메뉴 건너뛰기




Volumn 59, Issue 7, 1999, Pages 491-500

Current databases on biological variation: Pros, cons and progress

Author keywords

Analytical quality specifications; Bias; Biological variation; Database; Precision

Indexed keywords

ACCURACY; BIODIVERSITY; CLINICAL CHEMISTRY; CLINICAL LABORATORY; DATA ANALYSIS; DATA BASE; MEDICAL INFORMATION; PRIORITY JOURNAL; QUALITY CONTROL; REFERENCE VALUE; RELIABILITY; REVIEW;

EID: 0033369894     PISSN: 00365513     EISSN: None     Source Type: Journal    
DOI: 10.1080/00365519950185229     Document Type: Review
Times cited : (980)

References (9)
  • 1
    • 0008957463 scopus 로고
    • Evaluation of precision
    • Werner M, editor. Boca Raton: CRC Press
    • 1 Ross JW. Evaluation of precision. In: Werner M, editor. Handbook of clinical chemistry, Vol. 1. Boca Raton: CRC Press, 1982: 391-42.
    • (1982) Handbook of Clinical Chemistry , vol.1 , pp. 391-442
    • Ross, J.W.1
  • 2
    • 0023933212 scopus 로고
    • The application of theoretical goals based on biological variation data in proficiency testing
    • 2 Fraser CG. The application of theoretical goals based on biological variation data in proficiency testing. Arch Pathol Lab Med 1988; 112: 404-15.
    • (1988) Arch Pathol Lab Med , vol.112 , pp. 404-415
    • Fraser, C.G.1
  • 3
    • 0026666469 scopus 로고
    • Biological variation in clinical chemistry: An update
    • Collated data, 1988-1991
    • 3 Fraser CG. Biological variation in clinical chemistry: an update. Collated data, 1988-1991. Arch Pathol Lab Med 1992; 116: 916-23.
    • (1992) Arch Pathol Lab Med , vol.116 , pp. 916-923
    • Fraser, C.G.1
  • 5
    • 84943999500 scopus 로고
    • Proposed quality specifications for the imprecision and inaccuracy of analytical systems for clinical chemistry
    • 5 Fraser CG, Hyltoft Petersen P, Ricós C, Haeckel R. Proposed quality specifications for the imprecision and inaccuracy of analytical systems for clinical chemistry. Eur J Clin Chem Clin Biochem 1992; 30: 311-7.
    • (1992) Eur J Clin Chem Clin Biochem , vol.30 , pp. 311-317
    • Fraser, C.G.1    Hyltoft, P.P.2    Ricós, C.3    Haeckel, R.4
  • 7
    • 0008943804 scopus 로고    scopus 로고
    • 6 Ricós C, Alvarez V, Jiménez CV, Hernández A,Minchinela J, Perich C, Simón M. Transferabilityof results produced in the clinical laboratory. QuimClin (1996); 15: 442-4; 1997; 16: 218.
    • (1997) , vol.16 , pp. 218
  • 8
    • 0024342985 scopus 로고
    • Generation and application of data on biological variation in clinical chemistry
    • 7 Fraser CG, Harris EK. Generation and application of data on biological variation in clinical chemistry. Crit Rev Lab Sci 1989; 27: 409-37.
    • (1989) Crit Rev Lab Sci , vol.27 , pp. 409-437
    • Fraser, C.G.1    Harris, E.K.2
  • 9
    • 0023906492 scopus 로고
    • The "index of fiduciability" proposed for use in evaluation and comparison of methods
    • 8 Fraser CG, Browning MCK. The "Index of fiduciability" proposed for use in evaluation and comparison of methods. Clin Chem 1988; 34: 1356-7.
    • (1988) Clin Chem , vol.34 , pp. 1356-1357
    • Fraser, C.G.1    Browning, M.C.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.