메뉴 건너뛰기




Volumn 10, Issue 3, 2003, Pages 463-475

Endoluminal AAA repair using intravascular ultrasound for graft planning and deployment: A 2-year community-based experience

Author keywords

Abdominal aortic aneurysm; Ancure stent graft; AneuRx stent graft; Aortic neck; Atherosclerosis; Endovascular repair; Intravascular ultrasound; Outcome analysis; Secondary intervention

Indexed keywords

ANESTHETIC AGENT; CONTRAST MEDIUM; TISSUE PLASMINOGEN ACTIVATOR;

EID: 0141479049     PISSN: 15266028     EISSN: None     Source Type: Journal    
DOI: 10.1583/1545-1550(2003)010<0463:EARUIU>2.0.CO;2     Document Type: Article
Times cited : (27)

References (47)
  • 1
    • 0035650686 scopus 로고    scopus 로고
    • Impact of exclusion criteria on patient selection for endovascular abdominal aortic aneurysm repair
    • Carpenter JP, Baum RA, Barker CF, et al. Impact of exclusion criteria on patient selection for endovascular abdominal aortic aneurysm repair. J Vasc Surg. 2001;34:1050-1054.
    • (2001) J Vasc Surg , vol.34 , pp. 1050-1054
    • Carpenter, J.P.1    Baum, R.A.2    Barker, C.F.3
  • 2
    • 0028842765 scopus 로고
    • Initial experience with transluminally placed endovascular grafts for the treatment of complex vascular lesions
    • Marin ML, Veith FJ, Cynamon J, et al. Initial experience with transluminally placed endovascular grafts for the treatment of complex vascular lesions. Ann Surg. 1995;222:449-465.
    • (1995) Ann Surg , vol.222 , pp. 449-465
    • Marin, M.L.1    Veith, F.J.2    Cynamon, J.3
  • 3
    • 0032904804 scopus 로고    scopus 로고
    • Accurate assessment of abdominal aortic aneurysm by intravascular ultrasound: Validation with computed tomographic angiography
    • van Essen JA, Gussenhoven EJ, van der Lugt A, et al. Accurate assessment of abdominal aortic aneurysm by intravascular ultrasound: validation with computed tomographic angiography. J Vasc Surg. 1999;29:631-638.
    • (1999) J Vasc Surg , vol.29 , pp. 631-638
    • Van Essen, J.A.1    Gussenhoven, E.J.2    Van der Lugt, A.3
  • 4
    • 0033867530 scopus 로고    scopus 로고
    • Can preoperative spiral CT scans alone determine the feasibility of endovascular AAA repair? A comparison to angiographic measurements
    • Shin CK, Rodino W, Kirwin JD, et al. Can preoperative spiral CT scans alone determine the feasibility of endovascular AAA repair? A comparison to angiographic measurements. J Endovasc Ther. 2000;7:177-183.
    • (2000) J Endovasc Ther , vol.7 , pp. 177-183
    • Shin, C.K.1    Rodino, W.2    Kirwin, J.D.3
  • 5
    • 0030869362 scopus 로고    scopus 로고
    • Preoperative sizing of grafts for transfemoral endovascular aneurysm management: A prospective comparative study of spiral CT angiography, arteriography, and conventional CT imaging
    • Broeders IAMJ, Blankensteijn JD, Olree M, et al. Preoperative sizing of grafts for transfemoral endovascular aneurysm management: a prospective comparative study of spiral CT angiography, arteriography, and conventional CT imaging. J Endovasc Surg. 1997;4:252-261.
    • (1997) J Endovasc Surg , vol.4 , pp. 252-261
    • Broeders, I.A.M.J.1    Blankensteijn, J.D.2    Olree, M.3
  • 6
    • 0032887289 scopus 로고    scopus 로고
    • Abdominal aortic aneurysm morphology in candidates for endovascular repair evaluated with spiral computed tomography and digital subtraction angiography
    • Resch T, Ivancev K, Lindh M, et al. Abdominal aortic aneurysm morphology in candidates for endovascular repair evaluated with spiral computed tomography and digital subtraction angiography. J Endovasc Surg. 1999;6:227-232.
