1
-
-
0027247911
-
Current concepts in orthopaedic biomaterials and implant fixation
-
Friedmen RJ, Black CJ, Galante JO, et al: Current concepts in orthopaedic biomaterials and implant fixation. J Bone Joint Surg Am 75:1086, 1993
-
(1993)
J Bone Joint Surg Am
, vol.75
, pp. 1086
-
-
Friedmen, R.J.1
Black, C.J.2
Galante, J.O.3
-
3
-
-
0027670415
-
Clinical reviews: Participate debris and failure of total hip replacements
-
Jasty M: Clinical reviews: participate debris and failure of total hip replacements. J Appl Biomater 4:273, 1993
-
(1993)
J Appl Biomater
, vol.4
, pp. 273
-
-
Jasty, M.1
-
4
-
-
0023890926
-
Metallic wear in failed titanium alloy total hip replacements: A histological and qualitative analysis
-
Agins HJ, Alcock NW, Bansal M, et al: Metallic wear in failed titanium alloy total hip replacements: a histological and qualitative analysis. J Bone Joint Surg Am 70:347, 1988
-
(1988)
J Bone Joint Surg Am
, vol.70
, pp. 347
-
-
Agins, H.J.1
Alcock, N.W.2
Bansal, M.3
-
5
-
-
0025137538
-
Metallosis associated with a stable titanium-alloy femoral component in total hip replacement
-
Black J, Sherk H, Bonini J, et al: Metallosis associated with a stable titanium-alloy femoral component in total hip replacement. J Bone Joint Surg Am 72:126, 1990
-
(1990)
J Bone Joint Surg Am
, vol.72
, pp. 126
-
-
Black, J.1
Sherk, H.2
Bonini, J.3
-
6
-
-
0020576705
-
The synovial like membrane at the cement interface in loose total hip replacements and its proposed role in bone lysis
-
Goldring SR, Schiller AL, Roelke M, et al: The synovial like membrane at the cement interface in loose total hip replacements and its proposed role in bone lysis. J Bone Joint Surg Am 65:575, 1983
-
(1983)
J Bone Joint Surg Am
, vol.65
, pp. 575
-
-
Goldring, S.R.1
Schiller, A.L.2
Roelke, M.3
-
7
-
-
0023719883
-
The effects of bulk versus particulate polymethylmethacrylate on bone
-
Goodman SB, Fornasier VL, Kei K: The effects of bulk versus particulate polymethylmethacrylate on bone. Clin Orthop 232:255, 1988
-
(1988)
Clin Orthop
, vol.232
, pp. 255
-
-
Goodman, S.B.1
Fornasier, V.L.2
Kei, K.3
-
8
-
-
0024272042
-
Femoral lysis after cemented hip arthroplasty
-
Huddleston HD: Femoral lysis after cemented hip arthroplasty. J Arthroplasty 3:285, 1988
-
(1988)
J Arthroplasty
, vol.3
, pp. 285
-
-
Huddleston, H.D.1
-
9
-
-
0025134979
-
Bone lysis in well fixed cemented femoral components
-
Maloney WJ, Jasty M, Rosenberg A, Harris W: Bone lysis in well fixed cemented femoral components. J Bone Joint Surg Br 72:966, 1992
-
(1992)
J Bone Joint Surg Br
, vol.72
, pp. 966
-
-
Maloney, W.J.1
Jasty, M.2
Rosenberg, A.3
Harris, W.4
-
10
-
-
0025047558
-
Localised endosteal bone lysis in relation to femoral components of cemented total hip arthroplasties
-
Anthony PP, Gie GA, Howie CR, Ling RS: Localised endosteal bone lysis in relation to femoral components of cemented total hip arthroplasties. J Bone Joint Surg Br 72:971, 1990
-
(1990)
J Bone Joint Surg Br
, vol.72
, pp. 971
-
-
Anthony, P.P.1
Gie, G.A.2
Howie, C.R.3
Ling, R.S.4
-
11
-
-
0028820598
-
Measurement of acetabular wear using a new 3 dimensional technique
-
Devane P, Bourne RB, Rorabeck CH, et al: Measurement of acetabular wear using a new 3 dimensional technique. Clin Orthop 319:303, 1995
-
(1995)
Clin Orthop
, vol.319
, pp. 303
-
-
Devane, P.1
Bourne, R.B.2
Rorabeck, C.H.3
-
12
-
-
