-
2
-
-
84959778981
-
Quality assurance in radiotherapy: Physical and technical aspects
-
B.J. Mijnheer Quality assurance in radiotherapy physical and technical aspects Qual Assurance Health Care 4 1992 9 18
-
(1992)
Qual Assurance Health Care
, vol.4
, pp. 9-18
-
-
Mijnheer, B.J.1
-
3
-
-
0003639045
-
International Commission on Radiation Units and Measurements: Prescribing, Recording and Reporting Photon Beam Therapy
-
ICRU Bethesda, MD
-
International Commission on Radiation Units and Measurements Prescribing, Recording and Reporting Photon Beam Therapy Report 50 1993 ICRU Bethesda, MD
-
(1993)
Report 50
-
-
-
4
-
-
0027141138
-
Quality assessment of medical decision making in radiation oncology: Variability in target volume delineation for brain tumours
-
G. Leunens, J. Menten, C. Weltens Quality assessment of medical decision making in radiation oncology variability in target volume delineation for brain tumours Radiother Oncol 29 1993 169 175
-
(1993)
Radiother Oncol
, vol.29
, pp. 169-175
-
-
Leunens, G.1
Menten, J.2
Weltens, C.3
-
5
-
-
0031831777
-
Clinical variability of target volume description in conformal radiotherapy planning
-
J.P. Logue, C.L. Sharrock, R.A. Cowan Clinical variability of target volume description in conformal radiotherapy planning Int J Radiat Oncol Biol Phys 41 1998 929 931
-
(1998)
Int J Radiat Oncol Biol Phys
, vol.41
, pp. 929-931
-
-
Logue, J.P.1
Sharrock, C.L.2
Cowan, R.A.3
-
6
-
-
0028072733
-
Accuracy of volume measurements of computed tomography and magnetic resonance imaging phantoms by three-dimensional reconstruction and preliminary clinical application
-
D.G. Disler, D.S. Marr, D.I. Rosenthal Accuracy of volume measurements of computed tomography and magnetic resonance imaging phantoms by three-dimensional reconstruction and preliminary clinical application Invest Radiol 29 1994 739 745
-
(1994)
Invest Radiol
, vol.29
, pp. 739-745
-
-
Disler, D.G.1
Marr, D.S.2
Rosenthal, D.I.3
-
8
-
-
0031128389
-
Variation in prostate position quantitation and implications for three-dimensional conformal treatment planning
-
E. Melian, G.S. Mageras, Z. Fuks Variation in prostate position quantitation and implications for three-dimensional conformal treatment planning Int J Radiat Oncol Biol Phys 38 1997 73 81
-
(1997)
Int J Radiat Oncol Biol Phys
, vol.38
, pp. 73-81
-
-
Melian, E.1
Mageras, G.S.2
Fuks, Z.3
-
9
-
-
0031841437
-
Intraobserver and interobserver variability of MR imaging- and CT-derived prostate volumes after transperineal interstitial permanent prostate brachytherapy
-
D.F. Dubois, B.R. Prestidge, L.A. Hotchkiss Intraobserver and interobserver variability of MR imaging- and CT-derived prostate volumes after transperineal interstitial permanent prostate brachytherapy Radiology 207 1998 785 789
-
(1998)
Radiology
, vol.207
, pp. 785-789
-
-
Dubois, D.F.1
Prestidge, B.R.2
Hotchkiss, L.A.3
-
10
-
-
0031777574
-
Intra- and inter-observer variability in contouring prostate and seminal vesicles: Implications for conformal treatment planning
-
C. Fiorino, M. Reni, A. Bolognesi Intra- and inter-observer variability in contouring prostate and seminal vesicles implications for conformal treatment planning Radiother Oncol 47 1998 285 292
-
(1998)
Radiother Oncol
, vol.47
, pp. 285-292
-
-
Fiorino, C.1
Reni, M.2
Bolognesi, A.3
-
12
-
-
0026472070
-
A quantitative assessment of the addition of MRI to CT-based, 3-D treatment planning of brain tumors
-
R.K. ten Haken, A.F. Thornton Jr, H.M. Sandler A quantitative assessment of the addition of MRI to CT-based, 3-D treatment planning of brain tumors Radiother Oncol 25 1992 121 133
-
(1992)
Radiother Oncol
, vol.25
, pp. 121-133
-
-
Ten Haken, R.K.1
Thornton Jr., A.F.2
Sandler, H.M.3
-
13
-
-
0030940641
-
Consistency of three-dimensional planning target volumes across physicians and institutions
-
C.H. Ketting, M. Austin-Seymour, I. Kalet Consistency of three-dimensional planning target volumes across physicians and institutions Int J Radiat Oncol Biol Phys 37 1997 445 453
-
(1997)
Int J Radiat Oncol Biol Phys
, vol.37
, pp. 445-453
-
-
Ketting, C.H.1
Austin-Seymour, M.2
Kalet, I.3
-
14
-
-
0027441847
-
Comparison of treatment techniques for lung cancer
-
J.F. Valley, R.O. Mirimanoff Comparison of treatment techniques for lung cancer Radiother Oncol 28 1993 168 173
-
(1993)
Radiother Oncol
, vol.28
, pp. 168-173
-
-
Valley, J.F.1
Mirimanoff, R.O.2
-
15
-
-
17844379304
-
Variations in target delineation for head and neck IMRT: An international multi-institutional study
-
T.S. Hong, W.A. Tome, R.J. Chappell Variations in target delineation for head and neck IMRT an international multi-institutional study Int J Radiat Oncol Biol Phys 60 2004 S157 S158 (abstr)
