메뉴 건너뛰기




Volumn 300, Issue 1-2, 2005, Pages 100-114

FL-CTL assay: Fluorolysometric determination of cell-mediated cytotoxicity using green fluorescent protein and red fluorescent protein expressing target cells

Author keywords

Antigen specific CTL function; CTL assay; Cytotoxic T lymphocytes; Fluorescent proteins; Fluorometric based CTL; GFP

Indexed keywords

GREEN FLUORESCENT PROTEIN; ISOLEUCYLTYROSYLSERYLTHREONYLVALYLALANYLSERYLSERYLLEUCINE; LENTIVIRUS VECTOR; MAJOR HISTOCOMPATIBILITY ANTIGEN CLASS 1; PEPTIDE DERIVATIVE; RED FLUORESCENT PROTEIN; UNCLASSIFIED DRUG;

EID: 20444390118     PISSN: 00221759     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jim.2005.02.010     Document Type: Article
Times cited : (22)

References (25)
  • 2
    • 0036595397 scopus 로고    scopus 로고
    • Cytotoxic T lymphocytes: All roads lead to death
    • M. Barry, and R.C. Bleackley Cytotoxic T lymphocytes: all roads lead to death Nat. Rev., Immunol. 2 2002 401
    • (2002) Nat. Rev., Immunol. , vol.2 , pp. 401
    • Barry, M.1    Bleackley, R.C.2
  • 4
    • 0014251127 scopus 로고
    • Quantitative assay of the lytic action of immune lymphoid cells on 51-Cr-labelled allogeneic target cells in vitro; Inhibition by isoantibody and by drugs
    • K.T. Brunner, J. Mauel, J.C. Cerottini, and B. Chapuis Quantitative assay of the lytic action of immune lymphoid cells on 51-Cr-labelled allogeneic target cells in vitro; inhibition by isoantibody and by drugs Immunology 14 1968 181
    • (1968) Immunology , vol.14 , pp. 181
    • Brunner, K.T.1    Mauel, J.2    Cerottini, J.C.3    Chapuis, B.4
  • 5
    • 0030970267 scopus 로고    scopus 로고
    • Single cell analyses of cytokine production
    • L.L. Carter, and S.L. Swain Single cell analyses of cytokine production Curr. Opin. Immunol. 9 1997 177
    • (1997) Curr. Opin. Immunol. , vol.9 , pp. 177
    • Carter, L.L.1    Swain, S.L.2
  • 6
    • 0042236934 scopus 로고    scopus 로고
    • Measuring T cell-mediated cytotoxicity using fluorogenic caspase substrates
    • A. Chahroudi, G. Silvestri, and M.B. Feinberg Measuring T cell-mediated cytotoxicity using fluorogenic caspase substrates Methods 31 2003 120
    • (2003) Methods , vol.31 , pp. 120
    • Chahroudi, A.1    Silvestri, G.2    Feinberg, M.B.3
  • 7
    • 0037079725 scopus 로고    scopus 로고
    • Targeting transgene expression to antigen-presenting cells derived from lentivirus-transduced engrafting human hematopoietic stem/progenitor cells
    • Y. Cui, J. Golob, E. Kelleher, Z. Ye, D. Pardoll, and L. Cheng Targeting transgene expression to antigen-presenting cells derived from lentivirus-transduced engrafting human hematopoietic stem/progenitor cells Blood 99 2002 399
    • (2002) Blood , vol.99 , pp. 399
    • Cui, Y.1    Golob, J.2    Kelleher, E.3    Ye, Z.4    Pardoll, D.5    Cheng, L.6
  • 8
    • 0037234069 scopus 로고    scopus 로고
    • Beyond six colors: A new era in flow cytometry
    • S.C. De Rosa, J.M. Brenchley, and M. Roederer Beyond six colors: a new era in flow cytometry Nat. Med. 9 2003 112
    • (2003) Nat. Med. , vol.9 , pp. 112
    • De Rosa, S.C.1    Brenchley, J.M.2    Roederer, M.3
  • 9
    • 0036157469 scopus 로고    scopus 로고
    • Prime-boost immunization generates a high frequency, high-avidity CD8(+) cytotoxic T lymphocyte population
    • M.J. Estcourt, A.J. Ramsay, A. Brooks, S.A. Thomson, C.J. Medveckzy, and I.A. Ramshaw Prime-boost immunization generates a high frequency, high-avidity CD8(+) cytotoxic T lymphocyte population Int. Immunol. 14 2002 31
    • (2002) Int. Immunol. , vol.14 , pp. 31
    • Estcourt, M.J.1    Ramsay, A.J.2    Brooks, A.3    Thomson, S.A.4    Medveckzy, C.J.5    Ramshaw, I.A.6
  • 11
    • 0035102830 scopus 로고    scopus 로고
    • "rainbow" reporters for multispectral marking and lineage analysis of hematopoietic stem cells
    • T.S. Hawley, W.G. Telford, and R.G. Hawley "Rainbow" reporters for multispectral marking and lineage analysis of hematopoietic stem cells Stem Cells 19 2001 118
    • (2001) Stem Cells , vol.19 , pp. 118
    • Hawley, T.S.1    Telford, W.G.2    Hawley, R.G.3
  • 12
    • 0442276553 scopus 로고    scopus 로고
    • The VITAL assay: A versatile fluorometric technique for assessing CTL- and NKT-mediated cytotoxicity against multiple targets in vitro and in vivo
