-
1
-
-
0037055025
-
Antiretroviral treatment for adult HIV infection in 2002: Updated recommendations of the International AIDS Society-USA Panel
-
Yeni P.G. Hammer S.M. Carpenter C.C. Cooper D.A. Fischl M.A. Gatell J.M. et al. Antiretroviral treatment for adult HIV infection in 2002: updated recommendations of the International AIDS Society-USA Panel JAMA 288 2002 222-235
-
(2002)
JAMA
, vol.288
, pp. 222-235
-
-
Yeni, P.G.1
Hammer, S.M.2
Carpenter, C.C.3
Cooper, D.A.4
Fischl, M.A.5
Gatell, J.M.6
-
2
-
-
0034632793
-
Human immunodeficiency virus type 1 RNA level and CD4 count as prognostic markers and surrogate end points: A meta analysis
-
HIV Surrogate Markers Collaborative Group
-
HIV Surrogate Markers Collaborative Group Human immunodeficiency virus type 1 RNA level and CD4 count as prognostic markers and surrogate end points: a meta analysis J Acquir Immune Defic Syndr 16 2000 1123-1133
-
(2000)
J. Acquir. Immune Defic. Syndr.
, vol.16
, pp. 1123-1133
-
-
-
3
-
-
0024553794
-
CD4 percentage, CD4 number, and CD4:CD8 ratio in HIV infection: Which to choose and how to use
-
Taylor J.M. Fahey J.L. Detels R. Giorgi J.V. CD4 percentage, CD4 number, and CD4:CD8 ratio in HIV infection: which to choose and how to use J Acquir Immune Defic Syndr 2 1989 114-124
-
(1989)
J. Acquir. Immune Defic. Syndr.
, vol.2
, pp. 114-124
-
-
Taylor, J.M.1
Fahey, J.L.2
Detels, R.3
Giorgi, J.V.4
-
5
-
-
0033511780
-
CD4 lymphocyte count as a predictor of the duration of highly active antiretroviral therapy-induced suppression of HIV load
-
Miller V. Staszewski S. Sabin C. Carlebach A. Rottmann C. Weidmann E. et al. CD4 lymphocyte count as a predictor of the duration of highly active antiretroviral therapy-induced suppression of HIV load J Infect Dis 180 1999 530-533
-
(1999)
J. Infect. Dis.
, vol.180
, pp. 530-533
-
-
Miller, V.1
Staszewski, S.2
Sabin, C.3
Carlebach, A.4
Rottmann, C.5
Weidmann, E.6
-
6
-
-
0030868897
-
Positive effects of combined antiretroviral therapy on CD4+ T cell homeostasis and function in advanced HIV disease
-
Autran B. Carcelain G. Li T.S. Blanc C. Mathez D. Tubiana R. et al. Positive effects of combined antiretroviral therapy on CD4+ T cell homeostasis and function in advanced HIV disease Science 277 1997 112-116
-
(1997)
Science
, vol.277
, pp. 112-116
-
-
Autran, B.1
Carcelain, G.2
Li, T.S.3
Blanc, C.4
Mathez, D.5
Tubiana, R.6
-
7
-
-
0042911895
-
Randomized study of intermittent subcutaneous IL-2 therapy without anti-retrovirals versus no treatment
-
XIII International AIDS Conference. LbOr28
-
Youle M, Fisher M, Nelson M, et al. 2000. Randomized study of intermittent subcutaneous IL-2 therapy without anti-retrovirals versus no treatment. XIII International AIDS Conference. LbOr28.
-
(2000)
-
-
Youle, M.1
Fisher, M.2
Nelson, M.3
-
9
-
-
84889158104
-
-
Available at also: http://www.globalfundatm.org/files/ financialcontributions 280502.htm
-
Available at: http://www.unaida.org//acc_access/index.html also: http://www.globalfundatm.org/files/financialcontributions 280502.htm
-
-
-
-
11
-
-
0030055847
-
CD4 and total lymphocyte counts as predictors of HIV disease progression
-
Post F.A. Wood R. Maartens G. CD4 and total lymphocyte counts as predictors of HIV disease progression QJM 89 1996 505-508
-
(1996)
QJM
, vol.89
, pp. 505-508
-
-
Post, F.A.1
Wood, R.2
Maartens, G.3
-
12
-
-
0003643648
-
Scaling up antiretroviral therapy in resource-limited settings: Guidelines for a public health approach
-
World Health Organization World Health Organization, April
-
World Health Organization. Scaling up antiretroviral therapy in resource-limited settings: guidelines for a public health approach. World Health Organization, April, 2002.
