Volumn 11, Issue 2, 2003, Pages 83-112

Cryogenic detectors and their application to x-ray fluorescence analysis

Author keywords

[No Author keywords available]

Indexed keywords

ABSORPTION SPECTROSCOPY; CALORIMETERS; ENERGY DISPERSIVE SPECTROSCOPY; FLUORESCENCE; JOSEPHSON JUNCTION DEVICES; LOW TEMPERATURE OPERATIONS; SEMICONDUCTOR DEVICES; TUNNEL JUNCTIONS;

EID: 0141502438     PISSN: 08953996     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (8)

References (54)
  • 5
    • 0031504411 scopus 로고    scopus 로고
    • First use of NTD germanium-based microcalorimeters for high-resolution, broadband x-ray microanalysis
    • E. Silver, M. LeGros, G. Austin, N. Madden, J. Beeman and E. Haller, First Use of NTD Germanium-Based Microcalorimeters For High-Resolution, Broadband X-ray Microanalysis, X-ray Spectrometry 26 (1997), 265-268.
    • (1997) X-ray Spectrometry , vol.26 , pp. 265-268
    • Silver, E.1    LeGros, M.2    Austin, G.3    Madden, N.4    Beeman, J.5    Haller, E.6
  • 10
    • 36549092669 scopus 로고
    • Quasiparticle trapping and the quasiparticle multiplier
    • N.E. Booth, Quasiparticle trapping and the quasiparticle multiplier, Applied Physics Letters 50 (1987), 293-295.
    • (1987) Applied Physics Letters , vol.50 , pp. 293-295
    • Booth, N.E.1
  • 11
    • 0001178883 scopus 로고
    • Energy-resolving superconducting x-ray detectors with charge amplification and multiple quasiparticle tunneling
    • C.A. Mears, S.E. Labov and A.T. Barfknecht, Energy-resolving superconducting x-ray detectors with charge amplification and multiple quasiparticle tunneling, Applied Physics Letters 63 (1993), 2961-2963.
    • (1993) Applied Physics Letters , vol.63 , pp. 2961-2963
    • Mears, C.A.1    Labov, S.E.2    Barfknecht, A.T.3
  • 12
    • 0001206135 scopus 로고
    • The statistical noise due to tunneling in superconducting tunnel junction detectors
    • D.J. Goldie, P.L. Brink, C. Patel, N.E. Booth and G.L. Salmon, The statistical noise due to tunneling in superconducting tunnel junction detectors, Appl. Phys. Lett. 64 (1994), 3169-3171.
    • (1994) Appl. Phys. Lett. , vol.64 , pp. 3169-3171
    • Goldie, D.J.1    Brink, P.L.2    Patel, C.3    Booth, N.E.4    Salmon, G.L.5
  • 13
    • 0000995710 scopus 로고
    • Temperature and magnetic field dependence of the Josephson tunneling current
    • M.D. Fiske, Temperature and Magnetic Field Dependence of the Josephson Tunneling Current, Review of Modern Physics 36 (1994), 221-222.
    • (1964) Review of Modern Physics , vol.36 , pp. 221-222
    • Fiske, M.D.1
  • 20
    • 0141462242 scopus 로고    scopus 로고
    • Investigation of high-resolution superconducting tunnel junction detectors for low-energy x-ray fluorescence analysis
    • B. Beckhoff, R. Fliegauf and G. Ulm, Investigation of high-resolution superconducting tunnel junction detectors for low-energy x-ray fluorescence analysis, to be published in Spectromchimica Acta B (2002).
    • (2002) Spectromchimica Acta B
    • Beckhoff, B.1    Fliegauf, R.2    Ulm, G.3
  • 24
    • 36448999994 scopus 로고
    • An application of electrothermal feedback for high resolution cryogenic particle detection
    • K.D. Irwin, An application of electrothermal feedback for high resolution cryogenic particle detection, Applied Physics Letters 66 (1995), 1998-2000.
    • (1995) Applied Physics Letters , vol.66 , pp. 1998-2000
    • Irwin, K.D.1
  • 29
  • 30
    • 0001421562 scopus 로고
    • Adiabatic demagnetization refrigerators for small laboratory experiments and space astronomy
    • C. Hagmann and P.L. Richards, Adiabatic demagnetization refrigerators for small laboratory experiments and space astronomy, Cryogenics 35 (1995), 303-309.
    • (1995) Cryogenics , vol.35 , pp. 303-309
