메뉴 건너뛰기




Volumn 66, Issue 2, 2003, Pages 203-216

Radiotherapy treatment planning of prostate cancer using magnetic resonance imaging alone

Author keywords

Conformal radiotherapy; Electron density bulk assignment; Magnetic resonance imaging; Prostate cancer; Radiotherapy treatment planning

Indexed keywords

ARTICLE; CANCER RADIOTHERAPY; CLINICAL ARTICLE; COMPUTER ASSISTED RADIOTHERAPY; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; DOSIMETRY; GEOMETRY; HUMAN; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; PROSTATE CANCER; RADIATION DOSE DISTRIBUTION; TECHNIQUE; TREATMENT PLANNING; TUMOR VOLUME;

EID: 0037297702     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0167-8140(02)00440-1     Document Type: Article
Times cited : (209)

References (22)
  • 1
    • 0031747017 scopus 로고    scopus 로고
    • Radiotherapy treatment planning of brain tumours using MRI alone
    • Beavis A.W., Gibbs P., Dealey R.A., Whitton V.J. Radiotherapy treatment planning of brain tumours using MRI alone. Br J Radiol. 71:1998;544-548.
    • (1998) Br J Radiol , vol.71 , pp. 544-548
    • Beavis, A.W.1    Gibbs, P.2    Dealey, R.A.3    Whitton, V.J.4
  • 2
    • 0027157683 scopus 로고
    • Decomposition of pencil beam kernels for fast dose calculations in three-dimensional treatment planning
    • Bortfeld T., Schlegel W., Rhein B. Decomposition of pencil beam kernels for fast dose calculations in three-dimensional treatment planning. Med Phys. 20:1993;311-318.
    • (1993) Med Phys , vol.20 , pp. 311-318
    • Bortfeld, T.1    Schlegel, W.2    Rhein, B.3
  • 3
    • 85031198912 scopus 로고    scopus 로고
    • 2001 Cancer Research Campaign
    • Cancer Research Campaign. Scientific Yearbook 2000-2002. 2001 Cancer Research Campaign, 2002.
    • (2002) Scientific Yearbook 2000-2002
  • 5
    • 0012359659 scopus 로고    scopus 로고
    • Mortality and Prevalence in the European Union 1996 estimates)
    • EUCAN. Cancer Incidence, Mortality and Prevalence in the European Union 1996 estimates), 1996.
    • (1996) Cancer Incidence
  • 6
    • 0031777574 scopus 로고    scopus 로고
    • Intra- and inter-observer variability in contouring prostate and seminal vesicles: Implications for conformal treatment planning
    • Fiorino C., Reni M., Bolognesi A., Cattaneo G.M., Calandrino R. Intra- and inter-observer variability in contouring prostate and seminal vesicles: implications for conformal treatment planning. Radiother Oncol. 47:1998;285-292.
    • (1998) Radiother Oncol , vol.47 , pp. 285-292
    • Fiorino, C.1    Reni, M.2    Bolognesi, A.3    Cattaneo, G.M.4    Calandrino, R.5
  • 7
    • 0027138280 scopus 로고
    • Fractionated stereotactically guided radiotherapy of head and neck tumors: A report on clinical use of a new system in 195 cases
    • Gademann G., Schlegel W., Debus J., Schad L., Bortfeld T., Hover K.H., Lorenz W.J., Wannenmacher M. Fractionated stereotactically guided radiotherapy of head and neck tumors: a report on clinical use of a new system in 195 cases. Radiother Oncol. 29:1993;205-213.
    • (1993) Radiother Oncol , vol.29 , pp. 205-213
    • Gademann, G.1    Schlegel, W.2    Debus, J.3    Schad, L.4    Bortfeld, T.5    Hover, K.H.6    Lorenz, W.J.7    Wannenmacher, M.8
  • 10
    • 0032980048 scopus 로고    scopus 로고
    • Comparison of MRI with CT for the radiotherapy planning of prostate cancer: A feasibility study
    • Khoo V.S., Padhani A.R., Tanner S.F., Finnigan D.J., Leach M.O., Dearnaley D.P. Comparison of MRI with CT for the radiotherapy planning of prostate cancer: a feasibility study. Br J Radiol. 72:1999;590-597.
    • (1999) Br J Radiol , vol.72 , pp. 590-597
    • Khoo, V.S.1    Padhani, A.R.2    Tanner, S.F.3    Finnigan, D.J.4    Leach, M.O.5    Dearnaley, D.P.6
  • 11
    • 0033773907 scopus 로고    scopus 로고
    • The width of margins in radiotherapy treatment plans
    • McKenzie A.L., van Herk M., Mijnheer B. The width of margins in radiotherapy treatment plans. Phys Med Biol. 45:2000;3331-3342.
    • (2000) Phys Med Biol , vol.45 , pp. 3331-3342
    • McKenzie, A.L.1    Van Herk, M.2    Mijnheer, B.3
  • 12
    • 0034332920 scopus 로고    scopus 로고
    • Reproducibility of geometric distortion in magnetic resonance imaging based on phantom studies
    • Mizowaki T., Nagata Y., Okajima K., Kokubo M., Negoro Y., Araki N., Hiraoka M. Reproducibility of geometric distortion in magnetic resonance imaging based on phantom studies. Radiother Oncol. 57:2000;237-242.
    • (2000) Radiother Oncol , vol.57 , pp. 237-242
    • Mizowaki, T.1    Nagata, Y.2    Okajima, K.3    Kokubo, M.4    Negoro, Y.5    Araki, N.6    Hiraoka, M.7
