메뉴 건너뛰기




Volumn 42, Issue 8, 2003, Pages 1370-1372

Percutaneous Treatment of Saphenous Vein Graft Disease: The Ongoing Challenge

Author keywords

[No Author keywords available]

Indexed keywords

ANGINA PECTORIS; ATHEROSCLEROSIS; CATHETER; CLINICAL FEATURE; CORONARY ARTERY BYPASS GRAFT; CORONARY ARTERY PERFORATION; DEVICE; DISEASE COURSE; EDITORIAL; HEART INFARCTION; HUMAN; PRIORITY JOURNAL; RECURRENT DISEASE; REDUCTION; RISK FACTOR; SAPHENOUS VEIN GRAFT; SURGICAL TECHNIQUE; THORAX PAIN; VEIN DISEASE; VEIN GRAFT; VEIN GRAFT DISEASE;

EID: 0142043905     PISSN: 07351097     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0735-1097(03)01039-8     Document Type: Editorial
Times cited : (49)

References (16)
  • 1
    • 0037021564 scopus 로고    scopus 로고
    • Percutaneous coronary intervention versus repeat bypass surgery for patients with medically refractory myocardial ischemia: AWESOME randomized trial and registry experience for post-CABG patients
    • Morrison DS, Sethi G, Sacks J, et al. Percutaneous coronary intervention versus repeat bypass surgery for patients with medically refractory myocardial ischemia: AWESOME randomized trial and registry experience for post-CABG patients. J Am Coll Cardiol 2002;40:1951-4.
    • (2002) J Am Coll Cardiol , vol.40 , pp. 1951-1954
    • Morrison, D.S.1    Sethi, G.2    Sacks, J.3
  • 2
    • 0034969429 scopus 로고    scopus 로고
    • Are we making progress with percutaneous vein graft treatment? A comparison of 1990 to 1994 and 1995 to 1998 results
    • Hong MK, Mehran R, Mintz GS, et al. Are we making progress with percutaneous vein graft treatment? A comparison of 1990 to 1994 and 1995 to 1998 results. J Am Coll Cardiol 2001;38:150-4.
    • (2001) J Am Coll Cardiol , vol.38 , pp. 150-154
    • Hong, M.K.1    Mehran, R.2    Mintz, G.S.3
  • 3
    • 0034846608 scopus 로고    scopus 로고
    • Long-term clinical outcome and predictors of major adverse cardiac events after percutaneous interventions on saphenous vein grafts
    • Keeley EC, Velez CA, O'Neill WW, Safian RD. Long-term clinical outcome and predictors of major adverse cardiac events after percutaneous interventions on saphenous vein grafts. J Am Coll Cardiol 2001;38:659-65.
    • (2001) J Am Coll Cardiol , vol.38 , pp. 659-665
    • Keeley, E.C.1    Velez, C.A.2    O'Neill, W.W.3    Safian, R.D.4
  • 4
    • 0036467897 scopus 로고    scopus 로고
    • A trial comparing rheolytic thrombectomy with intracoronary urokinase for coronary and vein graft thrombus (The Vein Graft AngioJet Study [VeGAS 2])
    • Kuntz RE, Baim DS, Cohen DJ, et al., for the VeGAS 2 Investigators. A trial comparing rheolytic thrombectomy with intracoronary urokinase for coronary and vein graft thrombus (The Vein Graft Angiojet Study [VeGAS 2]). Am J Cardiol 2002;89:326-30.
    • (2002) Am J Cardiol , vol.89 , pp. 326-330
    • Kuntz, R.E.1    Baim, D.S.2    Cohen, D.J.3
  • 5
    • 12244299832 scopus 로고    scopus 로고
    • Safety and efficacy of a novel device for treatment of thrombotic and atherosclerotic lesion in native coronary arteries and saphenous vein grafts: Results from the multicenter X-sizer for treatment of thrombus and atherosclerosis in coronary applications trial (X-TRACT) study
    • Stone GW, Cox DA, Low R, et al. Safety and efficacy of a novel device for treatment of thrombotic and atherosclerotic lesion in native coronary arteries and saphenous vein grafts: results from the multicenter X-sizer for treatment of thrombus and atherosclerosis in coronary applications trial (X-TRACT) study. Cathet Cardiovasc Interv 2003;58:419-27.
    • (2003) Cathet Cardiovasc Interv , vol.58 , pp. 419-427
    • Stone, G.W.1    Cox, D.A.2    Low, R.3
  • 6
    • 0032786887 scopus 로고    scopus 로고
    • Creatine kinase-MB enzyme elevation following successful saphenous vein graft intervention is associated with late mortality
    • Hong MK, Mehran R, Dangas G, et al. Creatine kinase-MB enzyme elevation following successful saphenous vein graft intervention is associated with late mortality. Circulation 1999;100:2400-5.
    • (1999) Circulation , vol.100 , pp. 2400-2405
    • Hong, M.K.1    Mehran, R.2    Dangas, G.3
  • 7
    • 0028232692 scopus 로고
    • Incidence and treatment of "no-reflow" after percutaneous coronary intervention