    • (1999) J Endovasc Surg , vol.6 , pp. 227-232
    • Resch, T.1    Ivancev, K.2    Lindh, M.3
  • 7
    • 0034194351 scopus 로고    scopus 로고
    • Feasibility of using dynamic contrast-enhanced magnetic resonance angiography as the sole imaging modality prior to endovascular repair of abdominal aortic aneurysms
    • Ludman CN, Yusuf SW, Whitaker SC, et al. Feasibility of using dynamic contrast-enhanced magnetic resonance angiography as the sole imaging modality prior to endovascular repair of abdominal aortic aneurysms. Eur J Vasc Endovasc Surg. 2000;19:524-530.
    • (2000) Eur J Vasc Endovasc Surg , vol.19 , pp. 524-530
    • Ludman, C.N.1    Yusuf, S.W.2    Whitaker, S.C.3
  • 8
    • 0029973892 scopus 로고    scopus 로고
    • Comparison of magnetic resonance imaging measurements of abdominal aortic aneurysms with measurements obtained by other imaging techniques and intraoperative measurements: Possible implications for endovascular grafting
    • Fox AD, Whiteley MS, Murphy P, et al. Comparison of magnetic resonance imaging measurements of abdominal aortic aneurysms with measurements obtained by other imaging techniques and intraoperative measurements: possible implications for endovascular grafting. J Vasc Surg. 1996;24:632-638.
    • (1996) J Vasc Surg , vol.24 , pp. 632-638
    • Fox, A.D.1    Whiteley, M.S.2    Murphy, P.3
  • 9
    • 0036136287 scopus 로고    scopus 로고
    • Using three-dimensional rotational angiography for sizing of covered stents
    • van den Berg JC, Overtoom TT, de Valois JC, et al. Using three-dimensional rotational angiography for sizing of covered stents. AJR Am J Roentgenol. 2002;178:149-152.
    • (2002) AJR Am J Roentgenol , vol.178 , pp. 149-152
    • Van den Berg, J.C.1    Overtoom, T.T.2    De Valois, J.C.3
  • 10
    • 0033914503 scopus 로고    scopus 로고
    • The value of intraoperative intravascular ultrasound for determining stent graft size (excluding abdominal aortic aneurysms) with a modular system
    • Tutein Nolthenius RP, van den Berg JC, Moll FL. The value of intraoperative intravascular ultrasound for determining stent graft size (excluding abdominal aortic aneurysms) with a modular system. Ann Vasc Surg. 2000;14:311-317.
    • (2000) Ann Vasc Surg , vol.14 , pp. 311-317
    • Tutein Nolthenius, R.P.1    Van den Berg, J.C.2    Moll, F.L.3
  • 11
    • 0030273547 scopus 로고    scopus 로고
    • Intraoperative transesophageal echocardiography and epiaortic ultrasound for assessment of atherosclerosis of the thoracic aorta
    • Davila-Roman VG, Phillips KJ, Daily BB, et al. Intraoperative transesophageal echocardiography and epiaortic ultrasound for assessment of atherosclerosis of the thoracic aorta. J Am Coll Cardiol. 1996;28:942-947.
    • (1996) J Am Coll Cardiol , vol.28 , pp. 942-947
    • Davila-Roman, V.G.1    Phillips, K.J.2    Daily, B.B.3
  • 12
    • 0026261869 scopus 로고
    • Intraoperative ultrasonographic evaluation of the ascending aorta in 100 consecutive patients undergoing cardiac surgery
    • Davila-Roman VG, Barzilai B, Wareing TH, et al. Intraoperative ultrasonographic evaluation of the ascending aorta in 100 consecutive patients undergoing cardiac surgery. Circulation. 1991;84(5 Suppl):III47-53.
    • (1991) Circulation , vol.84 , Issue.5 SUPPL.
    • Davila-Roman, V.G.1    Barzilai, B.2    Wareing, T.H.3
  • 13
    • 0031050495 scopus 로고    scopus 로고
    • Intravascular ultrasound: The ultimate tool for abdominal aortic aneurysm assessment and endovascular graft delivery
    • White RA, Donayre CE, Kopchok G, et al. Intravascular ultrasound: the ultimate tool for abdominal aortic aneurysm assessment and endovascular graft delivery. J Endovasc Surg. 1997;4:45-55.
