-
1
-
-
0029949356
-
PicoGreen® quantitation of DNA: Effective evaluation of samples pre- or post-PCR
-
Ahn, S.J., J. Costa, and J.R. Emanuel. 1996. PicoGreen® quantitation of DNA: effective evaluation of samples pre- or post-PCR. Nucleic Acid Res. 24:2623-2625.
-
(1996)
Nucleic Acid Res.
, vol.24
, pp. 2623-2625
-
-
Ahn, S.J.1
Costa, J.2
Emanuel, J.R.3
-
2
-
-
0026092321
-
A human specific subfamily of Alu sequences
-
Batzer, M.A. and P.L. Deininger. 1991. A human specific subfamily of Alu sequences. Genomics 9:481-487.
-
(1991)
Genomics
, vol.9
, pp. 481-487
-
-
Batzer, M.A.1
Deininger, P.L.2
-
3
-
-
0035097948
-
Using a CCD camera imaging system as a recording device to quantify human DNA by slot blot hybridization
-
Budowle, B., W.R. Hudlow, S.B. Lee, and L. Klevan. 2001. Using a CCD camera imaging system as a recording device to quantify human DNA by slot blot hybridization. BioTechniques 30:680-685.
-
(2001)
BioTechniques
, vol.30
, pp. 680-685
-
-
Budowle, B.1
Hudlow, W.R.2
Lee, S.B.3
Klevan, L.4
-
4
-
-
0028788799
-
Investigation of species specificity using nine PCR based human STR systems
-
Crouse, C.A. and J. Schumm. 1995. Investigation of species specificity using nine PCR based human STR systems. J. Forensic Sci. 40:952-956.
-
(1995)
J. Forensic Sci.
, vol.40
, pp. 952-956
-
-
Crouse, C.A.1
Schumm, J.2
-
5
-
-
0035187195
-
NIST mixed stain studies #1 and #2: Interlaboratory comparison of DNA quantification practice and short tandem repeat multiplex performance with multiple-source samples
-
Duewer, D.L., M.C. Kline, J.W. Redman, P.J. Newall, and D.J. Reeder. 2001. NIST mixed stain studies #1 and #2: interlaboratory comparison of DNA quantification practice and short tandem repeat multiplex performance with multiple-source samples. J. Forensic Sci. 46:1199-1210.
-
(2001)
J. Forensic Sci.
, vol.46
, pp. 1199-1210
-
-
Duewer, D.L.1
Kline, M.C.2
Redman, J.W.3
Newall, P.J.4
Reeder, D.J.5
-
6
-
-
0034743908
-
Validation of the AmpFLSTR Profiler Plus™ PCR amplification kit for use in forensic casework
-
Frank, W.E., B.E. Llewellyn, P.A. Fish, A.K. Riech, T.L. Marcacci, D.W. Gandor, D. Parker, R.R. Carter, et al. 2001. Validation of the AmpFLSTR Profiler Plus™ PCR amplification kit for use in forensic casework. J. Forensic Sci. 46:642-646.
-
(2001)
J. Forensic Sci.
, vol.46
, pp. 642-646
-
-
Frank, W.E.1
Llewellyn, B.E.2
Fish, P.A.3
Riech, A.K.4
Marcacci, T.L.5
Gandor, D.W.6
Parker, D.7
Carter, R.R.8
-
7
-
-
0032988297
-
The use of mitochondrial DNA and short tandem repeat typing in the identification of air crash victims
-
Goodwin, W., A. Linacre, and P. Vanezis. 1999. The use of mitochondrial DNA and short tandem repeat typing in the identification of air crash victims. Electrophoresis 20:1707-1711.
-
(1999)
Electrophoresis
, vol.20
, pp. 1707-1711
-
-
Goodwin, W.1
Linacre, A.2
Vanezis, P.3
-
8
-
-
0034030354
-
Validation of the PowerPlex® 1.1 loci for use in human identification
-
Greenspoon, S.A., P.J. Lytle, S.A. Turek, J.M. Rolands, M.A. Scarpetta, and M.A. Carr. 2000. Validation of the PowerPlex® 1.1 loci for use in human identification. J. Forensic Sci. 45:677-683.
-
(2000)
J. Forensic Sci.
, vol.45
, pp. 677-683
-
-
Greenspoon, S.A.1
Lytle, P.J.2
Turek, S.A.3
Rolands, J.M.4
Scarpetta, M.A.5
Carr, M.A.6
-
9
-
-
0030792979
-
Rapid quantification of DNA samples extracted from buccal scrapes prior to DNA profiling
-
Hopwood, A., N. Oldroyd, S. Fellows, R. Ward, S.A. Owen, and K. Sullivan. 1997. Rapid quantification of DNA samples extracted from buccal scrapes prior to DNA profiling. BioTechniques 23:18-20.
