-
1
-
-
0041561015
-
Acoustic phenomena and valve dysfunction in cardiac prostheses: Data acquisition and collection via the Internet
-
Eitz T, Fritzsche D, Grimmig O et al. Acoustic phenomena and valve dysfunction in cardiac prostheses: data acquisition and collection via the Internet. J. Heart Valve Dis. 12(4), 414 419 (2003).
-
(2003)
J. Heart Valve Dis.
, vol.12
, Issue.4
, pp. 414-419
-
-
Eitz, T.1
Fritzsche, D.2
Grimmig, O.3
-
2
-
-
0026848766
-
2D color-mapping of turbulent shear stress distribution downstream of two aortic bioprosthetic valves in vitro
-
Nygaard H, Giersiepen M, Hasenkam JM et al. 2D color-mapping of turbulent shear stress distribution downstream of two aortic bioprosthetic valves in vitro. J. Biomech. 25(4), 429 440 (1992).
-
(1992)
J. Biomech.
, vol.25
, Issue.4
, pp. 429-440
-
-
Nygaard, H.1
Giersiepen, M.2
Hasenkam, J.M.3
-
3
-
-
0016446510
-
Deformation and fragmentation of human blood cells in turbulent shear flow
-
Sutera SP, Mehrjardi MH. Deformation and fragmentation of human blood cells in turbulent shear flow. Biophys. J. 15, 1-10 (1975).
-
(1975)
Biophys. J.
, vol.15
, pp. 1-10
-
-
Sutera, S.P.1
Mehrjardi, M.H.2
-
4
-
-
0034117926
-
On the monodimensional approach to the estimation of the highest Reynolds shear stress in a turbulent flow
-
Grigioni M, Daniele C, D'Avenio G, Barbaro V. On the monodimensional approach to the estimation of the highest Reynolds shear stress in a turbulent flow. J. Biomech. 33(6), 701 708 (2000).
-
(2000)
J. Biomech.
, vol.33
, Issue.6
, pp. 701-708
-
-
Grigioni, M.1
Daniele, C.2
D'Avenio, G.3
Barbaro, V.4
-
5
-
-
0016303196
-
Measured turbulence and its effect on thrombus formation
-
Stein PD, Sabbah HN Measured turbulence and its effect on thrombus formation. Circ. Res. 35, 608 614 (1974).
-
(1974)
Circ. Res.
, vol.35
, pp. 608-614
-
-
Stein, P.D.1
Sabbah, H.N.2
-
6
-
-
0021685904
-
Human red blood cell hemolysis in a turbulent shear flow: Contribution of Reynolds shear stresses
-
Sallam, AM, Hwang, NHC. Human red blood cell hemolysis in a turbulent shear flow: contribution of Reynolds shear stresses. Biorheology 21, 783 797 (1984).
-
(1984)
Biorheology
, vol.21
, pp. 783-797
-
-
Sallam, A.M.1
Hwang, N.H.C.2
-
7
-
-
0022413279
-
A 6-year experience with the St. Jude Medical valve: Hemodynamic performance, surgical results, biocompatibility and follow-up
-
Czer LSC, Matloff J, Chaux A et al. A 6-year experience with the St. Jude Medical valve: hemodynamic performance, surgical results, biocompatibility and follow-up. J. Am. Coll. Cardiol. 6, 904 912 (1985).
-
(1985)
J. Am. Coll. Cardiol.
, vol.6
, pp. 904-912
-
-
Czer, L.S.C.1
Matloff, J.2
Chaux, A.3
-
8
-
-
1642354879
-
Lowering the intensity of oral anticoagulant therapy: Effects on the risk of hemorrhage and thromboembolism
-
Torn M, van der Meer FJ, Rosendaal FR. Lowering the intensity of oral anticoagulant therapy: effects on the risk of hemorrhage and thromboembolism. Arch. Intern. Med. 164(6), 668 673 (2004).
-
(2004)
Arch. Intern. Med.