-
(2002)
-
-
-
13
-
-
0032213046
-
Correlation among total lymphocyte count, absolute CD4 count, and CD4+ percentage in HIV-1 infected South African patients
-
van der Ryst E. Koetze M. Joubert G. Steyn M. Pieters H. van der Westhuzien M. et al. Correlation among total lymphocyte count, absolute CD4 count, and CD4+ percentage in HIV-1 infected South African patients J Acquir Immune Defic Syndr 19 1998 238-244
-
(1998)
J. Acquir. Immune Defic. Syndr.
, vol.19
, pp. 238-244
-
-
van der Ryst, E.1
Koetze, M.2
Joubert, G.3
Steyn, M.4
Pieters, H.5
van der Westhuzien, M.6
-
14
-
-
0035126095
-
11-color, 13-parameter flow cytometry: Identification of human naive T cells by phenotype, function, and T-cell receptor diversity
-
De Rosa S.C. Herzenberg L.A. Roederer M. 11-color, 13-parameter flow cytometry: identification of human naive T cells by phenotype, function, and T-cell receptor diversity Nat Med 7 2001 245-248
-
(2001)
Nat. Med.
, vol.7
, pp. 245-248
-
-
De Rosa, S.C.1
Herzenberg, L.A.2
Roederer, M.3
-
16
-
-
0031561537
-
Evised guidelines for performing CD4+ T-cell determinations in persons infected with human immunodeficiency virus (HIV)
-
Centers for Disease Control & Prevention
-
Centers for Disease Control & Prevention evised guidelines for performing CD4+ T-cell determinations in persons infected with human immunodeficiency virus (HIV) MMWR Morb Mortal Wkly Rep 46 1997 1-29
-
(1997)
MMWR Morb. Mortal. Wkly. Rep.
, vol.46
, pp. 1-29
-
-
-
17
-
-
0037092181
-
T-cell subset counting and the fight against AIDS: Reflections over a 20-year struggle
-
Mandy F. Nicholson J. Autran B. Janossy G. T-cell subset counting and the fight against AIDS: reflections over a 20-year struggle Cytometry 50 2002 39-45
-
(2002)
Cytometry
, vol.50
, pp. 39-45
-
-
Mandy, F.1
Nicholson, J.2
Autran, B.3
Janossy, G.4
-
18
-
-
0034489798
-
Affordable CD4(+) T-cell counts on 'single-platform' flow cytometers: I. Primary CD4 gating
-
Janossy G. Jani I. Gohde W. Affordable CD4(+) T-cell counts on 'single-platform' flow cytometers: I. Primary CD4 gating Br J Haematol 111 2000 1198-1208
-
(2000)
Br. J. Haematol.
