메뉴 건너뛰기




Volumn 13, Issue 6, 2003, Pages 1266-1276

Ferucarbotran (Resovist): A new clinically approved RES-specific contrast agent for contrast-enhanced MRI of the liver: Properties, clinical development, and applications

Author keywords

Dynamic MRI; Ferucarbotran; Lesion characterization; Liver; Low field high field; MRA; SPIO; Time window

Indexed keywords

CONTRAST MEDIUM; DEXTRO PHENYLALANYLCYSTEINYLTYROSYL DEXTRO TRYPTOPHYLARGINYLTHREONYLPENICILLAMINYLTHREONINAMIDE 2,7 DISULFIDE; GADOBENATE DIMEGLUMINE; GADOLINIUM CHELATE; MANGAFODIPIR; SH U 55A; SUPERPARAMAGNETIC IRON OXIDE; ULTRASMALL SUPERPARAMAGNETIC IRON OXIDE;

EID: 0038756705     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00330-002-1721-7     Document Type: Review
Times cited : (558)

References (48)
  • 1
    • 0031616365 scopus 로고    scopus 로고
    • Hepatic MRI with SPIO: Detection and characterization of focal liver lesions
    • Reimer P, Tombach B (1998) Hepatic MRI with SPIO: detection and characterization of focal liver lesions. Eur Radiol 8:1198-1204
    • (1998) Eur. Radiol. , vol.8 , pp. 1198-1204
    • Reimer, P.1    Tombach, B.2
  • 2
    • 0034753215 scopus 로고    scopus 로고
    • Superparamagnetic iron oxide contrast agents: Physicochemical characteristics and applications in MR imaging
    • Wang YX, Hussain SM, Krestin GP (2001) Superparamagnetic iron oxide contrast agents: physicochemical characteristics and applications in MR imaging. Eur Radiol 11:2319-2331
    • (2001) Eur. Radiol. , vol.11 , pp. 2319-2331
    • Wang, Y.X.1    Hussain, S.M.2    Krestin, G.P.3
  • 3
    • 0028020159 scopus 로고
    • Liver MR imaging with iron oxides: Toward consensus and clinical practice
    • Weissleder R (1994) Liver MR imaging with iron oxides: toward consensus and clinical practice. Radiology 193:593-595
    • (1994) Radiology , vol.193 , pp. 593-595
    • Weissleder, R.1
  • 4
    • 84869594070 scopus 로고
    • Clinical results with Resovist: A phase 2 clinical trial
    • Reimer P, Rummeny EJ, Daldrup HE et al. (1995) Clinical results with Resovist: a phase 2 clinical trial. Radiology 195:489-496
    • (1995) Radiology , vol.195 , pp. 489-496
    • Reimer, P.1    Rummeny, E.J.2    Daldrup, H.E.3
  • 5
    • 0028511368 scopus 로고
    • Contrast enhanced MR imaging of liver and spleen: First experience in humans with a new superparamagnetic iron oxide
    • Hamm B, Staks T, Taupitz M et al. (1994) Contrast enhanced MR imaging of liver and spleen: first experience in humans with a new superparamagnetic iron oxide. J Magn Reson Imaging 4:659-668
    • (1994) J. Magn. Reson. Imaging , vol.4 , pp. 659-668
    • Hamm, B.1    Staks, T.2    Taupitz, M.3
  • 7
    • 0028432559 scopus 로고
    • Phase I clinical evaluation of a new iron oxide MR contrast agent
    • McLachlan SJ, Morris MR, Lucas MA et al. (1994) Phase I clinical evaluation of a new iron oxide MR contrast agent. J Magn Reson Imaging 4:301-307
    • (1994) J. Magn. Reson. Imaging , vol.4 , pp. 301-307
    • McLachlan, S.J.1    Morris, M.R.2    Lucas, M.A.3
  • 8
    • 0024505526 scopus 로고
    • Superparamagnetic iron oxide: Pharmacokinetics and toxicity
    • Weissleder R, Stark DD, Engelstad BL et al. (1989) Superparamagnetic iron oxide: pharmacokinetics and toxicity. Am J Roentgenol 152:167-173
    • (1989) Am. J. Roentgenol. , vol.152 , pp. 167-173
    • Weissleder, R.1    Stark, D.D.2    Engelstad, B.L.3
  • 9
    • 0025017450 scopus 로고
    • Clinical application of superparamagnetic iron oxide to MR imaging of tissue perfusion in vascular liver tumors
    • Hahn PF, Stark DD, Elizondo G, Weissleder R, Saini S, Ferrucci JT (1990) Clinical application of superparamagnetic iron oxide to MR imaging of tissue perfusion in vascular liver tumors. Radiology 174:361-366
