Volumn 24, Issue 11, 2003, Pages 1925-1935

The relative influence of five variables on the in vitro wear rate of uncrosslinked UHMWPE acetabular cup liners

Author keywords

Hip joint wear simulator; In vitro wear; Ultra high molecular weight polyethylene

Indexed keywords

CORRELATION METHODS; CRYSTALLINE MATERIALS; POLYETHYLENES; SENSITIVITY ANALYSIS; WEAR OF MATERIALS;

EID: 0037400592     PISSN: 01429612     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0142-9612(02)00631-2     Document Type: Article
Times cited : (12)

References (39)
  • 1
    • 0033047781 scopus 로고    scopus 로고
    • Clinical wear of 63 ultrahigh molecular weight polyethylene acetabular components: Effect of starting resin and forming method
    • James S.P., Lee K.R., Beauregard G.P., Rentfrow E.D., McLaughlin J.R. Clinical wear of 63 ultrahigh molecular weight polyethylene acetabular components. effect of starting resin and forming method J Biomed Mater Res (Appl Biomater). 48:1999;374-384.
    • (1999) J Biomed Mater Res (Appl Biomater) , vol.48 , pp. 374-384
    • James, S.P.1    Lee, K.R.2    Beauregard, G.P.3    Rentfrow, E.D.4    McLaughlin, J.R.5
  • 2
    • 0032945469 scopus 로고    scopus 로고
    • Wear in total hip and knee replacements
    • Schmalzried T.P., Callaghan J.J. Wear in total hip and knee replacements. J Bone Jt Surg. 81-A:1999;115-136.
    • (1999) J Bone Jt Surg , vol.81 A , pp. 115-136
    • Schmalzried, T.P.1    Callaghan, J.J.2
  • 3
    • 0033972562 scopus 로고    scopus 로고
    • Design issues in clinical studies of the in vivo volumetric wear rate of polyethylene bearing components
    • Lewis G. Design issues in clinical studies of the in vivo volumetric wear rate of polyethylene bearing components. J Bone Jt Surg. 82-A:2000;281-287.
    • (2000) J Bone Jt Surg , vol.82 A , pp. 281-287
    • Lewis, G.1
  • 8
    • 0035864336 scopus 로고    scopus 로고
    • Properties of crosslinked ultra-high-molecular-weight polyethylene
    • Lewis G. Properties of crosslinked ultra-high-molecular-weight polyethylene. Biomaterials. 22:2000;371-401.
    • (2000) Biomaterials , vol.22 , pp. 371-401
    • Lewis, G.1
  • 10
    • 0027266764 scopus 로고
    • Polyethylene wear in total hip arthroplasty in patient-matched groups: A comparison of stainless steel, cobalt chromium and titanium-bearing surfaces
    • Bankston A.B., Faris P.M., Keating M., Ritter M.A. Polyethylene wear in total hip arthroplasty in patient-matched groups. a comparison of stainless steel, cobalt chromium and titanium-bearing surfaces J Arthroplasty. 8:1993;315-322.
    • (1993) J Arthroplasty , vol.8 , pp. 315-322
    • Bankston, A.B.1    Faris, P.M.2    Keating, M.3    Ritter, M.A.4
  • 11
    • 0031924305 scopus 로고    scopus 로고
    • Wear in retrieved acetabular components: Effect of femoral head radius and patient parameters
    • Elfick A.P.D., Hall R.M., Pinder I.M., Unsworth A. Wear in retrieved acetabular components: effect of femoral head radius and patient parameters. J Arthroplasty. 13:1998;291-295.
    • (1998) J Arthroplasty , vol.13 , pp. 291-295
    • Elfick, A.P.D.1    Hall, R.M.2    Pinder, I.M.3    Unsworth, A.4
  • 12
    • 0029616092 scopus 로고
    • Wear of the polyethylene acetabular cup: The effect of head material, head diameter, and cup thickness studied with a hip simulator
    • Saikko A.O. Wear of the polyethylene acetabular cup. the effect of head material, head diameter, and cup thickness studied with a hip simulator Acta Orthop Scand. 66:1995;501-506.
    • (1995) Acta Orthop Scand , vol.66 , pp. 501-506
    • Saikko, A.O.1
  • 13
    • 0035892402 scopus 로고    scopus 로고
    • Effect of counterface roughness on the wear of conventional and crosslinked ultrahigh molecular weight polyethylene studied with a multi-directional pin-on-disk device
    • Saikko V., Calonius O., Keranen J. Effect of counterface roughness on the wear of conventional and crosslinked ultrahigh molecular weight polyethylene studied with a multi-directional pin-on-disk device. J Biomed Mater Res. 57:2001;506-512.