, vol.111
, pp. 1198-1208
-
-
Janossy, G.1
Jani, I.2
Gohde, W.3
-
19
-
-
0037092178
-
Precise CD4 T cell counting using red diode laser excitation: For richer, for poorer
-
Janossy G. Jani I.V. Kahan M. Barnett D. Mandy F. Shapiro H. Precise CD4 T cell counting using red diode laser excitation: for richer, for poorer Clin Cytometry 50 2002 78-85
-
(2002)
Clin. Cytometry
, vol.50
, pp. 78-85
-
-
Janossy, G.1
Jani, I.V.2
Kahan, M.3
Barnett, D.4
Mandy, F.5
Shapiro, H.6
-
21
-
-
0034671209
-
Cytofluorometric methods for assessing absolute numbers of cell subsets in blood
-
European Working Group on Clinical Cell Analysis
-
Brando B. Barnett D. Janossy G. Mandy F. Autran B. Rothe G. et al. Cytofluorometric methods for assessing absolute numbers of cell subsets in blood. European Working Group on Clinical Cell Analysis Cytometry 42 2000 327-346
-
(2000)
Cytometry
, vol.42
, pp. 327-346
-
-
Brando, B.1
Barnett, D.2
Janossy, G.3
Mandy, F.4
Autran, B.5
Rothe, G.6
-
22
-
-
0028931173
-
Immunologic differentiation of absolute lymphocyte count with an integrated flow cytometric system: A new concept for absolute T cell subset determinations
-
Mercolino T.J. Connelly M.C. Meyer E.J. Knight M.D. Parker J.W. Stelzer G.T. et al. Immunologic differentiation of absolute lymphocyte count with an integrated flow cytometric system: a new concept for absolute T cell subset determinations Cytometry 22 1995 48-59
-
(1995)
Cytometry
, vol.22
, pp. 48-59
-
-
Mercolino, T.J.1
Connelly, M.C.2
Meyer, E.J.3
Knight, M.D.4
Parker, J.W.5
Stelzer, G.T.6
-
23
-
-
0042911894
-
The stability of currently used cytometers facilitates both the identification of pipetting errors and their volumetric operation: 'Time' can tell all
-
Bergeron M. Lustyik G. Ding T. Nicholson J. Janossy G. Shapiro H. et al. The stability of currently used cytometers facilitates both the identification of pipetting errors and their volumetric operation: 'time' can tell all Cytometry 52B 2003 37-40
-
(2003)
Cytometry
, vol.52 B
, pp. 37-40
-
-
Bergeron, M.1
Lustyik, G.2
Ding, T.3
Nicholson, J.4
Janossy, G.5
Shapiro, H.6
-
24
-
-
0034103226
-
Adoption of single-platform technologies for enumeration of absolute T- lymphocyte subsets in peripheral blood
-
O'Gorman M.R. Nicholson J.K. Adoption of single-platform technologies for enumeration of absolute T- lymphocyte subsets in peripheral blood Clin Diagn Lab Immunol 7 2000 333-335
-
(2000)
Clin. Diagn. Lab. Immunol.
, vol.7
, pp. 333-335
-
-
O'Gorman, M.R.1
Nicholson, J.K.2
-
26
-
-
0034020628
-
Multisite comparison of CD4 and CD8 T-lymphocyte counting by single- versus multiple-platform methodologies: Evaluation of Beckman Coulter flow-count fluorospheres and the tetraONE system
-
Reimann K.A. O'Gorman M.R. Spritzler J. Wilkening C.L. Sabath D.E. Helm K. Campbell D.E. Multisite comparison of CD4 and CD8 T-lymphocyte counting by single- versus multiple-platform methodologies: evaluation of Beckman Coulter flow-count fluorospheres and the tetraONE system Clin Diagn Lab Immunol 7 2000 344-351
-
(2000)
Clin. Diagn. Lab. Immunol.
, vol.7
, pp. 344-351
-
-
Reimann, K.A.1
O'Gorman, M.R.2
Spritzler, J.3
Wilkening, C.L.4
Sabath, D.E.5
Helm, K.6
Campbell, D.E.7
-
27
-
-
0037092125
-
Quality control of CD4+ T-lymphocyte enumeration: Results from the last 9 years of the United Kingdom National External Quality Assessment Scheme for Immune Monitoring (1993-2001)
-
Whitby L. Granger V. Storie I. Goodfellow K. Sawle A. Reilly J.T. Barnett D. Quality control of CD4+ T-lymphocyte enumeration: results from the last 9 years of the United Kingdom National External Quality Assessment Scheme for Immune Monitoring (1993-2001) Cytometry 50 2002 102-110
-
(2002)
Cytometry
, vol.50
, pp. 102-110
-
-
Whitby, L.1
Granger, V.2
Storie, I.3
Goodfellow, K.4
Sawle, A.5
Reilly, J.T.6
Barnett, D.7
-
28
-
-
0037092123
-
D45 assisted PanLeucogating for accurate, affordable dual platform CD4+ T cell enumeration
-
Glencross D.K. Scott L.E. Jani I.V. Barnett D. Janossy G. D45 assisted PanLeucogating for accurate, affordable dual platform CD4+ T cell enumeration Cytometry 50 2002 69-77
-
(2002)
Cytometry
, vol.50
, pp. 69-77
-
-
Glencross, D.K.1
Scott, L.E.2
Jani, I.V.3
Barnett, D.4
Janossy, G.5
-
29
-
-
0028931172
-
Variability in absolute lymphocyte counts obtained by automated cell counters
-
Simson E. Groner W. Variability in absolute lymphocyte counts obtained by automated cell counters Cytometry 22 1995 26-34
-
(1995)
Cytometry
, vol.22
, pp. 26-34
-
-
Simson, E.1
Groner, W.2
-
30
-
-
0032863668
-
Absolute CD4+ T-lymphocyte and CD34+ stem cell counts by single-platform flow cytometry: The way forward
-
Barnett D. Granger V. Whitby L. Storie I. Reilly J.T. Absolute CD4+ T-lymphocyte and CD34+ stem cell counts by single-platform flow cytometry: the way forward Br J Haematol 106 1999 1059-1062
-
(1999)
Br. J. Haematol.
