Three-dimensional flow analysis of a mechanical bileaflet mitral prosthesis

Author keywords

Biofluid mechanics; Flow visualization; Medical equipment; PIV; Prosthetic heart valve; PTV

Indexed keywords

ARTICLE; DEVICE; FLOW KINETICS; FLUID TRANSPORT; HEART CYCLE; HEART VALVE PROSTHESIS; HEART VALVE REPLACEMENT; HEMODYNAMICS; IMAGE ANALYSIS; MEASUREMENT; MEDICAL INSTRUMENTATION; MITRAL VALVE PROSTHESIS; PRIORITY JOURNAL; VELOCITY;

EID: 0038270078     PISSN: 14347229     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10047-003-0214-z     Document Type: Article
Times cited : (21)

References (13)
  • 2
    • 0001647455 scopus 로고
    • Aortic replacement clinical experience with a semirigid ball-valve prosthesis
    • Starr A, Edwards ML, McCord CW, Griswold HE. Aortic replacement clinical experience with a semirigid ball-valve prosthesis. Circulation 1963;27:779-783
    • (1963) Circulation , vol.27 , pp. 779-783
    • Starr, A.1    Edwards, M.L.2    McCord, C.W.3    Griswold, H.E.4
  • 4
    • 0021893658 scopus 로고
    • A 5.5-year experience with the St. Jude medical cardiac valve prosthesis: Early and late results of 737 valve replacements in 671 patients
    • Baudet EM, Oca CC, Roques XF, Laborde MN, Hafez AS, Collot MA, Ghidoni IM. A 5.5-year experience with the St. Jude medical cardiac valve prosthesis: early and late results of 737 valve replacements in 671 patients. J Thorac Cardiovasc Surg 1985;90:137-144
    • (1985) J Thorac Cardiovasc Surg , vol.90 , pp. 137-144
    • Baudet, E.M.1    Oca, C.C.2    Roques, X.F.3    Laborde, M.N.4    Hafez, A.S.5    Collot, M.A.6    Ghidoni, I.M.7
  • 6
    • 0003030831 scopus 로고    scopus 로고
    • Effect of mechanical prosthetic heart valve orientation on the flow field inside the simulated ventricle: Comparison between St. Jude medical valve and Medtronic-Hall valve
    • Akutsu T, Higuchi D. Effect of mechanical prosthetic heart valve orientation on the flow field inside the simulated ventricle: comparison between St. Jude medical valve and Medtronic-Hall valve. J Artif Organs 1999;2:39-45
    • (1999) J Artif Organs , vol.2 , pp. 39-45
    • Akutsu, T.1    Higuchi, D.2
  • 7
    • 0034537912 scopus 로고    scopus 로고
    • Effect of the mechanical prosthetic mono-and bi-leaflet heart valve orientation on the flow field inside the simulated ventricle
    • Akutsu T, Higuchi D. Effect of the mechanical prosthetic mono-and bi-leaflet heart valve orientation on the flow field inside the simulated ventricle. J Artif Organs 2000;3:126-135
    • (2000) J Artif Organs , vol.3 , pp. 126-135
    • Akutsu, T.1    Higuchi, D.2
  • 8
    • 0034936076 scopus 로고    scopus 로고
    • Flow analysis of bileaflet mechanical prosthetic heart valves using a laser Doppler anemometer: Effect of the valve designs and installed orientations to the flow inside the simulated left ventricle
    • Akutsu T, Higuchi D. Flow analysis of bileaflet mechanical prosthetic heart valves using a laser Doppler anemometer: effect of the valve designs and installed orientations to the flow inside the simulated left ventricle. J Artif Organs 2001;4:113-125
    • (2001) J Artif Organs , vol.4 , pp. 113-125
    • Akutsu, T.1    Higuchi, D.2
  • 10
    • 0000666614 scopus 로고
    • Unsteady fluid dynamics of three contemporary heart valves using a two-component LDA system
    • Modi VJ, Bishop WF, Akutsu T. Unsteady fluid dynamics of three contemporary heart valves using a two-component LDA system. Artif Organs 1991;14:103-107
    • (1991) Artif Organs , vol.14 , pp. 103-107
    • Modi, V.J.1    Bishop, W.F.2    Akutsu, T.3
  • 11
    • 0030873780 scopus 로고    scopus 로고
    • Unsteady fluid dynamics of several mechanical prosthetic heart valves using a two-component laser Doppler anemometer system
    • Akutsu T, Modi VJ. Unsteady fluid dynamics of several mechanical prosthetic heart valves using a two-component laser Doppler anemometer system. Artif Organs 1997;21:1110-1120
    • (1997) Artif Organs , vol.21 , pp. 1110-1120
    • Akutsu, T.1    Modi, V.J.2
  • 12
    • 0000599447 scopus 로고
    • The anatomy of the mitral valve and its associated structures
    • Du Plessis LA, Marchand P. The anatomy of the mitral valve and its associated structures. Thorax 1964;19:221-227
    • (1964) Thorax , vol.19 , pp. 221-227
    • Du Plessis, L.A.1    Marchand, P.2
  • 13
    • 0015147582 scopus 로고
    • An artificial arterial system for pumping hearts
    • Westerhof N, Elzinga G, Sipkema P. An artificial arterial system for pumping Hearts. J Appl Physiol 1971;31:776-781
    • (1971) J Appl Physiol , vol.31 , pp. 776-781
    • Westerhof, N.1    Elzinga, G.2    Sipkema, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.