, vol.164
, Issue.6
, pp. 668-673
-
-
Torn, M.1
van der Meer, F.J.2
Rosendaal, F.R.3
-
10
-
-
0002528945
-
Laser velocimetry
-
Goldstein RJ (Ed.). Hemisphere Publishing Corp., NY, USA
-
Adrian RJ. Laser velocimetry. In: Fluid Mechanics Measurements. Goldstein RJ (Ed.). Hemisphere Publishing Corp., NY, USA (1983).
-
(1983)
Fluid Mechanics Measurements
-
-
Adrian, R.J.1
-
12
-
-
36149056427
-
A bipolar two component laser velocimeter
-
Adrian RJ. A bipolar two component laser velocimeter. J. Phys. E. 4, 72 75 (1975).
-
(1975)
J. Phys. E.
, vol.4
, pp. 72-75
-
-
Adrian, R.J.1
-
13
-
-
0000415159
-
A new theoretical model for the laser doppler meter
-
Rudd MJ. A new theoretical model for the laser doppler meter. J. Phys. E. 2, 723-726 (1969).
-
(1969)
J. Phys. E.
, vol.2
, pp. 723-726
-
-
Rudd, M.J.1
-
14
-
-
0032170007
-
Time-frequency analysis of the noise produced by the closing of the artificial heart valves: An in vitro study
-
Masson C, Rieu R. Time-frequency analysis of the noise produced by the closing of the artificial heart valves: an in vitro study. Med. Eng. Phys. 20, 418-431 (1998).
-
(1998)
Med. Eng. Phys.
, vol.20
, pp. 418-431
-
-
Masson, C.1
Rieu, R.2
-
16
-
-
0001325535
-
Wavelet transform
-
Poularikas AD (Ed.). CRC Press, FL, USA
-
Sheng Y. Wavelet transform. In: The Transforms And Applications Handbook. Poularikas AD (Ed.). CRC Press, FL, USA, 747-827 (1996).
-
(1996)
The Transforms and Applications Handbook
, pp. 747-827
-
-
Sheng, Y.1
-
17
-
-
0028220162
-
In vitro heart valve testing: Steady versus pulsatile flow
-
Black MM, Hose DR, Lamb CJ, Lawford PV, Ralph SJ. In vitro heart valve testing: steady versus pulsatile flow. J. Heart Valve Dis. 3(2), 212-215 (1994).
-
(1994)
J. Heart Valve Dis.
, vol.3
, Issue.2
, pp. 212-215
-
-
Black, M.M.1
Hose, D.R.2
Lamb, C.J.3
Lawford, P.V.4
Ralph, S.J.5
-
18
-
-
0030152830
-
Identification of peak stresses in cardiac prostheses. A comparison of two-dimensional versus 3D principal stress analysis
-
Fontaine AA, Ellis JT, Healy TM, Hopmeyer J, Yoganathan AP. Identification of peak stresses in cardiac prostheses. A comparison of two-dimensional versus 3D principal stress analysis. ASAIO J. 42(3), 154-163 (1996).
-
(1996)
ASAIO J.
, vol.42
, Issue.3
, pp. 154-163
-
-
Fontaine, A.A.1
Ellis, J.T.2
Healy, T.M.3
Hopmeyer, J.4
Yoganathan, A.P.5
-
19
-
-
0027703644
-
Determination of principal Reynolds stresses in pulsatile flows after elliptical filtering of discrete velocity measurements
-
Baldwin JT, Deutsch S, Petrie, HL, Tarbell JM. Determination of principal Reynolds stresses in pulsatile flows after elliptical filtering of discrete velocity measurements. J. Biomech. Eng. 115, 396-403 (1993).
-
(1993)
J. Biomech. Eng.
, vol.115
, pp. 396-403
-
-
Baldwin, J.T.1
Deutsch, S.2
Petrie, H.L.3
Tarbell, J.M.4
-
20
-
-
0034132947
-
Laser Doppler anemometry study of bidimensional flows downstream of three 19 mm bileaflet valves in the mitral position, under kinematic similarity
-
Grigioni M, Daniele C, D'Avenio G, Barbaro V. Laser Doppler anemometry study of bidimensional flows downstream of three 19 mm bileaflet valves in the mitral position, under kinematic similarity. Ann. Biomed. Eng. 28(2), 194-203 (2000).
