-
1
-
-
0028094880
-
Circadian rhythm of serum interleukin-6 in rheumatoid arthritis
-
N. Arvidson, B. Gudbjornsson, L. Elfman, A.-C. Rydén, T.H. Tötterman and R. Hällgren, Circadian rhythm of serum interleukin-6 in rheumatoid arthritis, Ann Rheum Dis 53 (1994), 521-524.
-
(1994)
Ann Rheum Dis
, vol.53
, pp. 521-524
-
-
Arvidson, N.1
Gudbjornsson, B.2
Elfman, L.3
Rydén, A.-C.4
Tötterman, T.H.5
Hällgren, R.6
-
2
-
-
85021219235
-
-
National Institutes of Health, Bethesda, MD, April 15-16
-
Biomarkers and Surrogate Endpoints: Advancing Clinical Research and Applications, A Multidisciplinary, International Conference Sponsored by NIH and FDA, Natcher Conference Center, National Institutes of Health, Bethesda, MD, April 15-16, 1999.
-
(1999)
Biomarkers and Surrogate Endpoints: Advancing Clinical Research and Applications, A Multidisciplinary, International Conference Sponsored by NIH and FDA, Natcher Conference Center
-
-
-
3
-
-
85021232833
-
-
Code of Federal Regulations, Title 21, Volume 1 [Revised as of April 1, 2001], US Government Printing Office via GPO Access, 21CFR58, Good Laboratory Practice for Nonclinical Laboratory Studies
-
Code of Federal Regulations, Title 21, Volume 1 [Revised as of April 1, 2001], US Government Printing Office via GPO Access, 21CFR58, Good Laboratory Practice for Nonclinical Laboratory Studies.
-
-
-
-
4
-
-
85021234132
-
-
Code of Federal Regulations, Title 42, Volume 3 [Revised as of October 1, 2001], US Government Printing Office via GPO Access, 42CFR493, Clinical Laboratory Improvement Amendments
-
Code of Federal Regulations, Title 42, Volume 3 [Revised as of October 1, 2001], US Government Printing Office via GPO Access, 42CFR493, Clinical Laboratory Improvement Amendments.
-
-
-
-
5
-
-
0034859851
-
High-throughput microarray technologies: From genomics to clinics
-
L. Bubendorf, High-throughput microarray technologies: from genomics to clinics, Eur Urol 40 (2001), 231-238.
-
(2001)
Eur Urol
, vol.40
, pp. 231-238
-
-
Bubendorf, L.1
-
6
-
-
0025347355
-
A new radioimmunoassay for human alpha atrial natriuretic peptide and its physiological validation
-
L.M. Burrell, J. Palmer, J.A. Charlton, T. Thomas and P.H. Baylis, A new radioimmunoassay for human alpha atrial natriuretic peptide and its physiological validation, J Immunoassay 11 (1990), 159-175.
-
(1990)
J Immunoassay
, vol.11
, pp. 159-175
-
-
Burrell, L.M.1
Palmer, J.2
Charlton, J.A.3
Thomas, T.4
Baylis, P.H.5
-
7
-
-
0034951555
-
Standards for the medical laboratory - Harmonization and subsidiarity
-
D. Burnett and C. Blair, Standards for the medical laboratory - harmonization and subsidiarity, Clin Chim Acta 309 (2001), 137-145.
-
(2001)
Clin Chim Acta
, vol.309
, pp. 137-145
-
-
Burnett, D.1
Blair, C.2
-
8
-
-
0031557167
-
Validation of chromatographic methods in biomedical analysis. Viewpoint and discussion
-
R. Causon, Validation of chromatographic methods in biomedical analysis. Viewpoint and discussion, J Chromatogr B Biomed Sci Appl 689 (1997), 175-180.
-
(1997)
J Chromatogr B Biomed Sci Appl
, vol.689
, pp. 175-180
-
-
Causon, R.1
-
9
-
-
0034762311
-
Sequence analysis of the human genome: Implications for the understanding of nervous system function and disease
-
A. Cruvchik, G. Subramanian, S. Bruder and J.C. Venter, Sequence analysis of the human genome: implications for the understanding of nervous system function and disease, Arch Neurol 58 (2001), 1772-1778.