    • (1997) J Endovasc Surg , vol.4 , pp. 45-55
    • White, R.A.1    Donayre, C.E.2    Kopchok, G.3
  • 14
    • 0029087423 scopus 로고
    • Comparison of the utility of CT scans and intravascular ultrasound in endovascular aortic grafting
    • Verbin C, Scoccianti M, Kopchok G, et al. Comparison of the utility of CT scans and intravascular ultrasound in endovascular aortic grafting. Ann Vasc Surg. 1995;9:434-440.
    • (1995) Ann Vasc Surg , vol.9 , pp. 434-440
    • Verbin, C.1    Scoccianti, M.2    Kopchok, G.3
  • 15
    • 0030947672 scopus 로고    scopus 로고
    • Endoleak as a complication of endoluminal grafting of abdominal aortic aneurysms: Classification, incidence, diagnosis, and management
    • White GH, Yu W, May J, et al. Endoleak as a complication of endoluminal grafting of abdominal aortic aneurysms: classification, incidence, diagnosis, and management. J Endovasc Surg. 1997;4:152-168.
    • (1997) J Endovasc Surg , vol.4 , pp. 152-168
    • White, G.H.1    Yu, W.2    May, J.3
  • 16
    • 0032061766 scopus 로고    scopus 로고
    • Type I and type II endoleaks: A more useful classification for reporting results of endoluminal AAA repair
    • White GH, May J, Waugh RC, et al. Type I and type II endoleaks: a more useful classification for reporting results of endoluminal AAA repair [letter]. J Endovasc Surg. 1998;5:189-191.
    • (1998) J Endovasc Surg , vol.5 , pp. 189-191
    • White, G.H.1    May, J.2    Waugh, R.C.3
  • 17
    • 0031647176 scopus 로고    scopus 로고
    • Type III and type IV endoleak: Toward a complete definition of blood flow in the sac after endoluminal AAA repair
    • White GH, May J, Waugh RC, et al. Type III and type IV endoleak: toward a complete definition of blood flow in the sac after endoluminal AAA repair. J Endovasc Surg. 1998;5:305-309.
    • (1998) J Endovasc Surg , vol.5 , pp. 305-309
    • White, G.H.1    May, J.2    Waugh, R.C.3
  • 18
    • 0030957390 scopus 로고    scopus 로고
    • Utility of intravascular ultrasound in peripheral interventions
    • White RA, Donayre CE, Kopchok GE, et al. Utility of intravascular ultrasound in peripheral interventions. Tex Heart Inst J. 1997;24:28-34.
    • (1997) Tex Heart Inst J , vol.24 , pp. 28-34
    • White, R.A.1    Donayre, C.E.2    Kopchok, G.E.3
  • 19
    • 0031929917 scopus 로고    scopus 로고
    • Intravascular ultrasonography allows accurate assessment of abdominal aortic aneurysm: An in vitro validation study
    • van Essen JA, van der Lugt A, Gussenhoven EJ, et al. Intravascular ultrasonography allows accurate assessment of abdominal aortic aneurysm: an in vitro validation study. J Vasc Surg. 1998;27:347-353.
    • (1998) J Vasc Surg , vol.27 , pp. 347-353
    • Van Essen, J.A.1    Van der Lugt, A.2    Gussenhoven, E.J.3
  • 20
    • 0026948885 scopus 로고
    • Geometric accuracy of intravascular ultrasound imaging
    • Chae JS, Brisken AF, Maurer G, et al. Geometric accuracy of intravascular ultrasound imaging. J Am Soc Echocardiogr. 1992;5:577-587.
    • (1992) J Am Soc Echocardiogr , vol.5 , pp. 577-587
    • Chae, J.S.1    Brisken, A.F.2    Maurer, G.3
  • 21
    • 0036263628 scopus 로고    scopus 로고
    • Intravascular ultrasound imaging in the assessment of atherosclerotic plaques in rabbit abdominal aorta: Comparison with histologic findings
    • Ochiai R, Kisanuki A, Asada Y, et al. Intravascular ultrasound imaging in the assessment of atherosclerotic plaques in rabbit abdominal aorta: comparison with histologic findings. Invest Radiol. 2002;37:309-313.
    • (2002) Invest Radiol , vol.37 , pp. 309-313
    • Ochiai, R.1    Kisanuki, A.2    Asada, Y.3
  • 22
    • 0026750130 scopus 로고
    • Surgical implications of transesophageal echocardiography to grade the atheromatous aortic arch
    • Ribakove GH, Katz ES, Galloway AC, et al. Surgical implications of transesophageal echocardiography to grade the atheromatous aortic arch. Ann Thorac Surg. 1992;53:758-763.
