메뉴 건너뛰기




Volumn 43, Issue 6, 1998, Pages 1605-1628

An adaptive control algorithm for optimization of intensity modulated radiotherapy considering uncertainties in beam profiles, patient set-up and internal organ motion

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHM; ARTICLE; BEAM THERAPY; COMPUTER SIMULATION; MATHEMATICAL ANALYSIS; PATIENT POSITIONING; PRIORITY JOURNAL; RADIATION DOSE DISTRIBUTION; STOCHASTIC MODEL; TARGET ORGAN; TREATMENT PLANNING;

EID: 2642683174     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/43/6/018     Document Type: Article
Times cited : (102)

References (17)
  • 4
    • 0027138281 scopus 로고
    • A verification procedure to improve patient setup accuracy using portal image
    • Bel A, Van Herk M, Bartolink H and Lebesque J V 1993 A verification procedure to improve patient setup accuracy using portal image Radiother. Oncol. 29 253-60
    • (1993) Radiother. Oncol. , vol.29 , pp. 253-260
    • Bel, A.1    Van Herk, M.2    Bartolink, H.3    Lebesque, J.V.4
  • 6
    • 0027531599 scopus 로고
    • Time trend of patient setup deviations during pelvic irradiation using electronic portal imaging
    • El-Gayed A A H, Bel A, Vijlbrief R, Bartelink H and Lebesque J V 1993 Time trend of patient setup deviations during pelvic irradiation using electronic portal imaging Radiother. Oncol. 26 162-71
    • (1993) Radiother. Oncol. , vol.26 , pp. 162-171
    • El-Gayed, A.A.H.1    Bel, A.2    Vijlbrief, R.3    Bartelink, H.4    Lebesque, J.V.5
  • 7
    • 0028347564 scopus 로고
    • A generalized pencil beam algorithm for optimization of radiation therapy
    • Gustafsson A, Lind B K and Brahme A 1994 A generalized pencil beam algorithm for optimization of radiation therapy Med. Phys. 21 343-56
    • (1994) Med. Phys. , vol.21 , pp. 343-356
    • Gustafsson, A.1    Lind, B.K.2    Brahme, A.3
  • 9
    • 0003418872 scopus 로고
    • Prescribing, recording and reporting photon beam therapy
    • Washington, DC: ICRU
    • ICRU 1993 Prescribing, recording and reporting photon beam therapy ICRU Report 50 (Washington, DC: ICRU)
    • (1993) ICRU Report , vol.50
  • 10
    • 0026656051 scopus 로고
    • Tumor and normal tissue responses to fractionated nonuniform dose delivery
    • Källman P, Ågren A-K and Brahme A 1992 Tumor and normal tissue responses to fractionated nonuniform dose delivery Int. J. Radiat. Biol. 62 249-62
    • (1992) Int. J. Radiat. Biol. , vol.62 , pp. 249-262
    • Källman, P.1    Ågren, A.-K.2    Brahme, A.3
  • 11
    • 0027241780 scopus 로고
    • Optimal radiation beam profiles considering uncertainties in beam patient alignment
    • Lind B K, Källman P, Sundelin B and Brahme A 1993 Optimal radiation beam profiles considering uncertainties in beam patient alignment Acta. Oncol. 32 331-42
    • (1993) Acta. Oncol. , vol.32 , pp. 331-342
    • Lind, B.K.1    Källman, P.2    Sundelin, B.3    Brahme, A.4
  • 12
    • 0003161330 scopus 로고
    • Optimal radiation beam profiles considering the stochastic process of patient positioning in fractionated radiation therapy
    • Löf J, Lind B K and Brahme A 1995 Optimal radiation beam profiles considering the stochastic process of patient positioning in fractionated radiation therapy Inverse Problems 11 1189-209
    • (1995) Inverse Problems , vol.11 , pp. 1189-1209
    • Löf, J.1    Lind, B.K.2    Brahme, A.3
  • 13
    • 0029790894 scopus 로고    scopus 로고
    • Modeling dose distributions from portal dose images using the convolution/superposition method
    • McNutt T R, Mackie T R, Recwerdt P and Paliwal B R 1996 Modeling dose distributions from portal dose images using the convolution/superposition method Med. Phys. 23 1381-92
    • (1996) Med. Phys. , vol.23 , pp. 1381-1392
    • McNutt, T.R.1    Mackie, T.R.2    Recwerdt, P.3    Paliwal, B.R.4
  • 14
    • 0011208258 scopus 로고
    • When and how to correct a patient setup
    • ed A R Hounsell, J M Wilkinson and P C Williams (Manchester: Christie Hospital NHS Trust)
    • Shalev S and Gluhchev G 1994 When and how to correct a patient setup Proc. 11th ICCR, the Use of Computers in Radiation Therapy ed A R Hounsell, J M Wilkinson and P C Williams (Manchester: Christie Hospital NHS Trust) pp 274-5
    • (1994) Proc. 11th ICCR, the use of Computers in Radiation Therapy , pp. 274-275
    • Shalev, S.1    Gluhchev, G.2
  • 17
    • 0028968538 scopus 로고
    • A new model for 'accept or reject' strategies in off-line and on-line megavoltage treatment evaluation
    • Yan D, Wong J W, Gustafson G and Martinez A 1995 A new model for 'accept or reject' strategies in off-line and on-line megavoltage treatment evaluation Int. J. Radiat. Oncol. Biol. Phys. 31 943-52
    • (1995) Int. J. Radiat. Oncol. Biol. Phys. , vol.31 , pp. 943-952
    • Yan, D.1    Wong, J.W.2    Gustafson, G.3    Martinez, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.