-
(2001)
Arch Neurol
, vol.58
, pp. 1772-1778
-
-
Cruvchik, A.1
Subramanian, G.2
Bruder, S.3
Venter, J.C.4
-
10
-
-
0029760199
-
Preanalytical factors and the measurement of cytokines in human subjects
-
I.B. Dugue, E. Leppanen and R. Grasbeck, Preanalytical factors and the measurement of cytokines in human subjects, Int J Clin Lab Res 26 (1996), 99-105.
-
(1996)
Int J Clin Lab Res
, vol.26
, pp. 99-105
-
-
Dugue, I.B.1
Leppanen, E.2
Grasbeck, R.3
-
11
-
-
0033989957
-
Validation of immunoassays for bioanalysis: A pharmaceutical industry perspective
-
J.W. Findlay, W.C. Smith, J.W. Lee, G.D. Nordblom, I. Das, B.S. DeSilva, M.N. Khan and R.R. Bowsher, Validation of immunoassays for bioanalysis: a pharmaceutical industry perspective, J Pharm Biomed Anal 21 (2000), 1249-1273.
-
(2000)
J Pharm Biomed Anal
, vol.21
, pp. 1249-1273
-
-
Findlay, J.W.1
Smith, W.C.2
Lee, J.W.3
Nordblom, G.D.4
Das, I.5
DeSilva, B.S.6
Khan, M.N.7
Bowsher, R.R.8
-
12
-
-
0003524742
-
-
AACC Press, Washington, DC
-
C.G. Fraser, Biological Variation: From Principles to Practice, AACC Press, Washington, DC, 2001, pp. 151.
-
(2001)
Biological Variation: From Principles to Practice
, pp. 151
-
-
Fraser, C.G.1
-
13
-
-
0031875640
-
Application of a new serum assay for type I collagen cross-linked N-telopeptides: Assessment of diurnal changes in bone turnover with and without alendronate treatment
-
B.J. Gertz, J.D. Clemens, S.D. Holland and S. Greenspan, Application of a new serum assay for type I collagen cross-linked N-telopeptides: assessment of diurnal changes in bone turnover with and without alendronate treatment, Calc Tiss Int 63 (1998), 102-106.
-
(1998)
Calc Tiss Int
, vol.63
, pp. 102-106
-
-
Gertz, B.J.1
Clemens, J.D.2
Holland, S.D.3
Greenspan, S.4
-
14
-
-
0034956346
-
Accreditation of external quality assessment schemes in the United Kingdom
-
D.J. Goldie, Accreditation of external quality assessment schemes in the United Kingdom, Clin Chim Acta 309 (2001), 179-181.
-
(2001)
Clin Chim Acta
, vol.309
, pp. 179-181
-
-
Goldie, D.J.1
-
15
-
-
0033388957
-
Molecular pathology and future developments
-
J.J. Going and B.A. Gusterson, Molecular pathology and future developments, Eur J Cancer 35 (1999), 1895-1904.
-
(1999)
Eur J Cancer
, vol.35
, pp. 1895-1904
-
-
Going, J.J.1
Gusterson, B.A.2
-
16
-
-
0003484310
-
-
US Dept of Health and Human Services, Food and Drug Administration, Center for Drug Evaluation and Research, May
-
Guidance for Industry, Bioanalytical Method Validation, US Dept of Health and Human Services, Food and Drug Administration, Center for Drug Evaluation and Research, May 2001, pp. 22.
-
(2001)
Guidance for Industry, Bioanalytical Method Validation
, pp. 22
-
-
-
17
-
-
0032985898
-
Requirements for accreditation by the College of American Pathologists Laboratory Accreditation Program
-
W.B. Hamlin, Requirements for accreditation by the College of American Pathologists Laboratory Accreditation Program, Arch Pathol Lab Med 123 (1999), 465-467.