    • (1992) Ann Thorac Surg , vol.53 , pp. 758-763
    • Ribakove, G.H.1    Katz, E.S.2    Galloway, A.C.3
  • 23
    • 0033117118 scopus 로고    scopus 로고
    • Atherosclerosis of the ascending aorta is an independent predictor of long-term neurologic events and mortality
    • Davila-Roman VG, Murphy SF, Nickerson NJ, et al. Atherosclerosis of the ascending aorta is an independent predictor of long-term neurologic events and mortality. J Am Coll Cardiol. 1999;33:1308-1316.
    • (1999) J Am Coll Cardiol , vol.33 , pp. 1308-1316
    • Davila-Roman, V.G.1    Murphy, S.F.2    Nickerson, N.J.3
  • 24
    • 0030846394 scopus 로고    scopus 로고
    • The use of intravascular ultrasound as control procedure for the deployment of endovascular stented grafts
    • Vogt KC, Brunkwall J, Malina M, et al. The use of intravascular ultrasound as control procedure for the deployment of endovascular stented grafts. Eur J Vasc Endovasc Surg. 1997;13:592-596.
    • (1997) Eur J Vasc Endovasc Surg , vol.13 , pp. 592-596
    • Vogt, K.C.1    Brunkwall, J.2    Malina, M.3
  • 25
    • 0034956962 scopus 로고    scopus 로고
    • Complications in endoluminal repair of abdominal aortic aneurysms
    • Hausegger KA, Schedlbauer P, Deutschmann HA, et al. Complications in endoluminal repair of abdominal aortic aneurysms. Eur J Radiol. 2001;39:22-33.
    • (2001) Eur J Radiol , vol.39 , pp. 22-33
    • Hausegger, K.A.1    Schedlbauer, P.2    Deutschmann, H.A.3
  • 26
    • 0031453479 scopus 로고    scopus 로고
    • Three-year experience with modular stent-graft devices for endovascular AAA treatment
    • Stelter WJ, Umscheid T, Ziegler P. Three-year experience with modular stent-graft devices for endovascular AAA treatment. J Endovasc Surg. 1997;4:362-369.
    • (1997) J Endovasc Surg , vol.4 , pp. 362-369
    • Stelter, W.J.1    Umscheid, T.2    Ziegler, P.3
  • 27
    • 0345073276 scopus 로고    scopus 로고
    • Leakages after endovascular repair of aortic aneurysms: Classification based on findings at CT, angiography, and radiography
    • Görich J, Rilinger N, Sokiranski R, et al. Leakages after endovascular repair of aortic aneurysms: classification based on findings at CT, angiography, and radiography. Radiology. 1999;213:767-772.
    • (1999) Radiology , vol.213 , pp. 767-772
    • Görich, J.1    Rilinger, N.2    Sokiranski, R.3
  • 29
    • 0034809002 scopus 로고    scopus 로고
    • Preliminary results of endovascular abdominal aortic aneurysm exclusion with the AneuRx stent-graft
    • Howell M, Strickman N, Mortazavi A, et al. Preliminary results of endovascular abdominal aortic aneurysm exclusion with the AneuRx stent-graft. J Am Coll Cardiol. 2001;38:1040-1046.
    • (2001) J Am Coll Cardiol , vol.38 , pp. 1040-1046
    • Howell, M.1    Strickman, N.2    Mortazavi, A.3
  • 30
    • 0035118542 scopus 로고    scopus 로고
    • The AneuRx stent graft: Four-year results and worldwide experience 2000
    • Zarins CK, White RA, Moll FL, et al. The AneuRx stent graft: four-year results and worldwide experience 2000. J Vasc Surg. 2001;33:S135-145.
    • (2001) J Vasc Surg , vol.33
    • Zarins, C.K.1    White, R.A.2    Moll, F.L.3
  • 31
    • 0034974385 scopus 로고    scopus 로고
    • Endoluminal repair of abdominal aortic aneurysms-state of the art
    • May J, White GH, Harris JP. Endoluminal repair of abdominal aortic aneurysms-state of the art. Eur J Radiol. 2001;39:16-21.