0021992636
-
Osteolytic changes in the upper femoral shaft following porous coated hip replacement
-
Drown IW, Ring PA: Osteolytic changes in the upper femoral shaft following porous coated hip replacement. J Bone Joint Surg Br 67:218, 1985
-
(1985)
J Bone Joint Surg Br
, vol.67
, pp. 218
-
-
Drown, I.W.1
Ring, P.A.2
-
13
-
-
0026795148
-
Osteolytic cyst like area associated with polyethylene and metallic debris after total knee replacement with a vitallium prosthesis: A case report
-
Gross TP, Lennox DW: Osteolytic cyst like area associated with polyethylene and metallic debris after total knee replacement with a vitallium prosthesis: a case report. J Bone Joint Surg Am 74:1096, 1992
-
(1992)
J Bone Joint Surg Am
, vol.74
, pp. 1096
-
-
Gross, T.P.1
Lennox, D.W.2
-
14
-
-
0025126478
-
Endosteal erosion in association with stable uncemented femoral components
-
Maloney WJ, Jasty M, Harris WH, et al: Endosteal erosion in association with stable uncemented femoral components. J Bone Joint Surg Am 72:1025, 1990
-
(1990)
J Bone Joint Surg Am
, vol.72
, pp. 1025
-
-
Maloney, W.J.1
Jasty, M.2
Harris, W.H.3
-
15
-
-
0026784175
-
Osteolysis after total knee arthroplasty without cement
-
Peter PC Jr, Engh GA, Dwyer LA, Vinh TN: Osteolysis after total knee arthroplasty without cement. J Bone Joint Surg Am 74:864, 1992
-
(1992)
J Bone Joint Surg Am
, vol.74
, pp. 864
-
-
Peter Jr., P.C.1
Engh, G.A.2
Dwyer, L.A.3
Vinh, T.N.4
-
16
-
-
0025107603
-
Aggressive granulomatous lesions in cementless total hip arthroplasty
-
Santavirta S, Hoikka V, Eskola A, et al: Aggressive granulomatous lesions in cementless total hip arthroplasty. J Bone Joint Surg Br 72:980, 1990
-
(1990)
J Bone Joint Surg Br
, vol.72
, pp. 980
-
-
Santavirta, S.1
Hoikka, V.2
Eskola, A.3
-
17
-
-
0020616894
-
Localized bone resorption in the femur in mechanical failure of cemented total hip arthroplasties
-
Carlsson AS, Gentz CF, Linder L: Localized bone resorption in the femur in mechanical failure of cemented total hip arthroplasties. Acta Orthop Scand 54:396, 1983
-
(1983)
Acta Orthop Scand
, vol.54
, pp. 396
-
-
Carlsson, A.S.1
Gentz, C.F.2
Linder, L.3
-
18
-
-
0023860303
-
A rat model of bone at the cement-bone interface in the presence of polyethylene wear particles
-
Howie DW, Vernon-Roberts B, Oakeshott R, Monthey B: A rat model of bone at the cement-bone interface in the presence of polyethylene wear particles. J Bone Joint Surg Am 70:257, 1988
-
(1988)
J Bone Joint Surg Am
, vol.70
, pp. 257
-
-
Howie, D.W.1
Vernon-Roberts, B.2
Oakeshott, R.3
Monthey, B.4
-
19
-
-
0023147355
-
Foreign body reaction to polymeric debris following total hip arthroplasty
-
Maguire JK Jr, Coscia MF, Lynch MH: Foreign body reaction to polymeric debris following total hip arthroplasty. Clin Orthop 216:213, 1987
-
(1987)
Clin Orthop
, vol.216
, pp. 213
-
-
Maguire Jr., J.K.1
Coscia, M.F.2
Lynch, M.H.3
-
20
-
-
0021801523
-
Focal lytic lesions associated with stem loosening in total hip prosthesis
-
Scott WW Jr, Riley LH Jr, Dorfman HD: Focal lytic lesions associated with stem loosening in total hip prosthesis. Am J Roentgenol 144:977, 1985
-
(1985)
Am J Roentgenol
, vol.144
, pp. 977
-
-
Scott Jr., W.W.1
Riley Jr., L.H.2
Dorfman, H.D.3
-
22
-
-
0026328950
-
The arthroscopic evaluation and characteristics of severe polyethylene wear in total knee arthroplasty
-
