메뉴 건너뛰기




Volumn 14, Issue 2, 1999, Pages 165-171

Relationship between wear debris particles and polyethylene surface damage in primary total knee arthroplasty

Author keywords

Articulating surface congruency; Osteolysis; Polyethylene surface damage; Primary total knee arthroplasty; Wear debris

Indexed keywords

CHROMIUM; COBALT; POLYETHYLENE;

EID: 0032972217     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0883-5403(99)90120-1     Document Type: Article
Times cited : (53)

References (30)
  • 1
    • 0001037690 scopus 로고
    • The cellular process of aseptic loosening of joint arthroplasties
    • Goodman SB: The cellular process of aseptic loosening of joint arthroplasties. Semin Arthroplasty 4:205, 1993
    • (1993) Semin Arthroplasty , vol.4 , pp. 205
    • Goodman, S.B.1
  • 2
    • 0030175572 scopus 로고    scopus 로고
    • Comparison and quantitation of wear debris between failed total hip and total knee arthroplasty
    • Hirakawa K, Bauer TW, Stulberg BN, et al: Comparison and quantitation of wear debris between failed total hip and total knee arthroplasty. J Biomed Mater Res 31:257, 1996
    • (1996) J Biomed Mater Res , vol.31 , pp. 257
    • Hirakawa, K.1    Bauer, T.W.2    Stulberg, B.N.3
  • 3
    • 0029839935 scopus 로고    scopus 로고
    • Characterization and comparison of wear debris from failed total hip implants of different types
    • Hirakawa K, Bauer TW, Stulberg BN, et al: Characterization and comparison of wear debris from failed total hip implants of different types. J Bone Joint Surg Am 78:1235, 1996
    • (1996) J Bone Joint Surg Am , vol.78 , pp. 1235
    • Hirakawa, K.1    Bauer, T.W.2    Stulberg, B.N.3
  • 4
    • 0027260321 scopus 로고
    • Studies of the mechanism by which the mechanical failure of polymethylmethacrylate beads to bone resorption
    • Horowitz SM, Doty SB, Lane JM, et al: Studies of the mechanism by which the mechanical failure of polymethylmethacrylate beads to bone resorption. J Bone Joint Surg Am 75:802, 1993
    • (1993) J Bone Joint Surg Am , vol.75 , pp. 802
    • Horowitz, S.M.1    Doty, S.B.2    Lane, J.M.3
  • 5
    • 0027326202 scopus 로고
    • Production of cytokines around loosened cemented acetabular components
    • Jiranek WA, Machado M, Jasty M, et al: Production of cytokines around loosened cemented acetabular components. J Bone Joint Surg Am 75:863, 1993
    • (1993) J Bone Joint Surg Am , vol.75 , pp. 863
    • Jiranek, W.A.1    Machado, M.2    Jasty, M.3
  • 6
    • 0029120016 scopus 로고
    • Periprosthetic osteolysis in total hip arthroplasty: The role of particulate wear debris
    • Maloney WJ, Smith RL: Periprosthetic osteolysis in total hip arthroplasty: the role of particulate wear debris. J Bone Joint Surg Am 77:1448, 1995
    • (1995) J Bone Joint Surg Am , vol.77 , pp. 1448
    • Maloney, W.J.1    Smith, R.L.2
  • 7
    • 0026784175 scopus 로고
    • Osteolysis after total knee arthroplasty without cement
    • Peters PC, Engh GA, Dwyer KA, et al: Osteolysis after total knee arthroplasty without cement. J Bone Joint Surg Am 74:864, 1992
    • (1992) J Bone Joint Surg Am , vol.74 , pp. 864
    • Peters, P.C.1    Engh, G.A.2    Dwyer, K.A.3
  • 8
    • 0026550544 scopus 로고
    • The mechanism of loosening of cemented acetabular components in total hip arthroplasty: Analysis of specimens retrieved at autopsy
    • Schmalzried TP, Kwong LM, Jasty M, et al: The mechanism of loosening of cemented acetabular components in total hip arthroplasty: analysis of specimens retrieved at autopsy. Clin Orthop 274:60, 1992
    • (1992) Clin Orthop , vol.274 , pp. 60
    • Schmalzried, T.P.1    Kwong, L.M.2    Jasty, M.3
  • 9
    • 0029051093 scopus 로고
    • Cellular mediators secreted by interfacial membranes obtained at revision total hip arthroplasty
    • Shanbhag AS, Jacobs JJ, Black J, et al: Cellular mediators secreted by interfacial membranes obtained at revision total hip arthroplasty. J Arthroplasty 10:498, 1995