    • (1990) Radiology , vol.174 , pp. 361-366
    • Hahn, P.F.1    Stark, D.D.2    Elizondo, G.3    Weissleder, R.4    Saini, S.5    Ferrucci, J.T.6
  • 10
    • 0023801420 scopus 로고
    • Superparamagnetic iron oxide: Clinical application as a contrast agent for MR imaging of the liver
    • Stark DD, Weissleder R, Elizondo G et al. (1988) Superparamagnetic iron oxide: clinical application as a contrast agent for MR imaging of the liver. Radiology 168:297-301
    • (1988) Radiology , vol.168 , pp. 297-301
    • Stark, D.D.1    Weissleder, R.2    Elizondo, G.3
  • 11
    • 0028221216 scopus 로고
    • A new superparamagnetic iron oxide contrast agent for magnetic resonance imaging
    • Hamm B, Staks T, Taupitz M (1994) A new superparamagnetic iron oxide contrast agent for magnetic resonance imaging. Invest Radiol 29:S87-S89
    • (1994) Invest. Radiol. , vol.29
    • Hamm, B.1    Staks, T.2    Taupitz, M.3
  • 12
    • 0022628856 scopus 로고
    • Hemochromatosis: How much is too much
    • Tavill AS, Bacon BR (1986) Hemochromatosis: How much is too much. Hepatology 6:142-145
    • (1986) Hepatology , vol.6 , pp. 142-145
    • Tavill, A.S.1    Bacon, B.R.2
  • 13
    • 0022656390 scopus 로고
    • Value of hepatic iron measurments in early hemochromatosis and determination of the critical iron level associated with fibrosis
    • Bassett ML, Halliday JW, Powell LW (1986) Value of hepatic iron measurments in early hemochromatosis and determination of the critical iron level associated with fibrosis. Hepatology 6:24-29
    • (1986) Hepatology , vol.6 , pp. 24-29
    • Bassett, M.L.1    Halliday, J.W.2    Powell, L.W.3
  • 14
    • 13144261675 scopus 로고    scopus 로고
    • SPIO-enhanced 2D-TOF MR-angiography of the portal venous system: Results of an intraindividual comparison
    • Reimer P, Marx C, Rummeny EJ et al. (1997) SPIO-enhanced 2D-TOF MR-angiography of the portal venous system: results of an intraindividual comparison. J Magn Reson Imaging 7:945-949
    • (1997) J. Magn. Reson. Imaging , vol.7 , pp. 945-949
    • Reimer, P.1    Marx, C.2    Rummeny, E.J.3
  • 15
    • 0030766672 scopus 로고    scopus 로고
    • MR imaging of the liver with Resovist: Safety, efficacy and pharmacodynamic properties
    • Kopp AF, Laniado M, Dammann F et al. (1997) MR imaging of the liver with Resovist: safety, efficacy and pharmacodynamic properties. Radiology 204:749-756
    • (1997) Radiology , vol.204 , pp. 749-756
    • Kopp, A.F.1    Laniado, M.2    Dammann, F.3
  • 16
    • 0009899447 scopus 로고    scopus 로고
    • Evaluation of efficacy of Resovist in three doses for MRI of the liver: A blinded reader study
    • abstract
    • Shamsi K, Balzer T, Saini S et al. (1996) Evaluation of efficacy of Resovist in three doses for MRI of the liver: a blinded reader study [abstract]. Am J Roentgenol:43
    • (1996) Am. J. Roentgenol. , pp. 43
    • Shamsi, K.1    Balzer, T.2    Saini, S.3
  • 17
    • 0014384420 scopus 로고
    • Relationship between liver size and body size
    • DeLand FH, North WA (1968) Relationship between liver size and body size. Radiology 91:1195-1198
    • (1968) Radiology , vol.91 , pp. 1195-1198
    • DeLand, F.H.1    North, W.A.2
  • 18
    • 0034752953 scopus 로고    scopus 로고
    • Diagnostic efficacy and safety of MRI of the liver with superparamagnetic iron oxide particles (SH U 555 A)
    • Kehagias DT, Gouliamos AD, Smyrniotis V, Vlahos LJ (2001) Diagnostic efficacy and safety of MRI of the liver with superparamagnetic iron oxide particles (SH U 555 A). J Magn Reson Imaging 14:595-601
    • (2001) J. Magn. Reson. Imaging , vol.14 , pp. 595-601