Mintz L, Tsao AK, Stulberg SD, Wright T: The arthroscopic evaluation and characteristics of severe polyethylene wear in total knee arthroplasty. Clin Orthop 273:215, 1991
-
(1991)
Clin Orthop
, vol.273
, pp. 215
-
-
Mintz, L.1
Tsao, A.K.2
Stulberg, S.D.3
Wright, T.4
-
23
-
-
0024058346
-
Failure of the polyethylene bearing surface of a total knee replacement within four years: A case report
-
Engh GA: Failure of the polyethylene bearing surface of a total knee replacement within four years: a case report. J Bone Joint Surg Am 70:1093, 1988
-
(1988)
J Bone Joint Surg Am
, vol.70
, pp. 1093
-
-
Engh, G.A.1
-
24
-
-
0017129995
-
Extensive localized bone resorption in the femur following total hip replacement
-
Harris WH, Schiller AL, Scholler JM, et al: Extensive localized bone resorption in the femur following total hip replacement. J Bone Joint Surg Am 58:612, 1979
-
(1979)
J Bone Joint Surg Am
, vol.58
, pp. 612
-
-
Harris, W.H.1
Schiller, A.L.2
Scholler, J.M.3
-
25
-
-
0028785801
-
Catastrophic osteolysis in total knee replacement: A report of 17 cases
-
Robinson EJ, Mulliken BD, Bourne RB, et al: Catastrophic osteolysis in total knee replacement: a report of 17 cases. Clin Orthop 321:98, 1995
-
(1995)
Clin Orthop
, vol.321
, pp. 98
-
-
Robinson, E.J.1
Mulliken, B.D.2
Bourne, R.B.3
-
26
-
-
0027208262
-
Extensive osteolysis around an aseptic, stable, uncemented total knee replacement
-
Berry DJ, Wold LE, Rand JA: Extensive osteolysis around an aseptic, stable, uncemented total knee replacement. Clin Orthop 293:204, 1993
-
(1993)
Clin Orthop
, vol.293
, pp. 204
-
-
Berry, D.J.1
Wold, L.E.2
Rand, J.A.3
-
27
-
-
0028222806
-
An osteolytic lesion associated with polyethylene debris adjacent to a stable total knee prosthesis
-
Kane KR, Deheer DH, Beebe JD, Bereza R: An osteolytic lesion associated with polyethylene debris adjacent to a stable total knee prosthesis. Orthop Rev 23:332, 1994
-
(1994)
Orthop Rev
, vol.23
, pp. 332
-
-
Kane, K.R.1
Deheer, D.H.2
Beebe, J.D.3
Bereza, R.4
-
28
-
-
0026698866
-
Massive femoral osteolysis and early disintegration of a polyethylene-bearing surface of a total knee replacement
-
Kilgus DJ, Funahashi TT, Campbell PA: Massive femoral osteolysis and early disintegration of a polyethylene-bearing surface of a total knee replacement. J Bone Joint Surg Am 74:770, 1992
-
(1992)
J Bone Joint Surg Am
, vol.74
, pp. 770
-
-
Kilgus, D.J.1
Funahashi, T.T.2
Campbell, P.A.3
-
29
-
-
0028006686
-
Supracondylar fracture of the femur associated with polyethylene wear after total knee arthroplasty
-
Rand J: Supracondylar fracture of the femur associated with polyethylene wear after total knee arthroplasty. J Bone Joint Surg Am 76:1389, 1994
-
(1994)
J Bone Joint Surg Am
, vol.76
, pp. 1389
-
-
Rand, J.1
-
30
-
-
0025649614
-
Fracture of the femoral component in unicompartmental total knee arthroplasty
-
Cameron HU, Welsh RP: Fracture of the femoral component in unicompartmental total knee arthroplasty. J Arthroplasty 5:315, 1990
-
(1990)
J Arthroplasty
, vol.5
, pp. 315
-
-
Cameron, H.U.1
Welsh, R.P.2
-
31
-
-
0022541244
-
Fracture of a unicompartmental knee replacement femoral component
-
Moreland JR: Fracture of a unicompartmental knee replacement femoral component. Clin Orthop 206: 166, 1986
-
(1986)
Clin Orthop
, vol.206
, pp. 166
-
-
Moreland, J.R.1
-
32
-
-
0023233165
-
Fatigue failure of the femoral component of a unicompartmental knee