    • I.F. Hermans, J.D. Silk, J. Yang, M.J. Palmowski, U. Gileadi, C. McCarthy, M. Salio, F. Ronchese, and V. Cerundolo The VITAL assay: a versatile fluorometric technique for assessing CTL- and NKT-mediated cytotoxicity against multiple targets in vitro and in vivo J. Immunol. Methods 285 2004 25
    • (2004) J. Immunol. Methods , vol.285 , pp. 25
    • Hermans, I.F.1    Silk, J.D.2    Yang, J.3    Palmowski, M.J.4    Gileadi, U.5    McCarthy, C.6    Salio, M.7    Ronchese, F.8    Cerundolo, V.9
  • 13
    • 0037106009 scopus 로고    scopus 로고
    • A flow-cytometry based cytotoxicity assay using stained effector cells in combination with native target cells
    • M. Hoppner, J. Luhm, P. Schlenke, P. Koritke, and C. Frohn A flow-cytometry based cytotoxicity assay using stained effector cells in combination with native target cells J. Immunol. Methods 267 2002 157
    • (2002) J. Immunol. Methods , vol.267 , pp. 157
    • Hoppner, M.1    Luhm, J.2    Schlenke, P.3    Koritke, P.4    Frohn, C.5
  • 15
    • 0037105972 scopus 로고    scopus 로고
    • The fluorolysis assay, a highly sensitive method for measuring the cytolytic activity of T cells at very low numbers
    • N. Kienzle, S. Olver, K. Buttigieg, and A. Kelso The fluorolysis assay, a highly sensitive method for measuring the cytolytic activity of T cells at very low numbers J. Immunol. Methods 267 2002 99
    • (2002) J. Immunol. Methods , vol.267 , pp. 99
    • Kienzle, N.1    Olver, S.2    Buttigieg, K.3    Kelso, A.4
  • 17
    • 0035400281 scopus 로고    scopus 로고
    • A novel flow cytometric assay for quantitation and multiparametric characterization of cell-mediated cytotoxicity
    • H. Lecoeur, M. Fevrier, S. Garcia, Y. Riviere, and M.L. Gougeon A novel flow cytometric assay for quantitation and multiparametric characterization of cell-mediated cytotoxicity J. Immunol. Methods 253 2001 177
    • (2001) J. Immunol. Methods , vol.253 , pp. 177
    • Lecoeur, H.1    Fevrier, M.2    Garcia, S.3    Riviere, Y.4    Gougeon, M.L.5
  • 18
    • 0038725690 scopus 로고    scopus 로고
    • The ABCs of granule-mediated cytotoxicity: New weapons in the arsenal
    • J. Lieberman The ABCs of granule-mediated cytotoxicity: new weapons in the arsenal Nat. Rev., Immunol. 3 2003 361
    • (2003) Nat. Rev., Immunol. , vol.3 , pp. 361
    • Lieberman, J.1
  • 19
    • 0025792001 scopus 로고
    • The JAM test. a simple assay for DNA fragmentation and cell death
    • P. Matzinger The JAM test. A simple assay for DNA fragmentation and cell death J. Immunol. Methods 145 1991 185
    • (1991) J. Immunol. Methods , vol.145 , pp. 185
    • Matzinger, P.1
  • 21
    • 0032534058 scopus 로고    scopus 로고
    • Differentiation of naive CTL to effector and memory CTL: Correlation of effector function with phenotype and cell division
    • S. Oehen, and K. Brduscha-Riem Differentiation of naive CTL to effector and memory CTL: correlation of effector function with phenotype and cell division J. Immunol. 161 1998 5338
    • (1998) J. Immunol. , vol.161 , pp. 5338
    • Oehen, S.1    Brduscha-Riem, K.2
  • 23
    • 0345535132 scopus 로고    scopus 로고
    • Measuring the frequency of mouse and human cytotoxic T cells by the Lysispot assay: Independent regulation of cytokine secretion and short-term killing
    • J.E. Snyder, W.J. Bowers, A.M. Livingstone, F.E. Lee, H.J. Federoff, and T.R. Mosmann Measuring the frequency of mouse and human cytotoxic T cells by the Lysispot assay: independent regulation of cytokine secretion and short-term killing Nat. Med. 9 2003 231
    • (2003) Nat. Med. , vol.9 , pp. 231
    • Snyder, J.E.1    Bowers, W.J.2    Livingstone, A.M.3    Lee, F.E.4    Federoff, H.J.5    Mosmann, T.R.6
  • 24
    • 1842631484 scopus 로고    scopus 로고
    • Immediate cytotoxicity but not degranulation distinguishes effector and memory subsets of CD8+ T Cells
    • P. Wolint, M.R. Betts, R.A. Koup, and A. Oxenius Immediate cytotoxicity but not degranulation distinguishes effector and memory subsets of CD8+ T Cells J. Exp. Med. 199 2004 925
    • (2004) J. Exp. Med. , vol.199 , pp. 925
    • Wolint, P.1    Betts, M.R.2    Koup, R.A.3    Oxenius, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.