-
(1997)
BioTechniques
, vol.23
, pp. 18-20
-
-
Hopwood, A.1
Oldroyd, N.2
Fellows, S.3
Ward, R.4
Owen, S.A.5
Sullivan, K.6
-
10
-
-
0035180791
-
TWGDAM validation of the AmpF1STR Profiler Plus™ and AmpFLSTR Cofiler™ STR multiplex systems using capillary electrophoresis
-
LaFountain, M.J., M.B. Schwartz, P.A. Svete, M.A. Walkinshaw, and E. Buel. 2001. TWGDAM validation of the AmpF1STR Profiler Plus™ and AmpFLSTR Cofiler™ STR multiplex systems using capillary electrophoresis. J. Forensic Sci. 46:1191-1198.
-
(2001)
J. Forensic Sci.
, vol.46
, pp. 1191-1198
-
-
LaFountain, M.J.1
Schwartz, M.B.2
Svete, P.A.3
Walkinshaw, M.A.4
Buel, E.5
-
11
-
-
8944263310
-
Validation of multiplex polymorphic STR amplification sets developed for personal identification applications
-
Micka, K.A., C.J. Sprecher, A.M. Lins, C.T. Comey, B.W. Coons, C. Crouse, D. Endean, K. Pirelli, et al. 1996. Validation of multiplex polymorphic STR amplification sets developed for personal identification applications. J. Forensic Sci. 41:582-590.
-
(1996)
J. Forensic Sci.
, vol.41
, pp. 582-590
-
-
Micka, K.A.1
Sprecher, C.J.2
Lins, A.M.3
Comey, C.T.4
Coons, B.W.5
Crouse, C.6
Endean, D.7
Pirelli, K.8
-
12
-
-
0032740238
-
TWG-DAM validation of a nine-locus and a four-locus fluorescent STR multiplex system
-
Micka, K.A., E.A. Amiott, T.L. Hockenberry, C.J. Sprecher, A.M. Lins, D.R. Rabbach, J.A. Taylor, J.W. Bacher, et al. 1999. TWG-DAM validation of a nine-locus and a four-locus fluorescent STR multiplex system. J. Forensic Sci. 44:1243-1257.
-
(1999)
J. Forensic Sci.
, vol.44
, pp. 1243-1257
-
-
Micka, K.A.1
Amiott, E.A.2
Hockenberry, T.L.3
Sprecher, C.J.4
Lins, A.M.5
Rabbach, D.R.6
Taylor, J.A.7
Bacher, J.W.8
-
13
-
-
0345889982
-
-
Product Information, Molecular Probes, Eugene, OR
-
Molecular Probes. 2000. PicoGreen® dsDNA Quantitation Reagent and Kits. Product Information, Molecular Probes, Eugene, OR.
-
(2000)
PicoGreen® dsDNA Quantitation Reagent and Kits
-
-
-
14
-
-
0346520868
-
-
Product Information, Molecular Probes, Eugene, OR
-
Molecular Probes. 2000. SYBR® Green I Nucleic Acid Gel Stain. Product Information, Molecular Probes, Eugene, OR.
-
(2000)
SYBR® Green I Nucleic Acid Gel Stain
-
-
-
15
-
-
0034990151
-
Validation of short tandem repeats (STRs) for forensic usage: Performance testing of fluorescent multiplex STR systems and analysis of authentic and simulated forensic samples
-
Moretti, T.R., A.L. Baumstark, D.A. Defenbaugh, K.M. Keyes, J.B. Smerick, and B. Budowle. 2001. Validation of short tandem repeats (STRs) for forensic usage: performance testing of fluorescent multiplex STR systems and analysis of authentic and simulated forensic samples. J. Forensic Sci. 46:647-660.
-
(2001)
J. Forensic Sci.
, vol.46
, pp. 647-660
-
-
Moretti, T.R.1
Baumstark, A.L.2
Defenbaugh, D.A.3
Keyes, K.M.4
Smerick, J.B.5
Budowle, B.6
-
16
-
-
0347781262
-
-
Product Information, Perkin Elmer Life Sciences, Gaithersburg, MD
-
Perkin Elmer Life Sciences. 1996. Quanti-Blot™ Human DNA Quantitation Kit. Product Information, Perkin Elmer Life Sciences, Gaithersburg, MD.
-
(1996)
Quanti-Blot™ Human DNA Quantitation Kit
-
-
-
17
-
-
0034021422
-
Optimal use of the fluorescent PicoGreen® dye for quantitative analysis of amplified polymerase chain reaction products on microplate
-
Romppanen, E.L., K. Savolainen, and I. Mononen. 2000. Optimal use of the fluorescent PicoGreen® dye for quantitative analysis of amplified polymerase chain reaction products on microplate. Anal. Biochem. 279:111-114.
