibits anastomotic suture hole bleeding more rapidly than gelfoam/thrombin: Results of a randomized controlled trial
    • Glickman M, Gheissari A, Money S, Martin J, Ballard JL. A polymeric sealant inhibits anastomotic suture hole bleeding more rapidly than gelfoam/thrombin: results of a randomized controlled trial. Arch Surg 2002;137:326-331.
    • (2002) Arch Surg , vol.137 , pp. 326-331
    • Glickman, M.1    Gheissari, A.2    Money, S.3    Martin, J.4    Ballard, J.L.5
  • 100
    • 0032076109 scopus 로고    scopus 로고
    • Aortocoronary bypass grafting with expanded polytetrafluoroethylene: 12-Year patency
    • McLarty AJ, Phillips MR, Holmes DR Jr, Schaff HV. Aortocoronary bypass grafting with expanded polytetrafluoroethylene: 12-year patency. Ann Thorac Surg 1998;65:1442-1444.
    • (1998) Ann Thorac Surg , vol.65 , pp. 1442-1444
    • McLarty, A.J.1    Phillips, M.R.2    Holmes Jr., D.R.3    Schaff, H.V.4
  • 101
    • 0000364326 scopus 로고
    • Single left coronary artery with fistula to right ventricle: Reconstruction of two-coronary system with dacron graft
    • Hallman G, Cooley Da, Mcnamara Dg, Latson JR. Single left coronary artery with fistula to right ventricle: reconstruction of two-coronary system with dacron graft. Circulation 1965;32: 293-297.
    • (1965) Circulation , vol.32 , pp. 293-297
    • Hallman, G.1    Cooley, Da.2    Mcnamara, Dg.3    Latson, J.R.4
  • 102
    • 0017138879 scopus 로고
    • Successful interposition synthetic graft between aorta and right coronary artery. Angiographic follow-up to sixteen months
    • Sauvage LR, Schloemer R, Wood SJ, Logan G. Successful interposition synthetic graft between aorta and right coronary artery. Angiographic follow-up to sixteen months. J Thorac Cardiovasc Surg 1976;72:418-421.
    • (1976) J Thorac Cardiovasc Surg , vol.72 , pp. 418-421
    • Sauvage, L.R.1    Schloemer, R.2    Wood, S.J.3    Logan, G.4
  • 103
    • 0018074297 scopus 로고
    • Aorta-coronary artery revascularization with an expanded polytetrafluoroethylene vascular graft. A preliminary report
    • Yokoyama T, Gharavi MA, Lee YC, Edmiston WA, Kay JH. Aorta-coronary artery revascularization with an expanded polytetrafluoroethylene vascular graft. A preliminary report. J Thorac Cardiovasc Surg 1978;76:552-555.
    • (1978) J Thorac Cardiovasc Surg , vol.76 , pp. 552-555
    • Yokoyama, T.1    Gharavi, M.A.2    Lee, Y.C.3    Edmiston, W.A.4    Kay, J.H.5
  • 105
    • 2442486679 scopus 로고    scopus 로고
    • Cellular engineering of conduits for coronary and lower limb bypass surgery: Role of cell attachment peptides and pre-conditioning in optimising smooth muscle cells (SMC) adherence to compliant poly(carbonate-urea)urethane (MyoLink) scaffolds
    • Rashid ST, Salacinski HJ, Button MJ, Fuller B, Hamilton G, Seifalian AM. Cellular engineering of conduits for coronary and lower limb bypass surgery: role of cell attachment peptides and pre-conditioning in optimising smooth muscle cells (SMC) adherence to compliant poly(carbonate-urea)urethane (MyoLink) scaffolds. Eur J Vasc Endovasc Surg 2004;27: 608-616.
    • (2004) Eur J Vasc Endovasc Surg , vol.27 , pp. 608-616
    • Rashid, S.T.1    Salacinski, H.J.2    Button, M.J.3    Fuller, B.4    Hamilton, G.5    Seifalian, A.M.6
  • 107
    • 0034234870 scopus 로고    scopus 로고
    • Clinical experience with autologous endothelial cell-seeded polytetrafluoroethylene coronary artery bypass grafts
    • Laube HR, Duwe J, Rutsch W, Konertz W. Clinical experience with autologous endothelial cell-seeded polytetrafluoroethylene coronary artery bypass grafts. J Thorac Cardiovasc Surg 2000;120:134-141.
