-
1
-
-
0027690838
-
Dynamic gadolinium-enhanced 3DFT abdominal MR arteriography
-
Prince M, Yucel EK, Kaufman JA, Harrison DC, Geller SC. Dynamic gadolinium-enhanced 3DFT abdominal MR arteriography. J Magn Reson Imaging 1993;3:877-881.
-
(1993)
J Magn Reson Imaging
, vol.3
, pp. 877-881
-
-
Prince, M.1
Yucel, E.K.2
Kaufman, J.A.3
Harrison, D.C.4
Geller, S.C.5
-
2
-
-
0029942854
-
Breath-hold, contrast-enhanced, three-dimensional MR angiography
-
Leung DA, McKinnon GC, Davis CP, Pfammatter T, Krestin GP, Debatin JF. Breath-hold, contrast-enhanced, three-dimensional MR angiography. Radiology 1996;200:569-571.
-
(1996)
Radiology
, vol.200
, pp. 569-571
-
-
Leung, D.A.1
McKinnon, G.C.2
Davis, C.P.3
Pfammatter, T.4
Krestin, G.P.5
Debatin, J.F.6
-
3
-
-
0028007063
-
Dynamic contrast-enhanced MR imaging of the upper abdomen: Enhancement properties of gadobutrol, gadolinlum-DTPA-polylysine, and gadolinium-DTPA-cascade-polymer
-
Adam G, Neuerburg J, Spuntrup E, Muhler A, Scherer K, Günther RW. Dynamic contrast-enhanced MR imaging of the upper abdomen: enhancement properties of gadobutrol, gadolinlum-DTPA-polylysine, and gadolinium-DTPA-cascade-polymer. Magn Reson Med 1994;32:622-628.
-
(1994)
Magn Reson Med
, vol.32
, pp. 622-628
-
-
Adam, G.1
Neuerburg, J.2
Spuntrup, E.3
Muhler, A.4
Scherer, K.5
Günther, R.W.6
-
4
-
-
0025259293
-
Evaluation of Gd-DTPA-labeled dextran as an intravascular MR contrast agent: Imaging characteristics in normal rat tissues
-
Wang SC, Wikstrom MG, White DL, et al. Evaluation of Gd-DTPA-labeled dextran as an intravascular MR contrast agent: imaging characteristics in normal rat tissues. Radiology 1990;175:483-488.
-
(1990)
Radiology
, vol.175
, pp. 483-488
-
-
Wang, S.C.1
Wikstrom, M.G.2
White, D.L.3
-
5
-
-
0028432559
-
Phase I clinical evaluation of a new iron oxide MR contrast agent
-
McLachlan SJ, Morris MR, Lucas MA, et al. Phase I clinical evaluation of a new iron oxide MR contrast agent. J Magn Reson Imaging 1994;4:301-307.
-
(1994)
J Magn Reson Imaging
, vol.4
, pp. 301-307
-
-
McLachlan, S.J.1
Morris, M.R.2
Lucas, M.A.3
-
6
-
-
0030068360
-
MR contrast material for vascular enhancement: Value of superparamagnetic iron oxide
-
Mayo-Smith WW, Saini S, Slater G, Kaufman JA, Sharma P, Hahn PF. MR contrast material for vascular enhancement: value of superparamagnetic iron oxide. AJR 1996;166:73-77.
-
(1996)
AJR
, vol.166
, pp. 73-77
-
-
Mayo-Smith, W.W.1
Saini, S.2
Slater, G.3
Kaufman, J.A.4
Sharma, P.5
Hahn, P.F.6
-
7
-
-
0031862273
-
Steady-state and dynamic MR angiography with MS-325: Initial experience in humans
-
Grist TM, Korosec FR, Peters DC, et al. Steady-state and dynamic MR angiography with MS-325: initial experience in humans. Radiology 1998;207:539-544.
-
(1998)
Radiology
, vol.207
, pp. 539-544
-
-
Grist, T.M.1
Korosec, F.R.2
Peters, D.C.3
-
8
-
-
0027173863
-
A new macromolecule as a contrast agent for MR angiography: Preparation, properties, and animal studies
-
Bogdanov AA Jr, Weissleder R, Frank H W, et al. A new macromolecule as a contrast agent for MR angiography: preparation, properties, and animal studies. Radiology 1993;187:701-706.
-
(1993)
Radiology
, vol.187
, pp. 701-706
-
-
Bogdanov A.A., Jr.1
Weissleder, R.2
Frank, H.W.3
-
9
-
-
0028020159
-
Liver MR imaging with iron oxides: Toward consensus and clinical practice
-
Weissleder R, Liver MR imaging with iron oxides: toward consensus and clinical practice. Radiology 1994;193:593-595.
