2
-
-
0016823891
-
Rate of wear in total hip replacement
-
Charnley J, Haley DK. Rate of wear in total hip replacement. ClinOrthop 1975;112:170.
-
(1975)
ClinOrthop
, vol.112
, pp. 170
-
-
Charnley, J.1
Haley, D.K.2
-
4
-
-
0027086182
-
Debris-mediated osteolysis-A cascade phenomenon involving motion, wear, particulates, macrophage induction and bone lysis
-
St John K, editor. Philadelphia: ASTM Special Technical Publications
-
Clarke IC, Campbell P, Kossovsky N. Debris-mediated osteolysis-A cascade phenomenon involving motion, wear, particulates, macrophage induction and bone lysis. In: St John K, editor. Particulate debris from medical implants. Philadelphia: ASTM Special Technical Publications; 1992. p 7-26.
-
(1992)
Particulate Debris from Medical Implants
, pp. 7-26
-
-
Clarke, I.C.1
Campbell, P.2
Kossovsky, N.3
-
5
-
-
0026660573
-
Polyethylene debris-induced osteolysis and loosening in uncemented total hip arthroplasty. A cause of late failure
-
Cooper RA, McAllister CM, Borden LS, Bauer TW. Polyethylene debris-induced osteolysis and loosening in uncemented total hip arthroplasty. A cause of late failure. J Arthroplasty 1992;7(3):285-290.
-
(1992)
J Arthroplasty
, vol.7
, Issue.3
, pp. 285-290
-
-
Cooper, R.A.1
McAllister, C.M.2
Borden, L.S.3
Bauer, T.W.4
-
6
-
-
0026662669
-
Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space
-
Schmalzried TP, Jasty M, Harris WH. Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space. J Bone Joint Surg 1992; 74A(6):849-863.
-
(1992)
J Bone Joint Surg
, vol.74 A
, Issue.6
, pp. 849-863
-
-
Schmalzried, T.P.1
Jasty, M.2
Harris, W.H.3
-
7
-
-
0029120016
-
Periprosthetic osteolysis in total hip arthroplasty: The role of particulate wear debris
-
Maloney WJ, Smith RL. Periprosthetic osteolysis in total hip arthroplasty: The role of particulate wear debris. J Bone Joint Surg 1995;77A(9):1448-1461.
-
(1995)
J Bone Joint Surg
, vol.77 A
, Issue.9
, pp. 1448-1461
-
-
Maloney, W.J.1
Smith, R.L.2
-
8
-
-
0025222261
-
Osteolysis in alloarthroplasty of the hip. The role of ultra-high molecular weight polyethylene wear particles
-
Willert HG, Bertram H, Buchhorn GH. Osteolysis in alloarthroplasty of the hip. The role of ultra-high molecular weight polyethylene wear particles. Clin Orthop 1990;258:95-107.
-
(1990)
Clin Orthop
, vol.258
, pp. 95-107
-
-
Willert, H.G.1
Bertram, H.2
Buchhorn, G.H.3
-
9
-
-
0342376968
-
Particle size versus chemical composition of biomaterials as determining factors in macrophage activation
-
Anaheim, California
-
Barth E, Sullivan T, Berg EW. Particle size versus chemical composition of biomaterials as determining factors in macrophage activation. Presented at the 37th Annual Meeting of the Orthopaedic Research Society, Anaheim, California; 1991.
-
(1991)
37th Annual Meeting of the Orthopaedic Research Society
-
-
Barth, E.1
Sullivan, T.2
Berg, E.W.3
-
10
-
-
0025412672
-
The histological effects of implantation of different sizes of polyethylene particles in the rabbit tibia
-
Goodman S, Fornasier V, Lee J, Kei J. The histological effects of implantation of different sizes of polyethylene particles in the rabbit tibia. J Biomed Mater Res 1990;24:517-524.
-
(1990)
J Biomed Mater Res
, vol.24
, pp. 517-524
-
-
Goodman, S.1
Fornasier, V.2
Lee, J.3
Kei, J.4
-
11
-
-
0026597636
-
Size of metallic and polyethylene debris particles in failed cemented total hip replacements
-
Lee J-M, Salvati EA, Betts F, DiCarlo EF, Doty SB, Bullough PG. Size of metallic and polyethylene debris particles in failed cemented total hip replacements. J Bone Joint Surg 1992;74B:380-384.
