메뉴 건너뛰기




Volumn 13, Issue 6, 1997, Pages 592-596

The use of intravascular ultrasound as control procedure for the deployment of endovascular stented grafts

Author keywords

Abdominal aortic aneurysms; Endovascular stent grafts; Intravascular ultrasound

Indexed keywords

ABDOMINAL AORTA ANEURYSM; ADULT; AGED; AORTA WALL; ARTERIOGRAPHY; ARTERY GRAFT; ARTICLE; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; FEMALE; GUIDE WIRE; HUMAN; IMAGING; INTRAVASCULAR ULTRASOUND; MALE; MEDICAL DECISION MAKING; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; STENT;

EID: 0030846394     PISSN: 10785884     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1078-5884(97)80069-X     Document Type: Article
Times cited : (35)

References (17)
  • 1
    • 0028917508 scopus 로고
    • Endovascular repair of abdominal aortic aneurysms and other arterial lesions
    • Parodi JC Endovascular repair of abdominal aortic aneurysms and other arterial lesions J Vasc Surg 221 1995 549 557
    • (1995) J Vasc Surg , vol.221 , pp. 549-557
    • Parodi, JC1
  • 2
    • 0028845144 scopus 로고
    • Endovascular repair of abdominal aortic aneurysm: value of postoperative follow-up with helical CT
    • Rozenblit A Marin ML Veith FJ Cynamon J Wahl SI Bakal CW Endovascular repair of abdominal aortic aneurysm: value of postoperative follow-up with helical CT AJR 165 1995 1473 1479
    • (1995) AJR , vol.165 , pp. 1473-1479
    • Rozenblit, A1    Marin, ML2    Veith, FJ3    Cynamon, J4    Wahl, SI5    Bakal, CW6
  • 3
    • 0028073267 scopus 로고
    • Repair of abdominal aortic aneurysm by transfemoral endovascular graft placement
    • Moore WS Vescera CL Repair of abdominal aortic aneurysm by transfemoral endovascular graft placement Ann Surg 220 1994 331 341
    • (1994) Ann Surg , vol.220 , pp. 331-341
    • Moore, WS1    Vescera, CL2
  • 4
    • 85114535457 scopus 로고
    • Intraoperative imaging system requirements
    • Donayre CE White GH White RA Intraoperative imaging system requirements Chuter TAM Donayre CE White RA Endoluminal vascular prostheses First edition 1995 Little, Brown and Company Boston 285 306
    • (1995) , pp. 285-306
    • Donayre, CE1    White, GH2    White, RA3
  • 5
    • 0024956278 scopus 로고
    • Intravascular ultrasonic imaging: histologic and echographic correlation
    • Gussenhoven EJ Essed CE Frietman P Intravascular ultrasonic imaging: histologic and echographic correlation Eur J Vasc Surg 3 1989 571 576
    • (1989) Eur J Vasc Surg , vol.3 , pp. 571-576
    • Gussenhoven, EJ1    Essed, CE2    Frietman, P3
  • 6
    • 0029957458 scopus 로고    scopus 로고
    • Are self-expanding stents superior to balloon-expanded in dilating aortas? An experimental study in pigs
    • Mangell P Malina M Vogt K Are self-expanding stents superior to balloon-expanded in dilating aortas? An experimental study in pigs Eur J Vasc Endovasc Surg 12 1996 287 294
    • (1996) Eur J Vasc Endovasc Surg , vol.12 , pp. 287-294
    • Mangell, P1    Malina, M2    Vogt, K3
  • 7
    • 0030860729 scopus 로고    scopus 로고
    • Prediction of outcome after femoropoliteal balloon angioplasty by intravascular ultrasound
    • Vogt K Just S Rasmussen JG Schroeder TV Prediction of outcome after femoropoliteal balloon angioplasty by intravascular ultrasound Eur J Vasc Endovasc Surg 13 1997 563 568
    • (1997) Eur J Vasc Endovasc Surg , vol.13 , pp. 563-568
    • Vogt, K1    Just, S2    Rasmussen, JG3    Schroeder, TV4
  • 8
    • 0028859576 scopus 로고
    • Intravascular ultrasound predictors of outcome after peripheral balloon angioplasty
    • Gussenhoven EJ van Der Lugt A Pasterkamp G Intravascular ultrasound predictors of outcome after peripheral balloon angioplasty Eur J Vasc Endovasc Surg 10 1995 279 288
    • (1995) Eur J Vasc Endovasc Surg , vol.10 , pp. 279-288
    • Gussenhoven, EJ1    van Der Lugt, A2    Pasterkamp, G3
  • 10
    • 0027294632 scopus 로고
    • Endovascular treatment of abdominal aortic occlusive disease: the impact of stents and intravascular ultrasound imaging
    • Diethrich EB Endovascular treatment of abdominal aortic occlusive disease: the impact of stents and intravascular ultrasound imaging Eur J Vasc Surg 7 1993 228 236
    • (1993) Eur J Vasc Surg , vol.7 , pp. 228-236
    • Diethrich, EB1
  • 11
    • 0028944764 scopus 로고
    • The role of cinefluoroscopy and intravascular ultrasonography in evaluating the deployment of experimental endovascular prostheses
    • White RA Verbin C Kopchok G Scoccianti M de Virgilio C Donayre C The role of cinefluoroscopy and intravascular ultrasonography in evaluating the deployment of experimental endovascular prostheses J Vasc Surg 21 1995 365 374
    • (1995) J Vasc Surg , vol.21 , pp. 365-374
    • White, RA1    Verbin, C2    Kopchok, G3    Scoccianti, M4    de Virgilio, C5    Donayre, C6
  • 12
    • 0029395713 scopus 로고
    • The clinical value of three-dimensional intravascular ultrasound imaging
    • Reid DB Douglas M Diethrich EB The clinical value of three-dimensional intravascular ultrasound imaging J Endovasc Surg 2 1995 356 364
    • (1995) J Endovasc Surg , vol.2 , pp. 356-364
    • Reid, DB1    Douglas, M2    Diethrich, EB3
  • 13
    • 0029087423 scopus 로고
    • Comparison of the utility of Ct-scans and intravascular ultrasound in the endovascular aortic grafting
    • Verbin C Scoccianti M Kopchok G Donayre C White RA Comparison of the utility of Ct-scans and intravascular ultrasound in the endovascular aortic grafting Ann Vasc Surg 9 1995 434 440
    • (1995) Ann Vasc Surg , vol.9 , pp. 434-440
    • Verbin, C1    Scoccianti, M2    Kopchok, G3    Donayre, C4    White, RA5
  • 14
    • 0028534481 scopus 로고
    • Angiographic and intravascular ultrasonographic findings after endovascular stent implantation
    • Bolz K-D Hatlinghus S Wiseth R Myhre HO Gronningsaeter A Angiographic and intravascular ultrasonographic findings after endovascular stent implantation Acta Radiol 35 1994 590 596
    • (1994) Acta Radiol , vol.35 , pp. 590-596
    • Bolz, K-D1    Hatlinghus, S2    Wiseth, R3    Myhre, HO4    Gronningsaeter, A5
  • 17
    • 85114533992 scopus 로고    scopus 로고
    • Malina M, Brunkwall J, Ivancev K, Lindh M, Lindblad B, Riisberg B . May renal arteries be covered by aortic stents? Eur J Endovasc Vasc Surg (in press).


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.