-
1
-
-
0001185624
-
A compensator for variations in tissue thickness for high energy beam
-
F. Ellis, E. J. Hall, and R. Oliver, "A compensator for variations in tissue thickness for high energy beam," Br. J. Radiol. 32, 421-422 (1959).
-
(1959)
Br. J. Radiol.
, vol.32
, pp. 421-422
-
-
Ellis, F.1
Hall, E.J.2
Oliver, R.3
-
2
-
-
38249013626
-
Photon dose calculations for three-dimensional radiation treatment planning
-
J. A. Purdy, "Photon dose calculations for three-dimensional radiation treatment planning," Sem. Radiat. Oncol. 2, 235-245 (1992).
-
(1992)
Sem. Radiat. Oncol.
, vol.2
, pp. 235-245
-
-
Purdy, J.A.1
-
3
-
-
36149040555
-
A liquid ionization detector for digital radiography of therapeutic megavoltage photon beams
-
H. Meertens, M. van Herk, and I. Weeda, "A liquid ionization detector for digital radiography of therapeutic megavoltage photon beams," Phys. Med. Biol. 30, 313-321 (1985).
-
(1985)
Phys. Med. Biol.
, vol.30
, pp. 313-321
-
-
Meertens, H.1
Van Herk, M.2
Weeda, I.3
-
4
-
-
0025331845
-
First clinical experience with a newly developed electronic portal imaging device
-
H. Meertens, M. van Herk, J. Bijhold, and H. Bartelink, "First clinical experience with a newly developed electronic portal imaging device," Int. J. Radiat. Oncol. Biol. Phys. 18, 1173-1181 (1990).
-
(1990)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.18
, pp. 1173-1181
-
-
Meertens, H.1
Van Herk, M.2
Bijhold, J.3
Bartelink, H.4
-
5
-
-
0023885087
-
A matrix ionization chamber imaging device for on-line patient setup verification during radiotherapy
-
M. van Herk and H. Meertens, "A matrix ionization chamber imaging device for on-line patient setup verification during radiotherapy," Radiother. Oncol. 11, 369-378 (1988).
-
(1988)
Radiother. Oncol.
, vol.11
, pp. 369-378
-
-
Van Herk, M.1
Meertens, H.2
-
6
-
-
0025895695
-
Physical aspects of a liquid filled ionization chamber with pulsed polarizing voltage
-
M. van Herk, "Physical aspects of a liquid filled ionization chamber with pulsed polarizing voltage," Med. Phys. 18, 692-702 (1991).
-
(1991)
Med. Phys.
, vol.18
, pp. 692-702
-
-
Van Herk, M.1
-
7
-
-
0026570956
-
A review of electronic portal imaging device (EPIDs)
-
A. L. Boyer, L. Antonuk, A. Fenster, M. van Herk, H. Meertens, P. Monro, L. E. Reinstein, and J. Wong, "A review of electronic portal imaging device (EPIDs)," Med. Phys. 19, 1-16 (1992).
-
(1992)
Med. Phys.
, vol.19
, pp. 1-16
-
-
Boyer, A.L.1
Antonuk, L.2
Fenster, A.3
Van Herk, M.4
Meertens, H.5
Monro, P.6
Reinstein, L.E.7
Wong, J.8
-
8
-
-
0028149975
-
Technique for automating compensator design for lung inho-mogeneity correction using an electron portal imaging device
-
F.-F. Yin, "Technique for automating compensator design for lung inho-mogeneity correction using an electron portal imaging device," Med. Phys. 21, 1729-1732 (1994).
-
(1994)
Med. Phys.
, vol.21
, pp. 1729-1732
-
-
Yin, F.-F.1
-
9
-
-
0029153633
-
Portal dosimetry using a liquid ionization chamber matrix: Dose response studies
-
Y. Zhu, X.-Q. Jiang, and J. v. Dyk, "Portal dosimetry using a liquid ionization chamber matrix: Dose response studies," Med. Phys. 22, 1101-1106 (1995).
-
(1995)
Med. Phys.
, vol.22
, pp. 1101-1106
-
-
Zhu, Y.1
Jiang, X.-Q.2
Dyk, J.V.3
-
10
-
-
0028857468
-
The use of an electronic portal imaging device for exit dosimetry and quality control measures
-
M. C. Kirby and P. C. Williams, "The use of an electronic portal imaging device for exit dosimetry and quality control measures," Int. I. Radiat. Oncol. Biol. Phys. 31, 593-603 (1995).
-
(1995)
Int. I. Radiat. Oncol. Biol. Phys.
, vol.31
, pp. 593-603
-
-
Kirby, M.C.1
Williams, P.C.2
-
11
-
-
0028145651
-
Input/output characteristics of a matrix ion-chamber electronic portal imaging device
-
F.-F. Yin, M. C. Schell, and P. Rubin, "Input/output characteristics of a matrix ion-chamber electronic portal imaging device," Med. Phys. 21, 1447-1454 (1994).
-
(1994)
Med. Phys.
, vol.21
, pp. 1447-1454
-
-
Yin, F.-F.1
Schell, M.C.2
Rubin, P.3
-
12
-
-
0019992678
-
Compensating filters for high energy x rays
-
A. L. Boyer, "Compensating filters for high energy x rays," Med. Phys. 9, 429-433 (1982).
-
(1982)
Med. Phys.
, vol.9
, pp. 429-433
-
-
Boyer, A.L.1
-
13
-
-
0028710757
-
Description and evaluation of a new 3-D computerized treatment planning dose compensator system
-
A. S. Beddar, C. Thomason, and P. M. K. Leung, "Description and evaluation of a new 3-D computerized treatment planning dose compensator system," Med. Dosim. 19, 227-235 (1994).
-
(1994)
Med. Dosim.
, vol.19
, pp. 227-235
-
-
Beddar, A.S.1
Thomason, C.2
Leung, P.M.K.3
-
14
-
-
0027966969
-
Analytic modeling of photon scatter from flattening filters in photon therapy beams
-
A. Ahnesjö, "Analytic modeling of photon scatter from flattening filters in photon therapy beams," Med. Phys. 21, 1227-1235 (1994).
-
(1994)
Med. Phys.
, vol.21
, pp. 1227-1235
-
-
Ahnesjö, A.1
-
15
-
-
0022645280
-
Scattered photons produced by beam-modifying filters
-
P. Huang, L. M. Chin, and B. E. Bjarngard, "Scattered photons produced by beam-modifying filters," Med. Phys. 13, 57-63 (1986).
-
(1986)
Med. Phys.
, vol.13
, pp. 57-63
-
-
Huang, P.1
Chin, L.M.2
Bjarngard, B.E.3
-
16
-
-
0025271385
-
The calculation of transmission through a photon beam attenuator using sector integration
-
E. Papiez and G. Froese, "The calculation of transmission through a photon beam attenuator using sector integration," Med. Phys. 17, 281-286 (1990).
-
(1990)
Med. Phys.
, vol.17
, pp. 281-286
-
-
Papiez, E.1
Froese, G.2
-
17
-
-
0022655992
-
Broad beam attenuation of cobalt-60 gamma rays and 6-, 18-, and 25-MV x rays by lead
-
J. van Dyk, "Broad beam attenuation of cobalt-60 gamma rays and 6-, 18-, and 25-MV x rays by lead," Med. Phys. 13, 105-110 (1986).
-
(1986)
Med. Phys.
, vol.13
, pp. 105-110
-
-
Van Dyk, J.1
|