-
(2004)
Int J Radiat Oncol Biol Phys
, vol.60
-
-
Hong, T.S.1
Tome, W.A.2
Chappell, R.J.3
-
16
-
-
0031055222
-
Magnetic resonance imaging (MRI): Considerations and applications in radiotherapy treatment planning
-
V.S. Khoo, D.P. Dearnaley, D.J. Finnigan Magnetic resonance imaging (MRI) considerations and applications in radiotherapy treatment planning Radiother Oncol 42 1997 1 15
-
(1997)
Radiother Oncol
, vol.42
, pp. 1-15
-
-
Khoo, V.S.1
Dearnaley, D.P.2
Finnigan, D.J.3
-
17
-
-
0031963840
-
Image registration: An essential part of radiation therapy treatment planning
-
J.G. Rosenman, E.P. Miller, G. Tracton Image registration an essential part of radiation therapy treatment planning Int J Radiat Oncol Biol Phys 40 1998 197 205
-
(1998)
Int J Radiat Oncol Biol Phys
, vol.40
, pp. 197-205
-
-
Rosenman, J.G.1
Miller, E.P.2
Tracton, G.3
-
18
-
-
0030811109
-
Initial clinical assessment of CT-MRI image fusion software in localization of the prostate for 3D conformal radiation therapy
-
K. Kagawa, W.R. Lee, T.E. Schultheiss Initial clinical assessment of CT-MRI image fusion software in localization of the prostate for 3D conformal radiation therapy Int J Radiat Oncol Biol Phys 38 1997 319 325
-
(1997)
Int J Radiat Oncol Biol Phys
, vol.38
, pp. 319-325
-
-
Kagawa, K.1
Lee, W.R.2
Schultheiss, T.E.3
-
19
-
-
0025885790
-
Integration of multimodality imaging data for radiotherapy treatment planning
-
M.L. Kessler, S. Pitluck, P. Petti Integration of multimodality imaging data for radiotherapy treatment planning Int J Radiat Oncol Biol Phys 21 1991 1653 1667
-
(1991)
Int J Radiat Oncol Biol Phys
, vol.21
, pp. 1653-1667
-
-
Kessler, M.L.1
Pitluck, S.2
Petti, P.3
-
20
-
-
0030657496
-
The potential impact of CT-MRI matching on tumor volume delineation in advanced head and neck cancer
-
C. Rasch, R. Keus, F.A. Pameijer The potential impact of CT-MRI matching on tumor volume delineation in advanced head and neck cancer Int J Radiat Oncol Biol Phys 39 1997 841 848
-
(1997)
Int J Radiat Oncol Biol Phys
, vol.39
, pp. 841-848
-
-
Rasch, C.1
Keus, R.2
Pameijer, F.A.3
-
21
-
-
0035400593
-
Interobserver variations in gross tumor volume delineation of brain tumors on computed tomography and impact of magnetic resonance imaging
-
C. Weltens, J. Menten, M. Feron Interobserver variations in gross tumor volume delineation of brain tumors on computed tomography and impact of magnetic resonance imaging Radiother Oncol 60 2001 49 59
-
(2001)
Radiother Oncol
, vol.60
, pp. 49-59
-
-
Weltens, C.1
Menten, J.2
Feron, M.3
-
22
-
-
0031667065
-
MRI-assisted specification/localization of target volumes. Aspects of quality control
-
N. Hosten, P. Wust, J. Beier MRI-assisted specification/localization of target volumes. Aspects of quality control Strahlenther Onkol 174 suppl 2 1998 13 18
-
(1998)
Strahlenther Onkol
, vol.174
, Issue.2 SUPPL.
, pp. 13-18
-
-
Hosten, N.1
Wust, P.2
Beier, J.3
-
23
-
-
0028213621
-
Image fusion for stereotactic radiotherapy and radiosurgery treatment planning
-
H.M. Kooy, M. van Herk, P.D. Barnes Image fusion for stereotactic radiotherapy and radiosurgery treatment planning Int J Radiat Oncol Biol Phys 28 1994 1229 1234
-
(1994)
Int J Radiat Oncol Biol Phys
, vol.28
, pp. 1229-1234
-
-
Kooy, H.M.1
Van Herk, M.2
Barnes, P.D.3
-
24
-
-
0026627887
-
Correction of spatial distortion in magnetic resonance angiography for radiosurgical treatment planning of cerebral arteriovenous malformations
-
L.R. Schad, H.H. Ehricke, B. Wowra Correction of spatial distortion in magnetic resonance angiography for radiosurgical treatment planning of cerebral arteriovenous malformations Magn Reson Imaging 10 1992 609 621
-
(1992)
Magn Reson Imaging
, vol.10
, pp. 609-621
-
-
Schad, L.R.1
Ehricke, H.H.2
Wowra, B.3
-
25
-
-
0026487072
-
The clinical utility of magnetic resonance imaging in 3-dimensional treatment planning of brain neoplasms
-
A.F. Thornton Jr, H.M. Sandler, R.K. ten Haken The clinical utility of magnetic resonance imaging in 3-dimensional treatment planning of brain neoplasms Int J Radiat Oncol Biol Phys 24 1992 767 775
-
(1992)
Int J Radiat Oncol Biol Phys
, vol.24
, pp. 767-775
-
-
Thornton Jr., A.F.1
Sandler, H.M.2
Ten Haken, R.K.3
-
26
-
-
0029996627
-
High-precision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imaging
-
A. Bel, P.H. Vos, P.T. Rodrigus High-precision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imaging Int J Radiat Oncol Biol Phys 35 1996 321 332
-
(1996)
Int J Radiat Oncol Biol Phys
, vol.35
, pp. 321-332
-
-
Bel, A.1
Vos, P.H.2
Rodrigus, P.T.3
-
27
-
-
0031870905
-
What margins should be added to the clinical target volume in radiotherapy treatment planning for lung cancer?