    • Piana RN, Paik GY, Moscucci M, et al. Incidence and treatment of "no-reflow" after percutaneous coronary intervention. Circulation 1994;89:2514-8.
    • (1994) Circulation , vol.89 , pp. 2514-2518
    • Piana, R.N.1    Paik, G.Y.2    Moscucci, M.3
  • 8
    • 0032533589 scopus 로고    scopus 로고
    • Reduction in complications of angioplasty with abciximab occurs largely independently of baseline lesion morphology
    • Ellis SG, Linkoff AM, Miller D, et al. Reduction in complications of angioplasty with abciximab occurs largely independently of baseline lesion morphology. J Am Coll Cardiol 1998;32:1619-23.
    • (1998) J Am Coll Cardiol , vol.32 , pp. 1619-1623
    • Ellis, S.G.1    Linkoff, A.M.2    Miller, D.3
  • 9
    • 0037133682 scopus 로고    scopus 로고
    • Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts
    • Baim DS, Wahr D, George B, et al., on behalf of the Saphenous vein graft Angioplasty Free of Emboli Randomized (SAFER) Trial Investigators. Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts. Circulation 2002;105:1285-90.
    • (2002) Circulation , vol.105 , pp. 1285-1290
    • Baim, D.S.1    Wahr, D.2    George, B.3
  • 10
    • 0043075814 scopus 로고    scopus 로고
    • Randomized comparison of distal protection with a filter-based catheter and a balloon occlusion and aspiration system during percutaneous intervention of diseased saphenous vein aorto-coronary bypass grafts
    • Stone GW, Rogers C, Hermiller J, et al. Randomized comparison of distal protection with a filter-based catheter and a balloon occlusion and aspiration system during percutaneous intervention of diseased saphenous vein aorto-coronary bypass grafts. Circulation 2003;108: 548-53.
    • (2003) Circulation , vol.108 , pp. 548-553
    • Stone, G.W.1    Rogers, C.2    Hermiller, J.3
  • 11
    • 0030273583 scopus 로고    scopus 로고
    • Long-term (4-6 year) outcome after Palmaz-Schatz stenting - Paucity of late stent-related problems
    • Laham RJ, Carrozza JP, Berger C, Cohen DJ, Kuntz RE, Baim DS. Long-term (4-6 year) outcome after Palmaz-Schatz stenting - paucity of late stent-related problems. J Am Coll Cardiol 1996;28: 820-6.
    • (1996) J Am Coll Cardiol , vol.28 , pp. 820-826
    • Laham, R.J.1    Carrozza, J.P.2    Berger, C.3    Cohen, D.J.4    Kuntz, R.E.5    Baim, D.S.6
  • 12
    • 0030967488 scopus 로고    scopus 로고
    • Late myocardial ischemic events after saphenous vein graft intervention - Importance of initially "non-significant" vein graft lesions
    • Ellis SG, Brener SJ, De Luca S, et al. Late myocardial ischemic events after saphenous vein graft intervention - importance of initially "non-significant" vein graft lesions. Am J Cardiol 1997;79:1460-4.
    • (1997) Am J Cardiol , vol.79 , pp. 1460-1464
    • Ellis, S.G.1    Brener, S.J.2    De Luca, S.3
  • 13
    • 0037129429 scopus 로고    scopus 로고
    • Intravascular gamma radiation for in-stent restenosis in saphenous-vein bypass grafts
    • Waksman R, White RL, Chan RC, et al. Intravascular gamma radiation for in-stent restenosis in saphenous-vein bypass grafts. N Engl J Med 2002;346:1194-9.
    • (2002) N Engl J Med , vol.346 , pp. 1194-1199
    • Waksman, R.1    White, R.L.2    Chan, R.C.3
  • 15
    • 10744222369 scopus 로고    scopus 로고
    • A randomized trial of polytetrafluoroethylene-membrane covered stents compared with conventional stents in aortocoronary saphenous vein grafts
    • Schächinger V, Hamm CW, Munzel T, et al. A randomized trial of polytetrafluoroethylene-membrane covered stents compared with conventional stents in aortocoronary saphenous vein grafts. J Am Coll Cardiol 2003;42:1360-9.
    • (2003) J Am Coll Cardiol , vol.42 , pp. 1360-1369
    • Schächinger, V.1    Hamm, C.W.2    Munzel, T.3
  • 16
    • 0038164591 scopus 로고    scopus 로고
    • Randomized evaluation of polytetrafluoroethylene-covered stent in saphenous vein grafts: The Randomized Evaluation of polytetrafluoroethylene COVERed stent in Saphenous vein grafts (RECOVERS) trial
    • Stankovic G, Colombo A, Presbitero P, et al. Randomized evaluation of polytetrafluoroethylene-covered stent in saphenous vein grafts: the Randomized Evaluation of polytetrafluoroethylene COVERed stent in Saphenous vein grafts (RECOVERS) trial. Circulation 2003;108:37-42.
    • (2003) Circulation , vol.108 , pp. 37-42
    • Stankovic, G.1    Colombo, A.2    Presbitero, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.