-
(2000)
Ann. Biomed. Eng.
, vol.28
, Issue.2
, pp. 194-203
-
-
Grigioni, M.1
Daniele, C.2
D'Avenio, G.3
Barbaro, V.4
-
21
-
-
0003709048
-
-
Prentice-Hall, Inc., Englewood Cliffs, NJ, USA
-
Malvern, LE. Introduction To The Mechanics Of A Continuous Medium. Prentice-Hall, Inc., Englewood Cliffs, NJ, USA, (1977).
-
(1977)
Introduction to the Mechanics of a Continuous Medium
-
-
Malvern, L.E.1
-
22
-
-
0031464974
-
19 mm sized bileaflet valve prostheses' flow field investigated by bidimensional laser Doppler anemometry (Part I: Velocity profiles)
-
Barbaro V, Grigioni M, Daniele C, D'Avenio G, Boccanera G. 19 mm sized bileaflet valve prostheses' flow field investigated by bidimensional laser Doppler anemometry (Part I: velocity profiles). Int. J. Artif. Organs 20 (11), 622-628 (1997).
-
(1997)
Int. J. Artif. Organs
, vol.20
, Issue.11
, pp. 622-628
-
-
Barbaro, V.1
Grigioni, M.2
Daniele, C.3
D'Avenio, G.4
Boccanera, G.5
-
23
-
-
0031450911
-
19 mm sized bileaflet valve prostheses' flow field investigated by bidimensional laser Doppler anemometry (Part II: Maximum turbulent turbulent shear stress)
-
Barbaro V, Grigioni M, Daniele C, D'Avenio G, Boccanera G. 19 mm sized bileaflet valve prostheses' flow field investigated by bidimensional laser Doppler anemometry (Part II: maximum turbulent turbulent shear stress). Int. J. Artif. Organs 20(11), 629-636 (1997).
-
(1997)
Int. J. Artif. Organs
, vol.20
, Issue.11
, pp. 629-636
-
-
Barbaro, V.1
Grigioni, M.2
Daniele, C.3
D'Avenio, G.4
Boccanera, G.5
-
24
-
-
0000796640
-
Statistical errors in measurements on random time functions
-
Davenport WB Jr, Johnson RA, Middleton D. Statistical errors in measurements on random time functions. J. Appl. Phys. 23(4), 377-388, (1952).
-
(1952)
J. Appl. Phys.
, vol.23
, Issue.4
, pp. 377-388
-
-
Davenport Jr., W.B.1
Johnson, R.A.2
Middleton, D.3
-
25
-
-
0035063176
-
The influence of the leaflets' curvature on the flow field in two bileaflet prosthetic heart valves
-
Grigioni M, Daniele C, D'Avenio G, Barbaro V. The influence of the leaflets' curvature on the flow field in two bileaflet prosthetic heart valves. J. Biomech. 34(5), 613-621 (2001).
-
(2001)
J. Biomech.
, vol.34
, Issue.5
, pp. 613-621
-
-
Grigioni, M.1
Daniele, C.2
D'Avenio, G.3
Barbaro, V.4
-
26
-
-
34249836756
-
Theory of cross-correlation analysis of PIV images
-
Keane RD, Adrian RJ. Theory of cross-correlation analysis of PIV images. Appl. Sci. Res. 49, 191-215 (1992).
-
(1992)
Appl. Sci. Res.
, vol.49
, pp. 191-215
-
-
Keane, R.D.1
Adrian, R.J.2
-
27
-
-
0032448273
-
Principal stress analysis in LDA measurements of the flow field downstream of 19 mm Sorin Bicarbon heart valve
-
Barbaro V, Grigioni M, Daniele C, D'Avenio G. Principal stress analysis in LDA measurements of the flow field downstream of 19 mm Sorin Bicarbon heart valve. Technol. Healthcare 6, 259-270 (1998).