-
L. Ekberg, O. Holmberg, L. Wittgren What margins should be added to the clinical target volume in radiotherapy treatment planning for lung cancer? Radiother Oncol 48 1998 71 77
-
(1998)
Radiother Oncol
, vol.48
, pp. 71-77
-
-
Ekberg, L.1
Holmberg, O.2
Wittgren, L.3
-
28
-
-
0030932845
-
Measurement of patient positioning errors in three-dimensional conformal radiotherapy of the prostate
-
J. Hanley, M.A. Lumley, G.S. Mageras Measurement of patient positioning errors in three-dimensional conformal radiotherapy of the prostate Int J Radiat Oncol Biol Phys 37 1997 435 444
-
(1997)
Int J Radiat Oncol Biol Phys
, vol.37
, pp. 435-444
-
-
Hanley, J.1
Lumley, M.A.2
Mageras, G.S.3
-
29
-
-
0029062520
-
Incidence of and factors related to late complications in conformal and conventional radiation treatment of cancer of the prostate
-
T.E. Schultheiss, G.E. Hanks, M.A. Hunt Incidence of and factors related to late complications in conformal and conventional radiation treatment of cancer of the prostate Int J Radiat Oncol Biol Phys 32 1995 643 649
-
(1995)
Int J Radiat Oncol Biol Phys
, vol.32
, pp. 643-649
-
-
Schultheiss, T.E.1
Hanks, G.E.2
Hunt, M.A.3
-
30
-
-
0029810297
-
Target margins for random geometrical treatment uncertainties in conformal radiotherapy
-
A. Bel, M. van Herk, J.V. Lebesque Target margins for random geometrical treatment uncertainties in conformal radiotherapy Med Phys 23 1996 1537 1545
-
(1996)
Med Phys
, vol.23
, pp. 1537-1545
-
-
Bel, A.1
Van Herk, M.2
Lebesque, J.V.3
-
31
-
-
0031974195
-
Imaging protocol for radical dose-escalated radiotherapy treatment of prostate cancer
-
C.D. Mubata, A.M. Bidmead, L.M. Ellingham Imaging protocol for radical dose-escalated radiotherapy treatment of prostate cancer Int J Radiat Oncol Biol Phys 40 1998 221 231
-
(1998)
Int J Radiat Oncol Biol Phys
, vol.40
, pp. 221-231
-
-
Mubata, C.D.1
Bidmead, A.M.2
Ellingham, L.M.3
-
32
-
-
0028981081
-
Comparison of plastic and Orfit masks for patient head fixation during radiotherapy: Precision and costs
-
C. Weltens, K. Kesteloot, G. Vandevelde Comparison of plastic and Orfit masks for patient head fixation during radiotherapy precision and costs Int J Radiat Oncol Biol Phys 33 1995 499 507
-
(1995)
Int J Radiat Oncol Biol Phys
, vol.33
, pp. 499-507
-
-
Weltens, C.1
Kesteloot, K.2
Vandevelde, G.3
-
34
-
-
0031817624
-
Target volume definition for three-dimensional conformal radiation therapy of lung cancer
-
J.G. Armstrong Target volume definition for three-dimensional conformal radiation therapy of lung cancer Br J Radiol 71 1998 587 594
-
(1998)
Br J Radiol
, vol.71
, pp. 587-594
-
-
Armstrong, J.G.1
-
35
-
-
0028797095
-
Measurement of prostate movement over the course of routine radiotherapy using implanted markers
-
J.M. Balter, H.M. Sandler, K. Lam Measurement of prostate movement over the course of routine radiotherapy using implanted markers Int J Radiat Oncol Biol Phys 31 1995 113 118
-
(1995)
Int J Radiat Oncol Biol Phys
, vol.31
, pp. 113-118
-
-
Balter, J.M.1
Sandler, H.M.2
Lam, K.3
-
36
-
-
0030061461
-
Analysis of prostate and seminal vesicle motion: Implications for treatment planning
-
C.J. Beard, P. Kijewski, M. Bussiere Analysis of prostate and seminal vesicle motion implications for treatment planning Int J Radiat Oncol Biol Phys 34 1996 451 458
-
(1996)
Int J Radiat Oncol Biol Phys
, vol.34
, pp. 451-458
-
-
Beard, C.J.1
Kijewski, P.2
Bussiere, M.3
-
37
-
-
0032440911
-
Target position variability throughout prostate radiotherapy
-
L.A. Dawson, K. Mah, E. Franssen Target position variability throughout prostate radiotherapy Int J Radiat Oncol Biol Phys 42 1998 1155 1161
-
(1998)
Int J Radiat Oncol Biol Phys
, vol.42
, pp. 1155-1161
-
-
Dawson, L.A.1
Mah, K.2
Franssen, E.3
-
38
-
-
0028784185
-
Evaluation of changes in the size and location of the prostate, seminal vesicles, bladder, and rectum during a course of external beam radiation therapy
-
J.C. Roeske, J.D. Forman, C.F. Mesina Evaluation of changes in the size and location of the prostate, seminal vesicles, bladder, and rectum during a course of external beam radiation therapy Int J Radiat Oncol Biol Phys 33 1995 1321 1329
-
(1995)
Int J Radiat Oncol Biol Phys
, vol.33
, pp. 1321-1329
-
-
Roeske, J.C.1
Forman, J.D.2
Mesina, C.F.3
-
39
-
-
0031694576
-
A critical evaluation of the planning target volume for 3-D conformal radiotherapy of prostate cancer
-
A. Tinger, J.M. Michalski, A. Cheng A critical evaluation of the planning target volume for 3-D conformal radiotherapy of prostate cancer Int J Radiat Oncol Biol Phys 42 1998 213 221
-
(1998)
Int J Radiat Oncol Biol Phys
, vol.42
, pp. 213-221
-
-
Tinger, A.1
Michalski, J.M.2
Cheng, A.3
-
41
-
-
0030586042
-
Prostate volumes defined by magnetic resonance imaging and computerized tomographic scans for three-dimensional conformal radiotherapy
-