    • (2001) J Biomed Mater Res , vol.57 , pp. 506-512
    • Saikko, V.1    Calonius, O.2    Keranen, J.3
  • 14
    • 0034142667 scopus 로고    scopus 로고
    • Wear simulation of UHMWPE for total hip replacement with a multidirectional motion pin-on-disk device: Effects of counterface material, contact area, and lubricant
    • Saikko V., Ahlroos T. Wear simulation of UHMWPE for total hip replacement with a multidirectional motion pin-on-disk device. effects of counterface material, contact area, and lubricant J Biomed Mater Res. 49:2000;147-154.
    • (2000) J Biomed Mater Res , vol.49 , pp. 147-154
    • Saikko, V.1    Ahlroos, T.2
  • 15
    • 0031099405 scopus 로고    scopus 로고
    • The significance of nonlinear motion in the wear screening of orthopaedic implant materials
    • Wang A., Polineni V.K., Essner A., Sokol M., Sun D.C., Stark C., Dumbleton J.H. The significance of nonlinear motion in the wear screening of orthopaedic implant materials. J Test Eval. 25:1997;239-245.
    • (1997) J Test Eval , vol.25 , pp. 239-245
    • Wang, A.1    Polineni, V.K.2    Essner, A.3    Sokol, M.4    Sun, D.C.5    Stark, C.6    Dumbleton, J.H.7
  • 18
    • 0034947632 scopus 로고    scopus 로고
    • Quantitative characterization of polyethylene debris isolated from periprosthetic tissue in early failure knee implants and early and late failure Charnley hip implants
    • Howling G.I., Barnet P.I., Tipper J.L., Stone M.H., Fisher J., Ingham E. Quantitative characterization of polyethylene debris isolated from periprosthetic tissue in early failure knee implants and early and late failure Charnley hip implants. J Biomed Mater Res (Appl Biomater). 58:2001;415-420.
    • (2001) J Biomed Mater Res (Appl Biomater) , vol.58 , pp. 415-420
    • Howling, G.I.1    Barnet, P.I.2    Tipper, J.L.3    Stone, M.H.4    Fisher, J.5    Ingham, E.6
  • 21
    • 0029255360 scopus 로고
    • Wear mechanisms of UHMWPE in total joint replacements
    • Wang A., Sun D.C., Stark C., Dumbleton J.H. Wear mechanisms of UHMWPE in total joint replacements. Wear. 181-183:1995;241-249.
    • (1995) Wear , vol.183 , pp. 241-249
    • Wang, A.1    Sun, D.C.2    Stark, C.3    Dumbleton, J.H.4
  • 26
    • 0035235398 scopus 로고    scopus 로고
    • Effect of contact stress on friction and wear of ultra-high molecular weight polyethylene in total hip replacement
    • Wang A., Essner A., Klein R. Effect of contact stress on friction and wear of ultra-high molecular weight polyethylene in total hip replacement. Proc Inst Mech Eng. 215(Part H):2001;133-139.
    • (2001) Proc Inst Mech Eng , vol.215 , Issue.PART H , pp. 133-139
    • Wang, A.1    Essner, A.2    Klein, R.3
  • 27
    • 0012131257 scopus 로고    scopus 로고
    • ASTM Standard D 638-00, Standard test method for tensile properties of plastics
    • West Conshohocken, PA, USA: ASTM
    • American Society for Testing and Materials (ASTM) International. ASTM Standard D 638-00, Standard test method for tensile properties of plastics, 2001 Annual Book of ASTM Standards, Vol. 08.01, Plastics (I): D 256-D 2343. West Conshohocken, PA, USA: ASTM, 2001. p. 44-56.
    • (2001) 2001 Annual Book of ASTM Standards, Vol. 08.01, Plastics (I): D 256-D 2343 , pp. 44-56
  • 28
    • 0001850790 scopus 로고
    • Alramarraie, the physical constants of polyethylene
    • J. Brandrup, & E.H. Immerguth. New York, NY, USA: Wiley
    • Quirk R.P. Alramarraie, the physical constants of polyethylene. Brandrup J., Immerguth E.H. Polymer Handbook. 1989;V-23 Wiley, New York, NY, USA.
    • (1989) Polymer Handbook , pp. 23
    • Quirk, R.P.1
  • 29
    • 0012130453 scopus 로고    scopus 로고
    • ASTM Standard D 1505-98, Standard test method for density of plastics by the density-gradient technique
    • West Conshohocken, PA, USA: ASTM
