Loci of movement of selected points on the femoral head during normal gait: Three-dimensional computer simulation

Author keywords

computer simulation; gait; polyethylene; total hip arthroplasty; wear; wear tester

Indexed keywords

ARTICLE; COMPUTER SIMULATION; GAIT; HIP PROSTHESIS; JOINT FUNCTION; POLITEF IMPLANT; PROSTHESIS FAILURE; TREATMENT OUTCOME;

EID: 0029852622     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0883-5403(96)80185-9     Document Type: Article
Times cited : (78)

References (9)
  • 1
    • 0001093632 scopus 로고
    • Friction and molecular structure: The behaviour of some thermoplastics
    • Pooley C, Tabor D: Friction and molecular structure: the behaviour of some thermoplastics. Proc R Soc Lond 329A:251, 1972
    • (1972) Proc R Soc Lond , vol.329 A , pp. 251
    • Pooley, C.1    Tabor, D.2
  • 2
    • 27044445925 scopus 로고
    • The biomechanics of the hip joint and its clinical relevance
    • Paul JP: The biomechanics of the hip joint and its clinical relevance. Proc R Soc Med 59:10, 1966
    • (1966) Proc R Soc Med , vol.59 , pp. 10
    • Paul, J.P.1
  • 3
    • 0002989262 scopus 로고
    • Forces transmitted by joints in the human body
    • Paul JP: Forces transmitted by joints in the human body. Proc Instr Mech Engr 181(pt 3F):8, 1966
    • (1966) Proc Instr Mech Engr , vol.181 , Issue.PART 3F , pp. 8
    • Paul, J.P.1
  • 4
    • 0016823891 scopus 로고
    • Rate of wear in total hip replacement
    • Charnley J, Halley D: Rate of wear in total hip replacement. Clin Orthop 112:170, 1975
    • (1975) Clin Orthop , vol.112 , pp. 170
    • Charnley, J.1    Halley, D.2
  • 5
    • 0022219799 scopus 로고
    • Direction and rate of socket wear in Charnley low friction arthroplasty
    • Wroblewski B: Direction and rate of socket wear in Charnley low friction arthroplasty. J Bone Joint Surg 67B:757, 1985
    • (1985) J Bone Joint Surg , vol.67 B , pp. 757
    • Wroblewski, B.1
  • 6
    • 0014574695 scopus 로고
    • Measurement of hip-joint motion during walking
    • Johnston RC, Smidt GL: Measurement of hip-joint motion during walking. J Bone Joint Surg 51A:1083, 1969
    • (1969) J Bone Joint Surg , vol.51 A , pp. 1083
    • Johnston, R.C.1    Smidt, G.L.2
  • 7
    • 0025424645 scopus 로고
    • Measurement of lower extremity kinematics during level walking
    • Kadaba MP, Ramakrishnan HK, Wootten ME: Measurement of lower extremity kinematics during level walking. J Orthop Res 8:383, 1990
    • (1990) J Orthop Res , vol.8 , pp. 383
    • Kadaba, M.P.1    Ramakrishnan, H.K.2    Wootten, M.E.3
  • 9
    • 0024351308 scopus 로고
    • Contact pressures from an instrumented hip endoprosthesis
    • Hodge WA, Carlson KL, Fijan SM et al: Contact pressures from an instrumented hip endoprosthesis. J Bone Joint Surg 71A:1378, 1989
    • (1989) J Bone Joint Surg , vol.71 A , pp. 1378
    • Hodge, W.A.1    Carlson, K.L.2    Fijan, S.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.