-
(1999)
Arch Pathol Lab Med
, vol.123
, pp. 465-467
-
-
Hamlin, W.B.1
-
18
-
-
0027973614
-
An analysis of the Washington Conference Report on bioanalytical method validation
-
C. Hartmann, D.L. Massart and R.D. McDowall, An analysis of the Washington Conference Report on bioanalytical method validation, J Pharm Biomed Anal 11 (1994), 1337-1343.
-
(1994)
J Pharm Biomed Anal
, vol.11
, pp. 1337-1343
-
-
Hartmann, C.1
Massart, D.L.2
McDowall, R.D.3
-
19
-
-
0032102338
-
Validation of bioanalytical chromatographic methods
-
C. Hartmann, J. Smeyers-Verbeke, D.L. Massart and R.D. McDowall, Validation of bioanalytical chromatographic methods, J Pharm Biomed Anal 17 (1998), 193-218.
-
(1998)
J Pharm Biomed Anal
, vol.17
, pp. 193-218
-
-
Hartmann, C.1
Smeyers-Verbeke, J.2
Massart, D.L.3
McDowall, R.D.4
-
20
-
-
0033428029
-
Impact of pharmacogenomics on the clinical laboratory
-
P. Hess and D. Cooper, Impact of pharmacogenomics on the clinical laboratory, Mol Diagn 4 (1999), 289-298.
-
(1999)
Mol Diagn
, vol.4
, pp. 289-298
-
-
Hess, P.1
Cooper, D.2
-
21
-
-
0035471016
-
What can medicine learn from the human DNA sequence?
-
E. Hofmann, What can medicine learn from the human DNA sequence? Biochem 66 (2001), 1144-1152.
-
(2001)
Biochem
, vol.66
, pp. 1144-1152
-
-
Hofmann, E.1
-
22
-
-
0034957787
-
European Communities Confederation of Clinical Chemistry Working Group on Accreditation: Past, present and future
-
W. Huisman, European Communities Confederation of Clinical Chemistry Working Group on Accreditation: past, present and future, Clin Chim Acta 309 (2001), 111-114.
-
(2001)
Clin Chim Acta
, vol.309
, pp. 111-114
-
-
Huisman, W.1
-
25
-
-
0031780989
-
Preanalytical and analytical factors affecting laboratory results
-
K.M. Irjala and P.E. Gronroos, Preanalytical and analytical factors affecting laboratory results, Ann Med 30 (1998), 267-272.
-
(1998)
Ann Med
, vol.30
, pp. 267-272
-
-
Irjala, K.M.1
Gronroos, P.E.2
-
26
-
-
0034951795
-
ISO and Cen documents on quality in medical laboratories
-
D. Kenny, ISO and CEN documents on quality in medical laboratories, Clin Chim Acta 309 (2001), 121-125.
-
(2001)
Clin Chim Acta
, vol.309
, pp. 121-125
-
-
Kenny, D.1
-
27
-
-
0035169814
-
Description of a generally applicable model for the evaluation of uncertainty of measurement in clinical chemistry
-
J. Kristiansen, Description of a generally applicable model for the evaluation of uncertainty of measurement in clinical chemistry, Clin Chem Lab Med 10 (2001), 920-931.
-
(2001)
Clin Chem Lab Med
, vol.10
, pp. 920-931
-
-
Kristiansen, J.1
-
28
-
-
0033776406
-
Consulting the source code: Prospects for gene-based medical diagnostics
-
U. Landegren, Consulting the source code: prospects for gene-based medical diagnostics, J Intern Med 248 (2000), 271-276.
-
(2000)
J Intern Med
, vol.248
, pp. 271-276
-
-
Landegren, U.1
-
29
-
-
0035096809
-
Cardiovascular and humoral readjustment after different levels of head-up tilt in humans
-
Z. Laszlo, A. Rossler and H.G. Hinghofer-Szalkay, Cardiovascular and humoral readjustment after different levels of head-up tilt in humans, Aviat Space Environ Med 72 (2001), 193-201.
