메뉴 건너뛰기




Volumn 38, Issue 6, 2003, Pages 311-319

Comparison of different types of blood pool agents (P792, MS325, USPIO) in a rabbit MR angiography-like protocol

Author keywords

Blood pool agent; MR angiography; MS325; P792; Rabbits; USPIO

Indexed keywords

CHELATE; GADOFOSVESET; GADOLINIUM; GADOMELITOL; GADOMER 17; GADOTERIC ACID; ULTRASMALL SUPERPARAMAGNETIC IRON OXIDE; UNCLASSIFIED DRUG;

EID: 0038778660     PISSN: 00209996     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.rli.0000066814.82006.be     Document Type: Conference Paper
Times cited : (82)

References (23)
  • 1
    • 0034762978 scopus 로고    scopus 로고
    • Coronary magnetic resonance angiography: Experimental evaluation of the new rapid clearance blood pool contrast medium P792
    • Taupitz M, Schnorr J, Wagner S, et al. Coronary magnetic resonance angiography: experimental evaluation of the new rapid clearance blood pool contrast medium P792. Magn Reson Med. 2001;46:932-938.
    • (2001) Magn Reson Med , vol.46 , pp. 932-938
    • Taupitz, M.1    Schnorr, J.2    Wagner, S.3
  • 2
    • 0033976954 scopus 로고    scopus 로고
    • Pilot MR evaluation of pharmacokinetics and relaxivity of specific blood pool agents for MR angiography
    • Marchand B, Douek P, Benderbous S, et al. Pilot MR evaluation of pharmacokinetics and relaxivity of specific blood pool agents for MR angiography. Invest Radiol. 2000;35:41-49.
    • (2000) Invest Radiol , vol.35 , pp. 41-49
    • Marchand, B.1    Douek, P.2    Benderbous, S.3
  • 4
    • 0031397830 scopus 로고    scopus 로고
    • Intravascular contrast agent improves magnetic resonance angiography of carotid arteries in minipigs
    • Lin W, Abdendschein D, Celik A, et al. Intravascular contrast agent improves magnetic resonance angiography of carotid arteries in minipigs. J Magn Reson Imaging. 1997;7:963-971.
    • (1997) J Magn Reson Imaging , vol.7 , pp. 963-971
    • Lin, W.1    Abdendschein, D.2    Celik, A.3
  • 5
    • 0031809104 scopus 로고    scopus 로고
    • Three dimensional MRI of coronary arteries using an intravascular contrast agent
    • Debiao L, Dolan R, Walovitch R, et al. Three dimensional MRI of coronary arteries using an intravascular contrast agent. Magn Reson Med. 1998;39:1014-1018.
    • (1998) Magn Reson Med , vol.39 , pp. 1014-1018
    • Debiao, L.1    Dolan, R.2    Walovitch, R.3
  • 6
    • 0034122654 scopus 로고    scopus 로고
    • Pharmacokinetics of three gadolinium chelates with different molecular sizes shortly after intravenous injection in rabbits: Relevance to MR angiography
    • Corot C, Violas X, Robert P, et al. Pharmacokinetics of three gadolinium chelates with different molecular sizes shortly after intravenous injection in rabbits: relevance to MR angiography. Invest Radiol. 2000;35:213-218.
    • (2000) Invest Radiol , vol.35 , pp. 213-218
    • Corot, C.1    Violas, X.2    Robert, P.3
  • 7
    • 0036234951 scopus 로고    scopus 로고
    • Arterial concentration profiles of two blood pool agents and Gd-DOTA after intravenous injection in rabbits
    • Corot C, Violas X, Robert P, et al. Arterial concentration profiles of two blood pool agents and Gd-DOTA after intravenous injection in rabbits. Acad Radiol. 2002;9(suppl 1):S137-S139.
    • (2002) Acad Radiol , vol.9 , Issue.SUPPL. 1
    • Corot, C.1    Violas, X.2    Robert, P.3
  • 8
    • 0038323882 scopus 로고    scopus 로고
    • Comparison of plasma and peritoneal concentrations of various categories of MRI blood pool agents in a murine experimental pharmacokinetic model
