메뉴 건너뛰기




Volumn 108, Issue 5-6, 2004, Pages 542-548

Teleradiology system accessible through a common web browser;Sistema di teleradiologia consultabile mediante un comune browser internet

Author keywords

Internet; Teleconsulting; Teleradiology

Indexed keywords

ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER INTERFACE; COMPUTER NETWORK; COMPUTER PROGRAM; CONSULTATION; DEDICATED WEBSITE; DICOM STANDARD; DIGITAL RADIOGRAPHY; ECHOGRAPHY; IMAGE COMPRESSION; IMAGE PROCESSING; IMAGE QUALITY; IMAGE TRANSFER; IMAGING SYSTEM; INTERNET; MICROCOMPUTER; NUCLEAR MAGNETIC RESONANCE IMAGING; RADIOLOGY; TELECOMMUNICATION; TELECONSULTATION; TRANSMISSION CONTROL PROTOCOL INTERNET PROTOCOL;

EID: 13244292438     PISSN: 00338362     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (7)

References (12)
  • 1
    • 0030176156 scopus 로고    scopus 로고
    • Teleradiology: State of the art in clinical environment
    • Caramella D: Teleradiology: state of the art in clinical environment. Eur J Radiol 22: 197-204, 1996.
    • (1996) Eur J Radiol , vol.22 , pp. 197-204
    • Caramella, D.1
  • 3
    • 0031882994 scopus 로고    scopus 로고
    • Wavelet compression of medical images
    • Erickson BJ, Manduca A, Palisson P et al: Wavelet compression of medical images. Radiology 206: 599-607, 1998.
    • (1998) Radiology , vol.206 , pp. 599-607
    • Erickson, B.J.1    Manduca, A.2    Palisson, P.3
  • 4
    • 0041842457 scopus 로고    scopus 로고
    • Irreversible JPEG compression of digital chest radiographs for primary interpretation: Assessment of visually lossless threshold
    • Slone RM, Muka E, Pilgram TK: Irreversible JPEG compression of digital chest radiographs for primary interpretation: assessment of visually lossless threshold. Radiology 228: 425-429, 2003.
    • (2003) Radiology , vol.228 , pp. 425-429
    • Slone, R.M.1    Muka, E.2    Pilgram, T.K.3
  • 5
    • 0031883646 scopus 로고    scopus 로고
    • Detection of subtle abnormalities on chest radiographs after irreversible compression
    • Savcenko V, Erickson BJ, Palisson PM et al: Detection of subtle abnormalities on chest radiographs after irreversible compression. Radiology 206: 609-616, 1998.
    • (1998) Radiology , vol.206 , pp. 609-616
    • Savcenko, V.1    Erickson, B.J.2    Palisson, P.M.3
  • 6
    • 0028008897 scopus 로고
    • Thoracic CT images: Effect of lossy image compression on diagnostic accuracy
    • Cosman PC, Davidson HC, Bergin CJ et al: Thoracic CT images: effect of lossy image compression on diagnostic accuracy. Radiology 190: 517-524, 1994.
    • (1994) Radiology , vol.190 , pp. 517-524
    • Cosman, P.C.1    Davidson, H.C.2    Bergin, C.J.3
  • 7
    • 0033677356 scopus 로고    scopus 로고
    • Evaluation of JPEG and wavelet compression of body CT images for direct digital teleradiologic transmission
    • Kalyanpur A, Neklesa VP, Taylor CR et al: Evaluation of JPEG and wavelet compression of body CT images for direct digital teleradiologic transmission. Radiology 217: 772-779, 2000.
    • (2000) Radiology , vol.217 , pp. 772-779
    • Kalyanpur, A.1    Neklesa, V.P.2    Taylor, C.R.3
  • 8
    • 0031021235 scopus 로고    scopus 로고
    • Focal hepatic lesions: Effect of three-dimensional wavelet compression on detection at CT
    • Goldberg MA, Gazelle GS, Boland GW et al: Focal hepatic lesions: effect of three-dimensional wavelet compression on detection at CT. Radiology 202: 159-165, 1997.
    • (1997) Radiology , vol.202 , pp. 159-165
    • Goldberg, M.A.1    Gazelle, G.S.2    Boland, G.W.3
  • 9
    • 0037700168 scopus 로고    scopus 로고
    • Wavelet compression of low-dose chest CT data: Effect on lung nodule detection
    • Ko JP, Rusinek H, Naidich DP et al: Wavelet compression of low-dose chest CT data: effect on lung nodule detection. Radiology 228: 70-75, 2003.
    • (2003) Radiology , vol.228 , pp. 70-75
    • Ko, J.P.1    Rusinek, H.2    Naidich, D.P.3
  • 10
    • 0037381406 scopus 로고    scopus 로고
    • Acute cerebral infarction: Effect of JPEG compression on detection at CT
    • Ohgiya Y, Gokan T, Nobusawa H et al: Acute cerebral infarction: effect of JPEG compression on detection at CT. Radiology 227: 124-127, 2003.
    • (2003) Radiology , vol.227 , pp. 124-127
    • Ohgiya, Y.1    Gokan, T.2    Nobusawa, H.3
  • 11
    • 0031884062 scopus 로고    scopus 로고
    • Influence of CT image size and format on accuracy of lung nodule detection
    • Seltzer SE, Judy PF, Feldman U et al: Influence of CT image size and format on accuracy of lung nodule detection. Radiology 206: 617-622, 1998.
    • (1998) Radiology , vol.206 , pp. 617-622
    • Seltzer, S.E.1    Judy, P.F.2    Feldman, U.3
  • 12
    • 0034912642 scopus 로고    scopus 로고
    • Computer network security for the radiology enterprise
    • Eng J: Computer network security for the radiology enterprise. Radiology 220: 303-309, 2001.
    • (2001) Radiology , vol.220 , pp. 303-309
    • Eng, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.