    • American Society for Testing and Materials (ASTM) International. ASTM Standard D 1505-98, Standard test method for density of plastics by the density-gradient technique, 2001 Annual Book of ASTM Standards, Vol. 08.01, Plastics (I): D 256 - D 2343. West Conshohocken, PA, USA: ASTM, 2001. p. 309-15.
    • (2001) 2001 Annual Book of ASTM Standards, Vol. 08.01, Plastics (I): D 256 - D 2343 , pp. 309-315
  • 30
    • 0033065656 scopus 로고    scopus 로고
    • Effect of molecular weight, calcium state, and sterilization methods on the wear of ultra high molecular weight polyethylene acetabular cups in a hip joint simulator
    • McKellop H.A., Shen F.-.W., Campbell P., Ota T. Effect of molecular weight, calcium state, and sterilization methods on the wear of ultra high molecular weight polyethylene acetabular cups in a hip joint simulator. J Orthop Res. 17:1999;329-339.
    • (1999) J Orthop Res , vol.17 , pp. 329-339
    • McKellop, H.A.1    Shen, F.-W.2    Campbell, P.3    Ota, T.4
  • 34
    • 0030388344 scopus 로고    scopus 로고
    • A simple method for assessing the third-body abrasive wear resistance of UHMWPE in a hip joint wear simulator
    • Congress, Toronto, Canada, May 29-June 2
    • Polineni VK, Wang A, Stark C, Dumbleton JH. A simple method for assessing the third-body abrasive wear resistance of UHMWPE in a hip joint wear simulator. Transactions of the Fifth Biomaterials Congress, Toronto, Canada, May 29-June 2, 1996. p. 872.
    • (1996) Transactions of the Fifth Biomaterials , pp. 872
    • Polineni, V.K.1    Wang, A.2    Stark, C.3    Dumbleton, J.H.4
  • 35
    • 0032664065 scopus 로고    scopus 로고
    • Predicting the clinical wear of orthopaedic bearing surfaces
    • Jacobs JJ, Craig TL, editors. West Conshohocken, PA, USA: American Society for Testing and Materials
    • Sauer W, Anthony ME. Predicting the clinical wear of orthopaedic bearing surfaces. In: Jacobs JJ, Craig TL, editors. Alternative bearing surfaces in total joint replacement. ASTM STP 1346. West Conshohocken, PA, USA: American Society for Testing and Materials, 1998, p. 1-29.
    • (1998) Alternative bearing surfaces in total joint replacement. ASTM STP 1346 , pp. 1-29
    • Sauer, W.1    Anthony, M.E.2
  • 37
    • 0035228123 scopus 로고    scopus 로고
    • Improved mathematical model of the wear of the cup articular surface in hip joint prostheses and comparison with retrieved components
    • Raimondi M.T., Santambrogio C., Pietrabissa R., Rafelini F., Molfetta L. Improved mathematical model of the wear of the cup articular surface in hip joint prostheses and comparison with retrieved components. Proc Inst Mech Eng. 215(Part H):2001;377-391.
    • (2001) Proc Inst Mech Eng , vol.215 , Issue.PART H , pp. 377-391
    • Raimondi, M.T.1    Santambrogio, C.2    Pietrabissa, R.3    Rafelini, F.4    Molfetta, L.5
  • 38
    • 0030388344 scopus 로고    scopus 로고
    • A simple method of assessing third-body abrasive wear resistance of UHMWPE in a hip joint wear simulator
    • Congress, Toronto, Canada, May 29-June 2
    • Polineni VK, Wang A, Stark C, Dumbleton JH. A simple method of assessing third-body abrasive wear resistance of UHMWPE in a hip joint wear simulator. Transactions of the Fifth World Biomaterials Congress, Toronto, Canada, May 29-June 2, 1996. p. 872.
    • (1996) Transactions of the Fifth World Biomaterials , pp. 872
    • Polineni, V.K.1    Wang, A.2    Stark, C.3    Dumbleton, J.H.4
  • 39
    • 0035175940 scopus 로고    scopus 로고
    • Relationship between gravimetric wear and particle generation in hip simulators: Conventional compared with cross-linked polyethylene
    • Ries M.D., Scott M.L., Jani S. Relationship between gravimetric wear and particle generation in hip simulators. conventional compared with cross-linked polyethylene J Bone Jt Surg. 83-A(Suppl 3, Part 1):2001;116-122.
    • (2001) J Bone Jt Surg , vol.83 A , Issue.SUPPL. 3 PART 1 , pp. 116-122
    • Ries, M.D.1    Scott, M.L.2    Jani, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.