메뉴 건너뛰기




Volumn 82, Issue 6, 2005, Pages 467-472

Beyond flux: Total corneal oxygen consumption as an index of corneal oxygenation during contact lens wear

Author keywords

Contact lens; Cornea; Oxygen consumption; Oxygen transmissibility; Silicone hydrogel

Indexed keywords

APPROXIMATION THEORY; DIFFUSION; METABOLISM; OXYGEN; PRESSURE EFFECTS; THICKNESS MEASUREMENT; WEAR OF MATERIALS;

EID: 21344464651     PISSN: 10405488     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.opx.0000168560.10861.ae     Document Type: Article
Times cited : (68)

References (35)
  • 1
    • 77049212617 scopus 로고
    • Physiologicalchanges in cornea induced by contact lenses
    • Smelser GK, Chen DK. Physiologicalchanges in cornea induced by contact lenses. AMAArch Ophthalmol 1955;53:676-9.
    • (1955) AMAArch Ophthalmol , vol.53 , pp. 676-679
    • Smelser, G.K.1    Chen, D.K.2
  • 2
    • 0025039785 scopus 로고
    • Corneal pathophysiology with contact lens wear
    • Bruce AS, Brennan NA. Corneal pathophysiology with contact lens wear. Surv Ophthalmol 1990;35:25-58.
    • (1990) Surv Ophthalmol , vol.35 , pp. 25-58
    • Bruce, A.S.1    Brennan, N.A.2
  • 3
    • 0003956480 scopus 로고    scopus 로고
    • Edinburgh: Butterworth-Heinemann
    • nd ed. Edinburgh: Butterworth-Heinemann; 2004.
    • (2004) nd Ed.
    • Efron, N.1
  • 4
    • 0030067863 scopus 로고    scopus 로고
    • New physiological paradigms to assess the effect of lens oxygen transmissibility on corneal health
    • Fatt I. New physiological paradigms to assess the effect of lens oxygen transmissibility on corneal health. CLAO J 1996;22:25-9.
    • (1996) CLAO J , vol.22 , pp. 25-29
    • Fatt, I.1
  • 5
    • 0035159141 scopus 로고    scopus 로고
    • A model of oxygen flux through contact lenses
    • Brennan NA. A model of oxygen flux through contact lenses. Cornea 2001;20:104-8.
    • (2001) Cornea , vol.20 , pp. 104-108
    • Brennan, N.A.1
  • 6
    • 0142258103 scopus 로고    scopus 로고
    • Biological oxygen apparent transmissibility of hydrogel contact lenses with and without organosilicon moieties
    • Compan V, Lopez-Alemany A, Riande E, Refojo MF. Biological oxygen apparent transmissibility of hydrogel contact lenses with and without organosilicon moieties. Biomaterials 2004;25:359-65.
    • (2004) Biomaterials , vol.25 , pp. 359-365
    • Compan, V.1    Lopez-Alemany, A.2    Riande, E.3    Refojo, M.F.4
  • 8
    • 0014304897 scopus 로고
    • Steady-state distribution of oxygen and carbon dioxide in the in vivo cornea. II. The open eye in nitrogen and the covered eye
    • Fatt I. Steady-state distribution of oxygen and carbon dioxide in the in vivo cornea. II. The open eye in nitrogen and the covered eye. Exp Eye Res 1968;7:413-30.
    • (1968) Exp Eye Res , vol.7 , pp. 413-430
    • Fatt, I.1
  • 9
    • 0016190287 scopus 로고
    • Oxygen tension distributions in the cornea: A re-examination
    • Fatt I, Freeman RD, Lin D. Oxygen tension distributions in the cornea: a re-examination. Exp Eye Res 1974;18:357-65.
    • (1974) Exp Eye Res , vol.18 , pp. 357-365
    • Fatt, I.1    Freeman, R.D.2    Lin, D.3
  • 10
    • 0032843148 scopus 로고    scopus 로고
    • Re-evaluation of the oxygen diffusion model for predicting minimum contact lens Dk/t values needed to avoid corneal anoxia
    • Harvitt DM, Bonanno JA. Re-evaluation of the oxygen diffusion model for predicting minimum contact lens Dk/t values needed to avoid corneal anoxia. Optom Vis Sci 1999;76:712-9.
    • (1999) Optom Vis Sci , vol.76 , pp. 712-719
    • Harvitt, D.M.1    Bonanno, J.A.2
  • 11
    • 18344393472 scopus 로고    scopus 로고
    • Corneal oxygenation during contact lens wear: Comparison of diffusion and EOP-based flux models
    • Brennan N. Corneal oxygenation during contact lens wear: comparison of diffusion and EOP-based flux models. Clin Exp Optom 2005; 88:103-8.
    • (2005) Clin Exp Optom , vol.88 , pp. 103-108
    • Brennan, N.1
  • 13
    • 0034603359 scopus 로고    scopus 로고
    • Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach
    • Doughty MJ, Zaman ML. Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol 2000;44:367-408.