-
(2001)
Aviat Space Environ Med
, vol.72
, pp. 193-201
-
-
Laszlo, Z.1
Rossler, A.2
Hinghofer-Szalkay, H.G.3
-
30
-
-
0034951797
-
Role of external quality assurance schemes in assessing and improving quality in medical laboratories
-
J.C. Libeer, Role of external quality assurance schemes in assessing and improving quality in medical laboratories, Clin Chim Acta 309 (2001), 173-177.
-
(2001)
Clin Chim Acta
, vol.309
, pp. 173-177
-
-
Libeer, J.C.1
-
31
-
-
0023901932
-
Daytime fluctuations in blood tissue-type plasminogen activator (t-PA) and its fast acting inhibitor (PAI-1)
-
C. Kluft, A.f. Jie, D.C. Rijkin and J.H. Verheijen, Daytime fluctuations in blood tissue-type plasminogen activator (t-PA) and its fast acting inhibitor (PAI-1), Thromb Haemost 59 (1988), 329-332.
-
(1988)
Thromb Haemost
, vol.59
, pp. 329-332
-
-
Kluft, C.1
Jie, A.F.2
Rijkin, D.C.3
Verheijen, J.H.4
-
32
-
-
0033501681
-
Serum levels of hyaluronan, antigenic keratan sulfate, matrix metalloproteinase 3, and tissue inhibitor of metalloproteinase 1, change predictably in rheumatoid arthritis patients who have begun activity after a night of bed rest
-
D.H. Manicourt, P. Poilvache, A. Nzeusseu, A. van Egeren, J.P. Devogelaer, M.E. Lenz and E.J.-M.A. Thonar, Serum levels of hyaluronan, antigenic keratan sulfate, matrix metalloproteinase 3, and tissue inhibitor of metalloproteinase 1, change predictably in rheumatoid arthritis patients who have begun activity after a night of bed rest, Arthritis Rheum 42 (1999), 1861-1869.
-
(1999)
Arthritis Rheum
, vol.42
, pp. 1861-1869
-
-
Manicourt, D.H.1
Poilvache, P.2
Nzeusseu, A.3
Van Egeren, A.4
Devogelaer, J.P.5
Lenz, M.E.6
Thonar, E.J.-M.A.7
-
33
-
-
0026648833
-
Sex and race-related differences in liver-associated serum chemistry tests in young adults in the CARDIA study
-
T.A. Manolio, G.L. Burke, P.J. Savage, D.R. Jacobs, Jr, S. Sidney, L.E. Wagenknecht, R.M. Allman and R.P. Tracy, Sex and race-related differences in liver-associated serum chemistry tests in young adults in the CARDIA study, Clin Chem 38 (1992), 1853-1859.
-
(1992)
Clin Chem
, vol.38
, pp. 1853-1859
-
-
Manolio, T.A.1
Burke, G.L.2
Savage, P.J.3
Jacobs D.R., Jr.4
Sidney, S.5
Wagenknecht, L.E.6
Allman, R.M.7
Tracy, R.P.8
-
34
-
-
0034051043
-
The preanalytic phase. An important component of laboratory medicine
-
Comment in: Am J Clin Pathol. 114 (2000), 820-821
-
S. Narayanan, The preanalytic phase. An important component of laboratory medicine, Am J Clin Pathol 113 (2000), 429-452, Comment in: Am J Clin Pathol. 114 (2000), 820-821.
-
(2000)
Am J Clin Pathol
, vol.113
, pp. 429-452
-
-
Narayanan, S.1
-
35
-
-
0034699436
-
Validation and quality control of immunophenotyping in clinical flow cytometry
-
M.A. Owen, H.G. Vall, A.A. Hurley and S.B. Wormsley, Validation and quality control of immunophenotyping in clinical flow cytometry, J Immunol Meth 243 (2000), 33-50.
