Volumn 25, Issue 10, 1998, Pages 1837-1844

Evaluation of optimized compensators on a 3D planning system

Author keywords

Compensators; Optimization; Photon dose calculation; Radiotherapy; Treatment planning systems

Indexed keywords

OPTIMIZATION; RADIOTHERAPY; TISSUE;

EID: 0031762874     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.598369     Document Type: Article
Times cited : (20)

References (18)
  • 1
    • 0001185624 scopus 로고
    • A compensator for variations in tissue thickness for high energy beams
    • F. Ellis, E. J. Hall, and R. Oliver, "A compensator for variations in tissue thickness for high energy beams," Br. J. Radiol. 32, 421-422 (1959).
    • (1959) Br. J. Radiol. , vol.32 , pp. 421-422
    • Ellis, F.1    Hall, E.J.2    Oliver, R.3
  • 2
    • 84907107012 scopus 로고
    • Individually designed filters in Cobalt 60 teletherapy
    • L. Sundborm, "Individually designed filters in Cobalt 60 teletherapy," Acta Radiol.: Ther , Phys., Biol. 2, 189-208 (1964).
    • (1964) Acta Radiol.: Ther , Phys., Biol. , vol.2 , pp. 189-208
    • Sundborm, L.1
  • 3
    • 0019992678 scopus 로고
    • Compensating filters for high energy x-rays
    • A L. Boyer, quot;Compensating filters for high energy x-rays," Med. Phys. 9, 429-433 (1982).
    • (1982) Med. Phys. , vol.9 , pp. 429-433
    • Boyer, A.L.1
  • 4
    • 0026806134 scopus 로고
    • Missing tissue compensators: Evaluation and optimization of a commercial system
    • W. Ansbacher, D M. Robinson;, and J. W. Scrimger, "Missing tissue compensators: Evaluation and optimization of a commercial system," Med. Phys. 19, 1267-1272 (1992).
    • (1992) Med. Phys. , vol.19 , pp. 1267-1272
    • Ansbacher, W.1    Robinson, D.M.2    Scrimger, J.W.3
  • 5
    • 0016266080 scopus 로고
    • A method of large irregular field compensation
    • P. M. K. Leung, J. Van Dyk, and J. Robins, "A method of large irregular field compensation," Br. J. Radiol. 47, 805-810 (1974).
    • (1974) Br. J. Radiol. , vol.47 , pp. 805-810
    • Leung, P.M.K.1    Van Dyk, J.2    Robins, J.3
  • 6
    • 0019833340 scopus 로고
    • Improved method for the design of tissue compensators
    • P. C. Shragge and M. S. Patterson, "Improved method for the design of tissue compensators," Med. Phys. 8, 885-891 (1981).
    • (1981) Med. Phys. , vol.8 , pp. 885-891
    • Shragge, P.C.1    Patterson, M.S.2
  • 7
    • 0023737996 scopus 로고
    • Computer aided design and verification of megavoltage tissue compensators for oblique beams
    • B. A. Faddegon and P. Pfalzner, "Computer aided design and verification of megavoltage tissue compensators for oblique beams," Med. Phys. 15, 757-762 (1988).
    • (1988) Med. Phys. , vol.15 , pp. 757-762
    • Faddegon, B.A.1    Pfalzner, P.2
  • 10
    • 0028710757 scopus 로고
    • Description and evaluation of a new 3-D computerized treatment planning dose compensator system
    • A. S. Beddar, C. Thompson, and P. M. K. Leung, "Description and evaluation of a new 3-D computerized treatment planning dose compensator system" Medical Disimetry 19, 227-235 (1994).
    • (1994) Medical Disimetry , vol.19 , pp. 227-235
    • Beddar, A.S.1    Thompson, C.2    Leung, P.M.K.3
  • 11
    • 0028269366 scopus 로고
    • Implementation of a three-dimensional compensation system base on computed tomography generated surface contours and tissue inhomogeneities
    • P. A. Jusinic, M B. Podgorsak, and B. R. Paliwal, "Implementation of a three-dimensional compensation system base on computed tomography generated surface contours and tissue inhomogeneities," Med. Phys. 21, 357-365 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 357-365
    • Jusinic, P.A.1    Podgorsak, M.B.2    Paliwal, B.R.3
  • 12
    • 0026750950 scopus 로고
    • A pencil beam model for photon dose calculation
    • A. Ahnesjö, "A pencil beam model for photon dose calculation," Med Phys. 19, 263-273 (1992).
    • (1992) Med Phys. , vol.19 , pp. 263-273
    • Ahnesjö, A.1
  • 13
    • 0027982040 scopus 로고
    • The dosimetric verification of a pencil beam based treatment planning system
    • T. Knoos, T. C. Ceberg, L. Weber, and P Nilsson, "The dosimetric verification of a pencil beam based treatment planning system," Phys Med. Biol. 39, 1609-1628 (1994).
    • (1994) Phys Med. Biol. , vol.39 , pp. 1609-1628
    • Knoos, T.1    Ceberg, T.C.2    Weber, L.3    Nilsson, P.4
  • 14
    • 0029064833 scopus 로고
    • Limitations of a pencil beam approach to photon dose calculation in lung tissue
    • T. Knoos, A. Ahnesjö, P. Nilsson, and L. Weber, "Limitations of a pencil beam approach to photon dose calculation in lung tissue," Phys. Med Biol. 40, 1411-1420 (1995).
    • (1995) Phys. Med Biol. , vol.40 , pp. 1411-1420
    • Knoos, T.1    Ahnesjö, A.2    Nilsson, P.3    Weber, L.4
  • 15
    • 0028783999 scopus 로고
    • Modeling transmission and scatter for photon beam attenuators
    • A. Ahnesjö, L Weber, and P Nilsson, "Modeling transmission and scatter for photon beam attenuators," Med. Phys. 22, 1711-1720 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 1711-1720
    • Ahnesjö, A.1    Weber, L.2    Nilsson, P.3
  • 16
    • 0343416121 scopus 로고
    • Compensation for tissue inhomogeneity in cobalt 60 therapy
    • M. A. Ellis, A. Feldman, and M. A. Oliver, "Compensation for tissue inhomogeneity in cobalt 60 therapy," Br. J. Radiol. 37, 795-798 (1964).
    • (1964) Br. J. Radiol. , vol.37 , pp. 795-798
    • Ellis, M.A.1    Feldman, A.2    Oliver, M.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.