메뉴 건너뛰기




Volumn 19, Issue 3, 2003, Pages 227-232

Direct electrochemistry of horseradish peroxidase bonded on a conducting polymer modified glassy carbon electrode

Author keywords

Amperometric biosensor; Conducting polymer; Direct electrochemistry of HRP; Horseradish peroxidase

Indexed keywords

BONDING; CARBON; CARBOXYLIC ACIDS; CATALYSIS; CONDUCTIVE PLASTICS; ELECTROCHEMICAL ELECTRODES; ELECTROCHEMISTRY; ELECTRON TRANSITIONS; GLASS; PLASTIC FILMS; REDOX REACTIONS; REDUCTION;

EID: 0242469044     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0956-5663(03)00216-1     Document Type: Article
Times cited : (164)

References (26)
  • 2
    • 0001620673 scopus 로고    scopus 로고
    • Electrical communication between electrodes and enzymes mediated by redox hydrogels
    • Calvo E.J., Etchenique R. Electrical communication between electrodes and enzymes mediated by redox hydrogels. Analytical Chemsitry. 68:1996;4186-4193.
    • (1996) Analytical Chemsitry , vol.68 , pp. 4186-4193
    • Calvo, E.J.1    Etchenique, R.2
  • 3
    • 0033620585 scopus 로고    scopus 로고
    • Biomolecule immobolization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review
    • Cosneir S. Biomolecule immobolization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review. Biosensors and Bioelectronics. 14:1999;443-456.
    • (1999) Biosensors and Bioelectronics , vol.14 , pp. 443-456
    • Cosneir, S.1
  • 4
    • 0000410869 scopus 로고
    • Electrical communication between redox centers of glucose oxidase and electrodes via electrostatically and covalently bound redox polymer
    • Degani Y., Heller A. Electrical communication between redox centers of glucose oxidase and electrodes via electrostatically and covalently bound redox polymer. Journal of the American Chemical Society. 111:1989;2357-2358.
    • (1989) Journal of the American Chemical Society , vol.111 , pp. 2357-2358
    • Degani, Y.1    Heller, A.2
  • 5
    • 0345580647 scopus 로고    scopus 로고
    • Detection of uric acid with a new type of conducting polymer-based enzymatic sensor by bipotentiostatic technique
    • Dobey R., Harsanyi G., Visy C. Detection of uric acid with a new type of conducting polymer-based enzymatic sensor by bipotentiostatic technique. Analytica Chimica Acta. 385:1999;187-194.
    • (1999) Analytica Chimica Acta , vol.385 , pp. 187-194
    • Dobey, R.1    Harsanyi, G.2    Visy, C.3
  • 7
    • 0032078557 scopus 로고    scopus 로고
    • Direct electrochemistry of membrane-entrapped horseradish peroxidase. Part II: Amperometric detection of hydrogen peroxidase
    • Ferri T., Poscia A., Santucci R. Direct electrochemistry of membrane-entrapped horseradish peroxidase. Part II: amperometric detection of hydrogen peroxidase. Bioelectrochemistry and Bioenergetics. 45:1998;221-226.
    • (1998) Bioelectrochemistry and Bioenergetics , vol.45 , pp. 221-226
    • Ferri, T.1    Poscia, A.2    Santucci, R.3
  • 8
    • 0024110433 scopus 로고
    • Immobilization of glucose oxidase in ferrocene-modified pyrrole polymers
    • Foulds N.C., Lowe C.R. Immobilization of glucose oxidase in ferrocene-modified pyrrole polymers. Analytical Chemistry. 60:1988;2473-2478.
    • (1988) Analytical Chemistry , vol.60 , pp. 2473-2478
    • Foulds, N.C.1    Lowe, C.R.2
  • 9
    • 0025366526 scopus 로고
    • Cross-linked redox gels containing glucose oxidase for amperometric biosensor applications
    • Gregg B.A., Heller A. Cross-linked redox gels containing glucose oxidase for amperometric biosensor applications. Analytical Chemistry. 62:1990;258-263.
    • (1990) Analytical Chemistry , vol.62 , pp. 258-263
    • Gregg, B.A.1    Heller, A.2
  • 10
    • 0000666893 scopus 로고
    • Peroxidas, catalases and chloroperoxidases
    • Dolphin D. New York: Academic Press. Chapter 6
    • Hewson W.D., Hager L.P. Peroxidas, catalases and chloroperoxidases. Dolphin D. The porphyrins. VII B:1979;Academic Press, New York. Chapter 6.
    • (1979) The porphyrins , vol.7 B
    • Hewson, W.D.1    Hager, L.P.2
  • 11
    • 0035304513 scopus 로고    scopus 로고
    • Amperometric biosensor for polyphenol based on horseradish peroxidase immobilized on gold electrodes
    • Imabayashi S., Kong Y.T., Watanabe M. Amperometric biosensor for polyphenol based on horseradish peroxidase immobilized on gold electrodes. Electroanalysis. 13:(5):2001;408-412.
    • (2001) Electroanalysis , vol.13 , Issue.5 , pp. 408-412
    • Imabayashi, S.1    Kong, Y.T.2    Watanabe, M.3
  • 12
    • 49249148639 scopus 로고
    • General expression of the linear potential sweep voltamogram in the case of diffusionless electrochemical systems
    • Laviron E. General expression of the linear potential sweep voltamogram in the case of diffusionless electrochemical systems. Journal of Electroanalytical Chemistry. 101:1979;19-28.
    • (1979) Journal of Electroanalytical Chemistry , vol.101 , pp. 19-28