  • 13
    • 0033621916 scopus 로고    scopus 로고
    • A randomized study of the use of a customized immobilization system in the treatment of prostate cancer with conformal radiotherapy
    • Nutting C.M., Khoo V.S., Walker V., McNair H., Beardmore C., Norman A., Dearnaley D.P. A randomized study of the use of a customized immobilization system in the treatment of prostate cancer with conformal radiotherapy. Radiother Oncol. 54:2000;1-9.
    • (2000) Radiother Oncol , vol.54 , pp. 1-9
    • Nutting, C.M.1    Khoo, V.S.2    Walker, V.3    McNair, H.4    Beardmore, C.5    Norman, A.6    Dearnaley, D.P.7
  • 14
    • 0032850212 scopus 로고    scopus 로고
    • Clinical application of digitally-reconstructed radiographs generated from magnetic resonance imaging for intracranial lesions
    • Ramsey C.R., Arwood D., Scaperoth D., Oliver A.L. Clinical application of digitally-reconstructed radiographs generated from magnetic resonance imaging for intracranial lesions. Int J Radiat Oncol Biol Phys. 45:1999;797-802.
    • (1999) Int J Radiat Oncol Biol Phys , vol.45 , pp. 797-802
    • Ramsey, C.R.1    Arwood, D.2    Scaperoth, D.3    Oliver, A.L.4
  • 15
    • 0031763081 scopus 로고    scopus 로고
    • Magnetic resonance imaging based digitally reconstructed radiographs, virtual simulation, and three-dimensional treatment planning for brain neoplasms
    • Ramsey C.R., Oliver A.L. Magnetic resonance imaging based digitally reconstructed radiographs, virtual simulation, and three-dimensional treatment planning for brain neoplasms. Med Phys. 25:1998;1928-1934.
    • (1998) Med Phys , vol.25 , pp. 1928-1934
    • Ramsey, C.R.1    Oliver, A.L.2
  • 17
    • 0030586042 scopus 로고    scopus 로고
    • Prostate volumes defined by magnetic resonance imaging and computerized tomographic scans for three-dimensional conformal radiotherapy
    • Roach M., Faillace A.P., Malfatti C., Holland J., Hricak H. Prostate volumes defined by magnetic resonance imaging and computerized tomographic scans for three-dimensional conformal radiotherapy. Int J Radiat Oncol Biol Phys. 35:1996;1011-1018.
    • (1996) Int J Radiat Oncol Biol Phys , vol.35 , pp. 1011-1018
    • Roach, M.1    Faillace, A.P.2    Malfatti, C.3    Holland, J.4    Hricak, H.5
  • 18
    • 0028784185 scopus 로고
    • Evaluation of changes in the size and location of the prostate, seminal vesicles, bladder, and rectum during a course of external beam radiation therapy
    • Roeske J.C., Forman J.D., Mesina C.F., He T., Pelizzari C.A., Fontenla E., Vijayakumar S., Chen G.T. Evaluation of changes in the size and location of the prostate, seminal vesicles, bladder, and rectum during a course of external beam radiation therapy. Int J Radiat Oncol Biol Phys. 33:1995;1321-1329.
    • (1995) Int J Radiat Oncol Biol Phys , vol.33 , pp. 1321-1329
    • Roeske, J.C.1    Forman, J.D.2    Mesina, C.F.3    He, T.4    Pelizzari, C.A.5    Fontenla, E.6    Vijayakumar, S.7    Chen, G.T.8
  • 19
    • 0034237259 scopus 로고    scopus 로고
    • Target volume definition in conformal radiotherapy for prostate cancer: Quality assurance in the MRC RT-01 trial
    • Seddon B., Bidmead M., Wilson J., Khoo V., Dearnaley D. Target volume definition in conformal radiotherapy for prostate cancer: quality assurance in the MRC RT-01 trial. Radiother Oncol. 56:2000;73-83.
    • (2000) Radiother Oncol , vol.56 , pp. 73-83
    • Seddon, B.1    Bidmead, M.2    Wilson, J.3    Khoo, V.4    Dearnaley, D.5
  • 20
    • 0033864035 scopus 로고    scopus 로고
    • Radiotherapy planning of the pelvis using distortion corrected MR images: The removal of system distortions
    • Tanner S.F., Finnigan D.J., Khoo V.S., Mayles P., Dearnaley D.P., Leach M.O. Radiotherapy planning of the pelvis using distortion corrected MR images: the removal of system distortions. Phys Med Biol. 45:2000;2117-2132.
    • (2000) Phys Med Biol , vol.45 , pp. 2117-2132
    • Tanner, S.F.1    Finnigan, D.J.2    Khoo, V.S.3    Mayles, P.4    Dearnaley, D.P.5    Leach, M.O.6
  • 21
    • 0034237797 scopus 로고    scopus 로고
    • The probability of correct target dosage: Dose-population histograms for deriving treatment margins in radiotherapy
    • van Herk M., Remeijer P., Rasch C., Lebesque J.V. The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy. Int J Radiat Oncol Biol Phys. 47:2000;1121-1135.
    • (2000) Int J Radiat Oncol Biol Phys , vol.47 , pp. 1121-1135
    • Van Herk, M.1    Remeijer, P.2    Rasch, C.3    Lebesque, J.V.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.