M. Roach III, P. Faillace-Akazawa, C. Malfatti Prostate volumes defined by magnetic resonance imaging and computerized tomographic scans for three-dimensional conformal radiotherapy Int J Radiat Oncol Biol Phys 35 1996 1011 1018
-
(1996)
Int J Radiat Oncol Biol Phys
, vol.35
, pp. 1011-1018
-
-
Roach III, M.1
Faillace-Akazawa, P.2
Malfatti, C.3
-
42
-
-
0032527644
-
Daily CT localization for correcting portal errors in the treatment of prostate cancer
-
J. Lattanzi, S. McNeely, A. Hanlon Daily CT localization for correcting portal errors in the treatment of prostate cancer Int J Radiat Oncol Biol Phys 41 1998 1079 1086
-
(1998)
Int J Radiat Oncol Biol Phys
, vol.41
, pp. 1079-1086
-
-
Lattanzi, J.1
McNeely, S.2
Hanlon, A.3
-
43
-
-
0028123299
-
Larynx motion associated with swallowing during radiation therapy
-
S. Hamlet, G. Ezzell, A. Aref Larynx motion associated with swallowing during radiation therapy Int J Radiat Oncol Biol Phys 28 1994 467 470
-
(1994)
Int J Radiat Oncol Biol Phys
, vol.28
, pp. 467-470
-
-
Hamlet, S.1
Ezzell, G.2
Aref, A.3
-
44
-
-
0030995281
-
Treatment portals for elective radiotherapy of the neck: An inventory in the Netherlands
-
P. Nowak, E. van Dieren, d.K. van Sornsen Treatment portals for elective radiotherapy of the neck an inventory in The Netherlands Radiother Oncol 43 1997 81 86
-
(1997)
Radiother Oncol
, vol.43
, pp. 81-86
-
-
Nowak, P.1
Van Dieren, E.2
Van Sornsen, D.K.3
-
45
-
-
3242688903
-
CT-based delineation of lymph node levels and related CTVs in the node-negative neck: DAHANCA, EORTC, GORTEC, NCIC, RTOG consensus guidelines
-
V. Gregoire, P. Levendag, K.K. Ang CT-based delineation of lymph node levels and related CTVs in the node-negative neck DAHANCA, EORTC, GORTEC, NCIC, RTOG consensus guidelines Radiother Oncol 69 2003 227 236
-
(2003)
Radiother Oncol
, vol.69
, pp. 227-236
-
-
Gregoire, V.1
Levendag, P.2
Ang, K.K.3
-
46
-
-
10744231274
-
Rotterdam and Brussels CT-based neck nodal delineation compared with the surgical levels as defined by the American Academy of Otolaryngology-Head and Neck Surgery
-
P. Levendag, M. Braaksma, E. Coche Rotterdam and Brussels CT-based neck nodal delineation compared with the surgical levels as defined by the American Academy of Otolaryngology-Head and Neck Surgery Int J Radiat Oncol Biol Phys 58 2004 113 123
-
(2004)
Int J Radiat Oncol Biol Phys
, vol.58
, pp. 113-123
-
-
Levendag, P.1
Braaksma, M.2
Coche, E.3
-
47
-
-
3242738633
-
A population-based atlas and clinical target volume for the head-and-neck lymph nodes
-
I. Poon, N. Fischbein, N. Lee A population-based atlas and clinical target volume for the head-and-neck lymph nodes Int J Radiat Oncol Biol Phys 59 2004 1301 1311
-
(2004)
Int J Radiat Oncol Biol Phys
, vol.59
, pp. 1301-1311
-
-
Poon, I.1
Fischbein, N.2
Lee, N.3
-
48
-
-
1442276257
-
Impact of magnetic resonance imaging versus CT on nasopharyngeal carcinoma: Primary tumor target delineation for radiotherapy
-
N.N. Chung, L.L. Ting, W.C. Hsu Impact of magnetic resonance imaging versus CT on nasopharyngeal carcinoma primary tumor target delineation for radiotherapy Head Neck 26 2004 241 246
-
(2004)
Head Neck
, vol.26
, pp. 241-246
-
-
Chung, N.N.1
Ting, L.L.2
Hsu, W.C.3
-
49
-
-
0023918469
-
MRI assisted treatment planning for radiation therapy of the head and neck
-
L.M. Toonkel, K. Soila, D. Gilbert MRI assisted treatment planning for radiation therapy of the head and neck Magn Reson Imaging 6 1988 315 319
-
(1988)
Magn Reson Imaging
, vol.6
, pp. 315-319
-
-
Toonkel, L.M.1
Soila, K.2
Gilbert, D.3
-
50
-
-
0024418694
-
The use of magnetic resonance imaging and spectroscopy in the assessment of patients with head and neck and other superficial human malignancies
-
W.G. McKenna, R.E. Lenkinski, R.A. Hendrix The use of magnetic resonance imaging and spectroscopy in the assessment of patients with head and neck and other superficial human malignancies Cancer 64 1989 2069 2075
-
(1989)
Cancer
, vol.64
, pp. 2069-2075
-
-
McKenna, W.G.1
Lenkinski, R.E.2
Hendrix, R.A.3
-
51
-
-
20644457975
-
Observer variation in delineation of nasopharyngeal carcinoma for radiotherapy: A 3-D analysis
-
R.J. Steenbakkers, J. Duppen, I. Fitton Observer variation in delineation of nasopharyngeal carcinoma for radiotherapy a 3-D analysis Int J Radiat Oncol Biol. Phys 60 2004 s160 s161 (abstr)
-
(2004)
Int J Radiat Oncol Biol. Phys
, vol.60
-
-
Steenbakkers, R.J.1
Duppen, J.2
Fitton, I.3
-
52
-
-
0042383175
-
Influence of MRI on target volume delineation and IMRT planning in nasopharyngeal carcinoma
-
B. Emami, A. Sethi, G.J. Petruzzelli Influence of MRI on target volume delineation and IMRT planning in nasopharyngeal carcinoma Int J Radiat Oncol Biol Phys 57 2003 481 488
-
(2003)
Int J Radiat Oncol Biol Phys
, vol.57
, pp. 481-488
-
-
Emami, B.1
Sethi, A.2
Petruzzelli, G.J.3
-
53
-
-
0030138566
-
Accuracy of prostate volume measurements in vitro using three-dimensional ultrasound
-
T.L. Elliot, D.B. Downey, S.A. Tong Accuracy of prostate volume measurements in vitro using three-dimensional ultrasound Acad Radiol 3 1996 401 406
