메뉴 건너뛰기




Volumn 104, Issue 2, 2003, Pages 151-161

Analytical analysis of a circular PZT actuator for valveless micropumps

Author keywords

Analytical analysis; MEMS; PZT actuator; Valveless micropump

Indexed keywords

COMPUTER SIMULATION; ELASTIC MODULI; FINITE ELEMENT METHOD; PIEZOELECTRIC DEVICES; POISSON RATIO; PUMPS;

EID: 0037446344     PISSN: 09244247     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0924-4247(03)00006-2     Document Type: Article
Times cited : (153)

References (21)
  • 1
    • 0031598888 scopus 로고    scopus 로고
    • A review on the modeling of piezoelectric sensors and actuators incorporated in intelligent structures
    • C.Y.K. Chee, L. Tong, G.P. Steven, A review on the modeling of piezoelectric sensors and actuators incorporated in intelligent structures, J. Intell. Mater. Syst. Struct. 9 (1998) 3-19.
    • (1998) J. Intell. Mater. Syst. Struct. , vol.9 , pp. 3-19
    • Chee, C.Y.K.1    Tong, L.2    Steven, G.P.3
  • 3
    • 0026395710 scopus 로고
    • Optimal design of piezoactuators for active noise and vibration control
    • S.J. Kim, J.D. Jones, Optimal design of piezoactuators for active noise and vibration control, AIAA J. 29 (1991) 2047-2053.
    • (1991) AIAA J. , vol.29 , pp. 2047-2053
    • Kim, S.J.1    Jones, J.D.2
  • 4
    • 0027663803 scopus 로고
    • Exact solutions for static analysis of intelligent structures
    • M.C. Ray, R. Bhattacharya, B. Samanta, Exact solutions for static analysis of intelligent structures, AIAA J. 31 (1993) 1684-1691.
    • (1993) AIAA J. , vol.31 , pp. 1684-1691
    • Ray, M.C.1    Bhattacharya, R.2    Samanta, B.3
  • 5
    • 0028448593 scopus 로고
    • Performance and optimization of induced strain actuated structures under external loading
    • Z. Chaudhry, C.A. Rogers, Performance and optimization of induced strain actuated structures under external loading, AIAA J. 32 (1994) 1289-1294.
    • (1994) AIAA J. , vol.32 , pp. 1289-1294
    • Chaudhry, Z.1    Rogers, C.A.2
  • 7
    • 0031081866 scopus 로고    scopus 로고
    • Theory of piezoelectric axisymmetric bimorph
    • A.B. Dobrucki, P. Pruchnicki, Theory of piezoelectric axisymmetric bimorph, Sens. Actuators A 58 (1997) 203-212.
    • (1997) Sens. Actuators A , vol.58 , pp. 203-212
    • Dobrucki, A.B.1    Pruchnicki, P.2
  • 10
    • 0027695246 scopus 로고
    • A valve-less diffuser/nozzle based fluid pump
    • E. Stemme, G. Stemme, A valve-less diffuser/nozzle based fluid pump, Sens. Actuators A 39 (1993) 159-167.
    • (1993) Sens. Actuators A , vol.39 , pp. 159-167
    • Stemme, E.1    Stemme, G.2
  • 11
    • 0031235285 scopus 로고    scopus 로고
    • Modeling and optimal design of piezo-electric cantilever microactuators
    • D.L. DeVoe, A.P. Pisano, Modeling and optimal design of piezo-electric cantilever microactuators, J. Microelectromech. Syst. 6 (1997) 266-270.
    • (1997) J. Microelectromech. Syst. , vol.6 , pp. 266-270
    • DeVoe, D.L.1    Pisano, A.P.2
  • 12
    • 0035368926 scopus 로고    scopus 로고
    • Surface micromachined piezoelectric accelerometers
    • D.L. DeVoe, A.P. Pisano, Surface micromachined piezoelectric accelerometers, J. Microelectromech. Syst. 10 (2001) 180-186.
    • (2001) J. Microelectromech. Syst. , vol.10 , pp. 180-186
    • DeVoe, D.L.1    Pisano, A.P.2
  • 13
    • 0032138976 scopus 로고    scopus 로고
    • Piezoceramic actuated aperture antennae
    • H.S. Yoon, G. Washington, Piezoceramic actuated aperture antennae, Smart Mater. Struct. 7 (1998) 537-542.
    • (1998) Smart Mater. Struct. , vol.7 , pp. 537-542
    • Yoon, H.S.1    Washington, G.2
  • 14
    • 0034274488 scopus 로고    scopus 로고
    • Optimization of a circular piezoelectric bimorph for a micropump driver
    • C.J. Morris, F.K. Forster, Optimization of a circular piezoelectric bimorph for a micropump driver, J. Micromech. Microeng. 10 (2000) 459-465.
    • (2000) J. Micromech. Microeng. , vol.10 , pp. 459-465
    • Morris, C.J.1    Forster, F.K.2
  • 15
    • 0035980452 scopus 로고    scopus 로고
    • Design and simulation of an implantable medical drug delivery system using microelectromechanical systems technology
    • L. Cao, S. Mantell, D. Polla, Design and simulation of an implantable medical drug delivery system using microelectromechanical systems technology, Sens. Actuators A 94 (2001) 1-9.
    • (2001) Sens. Actuators A , vol.94 , pp. 1-9
    • Cao, L.1    Mantell, S.2    Polla, D.3
  • 16
    • 0035765834 scopus 로고    scopus 로고
    • Dynamic modeling and optimization of a valveless PZT actuated micropump
    • S.F. Li, Y. Liu, S.C. Chen, Dynamic modeling and optimization of a valveless PZT actuated micropump, Proc. SPIE 4560 (2001) 67-74.
    • (2001) Proc. SPIE , vol.4560 , pp. 67-74
    • Li, S.F.1    Liu, Y.2    Chen, S.C.3
  • 17
    • 0029349922 scopus 로고
    • Working principle and performance of the dynamic micropump
    • T. Gerlach, H. Wurmus, Working principle and performance of the dynamic micropump, Sens. Actuators A 50 (1995) 135-140.
    • (1995) Sens. Actuators A , vol.50 , pp. 135-140
    • Gerlach, T.1    Wurmus, H.2
  • 18
    • 0029275289 scopus 로고
    • A valve-less planar fluid with two pump chambers
    • A. Olsson, G. Stemme, E. Stemme, A valve-less planar fluid with two pump chambers, Sens. Actuators A 46/47 (1995) 549-556.
    • (1995) Sens. Actuators A , vol.46-47 , pp. 549-556
    • Olsson, A.1    Stemme, G.2    Stemme, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.