, vol.106
, pp. 1059-1062
-
-
Barnett, D.1
Granger, V.2
Whitby, L.3
Storie, I.4
Reilly, J.T.5
-
31
-
-
0028866482
-
Standardization of absolute CD4+ lymphocyte counts across laboratories: An evaluation of the Ortho CytoronAbsolute flow cytometry system on normal donors
-
Connelly M.C. Knight M. Giorgi J.V. Kagan J. Landay A.L. Parker J.W. et al. Standardization of absolute CD4+ lymphocyte counts across laboratories: an evaluation of the Ortho CytoronAbsolute flow cytometry system on normal donors Cytometry 22 1995 200-210
-
(1995)
Cytometry
, vol.22
, pp. 200-210
-
-
Connelly, M.C.1
Knight, M.2
Giorgi, J.V.3
Kagan, J.4
Landay, A.L.5
Parker, J.W.6
-
32
-
-
84889152492
-
To bead or not to bead: Development of a flow-rate based single platform PanLeucogating protocol
-
In press
-
Storie I. Sawle A. Whitby L. Goodfellow K. Granger V. Reilly J.T. et al. To bead or not to bead: development of a flow-rate based single platform PanLeucogating protocol Cytometry 2003 In press
-
(2003)
Cytometry
-
-
Storie, I.1
Sawle, A.2
Whitby, L.3
Goodfellow, K.4
Granger, V.5
Reilly, J.T.6
-
33
-
-
0035254152
-
The "vanishing counting bead" phenomenon: Effect on absolute CD34+ cell counting in phosphate-buffered saline-diluted leukapheresis samples
-
Brando B. Gohde W.Jr. Scarpati B. D'Avanzo G. The "vanishing counting bead" phenomenon: effect on absolute CD34+ cell counting in phosphate-buffered saline-diluted leukapheresis samples Cytometry 43 2001 154-160
-
(2001)
Cytometry
, vol.43
, pp. 154-160
-
-
Brando, B.1
Gohde W., Jr.2
Scarpati, B.3
D'Avanzo, G.4
-
35
-
-
0035106311
-
Use of formalin-fixed, propidium iodide-stained human leukocytes as a standard for enumerating CD4+ T lymphocytes in a single-platform assay
-
Harrison G.M. Bennett A.J. Moody M. Read G.F. Williams P.E. Use of formalin-fixed, propidium iodide-stained human leukocytes as a standard for enumerating CD4+ T lymphocytes in a single-platform assay Clin Diagn Lab Immunol 8 2001 397-401
-
(2001)
Clin. Diagn. Lab. Immunol.
