메뉴 건너뛰기




Volumn 20, Issue 9, 2005, Pages 1780-1787

A separation-free amperometric immunosensor for vitellogenin based on screen-printed carbon arrays modified with a conductive polymer

Author keywords

Amperometric immunosensor; Conducting polymer; Enzyme label; Mediatorless system; Screen printed carbon arrays; Vitellogenin

Indexed keywords

CARBON; CYCLIC VOLTAMMETRY; ENZYMES; GLUCOSE; IMMUNOSENSORS; MONOCLONAL ANTIBODIES; QUARTZ;

EID: 12844250780     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.bios.2004.07.006     Document Type: Article
Times cited : (60)

References (26)
  • 2
    • 0033568234 scopus 로고    scopus 로고
    • An indirect perfluorosulfonated ionomer-coated electrochemical immunosensor for the detection of the protein human chorionic gonadotrophin
    • A.F. Chetcuti, and D.K.Y. Wong An indirect perfluorosulfonated ionomer-coated electrochemical immunosensor for the detection of the protein human chorionic gonadotrophin Anal. Chem. 71 1999 4088 4094
    • (1999) Anal. Chem. , vol.71 , pp. 4088-4094
    • Chetcuti, A.F.1    Wong, D.K.Y.2
  • 3
    • 0037402508 scopus 로고    scopus 로고
    • Disposable amperometric immunosensor system for rabbit IgG using conducting polymer coated screen-printed electrode
    • F. Darain, S.-U. Park, and Y.-B. Shim Disposable amperometric immunosensor system for rabbit IgG using conducting polymer coated screen-printed electrode Biosens. Bioelectron. 18 2003 773 780
    • (2003) Biosens. Bioelectron. , vol.18 , pp. 773-780
    • Darain, F.1    Park, S.-U.2    Shim, Y.-B.3
  • 4
    • 1642280987 scopus 로고    scopus 로고
    • Development of an immunosensor for the detection of vitellogenin using impedance spectroscopy
    • F. Darain, D. Park, J.-S. Park, and Y.-B. Shim Development of an immunosensor for the detection of vitellogenin using impedance spectroscopy Biosens. Bioelectron. 19 2004 1245 1252
    • (2004) Biosens. Bioelectron. , vol.19 , pp. 1245-1252
    • Darain, F.1    Park, D.2    Park, J.-S.3    Shim, Y.-B.4
  • 5
    • 0030056929 scopus 로고    scopus 로고
    • A one-step, separation-free amperometric enzyme immunosensor
    • D. Ivnitski, and J. Rishpon A one-step, separation-free amperometric enzyme immunosensor Biosens. Bioelectron. 11 1996 409 417
    • (1996) Biosens. Bioelectron. , vol.11 , pp. 409-417
    • Ivnitski, D.1    Rishpon, J.2
  • 6
    • 0242469041 scopus 로고    scopus 로고
    • Preparation of poly(thionine) modified screen-printed carbon electrode and its application to determine NADH in flow injection analysis system
    • Q. Gao, X. Cui, F. Yang, Y. Ma, and X. Yang Preparation of poly(thionine) modified screen-printed carbon electrode and its application to determine NADH in flow injection analysis system Biosens. Bioelectron. 30 2003 277 282
    • (2003) Biosens. Bioelectron. , vol.30 , pp. 277-282
    • Gao, Q.1    Cui, X.2    Yang, F.3    Ma, Y.4    Yang, X.5
  • 8
    • 0031910714 scopus 로고    scopus 로고
    • Immunosensors: Electrochemical sensing and other engineering approaches
    • A.L. Ghindilis, P. Atanasov, M. Wilkins, and E. Wilkins Immunosensors: electrochemical sensing and other engineering approaches Biosens. Bioelectron. 13 1998 113 131
    • (1998) Biosens. Bioelectron. , vol.13 , pp. 113-131
    • Ghindilis, A.L.1    Atanasov, P.2    Wilkins, M.3    Wilkins, E.4
  • 10
    • 0003448569 scopus 로고
    • Cold Spring Harbor Laboratory, USA (printed), Cold Spring Harbor, New York.
    • Harlow, E., Lane, D., 1988. Antibodies: A Laboratory Manual. Cold Spring Harbor Laboratory, USA (printed), Cold Spring Harbor, New York.
    • (1988) Antibodies: A Laboratory Manual
    • Harlow, E.1    Lane, D.2
  • 11
    • 0031080914 scopus 로고    scopus 로고
    • Recent developments in the design and application of screen-printed electrochemical sensors for biomedical, environmental and industrial analyses
    • J.P. Hart, and S.A. Wring Recent developments in the design and application of screen-printed electrochemical sensors for biomedical, environmental and industrial analyses Trend. Anal. Chem. 16 1997 89 103