    • (2000) J Thorac Cardiovasc Surg , vol.120 , pp. 134-141
    • Laube, H.R.1    Duwe, J.2    Rutsch, W.3    Konertz, W.4
  • 108
    • 0034997448 scopus 로고    scopus 로고
    • A new semi-automatic endothelial cell seeding technique for biological prosthetic heart valves
    • Laube HR, Matthaus M. A new semi-automatic endothelial cell seeding technique for biological prosthetic heart valves. Int J Artif Organs 2001;24:243-246.
    • (2001) Int J Artif Organs , vol.24 , pp. 243-246
    • Laube, H.R.1    Matthaus, M.2
  • 109
    • 0242458155 scopus 로고    scopus 로고
    • Arteriovenous PTFE dialysis access in the lower extremity: A new approach
    • Flarup S, Hadimeri H. Arteriovenous PTFE dialysis access in the lower extremity: a new approach. Ann Vasc Surg 2003; 17:581-584.
    • (2003) Ann Vasc Surg , vol.17 , pp. 581-584
    • Flarup, S.1    Hadimeri, H.2
  • 110
    • 0037286091 scopus 로고    scopus 로고
    • Evaluation of 4-mm to 7-mm versus 6-mm prosthetic brachial-antecubital forearm loop access for hemodialysis: Results of a randomized multicenter clinical trial
    • Dammers R, Planken RN, Pouls KP, Van Del RJ, Burger H, Van Der Sande FM, et al. Evaluation of 4-mm to 7-mm versus 6-mm prosthetic brachial-antecubital forearm loop access for hemodialysis: results of a randomized multicenter clinical trial. J Vasc Surg 2003;37:143-148.
    • (2003) J Vasc Surg , vol.37 , pp. 143-148
    • Dammers, R.1    Planken, R.N.2    Pouls, K.P.3    Van Del, R.J.4    Burger, H.5    Van Der Sande, F.M.6
  • 111
    • 0035488017 scopus 로고    scopus 로고
    • Vascular access survival and incidence of revisions: A comparison of prosthetic grafts, simple autogenous fistulas, and venous transposition fistulas from the United States Renal Data System Dialysis Morbidity and Mortality Study
    • Gibson KD, Gillen DL, Caps MT, Kohler TR, Sherrard DJ, Stehman-Breen CO. Vascular access survival and incidence of revisions: a comparison of prosthetic grafts, simple autogenous fistulas, and venous transposition fistulas from the United States Renal Data System Dialysis Morbidity and Mortality Study. J Vasc Surg 2001;34:694-700.
    • (2001) J Vasc Surg , vol.34 , pp. 694-700
    • Gibson, K.D.1    Gillen, D.L.2    Caps, M.T.3    Kohler, T.R.4    Sherrard, D.J.5    Stehman-Breen, C.O.6
  • 114
    • 0038137010 scopus 로고    scopus 로고
    • Retrospective study of the one-year patency of a cuffed polytetrafluoroethylene Venaflo-type graft placed for venous hemodialysis access
    • Berard X, Baste JC, Sassoust G, Du BL, Combe C, De PV, et al. Retrospective study of the one-year patency of a cuffed polytetrafluoroethylene Venaflo-type graft placed for venous hemodialysis access. J Mal Vasc 2003;28:73-78.
    • (2003) J Mal Vasc , vol.28 , pp. 73-78
    • Berard, X.1    Baste, J.C.2    Sassoust, G.3    Du, B.L.4    Combe, C.5    De, P.V.6
  • 115
    • 0036674280 scopus 로고    scopus 로고
    • Prospective, randomized evaluation of a cuffed expanded polytetrafluoroethylene graft for hemodialysis vascular access
    • Sorom AJ, Hughes CB, McCarthy JT, Jenson BM, Prieto M, Panneton JM, et al. Prospective, randomized evaluation of a cuffed expanded polytetrafluoroethylene graft for hemodialysis vascular access. Surgery 2002;132:135-140.