    • Laviron, E.1
  • 13
    • 0037185285 scopus 로고    scopus 로고
    • Simple preparation of terthiophene-3′-carboxylic acid and characterization of its polymer
    • Lee T.Y., Shim Y.B., Shin S.C. Simple preparation of terthiophene- 3′-carboxylic acid and characterization of its polymer. Synthetic Metals. 126:2002;105-110.
    • (2002) Synthetic Metals , vol.126 , pp. 105-110
    • Lee, T.Y.1    Shim, Y.B.2    Shin, S.C.3
  • 14
    • 0031152495 scopus 로고    scopus 로고
    • The electrochemical study of oxidation-reduction properties of horseradish peroxidase
    • Li J., Dong S. The electrochemical study of oxidation-reduction properties of horseradish peroxidase. Journal of Electroanalytical Chemistry. 431:1997;19-22.
    • (1997) Journal of Electroanalytical Chemistry , vol.431 , pp. 19-22
    • Li, J.1    Dong, S.2
  • 15
    • 0001962566 scopus 로고    scopus 로고
    • Electron transfer principles in amperometric biosensors: Direct electron transfer between enzymes and electrode surface
    • Lötzbeyer T., Schuhmann W., Schmidt H.L. Electron transfer principles in amperometric biosensors: direct electron transfer between enzymes and electrode surface. Sensors and Actuators, B. 33:1996;50-54.
    • (1996) Sensors and Actuators, B , vol.33 , pp. 50-54
    • Lötzbeyer, T.1    Schuhmann, W.2    Schmidt, H.L.3
  • 16
    • 0037640489 scopus 로고    scopus 로고
    • Minizymes. A new strategy for the development of reagentless amperometric biosensors based on direct electron-transfer processes
    • Lötzbeyer T., Schuhmann W., Schmidt H.L. Minizymes. A new strategy for the development of reagentless amperometric biosensors based on direct electron-transfer processes. Bioelectrochemistry and Bioenergetics. 42:1997;1-6.
    • (1997) Bioelectrochemistry and Bioenergetics , vol.42 , pp. 1-6
    • Lötzbeyer, T.1    Schuhmann, W.2    Schmidt, H.L.3
  • 17
    • 0033329037 scopus 로고    scopus 로고
    • Electrocatalysis at conducting polymers
    • Malinauskas A. Electrocatalysis at conducting polymers. Synthetic Metals. 107:1999;75-83.
    • (1999) Synthetic Metals , vol.107 , pp. 75-83
    • Malinauskas, A.1
  • 18
    • 0035888327 scopus 로고    scopus 로고
    • A reagentless glucose biosensor based on glucose oxidase entrapped into osmium-complex modified polypyrrole films
    • Reiter S., Habermüller K., Schuhmann W. A reagentless glucose biosensor based on glucose oxidase entrapped into osmium-complex modified polypyrrole films. Sensors and Actuators, B. 79:2001;150-156.
    • (2001) Sensors and Actuators, B , vol.79 , pp. 150-156
    • Reiter, S.1    Habermüller, K.2    Schuhmann, W.3
  • 20
    • 0028909544 scopus 로고
    • Electron-transfer pathways in amperometric biosensors. Ferrocene-modified enzymes entrapped in conducting-polymer layers
    • Schuhmann W. Electron-transfer pathways in amperometric biosensors. Ferrocene-modified enzymes entrapped in conducting-polymer layers. Biosensors and Bioelectronics. 10:1995;181-193.
    • (1995) Biosensors and Bioelectronics , vol.10 , pp. 181-193
    • Schuhmann, W.1
  • 21
    • 0036183025 scopus 로고    scopus 로고
    • Amperometric enzyme biosensors based on optimized electron-transfer pathways and non-manual immobilization procedures
    • Schuhmann W. Amperometric enzyme biosensors based on optimized electron-transfer pathways and non-manual immobilization procedures. Reviews in Molecular Biochemistry. 82:2002;425-441.
    • (2002) Reviews in Molecular Biochemistry , vol.82 , pp. 425-441
    • Schuhmann, W.1
  • 22
    • 0032049358 scopus 로고    scopus 로고
    • Kinetic analysis of electron transfer from a graphite coating to horseradish peroxidase
    • Tatsuma T., Ariyama K., Oyama N. Kinetic analysis of electron transfer from a graphite coating to horseradish peroxidase. Journal of Electroanalytical Chemistry. 446:1998;205-209.
    • (1998) Journal of Electroanalytical Chemistry , vol.446 , pp. 205-209
    • Tatsuma, T.1    Ariyama, K.2    Oyama, N.3
  • 24
    • 58449114925 scopus 로고    scopus 로고
    • Glucose-sensing characteristics of conducting polymer bound with glucose oxidase
    • Yamauchi T., Kojima K., Shimomura M., Miyauchi S. Glucose-sensing characteristics of conducting polymer bound with glucose oxidase. Synthetic Metals. 102:1999;1320.
    • (1999) Synthetic Metals , vol.102 , pp. 1320
    • Yamauchi, T.1    Kojima, K.2    Shimomura, M.3    Miyauchi, S.4
  • 26
    • 0034142018 scopus 로고    scopus 로고
    • Direct electrochemistry of horseradish peroxidase immobilized on a colloid/cysteamine-modified gold electrode
    • Yi X., Xian J.X., Yuan C.H. Direct electrochemistry of horseradish peroxidase immobilized on a colloid/cysteamine-modified gold electrode. Analytical Biochemistry. 278:2000;22-28.
    • (2000) Analytical Biochemistry , vol.278 , pp. 22-28
    • Yi, X.1    Xian, J.X.2    Yuan, C.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.