메뉴 건너뛰기




Volumn 19, Issue 3, 1997, Pages 235-241

Three-dimensional study of the effect of two leaflet opening angles on the time-dependent flow through a bileaflet mechanical heart valve

Author keywords

CarboMedics; CFD; Computational fluid dynamics; Heart valve; Model; Numerical; St. Jude; Three dimensional; Time dependent

Indexed keywords

CARDIOVASCULAR SYSTEM; COMPUTATIONAL FLUID DYNAMICS; LAMINAR FLOW; MATHEMATICAL MODELS; NEWTONIAN FLOW; NEWTONIAN LIQUIDS; REYNOLDS NUMBER; VORTEX FLOW; WAKES;

EID: 0031126287     PISSN: 13504533     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1350-4533(96)00066-5     Document Type: Article
Times cited : (46)

References (13)
  • 1
    • 0025264309 scopus 로고
    • A new theoretical model for the non invasive quantitative of mitral regurgitation
    • Cape, e. G., Yoganathan, A. P. and Levine, R. A., A new theoretical model for the non invasive quantitative of mitral regurgitation. Journal of Biomechanics, 1990, 23, 27-331.
    • (1990) Journal of Biomechanics , vol.23 , pp. 27-331
    • Cape, E.G.1    Yoganathan, A.P.2    Levine, R.A.3
  • 2
    • 0028533807 scopus 로고
    • A squeeze flow phenomenon at the closing of a bileaflet mechanical heart valve prosthesis
    • Bluestein, D., Einav, S. and Hwang, N. H., A squeeze flow phenomenon at the closing of a bileaflet mechanical heart valve prosthesis. Journal of Biomechanics, 1994, 27, 1369-1378.
    • (1994) Journal of Biomechanics , vol.27 , pp. 1369-1378
    • Bluestein, D.1    Einav, S.2    Hwang, N.H.3
  • 3
    • 0022383294 scopus 로고
    • Pulsatile flow past a St. Jude Medical bileaflet heart valve
    • Chandran, K. B., Pulsatile flow past a St. Jude Medical bileaflet heart valve. Journal of Thoracic and Cardiovascular Surgery, 1985, 89, 743-749.
    • (1985) Journal of Thoracic and Cardiovascular Surgery , vol.89 , pp. 743-749
    • Chandran, K.B.1
  • 6
    • 0024761866 scopus 로고
    • An in vitro study of the St. Jude Medical and Edwards Duromedics bileaflet valve using laser anemometry
    • Fatermi, R. S. and Chandran, K. B., An in vitro study of the St. Jude Medical and Edwards Duromedics bileaflet valve using laser anemometry. Journal of Biomechanical Engineering, 1989, 111, 298-302.
    • (1989) Journal of Biomechanical Engineering , vol.111 , pp. 298-302
    • Fatermi, R.S.1    Chandran, K.B.2
  • 7
    • 0007255607 scopus 로고
    • Computer-assisted design of butterfly bileaflet mechanical heart valves for the mitral position
    • McQueen, D. M. and Peskin, C., Computer-assisted design of butterfly bileaflet mechanical heart valves for the mitral position. Journal of Computational Fluids, 1985, 82, 289-297.
    • (1985) Journal of Computational Fluids , vol.82 , pp. 289-297
    • McQueen, D.M.1    Peskin, C.2
  • 8
    • 0026832985 scopus 로고
    • Experimental and numerical analyses of the steady flow field around an aortic Bjork-Shiley standard valve prostheses
    • Lei, M., Van Steenhoven, A. A. and Van Campen, D. H., Experimental and numerical analyses of the steady flow field around an aortic Bjork-Shiley standard valve prostheses. Journal of Biomechanics, 1991, 3, 213-222.
    • (1991) Journal of Biomechanics , vol.3 , pp. 213-222
    • Lei, M.1    Van Steenhoven, A.2    Van Campen, D.H.3
  • 11
    • 0030152652 scopus 로고    scopus 로고
    • Three dimensional, time dependent analysis of flow through bileaflet mechanical heart valves. Comparison of experimental and numerical results
    • King, M. J., Corden, J., David, T. and Fisher, J. A., Three dimensional, time dependent analysis of flow through bileaflet mechanical heart valves. Comparison of experimental and numerical results. Journal of Biomechanics, 1996, 29, 609-618.
    • (1996) Journal of Biomechanics , vol.29 , pp. 609-618
    • King, M.J.1    Corden, J.2    David, T.3    Fisher, J.A.4
  • 12
    • 0025661079 scopus 로고
    • Stability and the existence of multiple solutions for viscous flow in suddenly enlarged channels
    • Shapira, M. and Degani, D., Stability and the existence of multiple solutions for viscous flow in suddenly enlarged channels. Computational Fluids, 1990, 18, 239-258.
    • (1990) Computational Fluids , vol.18 , pp. 239-258
    • Shapira, M.1    Degani, D.2
  • 13
    • 0028671640 scopus 로고
    • An initial parametric design study on fluid flow through bileaflet mechanical heart valves using computational fluid dynamics
    • King, M. J., David, T. and Fisher, J., An initial parametric design study on fluid flow through bileaflet mechanical heart valves using computational fluid dynamics. Journal of Engineering in Medicine, 1994, 208, 63-71.
    • (1994) Journal of Engineering in Medicine , vol.208 , pp. 63-71
    • King, M.J.1    David, T.2    Fisher, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.