-
(1998)
Technol. Healthcare
, vol.6
, pp. 259-270
-
-
Barbaro, V.1
Grigioni, M.2
Daniele, C.3
D'Avenio, G.4
-
28
-
-
0025213910
-
The geometry of the aortic root in health, at valve disease and after valve replacement
-
Reul H, Vahlbruch A, Giersiepen M et al. The geometry of the aortic root in health, at valve disease and after valve replacement. J. Biomech. 23, 181-191 (1990).
-
(1990)
J. Biomech.
, vol.23
, pp. 181-191
-
-
Reul, H.1
Vahlbruch, A.2
Giersiepen, M.3
-
29
-
-
3042575120
-
Critical aspects for a CFD simulation compared with PIV analysis of the flow field downstream a prosthetic heart valve
-
Arnez ZM, Brebbia CA, Solina F, Stankovski V (Eds). WIT Press, Southampton, UK
-
Grigioni M, Daniele C, Del Gaudio C et al. Critical aspects for a CFD simulation compared with PIV analysis of the flow field downstream a prosthetic heart valve. In: Simulations in Biomedicine V. Arnez ZM, Brebbia CA, Solina F, Stankovski V (Eds). WIT Press, Southampton, UK, 271-280 (2003).
-
(2003)
Simulations in Biomedicine V
, pp. 271-280
-
-
Grigioni, M.1
Daniele, C.2
Del Gaudio, C.3
-
30
-
-
2942685191
-
High-speed scanning stereoscopic PIV for 3D vorticity measurement in liquids
-
Hori T, Sakakibara J. High-speed scanning stereoscopic PIV for 3D vorticity measurement in liquids. Measurement Sci. Technol. 15(6), 1067-1078 (2004).
-
(2004)
Measurement Sci. Technol.
, vol.15
, Issue.6
, pp. 1067-1078
-
-
Hori, T.1
Sakakibara, J.2
-
31
-
-
0031386326
-
Distortion compensation for generalized stereoscopic particle image velocimetry
-
Soloff SM, Adrian RJ, Liu ZC. Distortion compensation for generalized stereoscopic particle image velocimetry. Measurement Sci. Technol. 8, 1441-1454 (1997).
-
(1997)
Measurement Sci. Technol.
, vol.8
, pp. 1441-1454
-
-
Soloff, S.M.1
Adrian, R.J.2
Liu, Z.C.3
-
32
-
-
0002887770
-
Stereoscopic particle image velocimetry applied to liquid flows
-
Prasad, AK, Adrian, RJ. Stereoscopic particle image velocimetry applied to liquid flows. Exp. Fluids 15, 49-60 (1993).
-
(1993)
Exp. Fluids
, vol.15
, pp. 49-60
-
-
Prasad, A.K.1
Adrian, R.J.2
-
33
-
-
0029360712
-
Differences in spectral composition between monostrut Bjork-Shiley and Carbomedics valves implanted in the aortic position
-
Sava H, McDonnell JTE. Differences in spectral composition between monostrut Bjork-Shiley and Carbomedics valves implanted in the aortic position. Med. Biol. Eng. Comput. 33, 689-694 (1995).
-
(1995)
Med. Biol. Eng. Comput.
, vol.33
, pp. 689-694
-
-
Sava, H.1
McDonnell, J.T.E.2
-
34
-
-
0030200538
-
Spectral composition of heart sounds before and after mechanical heart valve implantation using a modified forward-backward Prony's method
-
Sava H, McDonnell JTE. Spectral composition of heart sounds before and after mechanical heart valve implantation using a modified forward-backward Prony's method. IEEE Trans. Biomed. Eng. 43(7), 734-742 (1996).
-
(1996)
IEEE Trans. Biomed. Eng.