-
(1996)
Acad Radiol
, vol.3
, pp. 401-406
-
-
Elliot, T.L.1
Downey, D.B.2
Tong, S.A.3
-
54
-
-
0030839699
-
Prediction of pathological tumor volume in clinically localized prostate cancer: Value of endorectal coil magnetic resonance imaging
-
R. Lencioni, I. Menchi, A. Paolicchi Prediction of pathological tumor volume in clinically localized prostate cancer value of endorectal coil magnetic resonance imaging MAGMA 5 1997 117 121
-
(1997)
MAGMA
, vol.5
, pp. 117-121
-
-
Lencioni, R.1
Menchi, I.2
Paolicchi, A.3
-
55
-
-
0029614360
-
Validation of a technique of computer-aided tumor volume determination
-
J.M. Wheatley, N.S. Rosenfield, G. Heller Validation of a technique of computer-aided tumor volume determination J Surg Res 59 1995 621 626
-
(1995)
J Surg Res
, vol.59
, pp. 621-626
-
-
Wheatley, J.M.1
Rosenfield, N.S.2
Heller, G.3
-
56
-
-
0032901490
-
Measurement of liver volume using spiral CT and the curved line and cubic spline algorithms: Reproducibility and interobserver variation
-
K. Sandrasegaran, P.W. Kwo, D. DiGirolamo Measurement of liver volume using spiral CT and the curved line and cubic spline algorithms reproducibility and interobserver variation Abdom Imaging 24 1999 61 65
-
(1999)
Abdom Imaging
, vol.24
, pp. 61-65
-
-
Sandrasegaran, K.1
Kwo, P.W.2
Digirolamo, D.3
-
57
-
-
0031757606
-
Angiosarcoma of the head and neck managed by a combination of multiple biopsies to determine tumor margin and radiation therapy
-
R. Bullen, P.O. Larson, A.E. Landeck Angiosarcoma of the head and neck managed by a combination of multiple biopsies to determine tumor margin and radiation therapy Report of three cases and review of the literature. Dermatol Surg 24 1998 1105 1110
-
(1998)
Report of Three Cases and Review of the Literature. Dermatol Surg
, vol.24
, pp. 1105-1110
-
-
Bullen, R.1
Larson, P.O.2
Landeck, A.E.3
-
58
-
-
0026534607
-
Laser-induced fluorescence: Experimental intraoperative delineation of tumor resection margins
-
W.S. Poon, K.T. Schomacker, T.F. Deutsch Laser-induced fluorescence experimental intraoperative delineation of tumor resection margins J Neurosurg 76 1992 679 686
-
(1992)
J Neurosurg
, vol.76
, pp. 679-686
-
-
Poon, W.S.1
Schomacker, K.T.2
Deutsch, T.F.3
-
59
-
-
2542431960
-
Role of 11-C-methionine positron emission tomography for the delineation of the tumor volume in pharyngo-laryngeal squamous cell carcinoma: Comparison with FDG-PET and CT
-
X. Geets, J.F. Daisne, V. Gregoire Role of 11-C-methionine positron emission tomography for the delineation of the tumor volume in pharyngo-laryngeal squamous cell carcinoma comparison with FDG-PET and CT Radiother Oncol 71 2004 267 273
-
(2004)
Radiother Oncol
, vol.71
, pp. 267-273
-
-
Geets, X.1
Daisne, J.F.2
Gregoire, V.3
-
60
-
-
0031838391
-
Automatic three-dimensional matching of CT-SPECT and CT-CT to localize lung damage after radiotherapy
-
S.L. Kwa, J.C. Theuws, M. van Herk Automatic three-dimensional matching of CT-SPECT and CT-CT to localize lung damage after radiotherapy J Nucl Med 39 1998 1074 1080
-
(1998)
J Nucl Med
, vol.39
, pp. 1074-1080
-
-
Kwa, S.L.1
Theuws, J.C.2
Van Herk, M.3
-
61
-
-
1042287076
-
Positron emission tomography in the management of non-small cell lung cancer
-
J.F. Vansteenkiste, S.G. Stroobants Positron emission tomography in the management of non-small cell lung cancer Hematol Oncol Clin North Am 18 2004 269 288
-
(2004)
Hematol Oncol Clin North Am
, vol.18
, pp. 269-288
-
-
Vansteenkiste, J.F.1
Stroobants, S.G.2
-
62
-
-
0031772968
-
Potential use of FDG-PET scan after induction chemotherapy in surgically staged IIIa-N2 non-small-cell lung cancer: A prospective pilot study
-
The Leuven Lung Cancer Group P.R.
-
J.F. Vansteenkiste, S.G. Stroobants, P.R. De Leyn The Leuven Lung Cancer Group Potential use of FDG-PET scan after induction chemotherapy in surgically staged IIIa-N2 non-small-cell lung cancer a prospective pilot study Ann Oncol 9 1998 1193 1198
-
(1998)
Ann Oncol
, vol.9
, pp. 1193-1198
-
-
Vansteenkiste, J.F.1
Stroobants, S.G.2
De Leyn3
-
63
-
-
0035889268
-
Defined non-small-cell lung tumors on CT: The impact of 18FDG-hybrid PET fusion
-
C.B. Caldwell, K. Mah, Y.C. Ung defined non-small-cell lung tumors on CT the impact of 18FDG-hybrid PET fusion Int J Radiat Oncol Biol Phys 51 2001 923 931
-
(2001)
Int J Radiat Oncol Biol Phys
, vol.51
, pp. 923-931
-
-
Caldwell, C.B.1
Mah, K.2
Ung, Y.C.3
-
64
-
-
4444289151
-
Impact of FDG-PET on radiation therapy volume delineation in non-small-cell lung cancer
-
J. Bradley, W.L. Thorstad, S. Mutic Impact of FDG-PET on radiation therapy volume delineation in non-small-cell lung cancer Int J Radiat Oncol Biol Phys 59 2004 78 86
-
(2004)
Int J Radiat Oncol Biol Phys
, vol.59
, pp. 78-86
-
-
Bradley, J.1
Thorstad, W.L.2
Mutic, S.3
-
65
-
-
20644460859
-
A 3D analysis and reduction of observer variation in delineation of lung cancer for radiotherapy