-
(2000)
J Immunol Meth
, vol.243
, pp. 33-50
-
-
Owen, M.A.1
Vall, H.G.2
Hurley, A.A.3
Wormsley, S.B.4
-
36
-
-
0032441609
-
Absolute metabolite quantification by in vivo NMR spectroscopy: I. Introduction, objectives and activities of a concerted action in biomedical research
-
F. Podo, O. Henriksen, W.M. Bovee, M.O. Leach, D. Leibfritz and J.D. de Certaines, Absolute metabolite quantification by in vivo NMR spectroscopy: I. Introduction, objectives and activities of a concerted action in biomedical research, Magn Reson Imaging 16 (1998), 1085-1092.
-
(1998)
Magn Reson Imaging
, vol.16
, pp. 1085-1092
-
-
Podo, F.1
Henriksen, O.2
Bovee, W.M.3
Leach, M.O.4
Leibfritz, D.5
De Certaines, J.D.6
-
37
-
-
0033369894
-
Current databases on biological variation: Pros, cons and progress
-
C. Ricos, V. Alvarez, F. Cava, J.V. Garcia-Lario, A. Hernandez, C.V. Jimenez, J. Minchinela, C. Perich and M. Simon, Current databases on biological variation: pros, cons and progress, Scand J Clin Lab Invest 59 (1999), 491-500.
-
(1999)
Scand J Clin Lab Invest
, vol.59
, pp. 491-500
-
-
Ricos, C.1
Alvarez, V.2
Cava, F.3
Garcia-Lario, J.V.4
Hernandez, A.5
Jimenez, C.V.6
Minchinela, J.7
Perich, C.8
Simon, M.9
-
38
-
-
0027507014
-
Erroneous laboratory results from hemolyzed, icteric, and lipemic specimens
-
K.W. Ryder and M.R. Glick, Erroneous laboratory results from hemolyzed, icteric, and lipemic specimens, Clin Chem 39 (1993), 175-176.
-
(1993)
Clin Chem
, vol.39
, pp. 175-176
-
-
Ryder, K.W.1
Glick, M.R.2
-
39
-
-
0040191763
-
Genomic medicine and the future of health care
-
C. Sander, Genomic medicine and the future of health care, Science 287 (2000), 1977-1988.
-
(2000)
Science
, vol.287
, pp. 1977-1988
-
-
Sander, C.1
-
40
-
-
0034962378
-
External Quality Assessment Schemes: Need for recognised requirements
-
L. Sciacovelli, S. Secchiero, L. Zardo and M. Plebani, External Quality Assessment Schemes: need for recognised requirements, Clin Chim Acta 309 (2001), 183-199.
-
(2001)
Clin Chim Acta
, vol.309
, pp. 183-199
-
-
Sciacovelli, L.1
Secchiero, S.2
Zardo, L.3
Plebani, M.4
-
41
-
-
0026336726
-
Analytical methods validation: Bioavailability, bioequivalence, and pharmacokinetic studies. Conference Report
-
V.P. Shah, K.K. Midha, S. Dighe, I.J. McGilveray, J.P. Skelly, A. Yacobi, T. Layloff, C.T. Viswanathan, C.E. Cook, R.D. McDowall, K.A. Pittman and S. Spector, Analytical methods validation: Bioavailability, bioequivalence, and pharmacokinetic studies. Conference Report, Europ J. Drug Metabolism and Pharmacokinetics 16 (1991), 249-255.
-
(1991)
Europ J Drug Metabolism and Pharmacokinetics
, vol.16
, pp. 249-255
-
-
Shah, V.P.1
Midha, K.K.2
Dighe, S.3
McGilveray, I.J.4
Skelly, J.P.5
Yacobi, A.6
Layloff, T.7
Viswanathan, C.T.8
Cook, C.E.9
McDowall, R.D.10
Pittman, K.A.11
Spector, S.12
-
42
-
-
0034469255
-
Bioanalytical method validation, a revisit with a decade of progress
-
V.P. Shah, K.K. Midha, J.W.A. Findlay, H.M. Hill, J.D. Hulse, I.J. McGilveray, G. McKay, K.J. Miller, R.N. Patnaik, M.L. Powell, A. Tonelli, C.T. Viswanathan and A. Yacobi, Bioanalytical method validation, a revisit with a decade of progress, Pharm Res 17 (2000), 1551-1557.