    • Hagmann, C.1    Richards, P.L.2
  • 32
    • 0000206426 scopus 로고
    • Two-stage magnetic refrigerator for astronomical applications with reservoir temperatures above 4 K
    • C. Hagmann and P.L. Richards, Two-stage magnetic refrigerator for astronomical applications with reservoir temperatures above 4 K, Cryogenics 34 (1994), 221-226.
    • (1994) Cryogenics , vol.34 , pp. 221-226
    • Hagmann, C.1    Richards, P.L.2
  • 33
    • 0000650002 scopus 로고    scopus 로고
    • A two-stage pulse tube cooler operating below 4 K
    • C. Wang, G. Thummes and C. Heiden, A two-stage pulse tube cooler operating below 4 K, Cryogenics 37 (1997), 159.
    • (1997) Cryogenics , vol.37 , pp. 159
    • Wang, C.1    Thummes, G.2    Heiden, C.3
  • 39
    • 0036494026 scopus 로고    scopus 로고
    • A multichannel superconducting soft x-ray spectrometer for high-resolution spectroscopy of dilute samples
    • S. Friedrich, T. Funk, O. Drury, S.E. Labov and S.P. Cramer, A multichannel superconducting soft x-ray spectrometer for high-resolution spectroscopy of dilute samples, Review of Scientific Instruments 73 (2002), 1629-1632.
    • (2002) Review of Scientific Instruments , vol.73 , pp. 1629-1632
    • Friedrich, S.1    Funk, T.2    Drury, O.3    Labov, S.E.4    Cramer, S.P.5
  • 40
    • 0035476356 scopus 로고    scopus 로고
    • Improved energy resolution of x-ray single photon imaging spectrometers using superconducting tunnel junctions
    • L. Li, L. Frunzio, C. Wilson, D.E. Prober, A.E. Szymkowiak and S.H. Moseley, Improved energy resolution of x-ray single photon imaging spectrometers using superconducting tunnel junctions, Journal of Applied Physics 90 (2001), 3645-3647.
    • (2001) Journal of Applied Physics , vol.90 , pp. 3645-3647
    • Li, L.1    Frunzio, L.2    Wilson, C.3    Prober, D.E.4    Szymkowiak, A.E.5    Moseley, S.H.6
  • 43
    • 0029764072 scopus 로고    scopus 로고
    • All-in-one detectors for the faintest objects
    • G. Schilling, All-in-One Detectors for the Faintest Objects, Science 274 (1996), 36-38.
    • (1996) Science , vol.274 , pp. 36-38
    • Schilling, G.1
  • 45
    • 0141797118 scopus 로고    scopus 로고
    • Microcalorimeters may provide a solution to the big problem of small contaminants
    • R. Ladbury, Microcalorimeters May Provide a Solution to the Big Problem of Small Contaminants, Physics Today July 1998 (1998), 19-21.
    • (1998) Physics Today July 1998 , pp. 19-21
    • Ladbury, R.1
  • 47
    • 0036498327 scopus 로고    scopus 로고
    • SQUID multiplexers for transition edge sensors
    • K.D. Irwin, SQUID multiplexers for transition edge sensors, Physica C368 (2002), 203-208.
    • (2002) Physica , vol.C368 , pp. 203-208
    • Irwin, K.D.1
  • 49
    • 0036469869 scopus 로고    scopus 로고
    • High-resolution energy-dispersive x-ray spectroscopic analysis of ultrathin ion diffusion barriers using microcalorimetry
    • R.E. Geer, D. Wu and D.A. Wollman, High-resolution energy-dispersive x-ray spectroscopic analysis of ultrathin ion diffusion barriers using microcalorimetry, Journal of Applied Physics 91 (2002), 1099-1103.
    • (2002) Journal of Applied Physics , vol.91 , pp. 1099-1103
    • Geer, R.E.1    Wu, D.2    Wollman, D.A.3
  • 50
    • 24644495539 scopus 로고
    • Fluorescence-detection of EXAFS: Sensitivity enhancement for dilute species and thin films
    • J. Jaclevic, J.A. Kirby, M.P. Klein and A.S. Robinson, Fluorescence-detection of EXAFS: Sensitivity enhancement for dilute species and thin films, Solid State Communications 23 (1977), 379-382.
    • (1977) Solid State Communications , vol.23 , pp. 679-682
    • Jaclevic, J.1    Kirby, J.A.2    Klein, M.P.3    Robinson, A.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.