    • (1995) J Arthroplasty , vol.10 , pp. 498
    • Shanbhag, A.S.1    Jacobs, J.J.2    Black, J.3
  • 10
    • 0141656821 scopus 로고    scopus 로고
    • Characterization and quantitation of wear debris in primary total knee arthroplasty
    • Hirakawa K, Yamaguchi M, Bauer TW: Characterization and quantitation of wear debris in primary total knee arthroplasty. Semin Arthroplasty 7:1, 1996
    • (1996) Semin Arthroplasty , vol.7 , pp. 1
    • Hirakawa, K.1    Yamaguchi, M.2    Bauer, T.W.3
  • 11
    • 0029973991 scopus 로고    scopus 로고
    • Characterization of wear debris from tissues adjacent to failed knee implants of three different designs
    • Hirakawa K, Bauer TW, Stulberg BN, et al: Characterization of wear debris from tissues adjacent to failed knee implants of three different designs. Clin Orthop 331:151, 1996
    • (1996) Clin Orthop , vol.331 , pp. 151
    • Hirakawa, K.1    Bauer, T.W.2    Stulberg, B.N.3
  • 12
    • 0028076951 scopus 로고
    • Isolation and characterization of debris in membrane around total joint prostheses
    • Margevicius KJ, Bauer TW, McMahon JT, et al: Isolation and characterization of debris in membrane around total joint prostheses. J Bone Joint Surg Am 76:1664, 1994
    • (1994) J Bone Joint Surg Am , vol.76 , pp. 1664
    • Margevicius, K.J.1    Bauer, T.W.2    McMahon, J.T.3
  • 13
    • 0027972449 scopus 로고
    • Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty
    • Wasielewski RC, Galante JO, Leighty RM, et al: Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop 299:31, 1994
    • (1994) Clin Orthop , vol.299 , pp. 31
    • Wasielewski, R.C.1    Galante, J.O.2    Leighty, R.M.3
  • 14
    • 0026527293 scopus 로고
    • Polyethylene wear of metal-backed tibial components in total and unicompartmental knee prostheses
    • Engh GA, Dwyer K, Hanes CK: Polyethylene wear of metal-backed tibial components in total and unicompartmental knee prostheses. J Bone Joint Surg Br 74:9, 1992
    • (1992) J Bone Joint Surg Br , vol.74 , pp. 9
    • Engh, G.A.1    Dwyer, K.2    Hanes, C.K.3
  • 15
    • 0020826593 scopus 로고
    • Retrieval analysis of total knee prostheses: A method and its application to 48 total condylar prostheses
    • Hood RW, Wright TM, Burstein AH: Retrieval analysis of total knee prostheses: a method and its application to 48 total condylar prostheses. J Biomed Mater Res 17:829, 1983
    • (1983) J Biomed Mater Res , vol.17 , pp. 829
    • Hood, R.W.1    Wright, T.M.2    Burstein, A.H.3
  • 17
    • 0023697318 scopus 로고
    • Wear of ultra-high-molecular-weight polyethylene components of 90 retrieved knee prostheses
    • Landy MM, Walker PS: Wear of ultra-high-molecular-weight polyethylene components of 90 retrieved knee prostheses. J Arthroplasty 3:S73, 1988 (Suppl)
    • (1988) J Arthroplasty , vol.3 , Issue.SUPPL.
    • Landy, M.M.1    Walker, P.S.2
  • 18
    • 0028501856 scopus 로고
    • Polyethylene wear debris and tissue reactions in knee as compared to hip replacement prostheses
    • Schmalzried TP, Jasty M, Rosenberg A, et al: Polyethylene wear debris and tissue reactions in knee as compared to hip replacement prostheses. J Applied Biomater 5:185, 1994
    • (1994) J Applied Biomater , vol.5 , pp. 185
    • Schmalzried, T.P.1    Jasty, M.2    Rosenberg, A.3
  • 19
    • 0027185807 scopus 로고
    • Tibial highdensity polyethylene wear in conforming tibiofemoral prosthesis
    • Plante-Bordeneuve P, Freeman MAR: Tibial highdensity polyethylene wear in conforming tibiofemoral prosthesis. J Bone Joint Surg Br 75:630, 1993
    • (1993) J Bone Joint Surg Br , vol.75 , pp. 630
    • Plante-Bordeneuve, P.1    Freeman, M.A.R.2
  • 20
    • 0022504260 scopus 로고
    • The problem of surface damage in polyethylene total knee components
    • Wright TM, Bartel DL: The problem of surface damage in polyethylene total knee components. Clin Orthop 205:67, 1986
