메뉴 건너뛰기




Volumn 136, Issue 3, 2005, Pages 323-330

Assessing the accuracy of caries diagnosis via radiograph: Film versus print

Author keywords

Caries diagnoses; Copying processes; Ink jet printer; Paper; Receiving operating characteristic; statistic

Indexed keywords

ARTICLE; DENTAL CARIES; DENTIST; DIAGNOSTIC ACCURACY; ENAMEL; TOOTH RADIOGRAPHY; X RAY FILM; COMPARATIVE STUDY; EVALUATION; HUMAN; METHODOLOGY; OBSERVER VARIATION; PAPER; PHOTOGRAPHY; PRINTING; RADIOGRAPHY; RECORDING; ROC CURVE; SENSITIVITY AND SPECIFICITY;

EID: 17144428597     PISSN: 00028177     EISSN: None     Source Type: Journal    
DOI: 10.14219/jada.archive.2005.0172     Document Type: Article
Times cited : (14)

References (24)
  • 1
    • 0023390744 scopus 로고
    • The radiographic detection of initial carious lesions on the proximal surfaces of teeth, Part II: The influence of viewing conditions
    • Arnold LV. The radiographic detection of initial carious lesions on the proximal surfaces of teeth, Part II: the influence of viewing conditions. Oral Surg Oral Med Oral Pathol 1987;64(2):232-40.
    • (1987) Oral Surg Oral Med Oral Pathol , vol.64 , Issue.2 , pp. 232-240
    • Arnold, L.V.1
  • 2
    • 0029395615 scopus 로고
    • Effect of image magnification of digitized bitewing radiographs on approximal caries detection: An in vitro study
    • Moystad A, Svanaes DB, Larheim TA, Grondahl HG. Effect of image magnification of digitized bitewing radiographs on approximal caries detection: an in vitro study. Dentomaxillofac Radiol 1995;24(4):255-9.
    • (1995) Dentomaxillofac Radiol , vol.24 , Issue.4 , pp. 255-259
    • Moystad, A.1    Svanaes, D.B.2    Larheim, T.A.3    Grondahl, H.G.4
  • 3
    • 0030185536 scopus 로고    scopus 로고
    • Intraoral storage phosphor radiography for approximal caries detection and effect of image magnification: Comparison with conventional radiography
    • Svanaes DB, Moystad A, Risnes S, Larheim TA, Grondahl HG. Intraoral storage phosphor radiography for approximal caries detection and effect of image magnification: comparison with conventional radiography. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 1996;82(1):94-100.
    • (1996) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.82 , Issue.1 , pp. 94-100
    • Svanaes, D.B.1    Moystad, A.2    Risnes, S.3    Larheim, T.A.4    Grondahl, H.G.5
  • 4
    • 0032015895 scopus 로고    scopus 로고
    • Reduction in size of digital images: Does it lead to less detectability or loss of diagnostic information?
    • Versteeg CH, Sanderink GC, Lobach SR, van der Stelt PF. Reduction in size of digital images: does it lead to less detectability or loss of diagnostic information? Dentomaxillofac Radiol 1998;27(2):93-6.
    • (1998) Dentomaxillofac Radiol , vol.27 , Issue.2 , pp. 93-96
    • Versteeg, C.H.1    Sanderink, G.C.2    Lobach, S.R.3    Van Der Stelt, P.F.4
  • 5
    • 85030804743 scopus 로고
    • Video resolution requirements for novice observers for the diagnosis of dental-caries
    • abstract 1052
    • Navarro M, Otis L. Video resolution requirements for novice observers for the diagnosis of dental-caries (abstract 1052). J Dent Res 1995;74:143.
    • (1995) J Dent Res , vol.74 , pp. 143
    • Navarro, M.1    Otis, L.2
  • 8
    • 0020524559 scopus 로고
    • A method of comparing the areas under receiver operating characteristic curves derived from the same cases
    • Hanley JA, McNeil BJ. A method of comparing the areas under receiver operating characteristic curves derived from the same cases. Radiology 1983;148(3):839-43.
    • (1983) Radiology , vol.148 , Issue.3 , pp. 839-843
    • Hanley, J.A.1    McNeil, B.J.2
  • 9
    • 0017360990 scopus 로고
    • The measurement of observer agreement for categorical data
    • Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics 1977;33(1):159-74.
    • (1977) Biometrics , vol.33 , Issue.1 , pp. 159-174
    • Landis, J.R.1    Koch, G.G.2
  • 10
    • 0035289844 scopus 로고    scopus 로고
    • Performance of RVGui sensor and Kodak Ektaspeed Plus film for proximal caries detection
    • Abreu M Jr, Mol A, Ludlow JB. Performance of RVGui sensor and Kodak Ektaspeed Plus film for proximal caries detection. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2001;91(3):381-5.
    • (2001) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.91 , Issue.3 , pp. 381-385
    • Abreu Jr., M.1    Mol, A.2    Ludlow, J.B.3
  • 11
    • 0035344310 scopus 로고    scopus 로고
    • Conventional, digital and contrast-enhanced bitewing radiographs in the decision to restore approximal carious lesions
    • Haak R, Wicht MJ, Noack MJ. Conventional, digital and contrast-enhanced bitewing radiographs in the decision to restore approximal carious lesions. Caries Res 2001;35(3):193-9.
    • (2001) Caries Res , vol.35 , Issue.3 , pp. 193-199
    • Haak, R.1    Wicht, M.J.2    Noack, M.J.3