-
(1994)
Radiology
, vol.193
, pp. 593-595
-
-
Weissleder, R.1
-
10
-
-
0028438220
-
Superparamagnetic iron oxide: Detection of focal liver lesions at high-field-strength MR imaging
-
Duda SH, Laniado M, Kopp AF, et al. Superparamagnetic iron oxide: Detection of focal liver lesions at high-field-strength MR imaging. J Magn Reson Imaging 1994;4:309-314.
-
(1994)
J Magn Reson Imaging
, vol.4
, pp. 309-314
-
-
Duda, S.H.1
Laniado, M.2
Kopp, A.F.3
-
11
-
-
0029151620
-
Hepatic MR imaging with ferumoxides: A multicenter clinical trial of the safety and efficacy in the detection of focal hepatic lesions
-
Ros PR, Freeny PC, Harms SE, et al. Hepatic MR imaging with ferumoxides: a multicenter clinical trial of the safety and efficacy in the detection of focal hepatic lesions. Radiology 1995;196:481-488.
-
(1995)
Radiology
, vol.196
, pp. 481-488
-
-
Ros, P.R.1
Freeny, P.C.2
Harms, S.E.3
-
12
-
-
0031056877
-
Differentiation of liver hemangiomas from metastases and hepatocellular carcinoma at MR imaging enhanced with blood-pool contrast agent code-7227
-
Harisinghani MG, Saini S, Weissleder R, et al. Differentiation of liver hemangiomas from metastases and hepatocellular carcinoma at MR imaging enhanced with blood-pool contrast agent code-7227. Radiology 1997;202:687-691.
-
(1997)
Radiology
, vol.202
, pp. 687-691
-
-
Harisinghani, M.G.1
Saini, S.2
Weissleder, R.3
-
13
-
-
0025257041
-
Ultrasmall superparamagnetic iron oxide (USPIO): Characterization of a new class of MR contrast agents
-
Weissleder R, Elizondo G, Wittenberg J, Rabito C, Bengele HH, Josephson L. Ultrasmall superparamagnetic iron oxide (USPIO): characterization of a new class of MR contrast agents. Radiology 1990;175:489-493.
-
(1990)
Radiology
, vol.175
, pp. 489-493
-
-
Weissleder, R.1
Elizondo, G.2
Wittenberg, J.3
Rabito, C.4
Bengele, H.H.5
Josephson, L.6
-
14
-
-
0028511368
-
Contrast enhanced MR imaging of liver and spleen: First experience in humans with a new superparamagnetic iron oxide
-
Hamm B, Staks T, Taupitz M, et al. Contrast enhanced MR imaging of liver and spleen: first experience in humans with a new superparamagnetic iron oxide. J Magn Reson Imaging 1994;4:659-668.
-
(1994)
J Magn Reson Imaging
, vol.4
, pp. 659-668
-
-
Hamm, B.1
Staks, T.2
Taupitz, M.3
-
15
-
-
84869594070
-
Clinical results with Resovist: A phase 2 clinical trial
-
Reimer P, Rummeny EJ, Daldrup HE, et al. Clinical results with Resovist: a phase 2 clinical trial. Radiology 1995;195:489-496.
-
(1995)
Radiology
, vol.195
, pp. 489-496
-
-
Reimer, P.1
Rummeny, E.J.2
Daldrup, H.E.3
-
16
-
-
13144261675
-
SPIO-enhanced 2D-TOF MR-angiography of the portal venous system: Results of an intraindividual comparison
-
Reimer P, Marx C, Rummeny EJ, et al. SPIO-enhanced 2D-TOF MR-angiography of the portal venous system: results of an intraindividual comparison. J Magn Reson Imaging 1997;7:945-949.
-
(1997)
J Magn Reson Imaging
, vol.7
, pp. 945-949
-
-
Reimer, P.1
Marx, C.2
Rummeny, E.J.3
-
17
-
-
0023122392
-
Albumin labeled with Gd-DTPA as an intravascular, blood pool-enhancing agent for MR imaging: Biodistribution and imaging studies
-
Schmiedl U, Ogan M, Paajanen H, et al. Albumin labeled with Gd-DTPA as an intravascular, blood pool-enhancing agent for MR imaging: biodistribution and imaging studies. Radiology 1987;162: 205-210.
-
(1987)
Radiology
, vol.162
, pp. 205-210
-
-
Schmiedl, U.1
Ogan, M.2
Paajanen, H.3
-
18
-
-
0026356319
-
Rationale and applications for macromolecular Gd-based contrast agents
-
Brasch RC. Rationale and applications for macromolecular Gd-based contrast agents. Magn Reson Med 1991;22:282-287.
-
(1991)
Magn Reson Med
, vol.22
, pp. 282-287
-
-
Brasch, R.C.1
-
19
-
-
0029360672
-
Long-circulating iron oxides for MR imaging
-
Torchilin V, et al., editors. CRC Press
-
Weissleder R, Bogdanov A, Neuwelt E, Papisov M. Long-circulating iron oxides for MR imaging. In: Torchilin V, et al., editors. Advanced drug delivery reviews. CRC Press; 1995. p 321-334.
