-
1
-
-
0030923837
-
In vitro comparison of the amount of salbutamol available for inhalation from different formulations used with different spacer devices
-
P. W. Barry and C. O'Callaghan. In vitro comparison of the amount of salbutamol available for inhalation from different formulations used with different spacer devices. Eur. Respir. J. 10: 1345-1348 (1997).
-
(1997)
Eur. Respir. J.
, vol.10
, pp. 1345-1348
-
-
Barry, P.W.1
O'Callaghan, C.2
-
2
-
-
0036321272
-
Targeting delivery of aerosols to different lung regions
-
W. D. Bennett, J. S. Brown, K. L. Zeman, S. C. Hu, G. Scheuch, and K. Sommerer. Targeting delivery of aerosols to different lung regions. J. Aerosol Med. 15:179-188 (2002).
-
(2002)
J. Aerosol Med.
, vol.15
, pp. 179-188
-
-
Bennett, W.D.1
Brown, J.S.2
Zeman, K.L.3
Hu, S.C.4
Scheuch, G.5
Sommerer, K.6
-
4
-
-
6544232840
-
Performance of large-volume versus small volume holding chambers with chlorofluorocarbon-albuterol and hydrofluoroalkane-albuterol sulfate
-
J. P. Mitchell, M. W. Nagel, and J. L. Rau. Performance of large-volume versus small volume holding chambers with chlorofluorocarbon-albuterol and hydrofluoroalkane-albuterol sulfate. Respir. Care 44:38-44 (1999).
-
(1999)
Respir. Care
, vol.44
, pp. 38-44
-
-
Mitchell, J.P.1
Nagel, M.W.2
Rau, J.L.3
-
5
-
-
0031983971
-
Salbutamol delivery from a hydrofluoroalkane pressurized metered-dose inhaler in pediatric ventilator circuits: An in vitro study
-
J. H. Wildhaber, M. J. Hayden, N. D. Dore, S. G. Devadason, and P. N. LeSouef. Salbutamol delivery from a hydrofluoroalkane pressurized metered-dose inhaler in pediatric ventilator circuits: an in vitro study. Chest 113:186-191 (1998).
-
(1998)
Chest
, vol.113
, pp. 186-191
-
-
Wildhaber, J.H.1
Hayden, M.J.2
Dore, N.D.3
Devadason, S.G.4
LeSouef, P.N.5
-
6
-
-
0029804408
-
Effect of electrostatic charge, flow, delay and multiple actuations on the in vitro delivery of salbutamol from different small volume spacers for infants
-
J. H. Wildhaber, S. G. Devadason, E. Eber, M. J. Hayden, M. L. Everard, Q. A. Summers, and P. N. LeSouef. Effect of electrostatic charge, flow, delay and multiple actuations on the in vitro delivery of salbutamol from different small volume spacers for infants. Thorax 51:985-988 (1996).
-
(1996)
Thorax
, vol.51
, pp. 985-988
-
-
Wildhaber, J.H.1
Devadason, S.G.2
Eber, E.3
Hayden, M.J.4
Everard, M.L.5
Summers, Q.A.6
LeSouef, P.N.7
-
7
-
-
2542509095
-
Washing plastic spacers in household detergent reduces electrostatic charge and greatly improves delivery
-
F. Pierart, J. H. Wildhaber, I. Vrancken, S. G. Devadason, and P. N. Le Souef. Washing plastic spacers in household detergent reduces electrostatic charge and greatly improves delivery. Eur. Respir. J. 13:673-678 (1999).
-
(1999)
Eur. Respir. J.
, vol.13
, pp. 673-678
-
-
Pierart, F.1
Wildhaber, J.H.2
Vrancken, I.3
Devadason, S.G.4
Le Souef, P.N.5
-
8
-
-
0029144971
-
In vitro properties of pressurized metered dose inhalers with and without spacer devices
-
E. Berg. In vitro properties of pressurized metered dose inhalers with and without spacer devices. J. Aerosol Med. 8(Suppl 3):S3-10 (1995).
-
(1995)
J. Aerosol Med.
, vol.8
, Issue.3 SUPPL.
-
-
Berg, E.1
-
9
-
-
0036195113
-
Adhesion of powders for inhalation: An evaluation of drug detachment from surfaces following deposition from aerosol streams
-
M. J. Clarke, J. Peart, S. Cagnani, and P. R. Byron. Adhesion of powders for inhalation: an evaluation of drug detachment from surfaces following deposition from aerosol streams. Pharm. Res. 19:322-329 (2002).
-
(2002)
Pharm. Res.
, vol.19
, pp. 322-329
-
-
Clarke, M.J.1
Peart, J.2
Cagnani, S.3
Byron, P.R.4
-
10
-
-
0029792378
-
Electrostatic charge on a plastic spacer device influences the delivery of salbutamol
-
J. H. Wildhaber, S. G. Devadason, M. J. Hayden, R. James, A. P. Dufty, R. A. Fox, Q. A. Summers, and P. N. LeSouef. Electrostatic charge on a plastic spacer device influences the delivery of salbutamol. Eur. Respir. J. 9:1943-1946 (1996).
-
(1996)
Eur. Respir. J.
, vol.9
, pp. 1943-1946
-
-
Wildhaber, J.H.1
Devadason, S.G.2
Hayden, M.J.3
James, R.4
Dufty, A.P.5
Fox, R.A.6
Summers, Q.A.7
LeSouef, P.N.8
-
11
-
-
0035129329
-
Randomised controlled study of clinical efficacy of spacer therapy in asthma with regard to electrostatic charge
-
E. Dompeling, A. M. Oudesluys-Murphy, H. M. Janssens, W. Hop, J. G. Brinkman, R. N. Sukhai, and J. C. de Jongste. Randomised controlled study of clinical efficacy of spacer therapy in asthma with regard to electrostatic charge. Arch. Dis. Child. 4: 178-182 (2001).
-
(2001)
Arch. Dis. Child.
, vol.4
, pp. 178-182
-
-
Dompeling, E.1
Oudesluys-Murphy, A.M.2
Janssens, H.M.3
Hop, W.4
Brinkman, J.G.5
Sukhai, R.N.6
De Jongste, J.C.7
-
12
-
-
0000457653
-
Gravitational deposition of aerosol particles within a system of randomly oriented tubes
-
J. Heyder. Gravitational deposition of aerosol particles within a system of randomly oriented tubes. Aerosol Sci. 6:133-137 (1976).
-
(1976)
Aerosol Sci.
, vol.6
, pp. 133-137
-
-
Heyder, J.1
-
14
-
-
0031813943
-
In vitro performance of three combinations of spacers and pressurized metered dose inhalers for treatment in children
-
E. Berg, J. Madsen, and H. Bisgaard. In vitro performance of three combinations of spacers and pressurized metered dose inhalers for treatment in children. Eur. Respir. J. 12:472-476 (1998).
-
(1998)
Eur. Respir. J.
, vol.12
, pp. 472-476
-
-
Berg, E.1
Madsen, J.2
Bisgaard, H.3
-
15
-
-
0027316392
-
Improvement in sodium cromoglycate delivery from a spacer device by use of an antistatic lining, immediate inhalation, and avoiding multiple actuations of drug
-
C. O'Callaghan, J. Lynch, M. Cant, and C. Robertson. Improvement in sodium cromoglycate delivery from a spacer device by use of an antistatic lining, immediate inhalation, and avoiding multiple actuations of drug. Thorax 48:603-606 (1993).
-
(1993)
Thorax
, vol.48
, pp. 603-606
-
-
O'Callaghan, C.1
Lynch, J.2
Cant, M.3
Robertson, C.4
|