    • (2001) Eur J Radiol , vol.39 , pp. 16-21
    • May, J.1    White, G.H.2    Harris, J.P.3
  • 32
    • 0035212369 scopus 로고    scopus 로고
    • Endovascular abdominal aortic aneurysm repair in 144 patients: Correlation of aneurysm size, proximal aortic neck length, and procedure-related complications
    • Hovsepian DM, Hein AN, Pilgram TK, et al. Endovascular abdominal aortic aneurysm repair in 144 patients: correlation of aneurysm size, proximal aortic neck length, and procedure-related complications. J Vasc Interv Radiol. 2001;12:1373-1882.
    • (2001) J Vasc Interv Radiol , vol.12 , pp. 1373-1882
    • Hovsepian, D.M.1    Hein, A.N.2    Pilgram, T.K.3
  • 33
    • 0028141986 scopus 로고
    • Atherosclerosis of the ascending aorta. Prevalence and role as an independent predictor of cerebrovescular events in cardiac patients
    • Davila-Roman VG, Barzilai B, Wareing TH, et al. Atherosclerosis of the ascending aorta. Prevalence and role as an independent predictor of cerebrovescular events in cardiac patients. Stroke. 1994;25:2010-2016.
    • (1994) Stroke , vol.25 , pp. 2010-2016
    • Davila-Roman, V.G.1    Barzilai, B.2    Wareing, T.H.3
  • 34
    • 0031049161 scopus 로고    scopus 로고
    • Microembolization during endovascular and conventional aneurysm repair
    • Thompson MM, Smith J, Naylor AR, et al. Microembolization during endovascular and conventional aneurysm repair. J Vasc Surg. 1997;25:179-186.
    • (1997) J Vasc Surg , vol.25 , pp. 179-186
    • Thompson, M.M.1    Smith, J.2    Naylor, A.R.3
  • 35
    • 0035106071 scopus 로고    scopus 로고
    • Endovascular stent-grafting in the presence of aortic neck filling defects: Early clinical experience
    • Gitlitz DB, Ramaswami G, Kaplan D, et al. Endovascular stent-grafting in the presence of aortic neck filling defects: early clinical experience. J Vasc Surg. 2001;33:340-344.
    • (2001) J Vasc Surg , vol.33 , pp. 340-344
    • Gitlitz, D.B.1    Ramaswami, G.2    Kaplan, D.3
  • 36
    • 0030857450 scopus 로고    scopus 로고
    • Endovascular treatment of infrarenal abdominal aortic aneurysms by the Stentor system: Preliminary results of 79 cases
    • Mialhe C, Amicabile C, Becquemin JP for the Stentor Retrospective Study Group. Endovascular treatment of infrarenal abdominal aortic aneurysms by the Stentor system: preliminary results of 79 cases. J Vasc Surg. 1997;26:199-209.
    • (1997) J Vasc Surg , vol.26 , pp. 199-209
    • Mialhe, C.1    Amicabile, C.2    Becquemin, J.P.3
  • 37
    • 0036140430 scopus 로고    scopus 로고
    • Causes and outcomes of open conversion and aneurysm rupture after endovascular abdominal aortic aneurysm repair: Can type II endoleaks be dangerous?
    • Buth J, Harris PL, van Marrewijk C. Causes and outcomes of open conversion and aneurysm rupture after endovascular abdominal aortic aneurysm repair: can type II endoleaks be dangerous? J Am Coll Surg. 2002:194:S98-S102.
    • (2002) J Am Coll Surg , vol.194
    • Buth, J.1    Harris, P.L.2    Van Marrewijk, C.3
  • 38
    • 0033360826 scopus 로고    scopus 로고
    • Endotension after endovascular aneurysm repair: Definition, classification, and strategies for surveillance and intervention
    • Gilling-Smith G, Brennan J, Harris P, et al. Endotension after endovascular aneurysm repair: definition, classification, and strategies for surveillance and intervention. J Endovasc Surg. 1999;6:305-307.
    • (1999) J Endovasc Surg , vol.6 , pp. 305-307
    • Gilling-Smith, G.1    Brennan, J.2    Harris, P.3
  • 39
    • 0036121036 scopus 로고    scopus 로고
    • Aneurysm expansion after stent-graft placement in the absence of endoleak
    • Kato N, Shimono T, Hirano T, et al. Aneurysm expansion after stent-graft placement in the absence of endoleak. J Vasc Interv Radiol. 2002;13:321-326.