-
R.J. Steenbakkers, J. Duppen, I. Fitton A 3D analysis and reduction of observer variation in delineation of lung cancer for radiotherapy Int J Radiat Oncol Biol Phys 60 2004 s531 s532 (abstr)
-
(2004)
Int J Radiat Oncol Biol Phys
, vol.60
-
-
Steenbakkers, R.J.1
Duppen, J.2
Fitton, I.3
-
66
-
-
0036643959
-
Measurement of lung tumor volumes using three-dimensional computer planning software
-
P. Bowden, R. Fisher, M.M. Mac Measurement of lung tumor volumes using three-dimensional computer planning software Int J Radiat Oncol Biol Phys 53 2002 566 573
-
(2002)
Int J Radiat Oncol Biol Phys
, vol.53
, pp. 566-573
-
-
Bowden, P.1
Fisher, R.2
Mac, M.M.3
-
67
-
-
0028832892
-
Localization of the prostatic apex for radiation treatment planning
-
O. Algan, G.E. Hanks, A.H. Shaer Localization of the prostatic apex for radiation treatment planning Int J Radiat Oncol Biol Phys 33 1995 925 930
-
(1995)
Int J Radiat Oncol Biol Phys
, vol.33
, pp. 925-930
-
-
Algan, O.1
Hanks, G.E.2
Shaer, A.H.3
-
68
-
-
0028102229
-
Prostate cancer: Comparison of retrograde urethrography and computed tomography in radiotherapy planning
-
J.A. Cox, R.J. Zagoria, M. Raben Prostate cancer comparison of retrograde urethrography and computed tomography in radiotherapy planning Int J Radiat Oncol Biol Phys 29 1994 1119 1123
-
(1994)
Int J Radiat Oncol Biol Phys
, vol.29
, pp. 1119-1123
-
-
Cox, J.A.1
Zagoria, R.J.2
Raben, M.3
-
69
-
-
0030790675
-
Enhancement of prostate tumor volume definition with intravesical contrast: A three-dimensional dosimetric evaluation
-
R. Sharma, M. Duclos, P.J. Chuba Enhancement of prostate tumor volume definition with intravesical contrast a three-dimensional dosimetric evaluation Int J Radiat Oncol Biol Phys 38 1997 575 582
-
(1997)
Int J Radiat Oncol Biol Phys
, vol.38
, pp. 575-582
-
-
Sharma, R.1
Duclos, M.2
Chuba, P.J.3
-
70
-
-
0031690493
-
Differences in gross target volumes on contrast vs. noncontrast CT scans utilized for conformal radiation therapy treatment planning for prostate carcinoma
-
S.M. Zhou, G.C. Bentel, C.G. Lee Differences in gross target volumes on contrast vs. noncontrast CT scans utilized for conformal radiation therapy treatment planning for prostate carcinoma Int J Radiat Oncol Biol Phys 42 1998 73 78
-
(1998)
Int J Radiat Oncol Biol Phys
, vol.42
, pp. 73-78
-
-
Zhou, S.M.1
Bentel, G.C.2
Lee, C.G.3
-
71
-
-
0030831979
-
Prostate volumes and organ movement defined by serial computerized tomographic scans during three-dimensional conformal radiotherapy
-
M. Roach III, P. Faillace-Akazawa, C. Malfatti Prostate volumes and organ movement defined by serial computerized tomographic scans during three-dimensional conformal radiotherapy Radiat Oncol Investig 5 1997 187 194
-
(1997)
Radiat Oncol Investig
, vol.5
, pp. 187-194
-
-
Roach III, M.1
Faillace-Akazawa, P.2
Malfatti, C.3
-
72
-
-
0030480944
-
Short communication: CT-MRI image fusion for 3D conformal prostate radiotherapy: Use in patients with altered pelvic anatomy
-
H.Y. Lau, K. Kagawa, W.R. Lee Short communication: CT-MRI image fusion for 3D conformal prostate radiotherapy: use in patients with altered pelvic anatomy Br J Radiol 69 1996 1165 1170
-
(1996)
Br J Radiol
, vol.69
, pp. 1165-1170
-
-
Lau, H.Y.1
Kagawa, K.2
Lee, W.R.3
-
73
-
-
0032133599
-
Clinical role of magnetic resonance imaging (MRI) of prostatic cancer
-
Y. Nasu, T. Murakami Clinical role of magnetic resonance imaging (MRI) of prostatic cancer Nippon Rinsho 56 1998 2042 2045
-
(1998)
Nippon Rinsho
, vol.56
, pp. 2042-2045
-
-
Nasu, Y.1
Murakami, T.2
-
74
-
-
0037297702
-
Radiotherapy treatment planning of prostate cancer using magnetic resonance imaging alone
-
Y.K. Lee, M. Bollet, G. Charles-Edwards Radiotherapy treatment planning of prostate cancer using magnetic resonance imaging alone Radiother Oncol 66 2003 203 216
-
(2003)
Radiother Oncol
, vol.66
, pp. 203-216
-
-
Lee, Y.K.1
Bollet, M.2
Charles-Edwards, G.3
-
76
-
-
0031779558
-
Interphysician variability in defining the planning target volume in the irradiation of prostate and seminal vesicles
-
L.F. Cazzaniga, M.A. Marinoni, A. Bossi Interphysician variability in defining the planning target volume in the irradiation of prostate and seminal vesicles Radiother Oncol 47 1998 293 296
-
(1998)
Radiother Oncol
, vol.47
, pp. 293-296
-
-
Cazzaniga, L.F.1
Marinoni, M.A.2
Bossi, A.3
-
77
-
-
0031746513
-
Magnetic resonance imaging (MRI) for localization of the prostatic apex: Comparison to computed tomography (CT) and urethrography
-
M. Milosevic, S. Voruganti, R. Blend Magnetic resonance imaging (MRI) for localization of the prostatic apex comparison to computed tomography (CT) and urethrography Radiother Oncol 47 1998 277 284
-
(1998)
Radiother Oncol
, vol.47
, pp. 277-284
-
-
Milosevic, M.1
Voruganti, S.2
Blend, R.3
-
78
-
-
0036471751
-
Magnetic resonance spectroscopic imaging-guided brachytherapy for localized prostate cancer