    • Bourasset F, Dencausse A, Bourrinet P, et al. Comparison of plasma and peritoneal concentrations of various categories of MRI blood pool agents in a murine experimental pharmacokinetic model. MAGMA. 2001;12: 81-87.
    • (2001) MAGMA , vol.12 , pp. 81-87
    • Bourasset, F.1    Dencausse, A.2    Bourrinet, P.3
  • 9
    • 0036210611 scopus 로고    scopus 로고
    • Safety and pharmacokinetics of P792, a new blood-pool agent: Results of clinical testing in nonpatient volunteers
    • Gaillard S, Kubiak C, Stolz C, et al. Safety and pharmacokinetics of P792, a new blood-pool agent: results of clinical testing in nonpatient volunteers. Invest Radiol. 2002;37:161-166.
    • (2002) Invest Radiol , vol.37 , pp. 161-166
    • Gaillard, S.1    Kubiak, C.2    Stolz, C.3
  • 10
    • 0034872851 scopus 로고    scopus 로고
    • Physicochemical and biological evaluation of P792, a rapid clearance blood pool agent for magnetic resonance imaging
    • Port M, Corot C, Raynal I, et al. Physicochemical and biological evaluation of P792, a rapid clearance blood pool agent for magnetic resonance imaging. Invest Radiol. 2001;36:445-454.
    • (2001) Invest Radiol , vol.36 , pp. 445-454
    • Port, M.1    Corot, C.2    Raynal, I.3
  • 11
    • 0034981660 scopus 로고    scopus 로고
    • P792: A rapid clearance blood pool agent for magnetic resonance imaging: Preliminary results
    • Port M, Corot C, Rousseaux O, et al. P792: a rapid clearance blood pool agent for magnetic resonance imaging: preliminary results. MAGMA. 2001;12:121-127.
    • (2001) MAGMA , vol.12 , pp. 121-127
    • Port, M.1    Corot, C.2    Rousseaux, O.3
  • 12
    • 0034981548 scopus 로고    scopus 로고
    • Pharmacokinetics of gadomer-17, a new dendritic magnetic resonance contrast agent
    • Misselwitz B, Schmitt-Willich H, Ebert W, et al. Pharmacokinetics of gadomer-17, a new dendritic magnetic resonance contrast agent. MAGMA. 2001;12:128-134.
    • (2001) MAGMA , vol.12 , pp. 128-134
    • Misselwitz, B.1    Schmitt-Willich, H.2    Ebert, W.3
  • 13
    • 0033625382 scopus 로고    scopus 로고
    • NC100150 injection, a preparation of optimised iron oxide nanoparticles for positive-contrast MR angiography
    • Kellar K, Fujii D, Gunther W, et al. NC100150 injection, a preparation of optimised iron oxide nanoparticles for positive-contrast MR angiography. JMRI. 2000;11:488-494.
    • (2000) JMRI , vol.11 , pp. 488-494
    • Kellar, K.1    Fujii, D.2    Gunther, W.3
  • 14
    • 5644229749 scopus 로고    scopus 로고
    • Physical, chemical and biological evaluations of CMD-A2-Gd-DOTA: A new paramagnetic polymer
    • Corot C, Schaefer M, Beauté S, et al. Physical, chemical and biological evaluations of CMD-A2-Gd-DOTA: a new paramagnetic polymer. Acta Radiol. 1997;38(suppl 412):91-99.
    • (1997) Acta Radiol , vol.38 , Issue.SUPPL. 412 , pp. 91-99
    • Corot, C.1    Schaefer, M.2    Beauté, S.3
  • 15
    • 0031836465 scopus 로고    scopus 로고
    • MS-325: Albumin-targeted contrast agent for MR angiography
    • Lauffer R, Parmelee D, Dunham S, et al. MS-325: albumin-targeted contrast agent for MR angiography. Radiology. 1998;207:529-538.
    • (1998) Radiology , vol.207 , pp. 529-538
    • Lauffer, R.1    Parmelee, D.2    Dunham, S.3
  • 16
    • 0031435887 scopus 로고    scopus 로고
    • Preclinical evaluation of the pharmacokinetics, biodistribution and elimination of MS-325, a blood pool agent for magnetic resonance imaging
    • Parmelee D, Walovitsch C, Ouellet H, et al. Preclinical evaluation of the pharmacokinetics, biodistribution and elimination of MS-325, a blood pool agent for magnetic resonance imaging. Invest Radiol. 1997;32:741-747.