, vol.43
, Issue.7
, pp. 734-742
-
-
Sava, H.1
McDonnell, J.T.E.2
-
35
-
-
0036618179
-
Comparison of wavelet transform and FFT methods in the analysis of EEG signals
-
Akin M. Comparison of wavelet transform and FFT methods in the analysis of EEG signals. J. Med. Syst. 26, 241-247 (2002).
-
(2002)
J. Med. Syst.
, vol.26
, pp. 241-247
-
-
Akin, M.1
-
36
-
-
0036086918
-
Wavelet decomposition of cardiovascular signals for baroreceptor function tests in pigs
-
Wiklund U, Akay M, Morrison S, Niklasson U. Wavelet decomposition of cardiovascular signals for baroreceptor function tests in pigs. IEEE Trans. Biomed. Eng. 49, 651-661 (2002).
-
(2002)
IEEE Trans. Biomed. Eng.
, vol.49
, pp. 651-661
-
-
Wiklund, U.1
Akay, M.2
Morrison, S.3
Niklasson, U.4
-
37
-
-
0035970026
-
Wavelet entropy: A new tool for analysis of short duration brain electrical signals
-
Rosso OA, Blanco S, Yordanova J et al. Wavelet entropy: a new tool for analysis of short duration brain electrical signals. J. Neurosci. Meth. 105, 65-75 (2001).
-
(2001)
J. Neurosci. Meth.
, vol.105
, pp. 65-75
-
-
Rosso, O.A.1
Blanco, S.2
Yordanova, J.3
-
38
-
-
0036889713
-
Free emboli formation in the wake of bileaflet mechanical heart valves and the effects of implantation techniques
-
Bluestein D, Li YM, Krukenkamp IB. Free emboli formation in the wake of bileaflet mechanical heart valves and the effects of implantation techniques. J. Biomech. 35(12), 1533-1540 (2002).
-
(2002)
J. Biomech.
, vol.35
, Issue.12
, pp. 1533-1540
-
-
Bluestein, D.1
Li, Y.M.2
Krukenkamp, I.B.3
-
39
-
-
0030152652
-
A three-dimensional, time-dependent analysis of flow through a bileaflet mechanical heart valve: Comparison of experimental and numerical results
-
King MJ, Corden J, David T, Fisher J. A three-dimensional, time-dependent analysis of flow through a bileaflet mechanical heart valve: comparison of experimental and numerical results. J. Biomech. 29(5), 609-618 (1996).
-
(1996)
J. Biomech.
, vol.29
, Issue.5
, pp. 609-618
-
-
King, M.J.1
Corden, J.2
David, T.3
Fisher, J.4
-
40
-
-
0031126287
-
Three-dimensional study of the effect of two leaflet opening angles on the time-dependent flow through a bileaflet mechanical heart valve
-
King MJ, David T, Fisher J. Three-dimensional study of the effect of two leaflet opening angles on the time-dependent flow through a bileaflet mechanical heart valve. Med. Eng. Phys. 19(3), 235-241 (1997).
-
(1997)
Med. Eng. Phys.
, vol.19
, Issue.3
, pp. 235-241
-
-
King, M.J.1
David, T.2
Fisher, J.3
-
41
-
-
0033404916
-
A three-dimensional analysis of flow in the pivot regions of an ATS bileaflet valve
-
Kelly SG, Verdonck PR, Vierendeels JA et al. A three-dimensional analysis of flow in the pivot regions of an ATS bileaflet valve. Int. J. Artif. Organs 22(11), 754-763 (1999).
-
(1999)
Int. J. Artif. Organs
, vol.22
, Issue.11
, pp. 754-763
-
-
Kelly, S.G.1
Verdonck, P.R.2
Vierendeels, J.A.3
-
42
-
-
0036513893
-
Evaluation technique for bileaflet mechanical valves
-
Shipkowitz T, Ambrus J, Kurk J, Wickramasinghe K. Evaluation technique for bileaflet mechanical valves. J. Heart Valve Dis. 11(2), 275-282 (2002).