    • (1997) Trend. Anal. Chem. , vol.16 , pp. 89-103
    • Hart, J.P.1    Wring, S.A.2
  • 12
    • 0022136989 scopus 로고
    • Strategies for electrochemical immunoassay
    • W.R. Heineman, and H.B. Halsall Strategies for electrochemical immunoassay Anal. Chem. 57 1985 1321A 1331A
    • (1985) Anal. Chem. , vol.57
    • Heineman, W.R.1    Halsall, H.B.2
  • 14
    • 0034089448 scopus 로고    scopus 로고
    • Separation-free electrochemical immunosensor strategies
    • A.J. Killard, and M.R. Smyth Separation-free electrochemical immunosensor strategies Anal. Lett. 33 2000 1451 1465
    • (2000) Anal. Lett. , vol.33 , pp. 1451-1465
    • Killard, A.J.1    Smyth, M.R.2
  • 15
    • 0242469044 scopus 로고    scopus 로고
    • Direct electrochemistry of horseradish peroxidase bonded on a conducting polymer modified glassy carbon electrode
    • Y.-T. Kong, M. Boopathi, and Y.-B. Shim Direct electrochemistry of horseradish peroxidase bonded on a conducting polymer modified glassy carbon electrode Biosens. Bioelectron. 19 2003 227 232
    • (2003) Biosens. Bioelectron. , vol.19 , pp. 227-232
    • Kong, Y.-T.1    Boopathi, M.2    Shim, Y.-B.3
  • 16
    • 0035891257 scopus 로고    scopus 로고
    • Direct DNA hybridization detection based on the oligonucleotide- functionalized conducting polymer
    • Y.T. Lee, and Y.B. Shim Direct DNA hybridization detection based on the oligonucleotide-functionalized conducting polymer Anal. Chem. 73 22 2001 5629 5632
    • (2001) Anal. Chem. , vol.73 , Issue.22 , pp. 5629-5632
    • Lee, Y.T.1    Shim, Y.B.2
  • 17
    • 0037185285 scopus 로고    scopus 로고
    • Simple preparation of therthiophene-3'-carboxylic acid and characterization of its polymer
    • Y.T. Lee, Y.-B. Shim, and S.C. Shin Simple preparation of therthiophene-3'-carboxylic acid and characterization of its polymer Syn. Met. 126 2002 105 110
    • (2002) Syn. Met. , vol.126 , pp. 105-110
    • Lee, Y.T.1    Shim, Y.-B.2    Shin, S.C.3
  • 20
    • 0346789278 scopus 로고    scopus 로고
    • Advances in electrochemical immunosensors
    • P. Skladal Advances in electrochemical immunosensors Electroanalysis 9 1997 737 745
    • (1997) Electroanalysis , vol.9 , pp. 737-745
    • Skladal, P.1
  • 21
    • 0034802143 scopus 로고    scopus 로고
    • Analysis of the estrogenic activity of sewage treatment works and receiving waters using vitellogein induction in fish as a biomarker
    • M. Solé, C. Porte, and D. Barcelo Analysis of the estrogenic activity of sewage treatment works and receiving waters using vitellogein induction in fish as a biomarker Trend. Anal. Chem. 20 2001 518 525
    • (2001) Trend. Anal. Chem. , vol.20 , pp. 518-525
    • Solé, M.1    Porte, C.2    Barcelo, D.3
  • 22
    • 0028840615 scopus 로고
    • Vitellogensis a biomarker for estrogenic contamination of the aquatic environment
    • J.P. Sumpter, and S. Jobting Vitellogensis a biomarker for estrogenic contamination of the aquatic environment Environ. Health Perspect. 103 1995 173 178
    • (1995) Environ. Health Perspect. , vol.103 , pp. 173-178
    • Sumpter, J.P.1    Jobting, S.2
  • 25
    • 0042706515 scopus 로고    scopus 로고
    • A highly sensitive flow-through amperometric immunosensor based on the peroxidase chip and enzyme- channelling principle
    • J. Zeravik, T. Ruzgas, and M. Franek A highly sensitive flow-through amperometric immunosensor based on the peroxidase chip and enzyme- channelling principle Biosens. Bioelectron. 18 2003 1321 1327
    • (2003) Biosens. Bioelectron. , vol.18 , pp. 1321-1327
    • Zeravik, J.1    Ruzgas, T.2    Franek, M.3
  • 26
    • 0034253312 scopus 로고    scopus 로고
    • Materials and techniques for electrochemical biosensor design and construction
    • S. Zhang, G. Wright, and Y. Yang Materials and techniques for electrochemical biosensor design and construction Biosens. Bioelectron. 15 2000 273 282
    • (2000) Biosens. Bioelectron. , vol.15 , pp. 273-282
    • Zhang, S.1    Wright, G.2    Yang, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.