메뉴 건너뛰기




Volumn 32, Issue , 1996, Pages 161-164

Digital Particle Image Velocimetry (DPIV) measurements of the velocity profiles through bileaflet mechanical valves: In vitro steady flow studies

Author keywords

Bileaflet Mechanical Cardiac Valves; Digital Particle Image Velocimetry; Flow Dynamics

Indexed keywords

CARDIOLOGY; COMPUTATIONAL METHODS; FLUID DYNAMICS; HEMODYNAMICS; IMPLANTS (SURGICAL); LASER DOPPLER VELOCIMETERS; MATHEMATICAL MODELS; REYNOLDS NUMBER; VELOCITY;

EID: 0029944404     PISSN: 00678856     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (8)

References (5)
  • 1
    • 0020970223 scopus 로고
    • Laser anemometry measurements of pulsatile flow past aortic valve prosthesis
    • Chandran KB, Cabell GN, Khalighi B, Chen CJ: Laser anemometry measurements of pulsatile flow past aortic valve prosthesis. J. Biomechanics 1983; 16:865-873.
    • (1983) J. Biomechanics , vol.16 , pp. 865-873
    • Chandran, K.B.1    Cabell, G.N.2    Khalighi, B.3    Chen, C.J.4
  • 2
    • 0022592273 scopus 로고
    • In vitro pulsatile flow velocity and shear stress measurements in the vicinity of mechanical mitral heart valve prostheses
    • Woo YR, Yoganathan AP: In vitro pulsatile flow velocity and shear stress measurements in the vicinity of mechanical mitral heart valve prostheses. J. Biomechanics 1986; 19:39-51.
    • (1986) J. Biomechanics , vol.19 , pp. 39-51
    • Woo, Y.R.1    Yoganathan, A.P.2
  • 3
    • 0027641911 scopus 로고
    • Laser anemometry measurements of steady flow past aortic valve prostheses
    • Chew YT, Low HT, Lee CN, Kwa SS: Laser anemometry measurements of steady flow past aortic valve prostheses. J. Biomech. Eng. 1993;115:290-298.
    • (1993) J. Biomech. Eng. , vol.115 , pp. 290-298
    • Chew, Y.T.1    Low, H.T.2    Lee, C.N.3    Kwa, S.S.4
  • 4
    • 0028853909 scopus 로고
    • Pressure recovery in bileaflet heart valve prostheses: Localized high velocities and gradients in central and side orifices with implications for Doppler-catheter gradient relation in aortic and mitral position
    • Vandervoort PM, Greenberg NL, Pu M, Powerl KA, Cosgrove DM, Thomas JD: Pressure recovery in bileaflet heart valve prostheses: Localized high velocities and gradients in central and side orifices with implications for Doppler-catheter gradient relation in aortic and mitral position. Circulation 1995;92:3464-3472.
    • (1995) Circulation , vol.92 , pp. 3464-3472
    • Vandervoort, P.M.1    Greenberg, N.L.2    Pu, M.3    Powerl, K.A.4    Cosgrove, D.M.5    Thomas, J.D.6
  • 5
    • 0028951039 scopus 로고
    • The Nature of Flow Acceleration into a Finite Sized Orifice: Steady and Pulsatile Flow Studies on the Flow Convergence Region using Simultaneous Ultrasound Doppler Flow Mapping and Laser Doppler Velocimetry
    • Shandas R, Gharib M, Sahn DJ: The Nature of Flow Acceleration into a Finite Sized Orifice: Steady and Pulsatile Flow Studies on the Flow Convergence Region using Simultaneous Ultrasound Doppler Flow Mapping and Laser Doppler Velocimetry, J Am Coll Cardiology, 1995;25:1199-212.
    • (1995) J Am Coll Cardiology , vol.25 , pp. 1199-1212
    • Shandas, R.1    Gharib, M.2    Sahn, D.J.3