-
(2002)
J. Heart Valve Dis.
, vol.11
, Issue.2
, pp. 275-282
-
-
Shipkowitz, T.1
Ambrus, J.2
Kurk, J.3
Wickramasinghe, K.4
-
43
-
-
0032073603
-
Analysis of 3D transient blood flow passing through an artificial aortic valve by Lattice-Boltzmann methods
-
Krafczyk M, Cerrolaza M, Schulz M, Rank E. Analysis of 3D transient blood flow passing through an artificial aortic valve by Lattice-Boltzmann methods. J. Biomech. 31(5), 453-462 (1998).
-
(1998)
J. Biomech.
, vol.31
, Issue.5
, pp. 453-462
-
-
Krafczyk, M.1
Cerrolaza, M.2
Schulz, M.3
Rank, E.4
-
44
-
-
0026832985
-
Experimental and numerical analyses of the steady flow field around an aortic Bjork-Shiley standard valve prosthesis
-
Lei M, van Steenhoven AA, van Campen DH. Experimental and numerical analyses of the steady flow field around an aortic Bjork-Shiley standard valve prosthesis. J. Biomech. 25(3), 213-222 (1992).
-
(1992)
J. Biomech.
, vol.25
, Issue.3
, pp. 213-222
-
-
Lei, M.1
van Steenhoven, A.A.2
van Campen, D.H.3
-
45
-
-
0014482889
-
The fluid mechanics of the aortic valve
-
Bellhouse BJ, Talbot C. The fluid mechanics of the aortic valve. J. Fluid Mech. 35, 721-735 (1969).
-
(1969)
J. Fluid Mech.
, vol.35
, pp. 721-735
-
-
Bellhouse, B.J.1
Talbot, C.2
-
46
-
-
0018200398
-
The Bjork-Shiley aortic prosthesis: Flow characteristics, thrombus formation and tissue overgrowth
-
Yoganathan AP, Corcoran WH, Harrison EC, Carl JR. The Bjork-Shiley aortic prosthesis: flow characteristics, thrombus formation and tissue overgrowth. Circulation 58(1), 70-76 (1978).
-
(1978)
Circulation
, vol.58
, Issue.1
, pp. 70-76
-
-
Yoganathan, A.P.1
Corcoran, W.H.2
Harrison, E.C.3
Carl, J.R.4
-
47
-
-
0033213797
-
A discussion on the threshold limit for hemolysis related to Reynolds shear stress
-
Grigioni M, Daniele C, D'Avenio G, Barbaro V. A discussion on the threshold limit for hemolysis related to Reynolds shear stress. J. Biomech. 32(10), 1107-1112 (1999).
-
(1999)
J. Biomech.
, vol.32
, Issue.10
, pp. 1107-1112
-
-
Grigioni, M.1
Daniele, C.2
D'Avenio, G.3
Barbaro, V.4
-
48
-
-
2542443814
-
Particle image velocimetry for flow analysis in longitudinal planes across a mechanical artificial heart valve
-
Castellini P, Pinotti M, Scalise L. Particle image velocimetry for flow analysis in longitudinal planes across a mechanical artificial heart valve. Artif. Organs 28(5), 507-513 (2004).
-
(2004)
Artif. Organs
, vol.28
, Issue.5
, pp. 507-513
-
-
Castellini, P.1
Pinotti, M.2
Scalise, L.3
-
49
-
-
0038270078
-
Three-dimensional flow analysis of a mechanical bileaflet mitral prosthesis
-
Akutsu T, Masuda T. Three-dimensional flow analysis of a mechanical bileaflet mitral prosthesis. J. Artif. Organs 6(2), 112-123 (2003).
-
(2003)
J. Artif. Organs
, vol.6
, Issue.2
, pp. 112-123
-
-
Akutsu, T.1
Masuda, T.2
-
50
-
-
0043236252
-
Regurgitant flow field characteristics of the St. Jude bileaflet mechanical heart valve under physiologic pulsatile flow using particle image velocimetry
-
Manning KB, Kini V, Fontaine AA, Deutsch S, Tarbell JM. Regurgitant flow field characteristics of the St. Jude bileaflet mechanical heart valve under physiologic pulsatile flow using particle image velocimetry. Artif. Organs 27(9), 840-846 (2003).