-
(2000)
Pharm Res
, vol.17
, pp. 1551-1557
-
-
Shah, V.P.1
Midha, K.K.2
Findlay, J.W.A.3
Hill, H.M.4
Hulse, J.D.5
McGilveray, I.J.6
McKay, G.7
Miller, K.J.8
Patnaik, R.N.9
Powell, M.L.10
Tonelli, A.11
Viswanathan, C.T.12
Yacobi, A.13
-
43
-
-
0035134454
-
Enabling large-scale pharmacogenetic studies by high-throughput mutation detection and genotyping technologies
-
M.M. Shi, Enabling large-scale pharmacogenetic studies by high-throughput mutation detection and genotyping technologies, Clin Chem 47 (2001), 164-172.
-
(2001)
Clin Chem
, vol.47
, pp. 164-172
-
-
Shi, M.M.1
-
44
-
-
0034957789
-
Accreditation of medical laboratories in The Netherlands
-
S. Slagter and J.G. Loeber, Accreditation of medical laboratories in The Netherlands, Clin Chim Acta 309 (2001), 155-161.
-
(2001)
Clin Chim Acta
, vol.309
, pp. 155-161
-
-
Slagter, S.1
Loeber, J.G.2
-
45
-
-
0026668416
-
Postprandial increase in serum creatinine in renal transplant recipients
-
G. Sterner, M. Wroblewski and U. Rosen, Postprandial increase in serum creatinine in renal transplant recipients, Transpl Int 5 (1992), 115-117.
-
(1992)
Transpl Int
, vol.5
, pp. 115-117
-
-
Sterner, G.1
Wroblewski, M.2
Rosen, U.3
-
46
-
-
0028068446
-
Effects of exercise intensity, duration, and time of day on fibrinolytic activity in physically active men
-
L.M. Szymanski and R.R. Pate, Effects of exercise intensity, duration, and time of day on fibrinolytic activity in physically active men, Med Sci Sports Exerc 26 (1994), 1102-1108.
-
(1994)
Med Sci Sports Exerc
, vol.26
, pp. 1102-1108
-
-
Szymanski, L.M.1
Pate, R.R.2
-
47
-
-
0026876109
-
Laboratory values in fit aging individuals - Sexagenarians through centenarians
-
N.W. Tietz, D.F. Shuey and D.R. Wekstein, Laboratory values in fit aging individuals - sexagenarians through centenarians, Clin Chem 38 (1992), 1167-1185.
-
(1992)
Clin Chem
, vol.38
, pp. 1167-1185
-
-
Tietz, N.W.1
Shuey, D.F.2
Wekstein, D.R.3
-
48
-
-
0034918708
-
Flow cytometry: An "old" tool for novel applications in medical genetics
-
N. Wedemeyer and T. Potter, Flow cytometry: an "old" tool for novel applications in medical genetics, Clin Genet 60 (2001), 1-8.
-
(2001)
Clin Genet
, vol.60
, pp. 1-8
-
-
Wedemeyer, N.1
Potter, T.2
-
49
-
-
0004263460
-
-
AACC Press, Washington, DC
-
J.O. Westgard, Basic Method Validation, AACC Press, Washington, DC, 1999, pp. 256.
-
(1999)
Basic Method Validation
, pp. 256
-
-
Westgard, J.O.1
-
50
-
-
0003838305
-
-
AACC Press, Washington, DC
-
D.S. Young, Effects of Drugs on Clinical Laboratory Tests, (Fourth ed.), AACC Press, Washington, DC, 1995, pp. 1462.
-
(1995)
Effects of Drugs on Clinical Laboratory Tests, (Fourth Ed.)
, pp. 1462
-
-
Young, D.S.1
|