-
Sandborn PM, Cook SD, Kester MA, Haddad RJ Jr: Fatigue failure of the femoral component of a unicompartmental knee. Clin Orthop 222:249, 1987
-
(1987)
Clin Orthop
, vol.222
, pp. 249
-
-
Sandborn, P.M.1
Cook, S.D.2
Kester, M.A.3
Haddad Jr., R.J.4
-
33
-
-
0025956699
-
Fatigue failure of non-cemented porous-coating implants: A retrieved study
-
Cook SD, Thomas KA: Fatigue failure of non-cemented porous-coating implants: a retrieved study. J Bone Joint Surg Br 73:20, 1991
-
(1991)
J Bone Joint Surg Br
, vol.73
, pp. 20
-
-
Cook, S.D.1
Thomas, K.A.2
-
34
-
-
0027403263
-
Fracture of the femoral component in cementless total knee arthroplasty
-
Whiteside LA, Fosco DR, Brooks JG Jr: Fracture of the femoral component in cementless total knee arthroplasty. Clin Orthop 286:71, 1993
-
(1993)
Clin Orthop
, vol.286
, pp. 71
-
-
Whiteside, L.A.1
Fosco, D.R.2
Brooks Jr., J.G.3
-
35
-
-
0030935434
-
Stress fracture of the femoral component in total knee replacement: A report of 3 cases
-
Wada M, Imura S, Bo A, et al: Stress fracture of the femoral component in total knee replacement: a report of 3 cases. Int Orthop 21:54, 1997
-
(1997)
Int Orthop
, vol.21
, pp. 54
-
-
Wada, M.1
Imura, S.2
Bo, A.3
-
36
-
-
0026346472
-
Analysis of the failure of 122 polyethylene inserts from uncemented tibial knee components
-
Collier JP, Mayor MB, McNamara JL, et al: Analysis of the failure of 122 polyethylene inserts from uncemented tibial knee components. Clin Orthop 273: 232, 1991
-
(1991)
Clin Orthop
, vol.273
, pp. 232
-
-
Collier, J.P.1
Mayor, M.B.2
McNamara, J.L.3
-
37
-
-
0026527293
-
Polyethylene wear of metal-backed tibial components in total and unicompartmental knee prosthesis
-
Engh GA, Dwyer KA, Hanes CK: Polyethylene wear of metal-backed tibial components in total and unicompartmental knee prosthesis. J Bone Joint Surg Br 74:9, 1992
-
(1992)
J Bone Joint Surg Br
, vol.74
, pp. 9
-
-
Engh, G.A.1
Dwyer, K.A.2
Hanes, C.K.3
-
38
-
-
0026569950
-
Aggressive granulomatosis from polyethylene failure in an uncemented knee replacement
-
Nolan JF, Bucknill TM: Aggressive granulomatosis from polyethylene failure in an uncemented knee replacement. J Bone Joint Surg Br 74:23, 1992
-
(1992)
J Bone Joint Surg Br
, vol.74
, pp. 23
-
-
Nolan, J.F.1
Bucknill, T.M.2
-
41
-
-
0028849719
-
Effect of component fixation method on osteolysis in total knee arthroplasty
-
Ezzet KA, Garcia R, Barrack RL: Effect of component fixation method on osteolysis in total knee arthroplasty. Clin Orthop 321:86, 1995
-
(1995)
Clin Orthop
, vol.321
, pp. 86
-
-
Ezzet, K.A.1
Garcia, R.2
Barrack, R.L.3
-
42
-
-
0022892456
-
The New Jersey contact stress knee replacement system: Biomechanical rationale and review of the first 123 cemented cases
-
Buechel FF, Pappas MJ: The New Jersey contact stress knee replacement system: biomechanical rationale and review of the first 123 cemented cases. Arch Orthop Trauma Surg 105:197, 1986
-
(1986)
Arch Orthop Trauma Surg
, vol.105
, pp. 197
-
-
Buechel, F.F.1
Pappas, M.J.2
-
43
-
-
0030635257
-
Polyethylene failure in New Jersey low contact stress total knee arthroplasty
-
Huang CH, Young TH, Lee YT, et al: Polyethylene failure in New Jersey low contact stress total knee arthroplasty. J Biomed Mater Res 39:153, 1998
-
(1998)
J Biomed Mater Res
, vol.39
, pp. 153
-
-
Huang, C.H.1
Young, T.H.2
Lee, Y.T.3
|