    • (1997) Invest Radiol , vol.32 , pp. 741-747
    • Parmelee, D.1    Walovitsch, C.2    Ouellet, H.3
  • 17
    • 0034800815 scopus 로고    scopus 로고
    • Contrast-enhanced coronary MR angiography: Relationship between coronary artery delineation and blood T1
    • Zheng J, Cavagna F, Klocke H, et al. Contrast-enhanced coronary MR angiography: relationship between coronary artery delineation and blood T1. J Magn Reson Imaging. 2001;14:348-354.
    • (2001) J Magn Reson Imaging , vol.14 , pp. 348-354
    • Zheng, J.1    Cavagna, F.2    Klocke, H.3
  • 18
    • 0035088061 scopus 로고    scopus 로고
    • Carotid MR angiography: Phase II study of safety and efficacy for MS-325
    • Bluemke D, Stillman A, Bis K, et al. Carotid MR angiography: phase II study of safety and efficacy for MS-325. Radiology. 2001;219:114-122.
    • (2001) Radiology , vol.219 , pp. 114-122
    • Bluemke, D.1    Stillman, A.2    Bis, K.3
  • 19
    • 0031862273 scopus 로고    scopus 로고
    • Steady-state and dynamic MR angiography with MS-325: Initial experience in humans
    • Grist T, Korosec F, Peters D, et al. Steady-state and dynamic MR angiography with MS-325: initial experience in humans. Radiology. 1998;207:539-544.
    • (1998) Radiology , vol.207 , pp. 539-544
    • Grist, T.1    Korosec, F.2    Peters, D.3
  • 20
    • 0032714162 scopus 로고    scopus 로고
    • Contrast agents for magnetic resonance angiographic applications: 1H and 17O NMR relaxometric investigations on two gadolinium(III) DTPA-like chelates endowed with high binding affinity to human serum albumin
    • Aime S, Chiaussa M, Digilio G, et al. Contrast agents for magnetic resonance angiographic applications: 1H and 17O NMR relaxometric investigations on two gadolinium(III) DTPA-like chelates endowed with high binding affinity to human serum albumin. J Biol Inorg Chem. 1999;4:766-774.
    • (1999) J Biol Inorg Chem , vol.4 , pp. 766-774
    • Aime, S.1    Chiaussa, M.2    Digilio, G.3
  • 21
    • 0038904727 scopus 로고    scopus 로고
    • Physicochemical characterization of MS-325, a new gadolinium complex by multinuclear relaxometry
    • Muller R, Raduchel B, Laurent S, et al. Physicochemical characterization of MS-325, a new gadolinium complex by multinuclear relaxometry. Eur J Inorg Chem. 1999:1949-1955.
    • (1999) Eur J Inorg Chem , pp. 1949-1955
    • Muller, R.1    Raduchel, B.2    Laurent, S.3
  • 22
    • 0032932986 scopus 로고    scopus 로고
    • Benefit of T1 reduction for magnetic resonance coronary angiography: A numerical simulation and phantom study
    • Johansson L, Fischer S, Lorenz C. Benefit of T1 reduction for magnetic resonance coronary angiography: a numerical simulation and phantom study. J Magn Reson Imaging. 1999;9:552-556.
    • (1999) J Magn Reson Imaging , vol.9 , pp. 552-556
    • Johansson, L.1    Fischer, S.2    Lorenz, C.3
  • 23
    • 0033277505 scopus 로고    scopus 로고
    • Abdominal vessel enhancement with an ultrasmall, superparamagnetic iron oxide blood pool agent: Evaluation of dose and echo time dependence at different field strengths
    • Wikstrom L, Johansson L, Ericsson A, et al. Abdominal vessel enhancement with an ultrasmall, superparamagnetic iron oxide blood pool agent: evaluation of dose and echo time dependence at different field strengths. Acad Radiol. 1999;6:292-298.
    • (1999) Acad Radiol , vol.6 , pp. 292-298
    • Wikstrom, L.1    Johansson, L.2    Ericsson, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.