    • Kehagias, D.T.1    Gouliamos, A.D.2    Smyrniotis, V.3    Vlahos, L.J.4
  • 19
    • 0034094896 scopus 로고    scopus 로고
    • Detection of focal hepatic lesions: Comparison of unenhanced and SHU 555 A-enhanced MR imaging versus biphasic helical CTAP
    • Ba-Ssalamah A, Heinz-Peer G, Schima W et al. (2000) Detection of focal hepatic lesions: comparison of unenhanced and SHU 555 A-enhanced MR imaging versus biphasic helical CTAP. J Magn Reson Imaging 11:665-672
    • (2000) J. Magn. Reson. Imaging , vol.11 , pp. 665-672
    • Ba-Ssalamah, A.1    Heinz-Peer, G.2    Schima, W.3
  • 20
    • 0034546354 scopus 로고    scopus 로고
    • Hepatic lesion detection and characterization: Value of nonenhanced MR imaging, superparamagnetic iron oxide-enhanced MR imaging, and spiral CT-ROC analysis
    • Reimer P, Jahnke N, Fiebich M et al. (2000) Hepatic lesion detection and characterization: value of nonenhanced MR imaging, superparamagnetic iron oxide-enhanced MR imaging, and spiral CT-ROC analysis. Radiology 217:152-158
    • (2000) Radiology , vol.217 , pp. 152-158
    • Reimer, P.1    Jahnke, N.2    Fiebich, M.3
  • 23
    • 0028929632 scopus 로고
    • Blood-pool MR contrast material for detection and characterization of focal hepatic lesions: Initial clinical experience with ultrasmall superparamagnetic iron oxide (AMI-227)
    • Saini S, Edelman RR, Sharma P et al. (1995) Blood-pool MR contrast material for detection and characterization of focal hepatic lesions: initial clinical experience with ultrasmall superparamagnetic iron oxide (AMI-227). Am J Roentgenol 164:1147-1152
    • (1995) Am. J. Roentgenol. , vol.164 , pp. 1147-1152
    • Saini, S.1    Edelman, R.R.2    Sharma, P.3
  • 24
    • 0031401566 scopus 로고    scopus 로고
    • Effects of AMI-25 on liver vessels and tumors on T1-weighted turbo-field-echo images: Implications for tumor characterization
    • Van Gansbeke D, Metens TM, Matos C et al. (1997) Effects of AMI-25 on liver vessels and tumors on T1-weighted turbo-field-echo images: implications for tumor characterization. J Magn Reson Imaging 7:482-489
    • (1997) J. Magn. Reson. Imaging , vol.7 , pp. 482-489
    • Van Gansbeke, D.1    Metens, T.M.2    Matos, C.3
  • 25
    • 10344235969 scopus 로고    scopus 로고
    • Magnetic resonance imaging of focal liver lesions: Comparison of the superparamagnetic iron oxide Resovist versus gadolinium-DTPA in the same patient
    • Vogl TJ, Hammerstingl R, Schwarz W et al. (1996) Magnetic resonance imaging of focal liver lesions: comparison of the superparamagnetic iron oxide Resovist versus gadolinium-DTPA in the same patient. Invest Radiol 31:696-708
    • (1996) Invest. Radiol. , vol.31 , pp. 696-708
    • Vogl, T.J.1    Hammerstingl, R.2    Schwarz, W.3
  • 27
    • 0034877607 scopus 로고    scopus 로고
    • Conspicuity of hepatocellular nodular lesions in cirrhotic livers at ferumoxides-enhanced MR imaging: Importance of Kupffer cell number
    • Lim JH, Choi D, Cho SK et al. (2001) Conspicuity of hepatocellular nodular lesions in cirrhotic livers at ferumoxides-enhanced MR imaging: importance of Kupffer cell number. Radiology 220:669-676
    • (2001) Radiology , vol.220 , pp. 669-676
    • Lim, J.H.1    Choi, D.2    Cho, S.K.3
  • 28
    • 0031672515 scopus 로고    scopus 로고
    • T1-effects of a bolus-injectable SPIO "SH U 555 A": Dependency on field strength, plasma concentration, and preliminary clinical experience with dynamic T1-weighted MRI
    • Reimer P, Müller M, Marx C et al. (1998) T1-effects of a bolus-injectable SPIO "SH U 555 A": dependency on field strength, plasma concentration, and preliminary clinical experience with dynamic T1-weighted MRI. Radiology 209:831-836