    • (2002) Surgery , vol.132 , pp. 135-140
    • Sorom, A.J.1    Hughes, C.B.2    McCarthy, J.T.3    Jenson, B.M.4    Prieto, M.5    Panneton, J.M.6
  • 116
    • 0038690560 scopus 로고    scopus 로고
    • Clinical and Doppler ultrasonography data of a polyurethane vascular access graft for haemodialysis: A prospective study
    • Wiese P, Blume J, Mueller HJ, Renner H, Nonnast-Daniel AB. Clinical and Doppler ultrasonography data of a polyurethane vascular access graft for haemodialysis: a prospective study. Nephrol Dial Transplant 2003;18:1397-1400.
    • (2003) Nephrol Dial Transplant , vol.18 , pp. 1397-1400
    • Wiese, P.1    Blume, J.2    Mueller, H.J.3    Renner, H.4    Nonnast-Daniel, A.B.5
  • 117
    • 0035284439 scopus 로고    scopus 로고
    • Coating of Dacron vascular grafts with an ionic polyurethane: A novel sealant with protein binding properties
    • Phaneuf MD, Dempsey DJ, Bide MJ, Quist WC, Logerfo FW. Coating of Dacron vascular grafts with an ionic polyurethane: a novel sealant with protein binding properties. Biomaterials 2001;22:463-469.
    • (2001) Biomaterials , vol.22 , pp. 463-469
    • Phaneuf, M.D.1    Dempsey, D.J.2    Bide, M.J.3    Quist, W.C.4    Logerfo, F.W.5
  • 118
    • 1242285575 scopus 로고    scopus 로고
    • Polyurethane grafts: A viable alternative for dialysis arteriovenous access?
    • Peng CW, Tan SG. Polyurethane grafts: a viable alternative for dialysis arteriovenous access? Asian Cardiovasc Thorac Ann 2003;11:314-318.
    • (2003) Asian Cardiovasc Thorac Ann , vol.11 , pp. 314-318
    • Peng, C.W.1    Tan, S.G.2
  • 119
    • 0242626559 scopus 로고    scopus 로고
    • Long-term follow-up of polyurethane vascular grafts for hemoaccess bridge fistulas
    • Kiyama H, Imazeki T, Kurihara S, Yoneshima H. Long-term follow-up of polyurethane vascular grafts for hemoaccess bridge fistulas. Ann Vasc Surg 2003;17:516-521.
    • (2003) Ann Vasc Surg , vol.17 , pp. 516-521
    • Kiyama, H.1    Imazeki, T.2    Kurihara, S.3    Yoneshima, H.4
  • 120
    • 1842812867 scopus 로고    scopus 로고
    • New alternatives in management of the infected vascular prosthesis
    • Wilson SE. New alternatives in management of the infected vascular prosthesis. Surg Infect (Larchmt) 2001;2: 171-175.
    • (2001) Surg Infect (Larchmt) , vol.2 , pp. 171-175
    • Wilson, S.E.1
  • 122
    • 0036275769 scopus 로고    scopus 로고
    • Performance of a polyurethane vascular prosthesis carrying a dipyridamole (Persantin) coating on its lumenal surface
    • Salacinski H, Tiwari A, Hamilton G, Seifalian AM. Performance of a polyurethane vascular prosthesis carrying a dipyridamole (Persantin) coating on its lumenal surface. J Biomed Mater Res 2002;61:337-338.
    • (2002) J Biomed Mater Res , vol.61 , pp. 337-338
    • Salacinski, H.1    Tiwari, A.2    Hamilton, G.3    Seifalian, A.M.4
  • 123
    • 0344065977 scopus 로고    scopus 로고
    • Surface functionalization and grafting of heparin and/or RGD by an aqueous-based process to a poly(carbonate-urea)urethane cardiovascular graft for cellular engineering applications
    • Salacinski HJ, Hamilton G, Seifalian AM. Surface functionalization and grafting of heparin and/or RGD by an aqueous-based process to a poly(carbonate-urea)urethane cardiovascular graft for cellular engineering applications. J Biomed Mater Res 2003;66A:688-697.