  • 12
    • 0036559422 scopus 로고    scopus 로고
    • Accuracy of caries detection with four storage phosphor systems and E-speed radiographs
    • Hintze H, Wenzel A, Frydenberg M. Accuracy of caries detection with four storage phosphor systems and E-speed radiographs. Dentomaxillofac Radiol 2002;31(3):170-5.
    • (2002) Dentomaxillofac Radiol , vol.31 , Issue.3 , pp. 170-175
    • Hintze, H.1    Wenzel, A.2    Frydenberg, M.3
  • 13
    • 0036370699 scopus 로고    scopus 로고
    • Influence of the validation method on diagnostic accuracy for caries: A comparison of six digital and two conventional radiographic systems
    • Hintze H, Wenzel A. Influence of the validation method on diagnostic accuracy for caries: a comparison of six digital and two conventional radiographic systems. Dentomaxillofac Radiol 2002;31(1):44-9.
    • (2002) Dentomaxillofac Radiol , vol.31 , Issue.1 , pp. 44-49
    • Hintze, H.1    Wenzel, A.2
  • 14
    • 0035463180 scopus 로고    scopus 로고
    • An in-vitro evaluation of Kodak Insight and Ektaspeed Plus film with a CMOS detector for natural proximal caries: ROC analysis
    • Nair MK, Nair UP. An in-vitro evaluation of Kodak Insight and Ektaspeed Plus film with a CMOS detector for natural proximal caries: ROC analysis. Caries Res 2001;35(5):354-9.
    • (2001) Caries Res , vol.35 , Issue.5 , pp. 354-359
    • Nair, M.K.1    Nair, U.P.2
  • 15
    • 0030622295 scopus 로고    scopus 로고
    • Comparative performance of digital and conventional images for detecting proximal surface caries
    • White SC, Yoon DC. Comparative performance of digital and conventional images for detecting proximal surface caries. Dentomaxillofac Radiol 1997;26(1):32-8.
    • (1997) Dentomaxillofac Radiol , vol.26 , Issue.1 , pp. 32-38
    • White, S.C.1    Yoon, D.C.2
  • 16
    • 0032150493 scopus 로고    scopus 로고
    • Effect of different background lighting conditions on diagnostic performance of digital and film images
    • Cederberg RA, Frederiksen NL, Benson BW, Shulman JD. Effect of different background lighting conditions on diagnostic performance of digital and film images. Dentomaxillofac Radiol 1998;27(5):293-7.
    • (1998) Dentomaxillofac Radiol , vol.27 , Issue.5 , pp. 293-297
    • Cederberg, R.A.1    Frederiksen, N.L.2    Benson, B.W.3    Shulman, J.D.4
  • 18
    • 0028431739 scopus 로고
    • Evaluation of the image quality of ink-jet printed paper copies of digital chest radiographs as compared with film: A receiver operating characteristic study
    • Lyttkens K, Kirkhorn T, Kehler M, et al. Evaluation of the image quality of ink-jet printed paper copies of digital chest radiographs as compared with film: a receiver operating characteristic study. J Digit Imaging 1994;7(2):61-8.
    • (1994) J Digit Imaging , vol.7 , Issue.2 , pp. 61-68
    • Lyttkens, K.1    Kirkhorn, T.2    Kehler, M.3
  • 20
    • 0034323618 scopus 로고    scopus 로고
    • Approximal caries depth assessment with storage phosphor versus film radiography: Evaluation of the caries-specific Oslo enhancement procedure
    • Svanaes DB, Moystad A, Larheim TA. Approximal caries depth assessment with storage phosphor versus film radiography: evaluation of the caries-specific Oslo enhancement procedure. Caries Res 2000;34(6):448-53.
    • (2000) Caries Res , vol.34 , Issue.6 , pp. 448-453
    • Svanaes, D.B.1    Moystad, A.2    Larheim, T.A.3
  • 21
    • 0028708602 scopus 로고
    • In vitro comparison of D- and E-speed film radiography, RVG, and visualix digital radiography for the detection of enamel approximal and dentinal occlusal caries lesions
    • Hintze H, Wenzel A, Jones C. In vitro comparison of D- and E-speed film radiography, RVG, and visualix digital radiography for the detection of enamel approximal and dentinal occlusal caries lesions. Caries Res 1994;28(5):363-7.
    • (1994) Caries Res , vol.28 , Issue.5 , pp. 363-367
    • Hintze, H.1    Wenzel, A.2    Jones, C.3
  • 22
    • 0032614659 scopus 로고    scopus 로고
    • Developments in caries diagnosis and their relationship to treatment decisions and quality of care: ORCA Saturday Afternoon Symposium 1997
    • Verdonschot EH, Angmar-Mansson B, ten Bosch JJ, et al. Developments in caries diagnosis and their relationship to treatment decisions and quality of care: ORCA Saturday Afternoon Symposium 1997. Caries Res 1999;33(1):32-40.
    • (1999) Caries Res , vol.33 , Issue.1 , pp. 32-40
    • Verdonschot, E.H.1    Angmar-Mansson, B.2    Ten Bosch, J.J.3
  • 23
    • 0031062663 scopus 로고    scopus 로고
    • Diagnostic tools and measurements: Impact on appropriate care
    • Pitts NB. Diagnostic tools and measurements: impact on appropriate care. Community Dent Oral Epidemiol 1997;25(1):24-35.
    • (1997) Community Dent Oral Epidemiol , vol.25 , Issue.1 , pp. 24-35
    • Pitts, N.B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.