-
(1995)
Advanced Drug Delivery Reviews
, pp. 321-334
-
-
Weissleder, R.1
Bogdanov, A.2
Neuwelt, E.3
Papisov, M.4
-
20
-
-
0031421869
-
MR imaging of pelvic lymph nodes in primary pelvic carcinoma with ultrasmall superparamagnetic iron oxide (Combidex): Preliminary observations
-
Harisinghani MG, Saini S, Slater GJ, Schnall MD, Rifkin MD. MR imaging of pelvic lymph nodes in primary pelvic carcinoma with ultrasmall superparamagnetic iron oxide (Combidex): preliminary observations. J Magn Reson Imaging 1997;7:161-163.
-
(1997)
J Magn Reson Imaging
, vol.7
, pp. 161-163
-
-
Harisinghani, M.G.1
Saini, S.2
Slater, G.J.3
Schnall, M.D.4
Rifkin, M.D.5
-
21
-
-
0025877754
-
Bone marrow: Ultrasmall superparamagnetic iron oxide for MR imaging
-
Seneterre ES, Weissleder R, Jaramillo D, et al. Bone marrow: ultrasmall superparamagnetic iron oxide for MR imaging. Radiology 1991;179:529-533.
-
(1991)
Radiology
, vol.179
, pp. 529-533
-
-
Seneterre, E.S.1
Weissleder, R.2
Jaramillo, D.3
-
22
-
-
0028437581
-
Dynamics of tumor imaging with Gd-DTPA-polyethylene glycol polymers: Dependence on molecular weight
-
Desser TS, Rubin DL, Muller HH, et al. Dynamics of tumor imaging with Gd-DTPA-polyethylene glycol polymers: dependence on molecular weight. J Magn Reson Imaging 1994;4:467-472.
-
(1994)
J Magn Reson Imaging
, vol.4
, pp. 467-472
-
-
Desser, T.S.1
Rubin, D.L.2
Muller, H.H.3
-
23
-
-
0028437704
-
Gd-DTPA-cascade-polymer: Potential blood pool contrast agent for MR imaging
-
Adam G, Neuerburg J, Spuntrup E, Muhler A, Scherer K, Günther RW. Gd-DTPA-cascade-polymer: potential blood pool contrast agent for MR imaging. J Magn Reson Imaging 1994;4:462-466.
-
(1994)
J Magn Reson Imaging
, vol.4
, pp. 462-466
-
-
Adam, G.1
Neuerburg, J.2
Spuntrup, E.3
Muhler, A.4
Scherer, K.5
Günther, R.W.6
-
24
-
-
0031836465
-
MS-325: Albumintargeted contrast agent for MR angiography
-
Lauffer RB, Parmelee DJ, Dunham SU, et al. MS-325: albumintargeted contrast agent for MR angiography. Radiology 1998;207: 529-538.
-
(1998)
Radiology
, vol.207
, pp. 529-538
-
-
Lauffer, R.B.1
Parmelee, D.J.2
Dunham, S.U.3
-
25
-
-
0025286753
-
Tumor interactions with the vasculature: Angiogenesis and tumor metastasis
-
Blood CH, Zetter BR. Tumor interactions with the vasculature: angiogenesis and tumor metastasis. Biochim Biophys Acta 1990; 1032:89-118.
-
(1990)
Biochim Biophys Acta
, vol.1032
, pp. 89-118
-
-
Blood, C.H.1
Zetter, B.R.2
-
26
-
-
0031421953
-
Assessing tumor angiogenesis using macromolecular MR imaging contrast media
-
Brasch R, Pham C, Shames D, et al. Assessing tumor angiogenesis using macromolecular MR imaging contrast media. J Magn Reson Imaging 1997;7:68-74.
-
(1997)
J Magn Reson Imaging
, vol.7
, pp. 68-74
-
-
Brasch, R.1
Pham, C.2
Shames, D.3
-
27
-
-
0030657917
-
Dynamic echo-planar imaging of the breast: Experience in diagnosing breast carcinoma and correlation with tumor angiogenesis
-
Hulka C, Edmister WB, Smith BL, et al. Dynamic echo-planar imaging of the breast: experience in diagnosing breast carcinoma and correlation with tumor angiogenesis. Radiology 1997;205:837-842.
-
(1997)
Radiology
, vol.205
, pp. 837-842
-
-
Hulka, C.1
Edmister, W.B.2
Smith, B.L.3
-
28
-
-
0031403932
-
Uptake of dextran-coated monocrystalline iron oxides in tumor cells and macrophages
-
Moore A, Weissleder R, Bogdanov A Jr. Uptake of dextran-coated monocrystalline iron oxides in tumor cells and macrophages. J Magn Reson Imaging 1997;7:1140-1145.
-
(1997)
J Magn Reson Imaging
, vol.7
, pp. 1140-1145
-
-
Moore, A.1
Weissleder, R.2
Bogdanov A., Jr.3
|