    • (1998) Radiology , vol.209 , pp. 831-836
    • Reimer, P.1    Müller, M.2    Marx, C.3
  • 29
    • 0028032591 scopus 로고
    • Enhancement of liver hemangiomas on T1-weighted MR SE images by superparamagnetic iron oxide particles
    • Grangier C, Tourniaire J, Mentha G et al. (1994) Enhancement of liver hemangiomas on T1-weighted MR SE images by superparamagnetic iron oxide particles. J Comput Assist Tomogr 18:888-896
    • (1994) J. Comput. Assist. Tomogr. , vol.18 , pp. 888-896
    • Grangier, C.1    Tourniaire, J.2    Mentha, G.3
  • 32
    • 0030068974 scopus 로고    scopus 로고
    • Ring enhancement in ultrasmall superparamagnetic iron oxide imaging: A potential new sign for characterization of liver lesions
    • Mergo PJ, Helmberger T, Nicolas AI, Ros PR (1996) Ring enhancement in ultrasmall superparamagnetic iron oxide imaging: a potential new sign for characterization of liver lesions. Am J Roentgenol 166:379-384
    • (1996) Am. J. Roentgenol. , vol.166 , pp. 379-384
    • Mergo, P.J.1    Helmberger, T.2    Nicolas, A.I.3    Ros, P.R.4
  • 33
    • 0031056877 scopus 로고    scopus 로고
    • Differentiation of liver hemangiomas from metastases and hepatocellular carcinoma at MR imaging enhanced with blood-pool contrast agent code-7227
    • Harisinghani MG, Saini S, Weissleder R et al. (1997) Differentiation of liver hemangiomas from metastases and hepatocellular carcinoma at MR imaging enhanced with blood-pool contrast agent code-7227. Radiology 202:687-691
    • (1997) Radiology , vol.202 , pp. 687-691
    • Harisinghani, M.G.1    Saini, S.2    Weissleder, R.3
  • 34
    • 0031787395 scopus 로고    scopus 로고
    • MRI in focal liver disease: A comparison of small and ultra-small superparamagnetic iron oxide as hepatic contrast agents
    • Mergo PJ, Engelken JD, Helmberger T, Ros PR (1998) MRI in focal liver disease: a comparison of small and ultra-small superparamagnetic iron oxide as hepatic contrast agents. J Magn Reson Imaging 8:1073-1078
    • (1998) J. Magn. Reson. Imaging , vol.8 , pp. 1073-1078
    • Mergo, P.J.1    Engelken, J.D.2    Helmberger, T.3    Ros, P.R.4
  • 35
    • 0036233950 scopus 로고    scopus 로고
    • Contrast-enhanced blood-pool MR angiography with optimized iron oxides: Effect of size and dose on vascular contrast enhancement in rabbits
    • Allkemper T, Bremer C, Matuszewski L, Ebert W, Reimer P (2002) Contrast-enhanced blood-pool MR angiography with optimized iron oxides: effect of size and dose on vascular contrast enhancement in rabbits. Radiology 223:432-438
    • (2002) Radiology , vol.223 , pp. 432-438
    • Allkemper, T.1    Bremer, C.2    Matuszewski, L.3    Ebert, W.4    Reimer, P.5
  • 37
    • 0032783864 scopus 로고    scopus 로고
    • Contrast-enhanced 3D-MRA of the upper abdomen with a bolus-injectable SPIO (SH U 555 A)
    • Reimer P, Allkemper T, Matuszewski L, Balzer T (1999) Contrast-enhanced 3D-MRA of the upper abdomen with a bolus-injectable SPIO (SH U 555 A). J Magn Reson Imaging 10:65-71
    • (1999) J. Magn. Reson. Imaging , vol.10 , pp. 65-71
    • Reimer, P.1    Allkemper, T.2    Matuszewski, L.3    Balzer, T.4
  • 39
    • 0029360672 scopus 로고
    • Long-circulating iron oxides for MR imaging
    • Torchilin V et al. (ed) CRC, Boca Raton, Florida
    • Weissleder R, Bogdanov A, Neuwelt E, Papisov M (1995) Long-circulating iron oxides for MR imaging. In: Torchilin V et al. (ed) Advanced drug delivery reviews. CRC, Boca Raton, Florida, pp 321-334
    • (1995) Advanced Drug Delivery Reviews , pp. 321-334
    • Weissleder, R.1    Bogdanov, A.2    Neuwelt, E.3    Papisov, M.4
  • 40
    • 0030625166 scopus 로고    scopus 로고