-
(2003)
Artif. Organs
, vol.27
, Issue.9
, pp. 840-846
-
-
Manning, K.B.1
Kini, V.2
Fontaine, A.A.3
Deutsch, S.4
Tarbell, J.M.5
-
51
-
-
0035117322
-
Integrating particle image velocimetry and laser Doppler velocimetry measurements of the regurgitant flow field past mechanical heart valves
-
Kini V, Bachmann C, Fontaine A, Deutsch S, Tarbell JM. Integrating particle image velocimetry and laser Doppler velocimetry measurements of the regurgitant flow field past mechanical heart valves. Artif. Organs 25(2), 136-145 (2001).
-
(2001)
Artif. Organs
, vol.25
, Issue.2
, pp. 136-145
-
-
Kini, V.1
Bachmann, C.2
Fontaine, A.3
Deutsch, S.4
Tarbell, J.M.5
-
52
-
-
0034791973
-
Pulsatile flow studies of a porcine bioprosthetic aortic valve in vitro: PIV measurements and shear-induced blood damage
-
Lim WL, Chew YT, Chew TC, Low HT. Pulsatile flow studies of a porcine bioprosthetic aortic valve in vitro: PIV measurements and shear-induced blood damage. J. Biomech. 34(11), 1417-1427 (2001).
-
(2001)
J. Biomech.
, vol.34
, Issue.11
, pp. 1417-1427
-
-
Lim, W.L.1
Chew, Y.T.2
Chew, T.C.3
Low, H.T.4
-
53
-
-
0035086821
-
Digital particle image velocimetry investigation of the pulsating flow around a simplified 2D model of a bileaflet heart valve
-
Zhao JB, Shi YB, Yeo TJ, Hwang NH. Digital particle image velocimetry investigation of the pulsating flow around a simplified 2D model of a bileaflet heart valve. J. Heart Valve Dis. 10(2), 239-253 (2001).
-
(2001)
J. Heart Valve Dis.
, vol.10
, Issue.2
, pp. 239-253
-
-
Zhao, J.B.1
Shi, Y.B.2
Yeo, T.J.3
Hwang, N.H.4
-
54
-
-
0034329720
-
Comparison of particle image velocimetry and laser Doppler anemometry measurements in turbulent fluid flow
-
Wernet MP, Subramanian A, Mu H, Kadambi JR. Comparison of particle image velocimetry and laser Doppler anemometry measurements in turbulent fluid flow. Ann. Biomed. Eng. 28(11), 1393-1396 (2000).
-
(2000)
Ann. Biomed. Eng.
, vol.28
, Issue.11
, pp. 1393-1396
-
-
Wernet, M.P.1
Subramanian, A.2
Mu, H.3
Kadambi, J.R.4
-
55
-
-
0033621716
-
Experimental investigation of the steady flow downstream of the St. Jude bileaflet heart valve: A comparison between laser Doppler velocimetry and particle image velocimetry techniques
-
Browne P, Ramuzat A, Saxena R, Yoganathan AP. Experimental investigation of the steady flow downstream of the St. Jude bileaflet heart valve: a comparison between laser Doppler velocimetry and particle image velocimetry techniques. Ann. Biomed. Eng. 28(1), 39-47 (2000).
-
(2000)
Ann. Biomed. Eng.
, vol.28
, Issue.1
, pp. 39-47
-
-
Browne, P.1
Ramuzat, A.2
Saxena, R.3
Yoganathan, A.P.4
-
56
-
-
0033623709
-
Flow visualization in mechanical heart valves: Occluder rebound and cavitation potential
-
Kini V, Bachmann C, Fontaine A, Deutsch S, Tarbell JM. Flow visualization in mechanical heart valves: occluder rebound and cavitation potential. Ann. Biomed. Eng. 28(4), 431-441 (2000).