    • (1986) Clin Orthop , vol.205 , pp. 67
    • Wright, T.M.1    Bartel, D.L.2
  • 21
    • 0026347408 scopus 로고
    • Investigation of early surface delamination observed in retrieved heat-pressed tibial inserts
    • Bloebaum RD, Nelson K, Dorr LD, et al: Investigation of early surface delamination observed in retrieved heat-pressed tibial inserts. Clin Orthop 269:120, 1990
    • (1990) Clin Orthop , vol.269 , pp. 120
    • Bloebaum, R.D.1    Nelson, K.2    Dorr, L.D.3
  • 22
    • 0023815238 scopus 로고
    • Should the posterior cruciate ligament be retained or resected in condylar nonmeniscal knee arthroplasty? The case for resection
    • Freeman MAR, Railton GT: Should the posterior cruciate ligament be retained or resected in condylar nonmeniscal knee arthroplasty? The case for resection. J Arthroplasty 3:S3, 1988 (Suppl)
    • (1988) J Arthroplasty , vol.3 , Issue.SUPPL.
    • Freeman, M.A.R.1    Railton, G.T.2
  • 23
    • 0028593331 scopus 로고
    • The posterior cruciate ligament in total knee surgery: Save, sacrifice, or substitute?
    • Hirsch HS, Lotke PA, Morrison LD: The posterior cruciate ligament in total knee surgery: save, sacrifice, or substitute? Clin Orthop 309:64, 1994
    • (1994) Clin Orthop , vol.309 , pp. 64
    • Hirsch, H.S.1    Lotke, P.A.2    Morrison, L.D.3
  • 24
    • 0028008566 scopus 로고
    • Posteromedial tibial polyethylene failure in total knee replacements
    • Lewis P, Rorabeck CH, Bourne RB, et al: Posteromedial tibial polyethylene failure in total knee replacements. Clin Orthop 299:11, 1994
    • (1994) Clin Orthop , vol.299 , pp. 11
    • Lewis, P.1    Rorabeck, C.H.2    Bourne, R.B.3
  • 25
    • 2642629607 scopus 로고    scopus 로고
    • Kinematics of cruciate retaining and substituting knee replacements during step-up
    • Banks SA, Markovich GD, Hodge WA: Kinematics of cruciate retaining and substituting knee replacements during step-up (abstract). Trans Orthop Res Soc 21:724, 1996
    • (1996) Trans Orthop Res Soc , vol.21 , pp. 724
    • Banks, S.A.1    Markovich, G.D.2    Hodge, W.A.3
  • 26
    • 0028971165 scopus 로고
    • Fluoroscopic analysis of kinematics after posterior cruciate retaining knee arthroplasty
    • Stiehl JB, Komistek RD, Dennis DA, et al: Fluoroscopic analysis of kinematics after posterior cruciate retaining knee arthroplasty. J Bone Joint Surg Br 77:884, 1995
    • (1995) J Bone Joint Surg Br , vol.77 , pp. 884
    • Stiehl, J.B.1    Komistek, R.D.2    Dennis, D.A.3
  • 27
    • 0004161764 scopus 로고
    • Design of total knee replacements
    • Petty W (ed): WB Saunders, Philadelphia
    • Bartel DL, Wright TM: Design of total knee replacements, p. 467. In Petty W (ed): Total joint replacement. WB Saunders, Philadelphia 1991
    • (1991) Total Joint Replacement , pp. 467
    • Bartel, D.L.1    Wright, T.M.2
  • 28
    • 0001980826 scopus 로고
    • Radiation induced oxidation of machined or molded UHMWPE after seventeen years
    • McKellop H, Yoem B, Campbell P, et al: Radiation induced oxidation of machined or molded UHMWPE after seventeen years (abstract). Trans Soc Biomater 18:54, 1995
    • (1995) Trans Soc Biomater , vol.18 , pp. 54
    • McKellop, H.1    Yoem, B.2    Campbell, P.3
  • 29
    • 0942287546 scopus 로고
    • The case for resection of the posterior cruciate ligament
    • Moilanen T, Freeman MAR: The case for resection of the posterior cruciate ligament. J Arthroplasty 10: 564, 1995
    • (1995) J Arthroplasty , vol.10 , pp. 564
    • Moilanen, T.1    Freeman, M.A.R.2
  • 30
    • 0028102058 scopus 로고
    • Post-irradiation aging of ultra-high molecular weight polyethylene
    • Rimnac CM, Klein RW, Betts F, et al: Post-irradiation aging of ultra-high molecular weight polyethylene. J Bone Joint Surg Am 76:1052, 1994
    • (1994) J Bone Joint Surg Am , vol.76 , pp. 1052
    • Rimnac, C.M.1    Klein, R.W.2    Betts, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.