    • The influence of MR field strength on the detection of focal liver lesions with superparamagnetic iron oxide
    • Deckers F, Corthouts B, Nackaerts Y, Ozsarlak O, Parizel PM, De Schepper AM (1997) The influence of MR field strength on the detection of focal liver lesions with superparamagnetic iron oxide. Eur Radiol 7:887-892
    • (1997) Eur. Radiol. , vol.7 , pp. 887-892
    • Deckers, F.1    Corthouts, B.2    Nackaerts, Y.3    Ozsarlak, O.4    Parizel, P.M.5    De Schepper, A.M.6
  • 41
    • 0036340393 scopus 로고    scopus 로고
    • Evaluation of the time-window for Resovist-enhanced T2-weighted MRI of the liver
    • Reimer P, Mueller M, Marx C, Balzer T (2002) Evaluation of the time-window for Resovist-enhanced T2-weighted MRI of the liver. Acad Radiol 9 (Suppl 2):336-338
    • (2002) Acad. Radiol. , vol.9 , Issue.SUPPL. 2 , pp. 336-338
    • Reimer, P.1    Mueller, M.2    Marx, C.3    Balzer, T.4
  • 42
    • 0028577984 scopus 로고
    • Biodegradation of magnetite dextran nanoparticles in the rat: A histologic and biophysical study
    • Okon E, Pouliquen D, Okon P et al. (1994) Biodegradation of magnetite dextran nanoparticles in the rat: a histologic and biophysical study. Lab Invest 71:895-903
    • (1994) Lab. Invest. , vol.71 , pp. 895-903
    • Okon, E.1    Pouliquen, D.2    Okon, P.3
  • 43
    • 0028089212 scopus 로고
    • Enhancement of MR angiography with iron oxide: Preliminary studies in whole-blood phantom and in animals
    • Frank H, Weissleder R, Brady TJ (1994) Enhancement of MR angiography with iron oxide: preliminary studies in whole-blood phantom and in animals. Am J Roentgenol 162:209-213
    • (1994) Am. J. Roentgenol. , vol.162 , pp. 209-213
    • Frank, H.1    Weissleder, R.2    Brady, T.J.3
  • 44
    • 0025286753 scopus 로고
    • Tumor interactions with the vasculature: Angiogenesis and tumor metastasis
    • 1032
    • Blood CH, Zetter BR (1990) Tumor interactions with the vasculature: angiogenesis and tumor metastasis. Biochim Biophys Acta 1032:89-118
    • (1990) Biochim. Biophys. Acta , pp. 89-118
    • Blood, C.H.1    Zetter, B.R.2
  • 45
    • 0031421953 scopus 로고    scopus 로고
    • Assessing tumor angiogenesis using macromolecular MR imaging contrast media
    • Brasch R, Pham C, Shames D et al. (1997) Assessing tumor angiogenesis using macromolecular MR imaging contrast media. J Magn Reson Imaging 7:68-74
    • (1997) J. Magn. Reson. Imaging , vol.7 , pp. 68-74
    • Brasch, R.1    Pham, C.2    Shames, D.3
  • 46
    • 0026356319 scopus 로고
    • Rationale and applications for macromolecular Gd-based contrast agents
    • Brasch RC (1991) Rationale and applications for macromolecular Gd-based contrast agents. Magn Reson Med 22:282-287
    • (1991) Magn. Reson. Med. , vol.22 , pp. 282-287
    • Brasch, R.C.1
  • 47
    • 0030657917 scopus 로고    scopus 로고
    • Dynamic echo-planar imaging of the breast: Experience in diagnosing breast carcinoma and correlation with tumor angiogenesis
    • Hulka C, Edmister WB, Smith BL et al. (1997) Dynamic echo-planar imaging of the breast: experience in diagnosing breast carcinoma and correlation with tumor angiogenesis. Radiology 205:837-842
    • (1997) Radiology , vol.205 , pp. 837-842
    • Hulka, C.1    Edmister, W.B.2    Smith, B.L.3
  • 48
    • 0031403932 scopus 로고    scopus 로고
    • Uptake of dextran-coated monocrystalline iron oxides in tumor cells and macrophages
    • Moore A, Weissleder R, Bogdanov A Jr (1997) Uptake of dextran-coated monocrystalline iron oxides in tumor cells and macrophages. J Magn Reson Imaging 7:1140-1145
    • (1997) J. Magn. Reson. Imaging , vol.7 , pp. 1140-1145
    • Moore, A.1    Weissleder, R.2    Bogdanov A., Jr.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.