-
(1992)
J Bone Joint Surg
, vol.74 B
, pp. 380-384
-
-
Lee, J.-M.1
Salvati, E.A.2
Betts, F.3
DiCarlo, E.F.4
Doty, S.B.5
Bullough, P.G.6
-
13
-
-
0343682173
-
Radiographie measurement of long-term acetabular cup wear in vivo
-
San Francisco, California
-
Ebramzadeh E, Normand P, Elkins S, McKellop HA, Llinas A, Sarmiento A. Radiographie measurement of long-term acetabular cup wear in vivo. Presented at XVIII Annual Meeting of the Society for Biomaterials, San Francisco, California; 1995.
-
(1995)
XVIII Annual Meeting of the Society for Biomaterials
-
-
Ebramzadeh, E.1
Normand, P.2
Elkins, S.3
McKellop, H.A.4
Llinas, A.5
Sarmiento, A.6
-
14
-
-
0028818758
-
The Otto Aufranc award. Impact of gamma sterilization on clinical performance of polyethylene in the hip
-
Sutula LC, Collier JP, Saum KA, Currier BH, Currier JH, Sanford WM, Mayor MB, Wooding RE, Sperling DK, Williams IR. The Otto Aufranc Award. Impact of gamma sterilization on clinical performance of polyethylene in the hip. Clin Orthop 1995;319:28-40.
-
(1995)
Clin Orthop
, vol.319
, pp. 28-40
-
-
Sutula, L.C.1
Collier, J.P.2
Saum, K.A.3
Currier, B.H.4
Currier, J.H.5
Sanford, W.M.6
Mayor, M.B.7
Wooding, R.E.8
Sperling, D.K.9
Williams, I.R.10
-
16
-
-
0023560964
-
Effects of radiation sterilization on UHMW-polyethylene
-
Kurth M, Eyerer P, Cui D. Effects of radiation sterilization on UHMW-polyethylene. ANTEC 1987:1193-1197.
-
(1987)
ANTEC
, pp. 1193-1197
-
-
Kurth, M.1
Eyerer, P.2
Cui, D.3
-
17
-
-
0021734671
-
Radiation sterilization and the wear rate of polyethylene
-
Rose RM, Goldfarb EV, Ellis E, Crugnola AN. Radiation sterilization and the wear rate of polyethylene. J Orthop Res 1984;2(4):393-400.
-
(1984)
J Orthop Res
, vol.2
, Issue.4
, pp. 393-400
-
-
Rose, R.M.1
Goldfarb, E.V.2
Ellis, E.3
Crugnola, A.N.4
-
18
-
-
0029955320
-
Impact of gamma sterilization on clinical performance of polyethylene in the knee
-
Collier JP, Sperling DK, Currier JH, Sutula LC, Saum KA, Mayor MB. Impact of gamma sterilization on clinical performance of polyethylene in the knee J Arthroplasty 1996;11(4): 377-389.
-
(1996)
J Arthroplasty
, vol.11
, Issue.4
, pp. 377-389
-
-
Collier, J.P.1
Sperling, D.K.2
Currier, J.H.3
Sutula, L.C.4
Saum, K.A.5
Mayor, M.B.6
-
19
-
-
0030271513
-
Fatigue performance of ultra-high molecular-weight polyethylene: Effect of gamma radiation sterilization
-
Sauer WL, Weaver KD, Beals NB. Fatigue performance of ultra-high molecular-weight polyethylene: Effect of gamma radiation sterilization. Biomaterials 1996;17(20):1929-1935.
-
(1996)
Biomaterials
, vol.17
, Issue.20
, pp. 1929-1935
-
-
Sauer, W.L.1
Weaver, K.D.2
Beals, N.B.3
-
20
-
-
0031148607
-
Influence of gamma-irradiation sterilization and temperature on the fracture toughness of ultra-high molecular-weight polyethylene
-
Pascaud RS, Evans WT, McCullagh PJ, FitzPatrick DP. Influence of gamma-irradiation sterilization and temperature on the fracture toughness of ultra-high molecular-weight polyethylene. Biomaterials 1997;18(10):727-735.