    • (2000) Surv Ophthalmol , vol.44 , pp. 367-408
    • Doughty, M.J.1    Zaman, M.L.2
  • 14
    • 0034972703 scopus 로고    scopus 로고
    • Effects of rigid and soft contact lens daily wear on corneal epithelium, tear lactate dehydrogenase, and bacterial binding to exfoliated epithelial cells
    • Ladage PM, Yamamoto K, Ren DH, Li L, Jester JV, Petroll WM, Cavanagh HD. Effects of rigid and soft contact lens daily wear on corneal epithelium, tear lactate dehydrogenase, and bacterial binding to exfoliated epithelial cells. Ophthalmology 2001;108:1279-88.
    • (2001) Ophthalmology , vol.108 , pp. 1279-1288
    • Ladage, P.M.1    Yamamoto, K.2    Ren, D.H.3    Li, L.4    Jester, J.V.5    Petroll, W.M.6    Cavanagh, H.D.7
  • 15
    • 0036841035 scopus 로고    scopus 로고
    • Effects of daily and overnight wear of a novel hyper oxygen-transmissible soft contact lens on bacterial binding and corneal epithelium: A 13-month clinical trial
    • Cavanagh HD, Ladage PM, Li SL, Yamamoto K, Molai M, Ren DH, Petroll WM, Jester JV. Effects of daily and overnight wear of a novel hyper oxygen-transmissible soft contact lens on bacterial binding and corneal epithelium: a 13-month clinical trial. Ophthalmology 2002; 109:1957-69.
    • (2002) Ophthalmology , vol.109 , pp. 1957-1969
    • Cavanagh, H.D.1    Ladage, P.M.2    Li, S.L.3    Yamamoto, K.4    Molai, M.5    Ren, D.H.6    Petroll, W.M.7    Jester, J.V.8
  • 16
    • 0036181034 scopus 로고    scopus 로고
    • The measurement of corneal epithelial thickness in response to hypoxia using optical coherence tomography
    • Wang J, Fonn D, Simpson TL, Jones L. The measurement of corneal epithelial thickness in response to hypoxia using optical coherence tomography. Am J Ophthalmol 2002;133:315-9.
    • (2002) Am J Ophthalmol , vol.133 , pp. 315-319
    • Wang, J.1    Fonn, D.2    Simpson, T.L.3    Jones, L.4
  • 17
    • 0037247550 scopus 로고    scopus 로고
    • Thickness of the pre- and post-contact lens tear film measured in vivo by interferometry
    • Nichols JJ, King-Smith PE. Thickness of the pre- and post-contact lens tear film measured in vivo by interferometry. Invest Ophthalmol Vis Sci 2003;44:68-77.
    • (2003) Invest Ophthalmol Vis Sci , vol.44 , pp. 68-77
    • Nichols, J.J.1    King-Smith, P.E.2
  • 18
    • 0037986535 scopus 로고    scopus 로고
    • Corneal epithelial thinning profile induced by long-term wear of hydrogel lenses
    • Perez JG, Meijome JM, Jalbert I, Sweeney DF, Erickson P. Corneal epithelial thinning profile induced by long-term wear of hydrogel lenses. Cornea 2003;22:304-7.
    • (2003) Cornea , vol.22 , pp. 304-307
    • Perez, J.G.1    Meijome, J.M.2    Jalbert, I.3    Sweeney, D.F.4    Erickson, P.5
  • 19
    • 0037809437 scopus 로고    scopus 로고
    • Precorneal and pre- and postlens tear film thickness measured indirectly with optical coherence tomography
    • Wang J, Fonn D, Simpson TL, Jones L. Precorneal and pre- and postlens tear film thickness measured indirectly with optical coherence tomography. Invest Ophthalmol Vis Sci 2003;44:2524-8.
    • (2003) Invest Ophthalmol Vis Sci , vol.44 , pp. 2524-2528
    • Wang, J.1    Fonn, D.2    Simpson, T.L.3    Jones, L.4
  • 21
    • 0023869404 scopus 로고
    • The oxygen dependence of mitochondrial oxidative phosphorylation measured by a new optical method for measuring oxygen concentration
    • Wilson DF, Rumsey WL, Green TJ, Vanderkooi JM. The oxygen dependence of mitochondrial oxidative phosphorylation measured by a new optical method for measuring oxygen concentration. J Biol Chem 1988;263:2712-8.
    • (1988) J Biol Chem , vol.263 , pp. 2712-2718
    • Wilson, D.F.1    Rumsey, W.L.2    Green, T.J.3    Vanderkooi, J.M.4
  • 22
    • 0035155343 scopus 로고    scopus 로고
    • Bioenergetics at low oxygen: Dependence of respiration and phosphorylation on oxygen and adenosine diphosphate supply
    • Gnaiger E. Bioenergetics at low oxygen: dependence of respiration and phosphorylation on oxygen and adenosine diphosphate supply. Respir Physiol 2001;128:277-97.
    • (2001) Respir Physiol , vol.128 , pp. 277-297
    • Gnaiger, E.1
  • 24
