메뉴 건너뛰기




Volumn 65, Issue 3, 2003, Pages 363-368

A long term comparison between Denacol® EX-313-treated bovine jugular vein graft and ultrafine polyester fiber graft for reconstruction of right ventricular outflow tract in dogs

Author keywords

Canine; Denacol EX 313; Patch graft; Pulmonic stenosis; Ultrafine polyester fiber

Indexed keywords

BOVINAE; CANIS FAMILIARIS;

EID: 0037643305     PISSN: 09167250     EISSN: 13477439     Source Type: Journal    
DOI: 10.1292/jvms.65.363     Document Type: Article
Times cited : (6)

References (15)
  • 1
    • 0023870406 scopus 로고
    • A decade of experience with the glutaraldehyde-tanned human umbilical cord vein graft for revascularization of the lower limb
    • Dardik, H., Miller, N., Dardik, A., Ibrahim, I., Sussman, B., Berry, S. M., Wolodiger, F., Kahn, M. and Dardik, I. 1988. A decade of experience with the glutaraldehyde-tanned human umbilical cord vein graft for revascularization of the lower limb. J. Vasc. Surg. 7: 336-346.
    • (1988) J. Vasc. Surg. , vol.7 , pp. 336-346
    • Dardik, H.1    Miller, N.2    Dardik, A.3    Ibrahim, I.4    Sussman, B.5    Berry, S.M.6    Wolodiger, F.7    Kahn, M.8    Dardik, I.9
  • 2
    • 0030758617 scopus 로고    scopus 로고
    • Use of a bovine jugular vein graft with natural valve for right ventricular outflow tract reconstruction: A one-year animal study
    • Ichikawa, Y., Noishiki, Y., Kosuge, T., Yamamoto, K., Kondo, J. and Matsumoto, A. 1997. Use of a bovine jugular vein graft with natural valve for right ventricular outflow tract reconstruction: a one-year animal study. J. Thorac. Cardiovasc. Surg. 114: 224-233.
    • (1997) J. Thorac. Cardiovasc. Surg. , vol.114 , pp. 224-233
    • Ichikawa, Y.1    Noishiki, Y.2    Kosuge, T.3    Yamamoto, K.4    Kondo, J.5    Matsumoto, A.6
  • 5
    • 0021804710 scopus 로고
    • Wrapped-knitted Dacron and microporous EPTFE conduits for reconstruction of right ventricular outflow tract
    • Matsumoto, H., Miyawaki, F., Takayama, T. and Asano, K. 1985. Wrapped-knitted Dacron and microporous EPTFE conduits for reconstruction of right ventricular outflow tract. Jpn. J. Surg. 15: 249-253.
    • (1985) Jpn. J. Surg. , vol.15 , pp. 249-253
    • Matsumoto, H.1    Miyawaki, F.2    Takayama, T.3    Asano, K.4
  • 6
    • 0035465265 scopus 로고    scopus 로고
    • Experimental study of materials for patch graft on right ventricular outflow tract under extracorporeal circulation in dogs - Comparison between DenacolR EX-313-treated bovine jugular vein graft and expanded polytetrafluoroethylene (EPTFE) graft
    • Matsumoto, H., Sugiyama, S., Shibazaki, A., Tanaka, R., Takashima, K., Noishiki, Y. and Yamane, Y. 2001. Experimental study of materials for patch graft on right ventricular outflow tract under extracorporeal circulation in dogs - comparison between DenacolR EX-313-treated bovine jugular vein graft and expanded polytetrafluoroethylene (EPTFE) graft. J. Vet. Med. Sci. 63: 961-965.
    • (2001) J. Vet. Med. Sci. , vol.63 , pp. 961-965
    • Matsumoto, H.1    Sugiyama, S.2    Shibazaki, A.3    Tanaka, R.4    Takashima, K.5    Noishiki, Y.6    Yamane, Y.7
  • 7
    • 0022755723 scopus 로고
    • Development of a small Caliber vascular graft by a new crosslinking method incorporating slow heparin release collagen and natural tissue compliance
    • Noishiki, Y., Miyata, T. and Kodaira, K. 1986. Development of a small Caliber vascular graft by a new crosslinking method incorporating slow heparin release collagen and natural tissue compliance. Trans. Am. Soc. Artif. Int. Organs. 32: 114-119.
    • (1986) Trans. Am. Soc. Artif. Int. Organs. , vol.32 , pp. 114-119
    • Noishiki, Y.1    Miyata, T.2    Kodaira, K.3
  • 9
    • 3042949002 scopus 로고
    • Alcohol-preserved homologous connective tissue tubes for arterial grafts
    • in Japanese with English summary
    • Noishiki, Y. and Yamane, Y. 1976. Alcohol-preserved homologous connective tissue tubes for arterial grafts. Jpn. J. Artif. Organs. 5: 332-335 (in Japanese with English summary).
    • (1976) Jpn. J. Artif. Organs. , vol.5 , pp. 332-335
    • Noishiki, Y.1    Yamane, Y.2
  • 10
    • 0025397581 scopus 로고
    • An open patch-graft technique for correction of pulmonic stenosis in the dog
    • Orton, E. C., Bruecker, K. A. and McCracken, T. O. 1990. An open patch-graft technique for correction of pulmonic stenosis in the dog. Vet. Surg. 19: 148-154.
    • (1990) Vet. Surg. , vol.19 , pp. 148-154
    • Orton, E.C.1    Bruecker, K.A.2    McCracken, T.O.3
  • 12
    • 0033109478 scopus 로고    scopus 로고
    • A comparative study between hypothermic and normothermic cardiopulmonary bypass in open heart surgery in dogs - Effects on systemic hemodynamics
    • Shibazaki, A., Matsumoto, H., Shiroshita, Y., Noishiki, Y. and Yamane, Y. 1999. A comparative study between hypothermic and normothermic cardiopulmonary bypass in open heart surgery in dogs - Effects on systemic hemodynamics -. J. Vet. Med. Sci. 61: 331-336.
    • (1999) J. Vet. Med. Sci. , vol.61 , pp. 331-336
    • Shibazaki, A.1    Matsumoto, H.2    Shiroshita, Y.3    Noishiki, Y.4    Yamane, Y.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.