-
(2000)
Anal. Biochem.
, vol.279
, pp. 111-114
-
-
Romppanen, E.L.1
Savolainen, K.2
Mononen, I.3
-
18
-
-
0036108473
-
A more sensitive method for the quantitation of genomic DNA by Alu amplification
-
Sifts, M.E., K. Both, and L.A. Burgoyne. 2002. A more sensitive method for the quantitation of genomic DNA by Alu amplification. J. Forensic Sci. 47:589-592.
-
(2002)
J. Forensic Sci.
, vol.47
, pp. 589-592
-
-
Sifts, M.E.1
Both, K.2
Burgoyne, L.A.3
-
19
-
-
0031194671
-
Characterization of Pico-Green® reagent and development of a fluorescence-based solution assay for double stranded DNA quantitation
-
Singer, V.L., L.J. Jones, S.T. Yue, and R.P. Haugland. 1997. Characterization of Pico-Green® reagent and development of a fluorescence-based solution assay for double stranded DNA quantitation. Anal. Biochem. 249:228-238.
-
(1997)
Anal. Biochem.
, vol.249
, pp. 228-238
-
-
Singer, V.L.1
Jones, L.J.2
Yue, S.T.3
Haugland, R.P.4
-
20
-
-
0034743529
-
Comparison of PowerPlex® 16, PowerPlex® 1.1/2.1 and ABI AmpF1STR Profiler Plus™/COfiler™ for forensic use
-
Tomsey, C.S., M. Kurtz, F. Kist, M. Hockensmith, and P. Call. 2001. Comparison of PowerPlex® 16, PowerPlex® 1.1/2.1 and ABI AmpF1STR Profiler Plus™/COfiler™ for forensic use. Croat. Med. J. 42:239-243.
-
(2001)
Croat. Med. J.
, vol.42
, pp. 239-243
-
-
Tomsey, C.S.1
Kurtz, M.2
Kist, F.3
Hockensmith, M.4
Call, P.5
-
21
-
-
0033740048
-
A systematic and quantitative analysis of PCR template contamination
-
Urban, C., F. Gruber, M. Kundi, F.G. Falkner, F. Dorner, and T. Hammerle. 2000. A systematic and quantitative analysis of PCR template contamination. J. Forensic Sci. 45:1307-1311.
-
(2000)
J. Forensic Sci.
, vol.45
, pp. 1307-1311
-
-
Urban, C.1
Gruber, F.2
Kundi, M.3
Falkner, F.G.4
Dorner, F.5
Hammerle, T.6
-
22
-
-
0014271313
-
Automated systems for the fluorometric determination of nucleic acids by the ethidium bromide technique
-
Van Dyke, K. and C. Szustkiewicz. 1968. Automated systems for the fluorometric determination of nucleic acids by the ethidium bromide technique. Anal. Biochem. 23:109-116.
-
(1968)
Anal. Biochem.
, vol.23
, pp. 109-116
-
-
Van Dyke, K.1
Szustkiewicz, C.2
-
23
-
-
0032805947
-
A quantitative fluorescence-based microplate assay for the determination of doubled stranded DNA using SYBR® green I and a standard ultraviolet transilluminator gel imaging system
-
Vitzthum, F., G. Geiger, H. Bisswanger, H. Brunner, and J. Bernhagen. 1999. A quantitative fluorescence-based microplate assay for the determination of doubled stranded DNA using SYBR® green I and a standard ultraviolet transilluminator gel imaging system. Anal. Biochem. 276:59-64.
-
(1999)
Anal. Biochem.
, vol.276
, pp. 59-64
-
-
Vitzthum, F.1
Geiger, G.2
Bisswanger, H.3
Brunner, H.4
Bernhagen, J.5
-
24
-
-
0026670282
-
A rapid chemiluminescent method for quantification of human DNA
-
Walsh, P.S., J. Varlaro, and R. Reynolds. 1992. A rapid chemiluminescent method for quantification of human DNA. Nucleic Acids Res. 20:5061-5065.
-
(1992)
Nucleic Acids Res.
, vol.20
, pp. 5061-5065
-
-
Walsh, P.S.1
Varlaro, J.2
Reynolds, R.3
-
25
-
-
0024462635
-
A simple and sensitive method for quantifying human genomic DNA in forensic specimen extracts
-
Waye, J.S., L.A. Presley, B. Budowle, G.G. Shutler, and R.M. Fourney. 1989. A simple and sensitive method for quantifying human genomic DNA in forensic specimen extracts. BioTechniques 7:852-855.
-
(1989)
BioTechniques
, vol.7
, pp. 852-855
-
-
Waye, J.S.1
Presley, L.A.2
Budowle, B.3
Shutler, G.G.4
Fourney, R.M.5
|