    • (2002) J Vasc Interv Radiol , vol.13 , pp. 321-326
    • Kato, N.1    Shimono, T.2    Hirano, T.3
  • 40
    • 0033902980 scopus 로고    scopus 로고
    • Abdominal aortic aneurysm rupture following endoluminal graft deployment: Report of a predictable event
    • White RA, Donayre C, Walot I, et al. Abdominal aortic aneurysm rupture following endoluminal graft deployment: report of a predictable event. J Endovasc Ther. 2000;7:257-262.
    • (2000) J Endovasc Ther , vol.7 , pp. 257-262
    • White, R.A.1    Donayre, C.2    Walot, I.3
  • 41
    • 0033782683 scopus 로고    scopus 로고
    • Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: The EUROSTAR experience
    • Harris PL, Vallabhaneni SR, Desgranges P, et al. for the EUROSTAR Collaborators. Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: the EUROSTAR experience. J Vasc Surg. 2000;32:739-749.
    • (2000) J Vasc Surg , vol.32 , pp. 739-749
    • Harris, P.L.1    Vallabhaneni, S.R.2    Desgranges, P.3
  • 42
    • 0031821534 scopus 로고    scopus 로고
    • Persistent collateral perfusion of abdominal aortic aneurysm after endovascular repair does not lead to progressive change in aneurysm diameter
    • Resch T, Ivancev K, Lindh M, et al. Persistent collateral perfusion of abdominal aortic aneurysm after endovascular repair does not lead to progressive change in aneurysm diameter. J Vasc Surg. 1998;28:242-249.
    • (1998) J Vasc Surg , vol.28 , pp. 242-249
    • Resch, T.1    Ivancev, K.2    Lindh, M.3
  • 43
    • 0034891943 scopus 로고    scopus 로고
    • Intraoperative, perioperative and late complications with endovascular therapy of aortic aneurysm
    • Liewald F, Scharrer-Pamler R, Görich J, et al. Intraoperative, perioperative and late complications with endovascular therapy of aortic aneurysm. Eur J Vasc Endovasc Surg. 2001;22:251-256.
    • (2001) Eur J Vasc Endovasc Surg , vol.22 , pp. 251-256
    • Liewald, F.1    Scharrer-Pamler, R.2    Görich, J.3
  • 44
    • 0034972381 scopus 로고    scopus 로고
    • Lessons learnt from the EUROSTAR registry on endovascular repair of abdominal aortic aneurysm repair
    • Vallabhaneni SR, Harris PL. Lessons learnt from the EUROSTAR registry on endovascular repair of abdominal aortic aneurysm repair. Eur J Radiol. 2001;39:34-41.
    • (2001) Eur J Radiol , vol.39 , pp. 34-41
    • Vallabhaneni, S.R.1    Harris, P.L.2
  • 45
    • 0035099062 scopus 로고    scopus 로고
    • Failure of endovascular abdominal aortic aneurysm graft limbs
    • Carpenter JP, Neschis DG, Fairman RM, et al. Failure of endovascular abdominal aortic aneurysm graft limbs. J Vasc Surg. 2001;33:296-303.
    • (2001) J Vasc Surg , vol.33 , pp. 296-303
    • Carpenter, J.P.1    Neschis, D.G.2    Fairman, R.M.3
  • 46
    • 0032992669 scopus 로고    scopus 로고
    • Longitudinal aneurysm shrinkage following endovascular aortic aneurysm repair: A source of intermediate and late complications
    • Harris P, Brennan J, Martin J, et al. Longitudinal aneurysm shrinkage following endovascular aortic aneurysm repair: a source of intermediate and late complications. J Endovasc Surg. 1999;6:11-16.
    • (1999) J Endovasc Surg , vol.6 , pp. 11-16
    • Harris, P.1    Brennan, J.2    Martin, J.3
  • 47
    • 0031058054 scopus 로고    scopus 로고
    • Changing aneurysmal morphology after endovascular grafting: Relation to leakage or persistent perfusion
    • Malina M, Ivancev K, Chuter TAM, et al. Changing aneurysmal morphology after endovascular grafting: relation to leakage or persistent perfusion. J Endovasc Surg, 1997;4:23-30.
    • (1997) J Endovasc Surg , vol.4 , pp. 23-30
    • Malina, M.1    Ivancev, K.2    Chuter, T.A.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.