    • (2003) J Biomed Mater Res , vol.66 A , pp. 688-697
    • Salacinski, H.J.1    Hamilton, G.2    Seifalian, A.M.3
  • 124
    • 0036027341 scopus 로고    scopus 로고
    • Vascularisation of tissue-engineered grafts: The regulation of angiogenesis in reconstructive surgery and in disease states
    • Cassell OC, Hofer SO, Morrison WA, Knight KR. Vascularisation of tissue-engineered grafts: the regulation of angiogenesis in reconstructive surgery and in disease states. Br J Plast Surg 2002;55:603-610.
    • (2002) Br J Plast Surg , vol.55 , pp. 603-610
    • Cassell, O.C.1    Hofer, S.O.2    Morrison, W.A.3    Knight, K.R.4
  • 125
    • 0033767249 scopus 로고    scopus 로고
    • Optimal endothelialisation of a new compliant poly(carbonate-urea) urethane vascular graft with effect of physiological shear stress
    • Salacinski HJ, Tai NR, Punshon G, Giudiceandrea A, Hamilton G, Seifalian AM. Optimal endothelialisation of a new compliant poly(carbonate-urea)urethane vascular graft with effect of physiological shear stress. Eur J Vasc Endovasc Surg 2000;20:342-352.
    • (2000) Eur J Vasc Endovasc Surg , vol.20 , pp. 342-352
    • Salacinski, H.J.1    Tai, N.R.2    Punshon, G.3    Giudiceandrea, A.4    Hamilton, G.5    Seifalian, A.M.6
  • 126
    • 0035698127 scopus 로고    scopus 로고
    • A hybrid compliant vascular graft seeded with microvascular endothelial cells extracted from human omentum
    • Salacinski HJ, Punshon G, Krijgsman B, Hamilton G, Seifalian AM. A hybrid compliant vascular graft seeded with microvascular endothelial cells extracted from human omentum. Artif Organs 2001;25:974-982.
    • (2001) Artif Organs , vol.25 , pp. 974-982
    • Salacinski, H.J.1    Punshon, G.2    Krijgsman, B.3    Hamilton, G.4    Seifalian, A.M.5
  • 127
    • 0042884461 scopus 로고    scopus 로고
    • Accelerated endothelialization of interpositional 1-mm vascular grafts
    • Kidd KR, Patula VB, Williams SK. Accelerated endothelialization of interpositional 1-mm vascular grafts. J Surg Res 2003;113:234-242.
    • (2003) J Surg Res , vol.113 , pp. 234-242
    • Kidd, K.R.1    Patula, V.B.2    Williams, S.K.3
  • 128
    • 0031593229 scopus 로고    scopus 로고
    • Elastic protein-based materials in tissue reconstruction
    • Urry DW, Pattanaik A. Elastic protein-based materials in tissue reconstruction. Ann N Y Acad Sci 1997;831:32-46.
    • (1997) Ann N Y Acad Sci , vol.831 , pp. 32-46
    • Urry, D.W.1    Pattanaik, A.2
  • 129
    • 0031761677 scopus 로고    scopus 로고
    • Two-dimensional manipulation of confluently cultured vascular endothelial cells using temperature-responsive poly(N-isopropylacrylamide)-grafted surfaces
    • Kikuchi A, Okuhara M, Karikusa F, Sakurai Y, Okano T. Two-dimensional manipulation of confluently cultured vascular endothelial cells using temperature-responsive poly(N-isopropylacrylamide)-grafted surfaces. J Biomater Sci Polym Ed 1998;9:1331-1348.
    • (1998) J Biomater Sci Polym Ed , vol.9 , pp. 1331-1348
    • Kikuchi, A.1    Okuhara, M.2    Karikusa, F.3    Sakurai, Y.4    Okano, T.5
  • 130
    • 0036284611 scopus 로고    scopus 로고
    • New prostheses for use in bypass grafts with special emphasis on polyurethanes
    • Tiwari A, Salacinski H, Seifalian AM, Hamilton G. New prostheses for use in bypass grafts with special emphasis on polyurethanes. Cardiovasc Surg 2002;10:191-197.
    • (2002) Cardiovasc Surg , vol.10 , pp. 191-197
    • Tiwari, A.1    Salacinski, H.2    Seifalian, A.M.3    Hamilton, G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.