-
S.J. DiBiase, K. Hosseinzadeh, R.P. Gullapalli Magnetic resonance spectroscopic imaging-guided brachytherapy for localized prostate cancer Int J Radiat Oncol Biol Phys 52 2002 429 438
-
(2002)
Int J Radiat Oncol Biol Phys
, vol.52
, pp. 429-438
-
-
Dibiase, S.J.1
Hosseinzadeh, K.2
Gullapalli, R.P.3
-
79
-
-
0032054090
-
Estimation of the incidence of late bladder and rectum complications after high-dose (70-78 GY) conformal radiotherapy for prostate cancer, using dose-volume histograms
-
L.J. Boersma, B.M. van den, A.M. Bruce Estimation of the incidence of late bladder and rectum complications after high-dose (70-78 GY) conformal radiotherapy for prostate cancer, using dose-volume histograms Int J Radiat Oncol Biol Phys 41 1998 83 92
-
(1998)
Int J Radiat Oncol Biol Phys
, vol.41
, pp. 83-92
-
-
Boersma, L.J.1
Van Den, B.M.2
Bruce, A.M.3
-
80
-
-
0032724671
-
Comparison of prostate cancer treatment in two institutions: A quality control study
-
C. Rasch, P. Remeijer, P.C. Koper Comparison of prostate cancer treatment in two institutions a quality control study Int J Radiat Oncol Biol Phys 45 1999 1055 1062
-
(1999)
Int J Radiat Oncol Biol Phys
, vol.45
, pp. 1055-1062
-
-
Rasch, C.1
Remeijer, P.2
Koper, P.C.3
-
81
-
-
0345257841
-
Reduction of dose delivered to the rectum and bulb of the penis using MRI delineation for radiotherapy of the prostate
-
R.J. Steenbakkers, K.E. Deurloo, P.J. Nowak Reduction of dose delivered to the rectum and bulb of the penis using MRI delineation for radiotherapy of the prostate Int J Radiat Oncol Biol Phys 57 2003 1269 1279
-
(2003)
Int J Radiat Oncol Biol Phys
, vol.57
, pp. 1269-1279
-
-
Steenbakkers, R.J.1
Deurloo, K.E.2
Nowak, P.J.3
-
82
-
-
0023502553
-
Integration of magnetic resonance imaging into radiation therapy treatment planning: I. Technical considerations
-
B.A. Fraass, D.L. McShan, R.F. Diaz Integration of magnetic resonance imaging into radiation therapy treatment planning: I. Technical considerations Int J Radiat Oncol Biol Phys 13 1987 1897 1908
-
(1987)
Int J Radiat Oncol Biol Phys
, vol.13
, pp. 1897-1908
-
-
Fraass, B.A.1
McShan, D.L.2
Diaz, R.F.3
-
83
-
-
0027933729
-
Automatic three-dimensional correlation of CT-CT, CT-MRI, and CT-SPECT using chamfer matching
-
M. van Herk, H.M. Kooy Automatic three-dimensional correlation of CT-CT, CT-MRI, and CT-SPECT using chamfer matching Med Phys 21 1994 1163 1178
-
(1994)
Med Phys
, vol.21
, pp. 1163-1178
-
-
Van Herk, M.1
Kooy, H.M.2
-
84
-
-
0031663432
-
Image processing in stereotactic planning: Volume visualization and image registration
-
C.A. Pelizzari Image processing in stereotactic planning volume visualization and image registration Med Dosim 23 1998 137 145
-
(1998)
Med Dosim
, vol.23
, pp. 137-145
-
-
Pelizzari, C.A.1
-
85
-
-
0031947864
-
Registration of MR and SPECT without using external fiducial markers
-
J.C. de Munck, F.C. Verster, E.A. Dubois Registration of MR and SPECT without using external fiducial markers Phys Med Biol 43 1998 1255 1269
-
(1998)
Phys Med Biol
, vol.43
, pp. 1255-1269
-
-
De Munck, J.C.1
Verster, F.C.2
Dubois, E.A.3
-
86
-
-
0028686711
-
Brain segmentation and white matter lesion detection in MR images
-
A.P. Zijdenbos, B.M. Dawant Brain segmentation and white matter lesion detection in MR images Crit Rev Biomed Eng 22 1994 401 465
-
(1994)
Crit Rev Biomed Eng
, vol.22
, pp. 401-465
-
-
Zijdenbos, A.P.1
Dawant, B.M.2
-
87
-
-
0033033104
-
Usability of semiautomatic segmentation algorithms for tumor volume determination
-
A. Mahr, S. Levegrun, M.L. Bahner Usability of semiautomatic segmentation algorithms for tumor volume determination Invest Radiol 34 1999 143 150
-
(1999)
Invest Radiol
, vol.34
, pp. 143-150
-
-
Mahr, A.1
Levegrun, S.2
Bahner, M.L.3
-
89
-
-
20644452734
-
Evaluation of a novel method for semi-automatic delineation
-
E. Bellon, M. Feron, L. van Hoe Evaluation of a novel method for semi-automatic delineation Proc Europacs 96 1996 107 111
-
(1996)
Proc Europacs
, vol.96
, pp. 107-111
-
-
Bellon, E.1
Feron, M.2
Van Hoe, L.3
-
90
-
-
0033001375
-
Volumetric visualization of head and neck CT data for treatment planning
-
J.S. Lee, A.B. Jani, C.A. Pelizzari Volumetric visualization of head and neck CT data for treatment planning Int J Radiat Oncol Biol Phys 44 1999 693 703
-
(1999)
Int J Radiat Oncol Biol Phys
, vol.44
, pp. 693-703
-
-
Lee, J.S.1
Jani, A.B.2
Pelizzari, C.A.3
-
91
-
-
0029909342
-
Tumour volume determination from MR images by morphological segmentation
-
P. Gibbs, D.L. Buckley, S.J. Blackband Tumour volume determination from MR images by morphological segmentation Phys Med Biol 41 1996 2437 2446
-
(1996)
Phys Med Biol
, vol.41
, pp. 2437-2446
-
-
Gibbs, P.1
Buckley, D.L.2
Blackband, S.J.3
-
93
-
-
0032034227
-
Automatic tumor segmentation using knowledge-based techniques
-
M.C. Clark, L.O. Hall, D.B. Goldgof Automatic tumor segmentation using knowledge-based techniques IEEE Trans Med Imaging 17 1998 187 201