    • 0023780579 scopus 로고
    • Time course of corneal oxygen uptake during contact lens wear
    • Carney LG, Brennan NA. Time course of corneal oxygen uptake during contact lens wear. CLAO J 1988;14:151-4.
    • (1988) CLAO J , vol.14 , pp. 151-154
    • Carney, L.G.1    Brennan, N.A.2
  • 25
    • 0036157050 scopus 로고    scopus 로고
    • Estimation of human corneal oxygen consumption by non-invasive measurement of tear oxygen tension while wearing hydrogel lenses
    • Bonanno JA, Stickel T, Nguyen T, Biehl T, Carter D, Benjamin WJ, Soni PS. Estimation of human corneal oxygen consumption by non-invasive measurement of tear oxygen tension while wearing hydrogel lenses. Invest Ophthalmol Vis Sci 2002;43:371-6.
    • (2002) Invest Ophthalmol Vis Sci , vol.43 , pp. 371-376
    • Bonanno, J.A.1    Stickel, T.2    Nguyen, T.3    Biehl, T.4    Carter, D.5    Benjamin, W.J.6    Soni, P.S.7
  • 26
    • 21344450809 scopus 로고    scopus 로고
    • Corneal oxygen consumption and hypoxia
    • Bennett ES, Weissman BA, eds. Philadelphia: Lippincott Williams & Wilkins
    • Brennan N, Efron N. Corneal oxygen consumption and hypoxia. In: Bennett ES, Weissman BA, eds. Clinical Contact Lens Practice. Philadelphia: Lippincott Williams & Wilkins; 2004:41-66.
    • (2004) Clinical Contact Lens Practice , pp. 41-66
    • Brennan, N.1    Efron, N.2
  • 27
    • 0026468180 scopus 로고
    • A nuclear factor induced by hypoxia via de novo protein synthesis binds to the human erythropoietin gene enhancer at a site required for transcriptional activation
    • Semenza GL, Wang GL. A nuclear factor induced by hypoxia via de novo protein synthesis binds to the human erythropoietin gene enhancer at a site required for transcriptional activation. Mol Cell Biol 1992;12:5447-54.
    • (1992) Mol Cell Biol , vol.12 , pp. 5447-5454
    • Semenza, G.L.1    Wang, G.L.2
  • 28
    • 0029051439 scopus 로고
    • Hypoxia-inducible factor 1 is a basic-helix-loop-helix-PAS heterodimer regulated by cellular O2 tension
    • Wang GL, Jiang BH, Rue EA, Semenza GL. Hypoxia-inducible factor 1 is a basic-helix-loop-helix-PAS heterodimer regulated by cellular O2 tension. Proc Natl Acad Sci U S A 1995:92:5510-4.
    • (1995) Proc Natl Acad Sci U S A , vol.92 , pp. 5510-5514
    • Wang, G.L.1    Jiang, B.H.2    Rue, E.A.3    Semenza, G.L.4
  • 31
    • 0036469038 scopus 로고    scopus 로고
    • Asparagine hydroxylation of the HIF transactivation domain a hypoxic switch
    • Lando D, Peet DJ, Whelan DA, Gorman JJ, Whitelaw ML. Asparagine hydroxylation of the HIF transactivation domain a hypoxic switch. Science 2002;295:858-61.
    • (2002) Science , vol.295 , pp. 858-861
    • Lando, D.1    Peet, D.J.2    Whelan, D.A.3    Gorman, J.J.4    Whitelaw, M.L.5
  • 32
    • 0042761742 scopus 로고    scopus 로고
    • Evolution of the coordinate regulation of glycolytic enzyme genes by hypoxia
    • Webster KA. Evolution of the coordinate regulation of glycolytic enzyme genes by hypoxia. J Exp Biol 2003;206:2911-22.
    • (2003) J Exp Biol , vol.206 , pp. 2911-2922
    • Webster, K.A.1
  • 33
    • 21344448914 scopus 로고    scopus 로고
    • Some topographical changes associated with silicone hydrogen contact lenses may be due to inverted lenses
    • Bergenske P, Westburg M, Williams K, Caroline P, Smythe J. Some topographical changes associated with silicone hydrogen contact lenses may be due to inverted lenses. Optom Vis Sci 2004;81(suppl):78.
    • (2004) Optom Vis Sci , vol.81 , Issue.SUPPL. , pp. 78
    • Bergenske, P.1    Westburg, M.2    Williams, K.3    Caroline, P.4    Smythe, J.5
  • 35
    • 10644257886 scopus 로고    scopus 로고
    • Short-term physiologic response in neophyte subjects fitted with hydrogel and silicone hydrogel contact lenses
    • Maldonado-Codina C, Morgan PB, Schnider CM, Efron N. Short-term physiologic response in neophyte subjects fitted with hydrogel and silicone hydrogel contact lenses. Optom Vis Sci 2004;81: 911-21.
    • (2004) Optom Vis Sci , vol.81 , pp. 911-921
    • Maldonado-Codina, C.1    Morgan, P.B.2    Schnider, C.M.3    Efron, N.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.