, vol.8
, pp. 397-401
-
-
Harrison, G.M.1
Bennett, A.J.2
Moody, M.3
Read, G.F.4
Williams, P.E.5
-
36
-
-
0037092177
-
Use of CD45 gating in 3 and 4-colour flow cytometric immunophenotyping: Guideline from the NIAID, Division of AIDS
-
Schnizlein-Bick C.T. Mandy F. O'Gorman M.R. Paxton H. Nicholson J. Hultin L.E. et al. Use of CD45 gating in 3 and 4-colour flow cytometric immunophenotyping: Guideline from the NIAID, Division of AIDS Cytometry 50 2002 46-52
-
(2002)
Cytometry
, vol.50
, pp. 46-52
-
-
Schnizlein-Bick, C.T.1
Mandy, F.2
O'Gorman, M.R.3
Paxton, H.4
Nicholson, J.5
Hultin, L.E.6
-
37
-
-
0037474317
-
Guidelines for performing single-platform absolute CD4+ T-cell determinations with CD45 gating for persons infected with human immunodeficiency virus
-
Centers for Disease Control and Prevention
-
Mandy F.F. Nicholson J.K. McDougal J.S. Guidelines for performing single-platform absolute CD4+ T-cell determinations with CD45 gating for persons infected with human immunodeficiency virus. Centers for Disease Control and Prevention MMWR Recomm Rep 52 RR-2 2003 1-13
-
(2003)
MMWR Recomm. Rep.
, vol.52 RR-2
, pp. 1-13
-
-
Mandy, F.F.1
Nicholson, J.K.2
McDougal, J.S.3
-
38
-
-
0034652446
-
Analyses of quality assessment studies using CD45 for gating lymphocytes for CD3(+)4(+)%
-
Gelman R. Wilkening C. Analyses of quality assessment studies using CD45 for gating lymphocytes for CD3(+)4(+)% Cytometry 42 2000 1-4
-
(2000)
Cytometry
, vol.42
, pp. 1-4
-
-
Gelman, R.1
Wilkening, C.2
-
39
-
-
0037092069
-
The selection of lymphocyte gating protocol has impact on the level of reliability of T-cell subsets in aging specimens
-
Bergeron M. Nicholson J.K. Phaneuf S. Ding T. Soucy N. Badley A. et al. The selection of lymphocyte gating protocol has impact on the level of reliability of T-cell subsets in aging specimens Clin Cytometry 50 2002 62-68
-
(2002)
Clin. Cytometry
, vol.50
, pp. 62-68
-
-
Bergeron, M.1
Nicholson, J.K.2
Phaneuf, S.3
Ding, T.4
Soucy, N.5
Badley, A.6
-
40
-
-
0036679752
-
Stabilised cellular immuno-fluorescence assay (SCIFA): CD45 expression as a calibration standard for human leukocytes
-
Bikoue A. Janossy G. Barnett D. Stabilised cellular immuno-fluorescence assay (SCIFA): CD45 expression as a calibration standard for human leukocytes J Immunol Methods 266 2002 19-32
-
(2002)
J. Immunol. Methods
, vol.266
, pp. 19-32
-
-
Bikoue, A.1
Janossy, G.2
Barnett, D.3
-
44
-
-
0038819828
-
A new no-lyse, no-wash flow-cytometric method for the determination of CD4 T cells in blood samples
-
Greve B. Cassens U. Westerberg C. Gohde W. Sibrowski W. Reichelt D. et al. A new no-lyse, no-wash flow-cytometric method for the determination of CD4 T cells in blood samples Transfus Med Hemother 30 2003 8-13
-
(2003)
Transfus. Med. Hemother.
, vol.30
, pp. 8-13
-
-
Greve, B.1
Cassens, U.2
Westerberg, C.3
Gohde, W.4
Sibrowski, W.5
Reichelt, D.6
-
45
-
-
0037092072
-
Impact of the International program for Quality assessment and standardization for immunological measures relevant to HIV/AIDS: QASI 2002
-
Mandy F. Bergeron M. Houle G. Bradley J. Fahey J.J. Impact of the International program for Quality assessment and standardization for immunological measures relevant to HIV/AIDS: QASI 2002 Clin Cytometry 50 2002 111-116
-
(2002)
Clin. Cytometry
, vol.50
, pp. 111-116
-
-
Mandy, F.1
Bergeron, M.2
Houle, G.3
Bradley, J.4
Fahey, J.J.5
-
46
-
-
0037092071
-
Grading of laboratories on CD4+ T-lymphocyte evaluations based on acceptable data boundaries defined by the measurement error