-
(1998)
IEEE Trans Med Imaging
, vol.17
, pp. 187-201
-
-
Clark, M.C.1
Hall, L.O.2
Goldgof, D.B.3
-
94
-
-
0029046692
-
Comparison of supervised MRI segmentation methods for tumor volume determination during therapy
-
M. Vaidyanathan, L.P. Clarke, R.P. Velthuizen Comparison of supervised MRI segmentation methods for tumor volume determination during therapy Magn Reson Imaging 13 1995 719 728
-
(1995)
Magn Reson Imaging
, vol.13
, pp. 719-728
-
-
Vaidyanathan, M.1
Clarke, L.P.2
Velthuizen, R.P.3
-
95
-
-
0027607872
-
Image segmentation: Methods and applications in diagnostic radiology and nuclear medicine
-
P. Suetens, E. Bellon, D. Vandermeulen Image segmentation methods and applications in diagnostic radiology and nuclear medicine Eur J Radiol 17 1993 14 21
-
(1993)
Eur J Radiol
, vol.17
, pp. 14-21
-
-
Suetens, P.1
Bellon, E.2
Vandermeulen, D.3
-
96
-
-
20644433811
-
Semi-automatic delineation tool of CT-MRI registered images for nasopharyngeal carcinoma
-
I. Fitton, S. Cornelissen, J. Duppen Semi-automatic delineation tool of CT-MRI registered images for nasopharyngeal carcinoma Int J Radiat Oncol Biol Phys 73 2004 S178 398, (abstr)
-
(2004)
Int J Radiat Oncol Biol Phys
, vol.73
, pp. 178
-
-
Fitton, I.1
Cornelissen, S.2
Duppen, J.3
-
98
-
-
2642683174
-
An adaptive control algorithm for optimization of intensity modulated radiotherapy considering uncertainties in beam profiles, patient set-up and internal organ motion
-
J. Lof, B.K. Lind, A. Brahme An adaptive control algorithm for optimization of intensity modulated radiotherapy considering uncertainties in beam profiles, patient set-up and internal organ motion Phys Med Biol 43 1998 1605 1628
-
(1998)
Phys Med Biol
, vol.43
, pp. 1605-1628
-
-
Lof, J.1
Lind, B.K.2
Brahme, A.3
-
99
-
-
0033556588
-
Computerized design of target margins for treatment uncertainties in conformal radiotherapy
-
G.S. Mageras, Z. Fuks, S.A. Leibel Computerized design of target margins for treatment uncertainties in conformal radiotherapy Int J Radiat Oncol Biol Phys 43 1999 437 445
-
(1999)
Int J Radiat Oncol Biol Phys
, vol.43
, pp. 437-445
-
-
Mageras, G.S.1
Fuks, Z.2
Leibel, S.A.3
-
100
-
-
0033041247
-
Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability
-
J.C. Stroom, H.C. de Boer, H. Huizenga Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability Int J Radiat Oncol Biol Phys 43 1999 905 919
-
(1999)
Int J Radiat Oncol Biol Phys
, vol.43
, pp. 905-919
-
-
Stroom, J.C.1
De Boer, H.C.2
Huizenga, H.3
-
101
-
-
0036661305
-
Geometrical uncertainties, radiotherapy planning margins, and the ICRU-62 report
-
J.C. Stroom, B.J. Heijmen Geometrical uncertainties, radiotherapy planning margins, and the ICRU-62 report Radiother Oncol 64 2002 75 83
-
(2002)
Radiother Oncol
, vol.64
, pp. 75-83
-
-
Stroom, J.C.1
Heijmen, B.J.2
-
102
-
-
0842306308
-
Errors and margins in radiotherapy
-
M. van Herk Errors and margins in radiotherapy Semin Radiat Oncol 14 2004 52 64
-
(2004)
Semin Radiat Oncol
, vol.14
, pp. 52-64
-
-
Van Herk, M.1
-
103
-
-
10044286277
-
Recurrences near base of skull after IMRT for head-and-neck cancer: Implications for target delineation in high neck and for parotid gland sparing
-
A. Eisbruch, L.H. Marsh, L.A. Dawson Recurrences near base of skull after IMRT for head-and-neck cancer implications for target delineation in high neck and for parotid gland sparing Int J Radiat Oncol Biol Phys May 59 2004 28 42
-
(2004)
Int J Radiat Oncol Biol Phys May
, vol.59
, pp. 28-42
-
-
Eisbruch, A.1
Marsh, L.H.2
Dawson, L.A.3
-
104
-
-
0344440831
-
Evaluation of a multimodality image (CT, MRI and PET) coregistration procedure on phantom and head and neck cancer patients: Accuracy, reproducibility and consistency
-
J.F. Daisne, M. Sibomana, A. Bol Evaluation of a multimodality image (CT, MRI and PET) coregistration procedure on phantom and head and neck cancer patients accuracy, reproducibility and consistency Radiother Oncol 69 2003 237 245
-
(2003)
Radiother Oncol
, vol.69
, pp. 237-245
-
-
Daisne, J.F.1
Sibomana, M.2
Bol, A.3
-
105
-
-
0034653346
-
Patterns of local-regional recurrence following parotid-sparing conformal and segmental intensity-modulated radiotherapy for head and neck cancer
-
L.A. Dawson, Y. Anzai, L. Marsh Patterns of local-regional recurrence following parotid-sparing conformal and segmental intensity-modulated radiotherapy for head and neck cancer Int J Radiat Oncol Biol Phys Mar 46 2000 1117 1126
-
(2000)
Int J Radiat Oncol Biol Phys Mar
, vol.46
, pp. 1117-1126
-
-
Dawson, L.A.1
Anzai, Y.2
Marsh, L.3
-
106
-
-
0030973792
-
Automatic calculation of three-dimensional margins around treatment volumes in radiotherapy planning
-
J.C. Stroom, P.R. Storchi Automatic calculation of three-dimensional margins around treatment volumes in radiotherapy planning Phys Med Biol 42 1997 745 755
-
(1997)
Phys Med Biol
, vol.42
, pp. 745-755
-
-
Stroom, J.C.1
Storchi, P.R.2
|