-
(2000)
Ann. Biomed. Eng.
, vol.28
, Issue.4
, pp. 431-441
-
-
Kini, V.1
Bachmann, C.2
Fontaine, A.3
Deutsch, S.4
Tarbell, J.M.5
-
57
-
-
0033774274
-
Particle image velocimetry investigation of intravalvular flow fields of a bileaflet mechanical heart valve in a pulsatile flow
-
Subramanian A, Mu H, Kadambi JR et al. Particle image velocimetry investigation of intravalvular flow fields of a bileaflet mechanical heart valve in a pulsatile flow. J. Heart Valve Dis. 9(5), 721-731 (2000).
-
(2000)
J. Heart Valve Dis.
, vol.9
, Issue.5
, pp. 721-731
-
-
Subramanian, A.1
Mu, H.2
Kadambi, J.R.3
-
58
-
-
0034177656
-
Vortex shedding as a mechanism for free emboli formation in mechanical heart valves
-
Bluestein D, Rambod E, Gharib M. Vortex shedding as a mechanism for free emboli formation in mechanical heart valves. J. Biomech. Eng. 122(2), 125-134 (2000).
-
(2000)
J. Biomech. Eng.
, vol.122
, Issue.2
, pp. 125-134
-
-
Bluestein, D.1
Rambod, E.2
Gharib, M.3
-
59
-
-
0032072741
-
Steady flow dynamics of prosthetic aortic heart valves: A comparative evaluation with PIV techniques
-
Lim WL, Chew YT, Chew TC, Low HT. Steady flow dynamics of prosthetic aortic heart valves: a comparative evaluation with PIV techniques. J. Biomech. 31(5), 411-421 (1998).
-
(1998)
J. Biomech.
, vol.31
, Issue.5
, pp. 411-421
-
-
Lim, W.L.1
Chew, Y.T.2
Chew, T.C.3
Low, H.T.4
-
60
-
-
0031029322
-
Steady flow velocity field and turbulent stress mappings downstream of a porcine bioprosthetic aortic valve in vitro
-
Lim WL, Chew YT, Chew TC, Low HT. Steady flow velocity field and turbulent stress mappings downstream of a porcine bioprosthetic aortic valve in vitro. Ann. Biomed. Eng. 25(1), 86-95 (1997).
-
(1997)
Ann. Biomed. Eng.
, vol.25
, Issue.1
, pp. 86-95
-
-
Lim, W.L.1
Chew, Y.T.2
Chew, T.C.3
Low, H.T.4
-
61
-
-
0029944404
-
Digital particle image velocimetry (DPIV) measurements of the velocity profiles through bileaflet mechanical valves: In vitro steady
-
Shandas R, Kwon J. Digital particle image velocimetry (DPIV) measurements of the velocity profiles through bileaflet mechanical valves: in vitro steady. Biomed. Sci. Instrum. 32, 161-167 (1996).
-
(1996)
Biomed. Sci. Instrum.
, vol.32
, pp. 161-167
-
-
Shandas, R.1
Kwon, J.2
-
62
-
-
0027991718
-
Particle image velocimetry in the investigation of flow past artificial heart valves
-
Lim WL, Chew YT, Chew TC, Low HT. Particle image velocimetry in the investigation of flow past artificial heart valves. Ann. Biomed. Eng. 22(3), 307-318 (1994).
-
(1994)
Ann. Biomed. Eng.
, vol.22
, Issue.3
, pp. 307-318
-
-
Lim, W.L.1
Chew, Y.T.2
Chew, T.C.3
Low, H.T.4
-
63
-
-
0027699959
-
Phonocardiogram signal analysis: Techniques and performance comparison
-
Obaidat MS. Phonocardiogram signal analysis: techniques and performance comparison. J. Med. Eng. Tech. 17(6), 221-227 (1993).
-
(1993)
J. Med. Eng. Tech.
, vol.17
, Issue.6
, pp. 221-227
-
-
Obaidat, M.S.1
|