-
Kunkl A. Risso D. Terranova M.P. Girotto M. Brando B. Mortara L. et al. Grading of laboratories on CD4+ T-lymphocyte evaluations based on acceptable data boundaries defined by the measurement error Cytometry 50 2002 117-126
-
(2002)
Cytometry
, vol.50
, pp. 117-126
-
-
Kunkl, A.1
Risso, D.2
Terranova, M.P.3
Girotto, M.4
Brando, B.5
Mortara, L.6
-
47
-
-
84889140490
-
Leucocyte subset Work-programme (WP1)
-
Available at
-
Janossy G, Barnett D. 2003. Leucocyte subset Work-programme (WP1). Available at: http://www. Eurostandards.org
-
(2003)
-
-
Janossy, G.1
Barnett, D.2
-
49
-
-
0035514480
-
Affordable CD4+ T cell counts by flow cytometry: II. The use of fixed whole blood in resource-poor settings
-
Jani I.V. Janossy G. Iqbal A. Mhalu F.S. Lyamuya E.F. Biberfeld G. et al. Affordable CD4+ T cell counts by flow cytometry: II. The use of fixed whole blood in resource-poor settings J Immunol Methods 257 2001 145-154
-
(2001)
J. Immunol. Methods
, vol.257
, pp. 145-154
-
-
Jani, I.V.1
Janossy, G.2
Iqbal, A.3
Mhalu, F.S.4
Lyamuya, E.F.5
Biberfeld, G.6
-
50
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
8476
-
Bland J.M. Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement Lancet 8476 1986 307-310
-
(1986)
Lancet
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
52
-
-
1542346396
-
Multiple method comparison: A statistical model using percentage similarity
-
In press
-
Scott L.E. Galpin J.S. Glencross D.K. Multiple method comparison: a statistical model using percentage similarity Cytometry 52B 2003 In press
-
(2003)
Cytometry
, vol.52 B
-
-
Scott, L.E.1
Galpin, J.S.2
Glencross, D.K.3
-
54
-
-
3142572445
-
Performance evaluation of the FACSCount System: A dedicated system for clinical cellular analysis
-
Strauss K. Hannet I. Engels S. Shiba A. Ward D.M. Ullery S. et al. Performance evaluation of the FACSCount System: a dedicated system for clinical cellular analysis Cytometry 26 1996 52-59
-
(1996)
Cytometry
, vol.26
, pp. 52-59
-
-
Strauss, K.1
Hannet, I.2
Engels, S.3
Shiba, A.4
Ward, D.M.5
Ullery, S.6
-
55
-
-
0035818311
-
Prices of CD4 assays and viral load tests must be reduced for developing countries
-
Bartholomew C. Prices of CD4 assays and viral load tests must be reduced for developing countries BMJ 323 2001 809-810
-
(2001)
BMJ
, vol.323
, pp. 809-810
-
-
Bartholomew, C.1
-
56
-
-
84889135463
-
Less expensive CD4+ T cell monitoring using PanLeucogating
-
(Diagnosis/Laboratory Monitoring) Poster MoPeB3105 XIVth International AIDS Conference, Barcelona, Spain, 7-12 July
-
Wilja M, Janossy G, Glencross DK, Barnett D, Mermin J, Downing R. Less expensive CD4+ T cell monitoring using PanLeucogating (Diagnosis/Laboratory Monitoring) Poster MoPeB3105 XIVth International AIDS Conference, Barcelona, Spain, 7-12 July, 2002.
-
(2002)
-
-
Wilja, M.1
Janossy, G.2
Glencross, D.K.3
Barnett, D.4
Mermin, J.5
Downing, R.6
-
57
-
-
84889111647
-
New concepts in affordable CD4+ T cell enumeration for resource-poor settings
-
(AffordCD4 - 2yr Experience; Diagnosis/Laboratory Monitoring)) Poster MoPeB3220 XIVth International AIDS Conference, Barcelona, Spain, 7-12 July
-
Jani IV, Tugume SB, Bradley NJ, Pitfield T, Glencross DK, Barnett D, et al. New concepts in affordable CD4+ T cell enumeration for resource-poor settings (AffordCD4 - 2yr Experience; Diagnosis/Laboratory Monitoring)) Poster MoPeB3220 XIVth International AIDS Conference, Barcelona, Spain, 7-12 July, 2002.
-
(2002)
-
-
Jani, I.V.1
Tugume, S.B.2
Bradley, N.J.3
Pitfield, T.4
Glencross, D.K.5
Barnett, D.6
|