-
(1997)
Biomaterials
, vol.18
, Issue.10
, pp. 727-735
-
-
Pascaud, R.S.1
Evans, W.T.2
McCullagh, P.J.3
FitzPatrick, D.P.4
-
21
-
-
0031912659
-
Quantitative comparison of wear debris from UHMWPE that has and has not been sterilised by gamma irradiation
-
Besong AA, Tipper JL, Ingham E, Stone MH, Wroblewski BM, Fisher J. Quantitative comparison of wear debris from UHMWPE that has and has not been sterilised by gamma irradiation. J Bone Joint Surg Br 1998;80(2):340-344.
-
(1998)
J Bone Joint Surg Br
, vol.80
, Issue.2
, pp. 340-344
-
-
Besong, A.A.1
Tipper, J.L.2
Ingham, E.3
Stone, M.H.4
Wroblewski, B.M.5
Fisher, J.6
-
22
-
-
0024174065
-
Ionizing irradiation for sterilization and modification of high molecular weight polyethylenes
-
Streicher RM. Ionizing irradiation for sterilization and modification of high molecular weight polyethylenes. Plast Rub Process Appl 1988;10:221-229.
-
(1988)
Plast Rub Process Appl
, vol.10
, pp. 221-229
-
-
Streicher, R.M.1
-
23
-
-
0002572722
-
Extremely low wear rate of gamma-crosslinked/remelted UHMW polyethylene acetabular cups
-
New Orleans, Louisiana; 19-21 March
-
McKellop H. Shen F-W, Salovey R. Extremely low wear rate of gamma-crosslinked/remelted UHMW polyethylene acetabular cups. Presented at the 44th Annual Meeting of the Orthopaedic Research Society, New Orleans, Louisiana; 19-21 March 1998.
-
(1998)
44th Annual Meeting of the Orthopaedic Research Society
-
-
McKellop, H.1
Shen, F.-W.2
Salovey, R.3
-
24
-
-
0002852859
-
Improving the resistance to wear and oxidation of acetabular cups of UHMWPE by gamma radiation crosslinking and remelting
-
San Diego, California
-
Shen F-WM, McKellop H, Salovey R. Improving the resistance to wear and oxidation of acetabular cups of UHMWPE by gamma radiation crosslinking and remelting. Presented at the 24th Annual Meeting of the Society for Biomaterials, San Diego, California; 1998.
-
(1998)
24th Annual Meeting of the Society for Biomaterials
-
-
Shen, F.-.W.M.1
McKellop, H.2
Salovey, R.3
-
25
-
-
0006639523
-
A new polyethylene with undetectable wear at 12 million cycles
-
San Diego, California
-
Bragdon CR, O'Connor DO, Muratoglu OK, Jasty M, Ramamurti B, Merrill E, Harris W. A new polyethylene with undetectable wear at 12 million cycles. Presented at the 24th Annual Meeting of the Society for Biomaterials, San Diego, California; 1998.
-
(1998)
24th Annual Meeting of the Society for Biomaterials
-
-
Bragdon, C.R.1
O'Connor, D.O.2
Muratoglu, O.K.3
Jasty, M.4
Ramamurti, B.5
Merrill, E.6
Harris, W.7
-
26
-
-
0000792084
-
Effect of radiation dosage on the wear of stabilized UHMWPE evaluated by hip and knee joint simulators
-
New Orleans, Louisiana; April 30-May 4
-
Wang A, Polineni VK, Essner A, Sun DC, Stark C, Dumbleton JH. Effect of radiation dosage on the wear of stabilized UHMWPE evaluated by hip and knee joint simulators. Presented at the 23rd Annual Meeting of the Society for Biomaterials, New Orleans, Louisiana; April 30-May 4, 1997.
-
(1997)
23rd Annual Meeting of the Society for Biomaterials
-
-
Wang, A.1
Polineni, V.K.2
Essner, A.3
Sun, D.C.4
Stark, C.5
Dumbleton, J.H.6
-
29
-
-
0343682167
-
International standard for plastics - Determination of matter extractable by organic solvents (conventional methods)
-
International Standard for Plastics - Determination of matter extractable by organic solvents (conventional methods); ISO 6427-1982.
-
ISO
, pp. 6427-11982
-
-
|