-
1
-
-
0023153178
-
Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty
-
Sigwart U, Puel J, Mirkovitch V, Joffre F, Kappenberger L (1987) Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty. N Engl J Med 316: 701-706
-
(1987)
N. Engl. J. Med.
, vol.316
, pp. 701-706
-
-
Sigwart, U.1
Puel, J.2
Mirkovitch, V.3
Joffre, F.4
Kappenberger, L.5
-
2
-
-
0029841101
-
Intracoronary stenting. Form concept to custom
-
Ruygrok PN, Serruys PW (1996) Intracoronary stenting. Form concept to custom. Circulation 94: 882-890
-
(1996)
Circulation
, vol.94
, pp. 882-890
-
-
Ruygrok, P.N.1
Serruys, P.W.2
-
4
-
-
0027934377
-
A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease
-
Fischman DL, Leon MB, Baim DS et al. (1987) A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. N Engl J Med 331: 496-501
-
(1987)
N. Engl. J. Med.
, vol.331
, pp. 496-501
-
-
Fischman, D.L.1
Leon, M.B.2
Baim, D.S.3
-
5
-
-
0028123099
-
A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease
-
Serruys PW, de Jaegere P, Kiemeneij F et al. (1994) A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. N Engl J Med 331: 489-495
-
(1994)
N. Engl. J. Med.
, vol.331
, pp. 489-495
-
-
Serruys, P.W.1
de Jaegere, P.2
Kiemeneij, F.3
-
6
-
-
0042764635
-
Prospective evaluation of hemostatic predictors of subacute stent thrombosis after coronary Palmaz-Schatz stenting
-
Neumann FJ, Gawaz M, Ott I, May A, Mössmer G, Schömig A (1996) Prospective evaluation of hemostatic predictors of subacute stent thrombosis after coronary Palmaz-Schatz stenting. J Am Coll Cardiol 93: 412-422
-
(1996)
J. Am. Coll. Cardiol.
, vol.93
, pp. 412-422
-
-
Neumann, F.J.1
Gawaz, M.2
Ott, I.3
May, A.4
Mössmer, G.5
Schömig, A.6
-
8
-
-
9244251971
-
A randomized comparison of antiplatelet and anticoagulant therapy after the placement of coronary-artery stents
-
Shömig A, Neumann F-J, Kastrati A et al. (1996) A randomized comparison of antiplatelet and anticoagulant therapy after the placement of coronary-artery stents. N Engl J Med 345: 1084-1089
-
(1996)
N. Engl. J. Med.
, vol.345
, pp. 1084-1089
-
-
Shömig, A.1
Neumann, F.-J.2
Kastrati, A.3
-
9
-
-
13344293686
-
Three-year follow-up after implantation of metallic coronary artery stents
-
Kimura T, Yokoi H, Nakagawa Y et al. (1996) Three-year follow-up after implantation of metallic coronary artery stents. N Engl J Med 334: 561-566
-
(1996)
N. Engl. J. Med.
, vol.334
, pp. 561-566
-
-
Kimura, T.1
Yokoi, H.2
Nakagawa, Y.3
-
10
-
-
0027403101
-
A preliminary report comparing magnetic resonance coronary angiography with conventional angiography
-
Manning WJ, Li W, Edelman RR (1993) A preliminary report comparing magnetic resonance coronary angiography with conventional angiography. N Engl J Med 328: 828-832
-
(1993)
N. Engl. J. Med.
, vol.328
, pp. 828-832
-
-
Manning, W.J.1
Li, W.2
Edelman, R.R.3
-
11
-
-
0028036749
-
Two-dimensional coronary MR angiography: Analysis of initial clinical results
-
Duerinckx AJ, Urman MK (1994) Two-dimensional coronary MR angiography: analysis of initial clinical results. Radiology 193: 731-738
-
(1994)
Radiology
, vol.193
, pp. 731-738
-
-
Duerinckx, A.J.1
Urman, M.K.2
-
12
-
-
0030574295
-
Magnetic resonance angiography. Value for evaluating the patency of aortocoronary bypass
-
Ambrosi P, Gélisse R, Bruneau P et al. (1996) Magnetic resonance angiography. Value for evaluating the patency of aortocoronary bypass. Presse Med 25: 1873-1875
-
(1996)
Presse Med.
, vol.25
, pp. 1873-1875
-
-
Ambrosi, P.1
Gélisse, R.2
Bruneau, P.3
-
13
-
-
0030049876
-
Value of magnetic resonance imaging in assessing patency and function of coronary artery bypass grafts. An angiographically controlled study
-
Galjee MA, van Rossum AC, Doesburg T, van Eenige MJ, Visser CA (1996) Value of magnetic resonance imaging in assessing patency and function of coronary artery bypass grafts. An angiographically controlled study. Circulation 93: 660-666
-
(1996)
Circulation
, vol.93
, pp. 660-666
-
-
Galjee, M.A.1
van Rossum, A.C.2
Doesburg, T.3
van Eenige, M.J.4
Visser, C.A.5
-
14
-
-
0029851614
-
Coronary arteries: Three-dimensional MR imaging with retrospective respiratory gating
-
Li D, Kaushikkar S, Haacke EM et al. (1996) Coronary arteries: three-dimensional MR imaging with retrospective respiratory gating. Radiology 201: 857-863
-
(1996)
Radiology
, vol.201
, pp. 857-863
-
-
Li, D.1
Kaushikkar, S.2
Haacke, E.M.3
-
15
-
-
0029952524
-
Three dimensional respiratory-gated MR angiography of coronary arteries: Comparison with conventional coronary angiography
-
Post JC, van Rossum AC, Hofman MBM, Valk J, Visser CA (1996) Three dimensional respiratory-gated MR angiography of coronary arteries: comparison with conventional coronary angiography. AJR 166: 1399-1404
-
(1996)
AJR
, vol.166
, pp. 1399-1404
-
-
Post, J.C.1
van Rossum, A.C.2
Hofman, M.B.M.3
Valk, J.4
Visser, C.A.5
-
16
-
-
0030911958
-
Contrast-enhanced breath-hold MR angiography for evaluating patency of coronary artery bypass grafts
-
Vrachliotis TG, Bis KG, Aliabadi D, Shetty AN, Safian R, Simonetti O (1997) Contrast-enhanced breath-hold MR angiography for evaluating patency of coronary artery bypass grafts. AJR 168: 1073-1080
-
(1997)
AJR
, vol.168
, pp. 1073-1080
-
-
Vrachliotis, T.G.1
Bis, K.G.2
Aliabadi, D.3
Shetty, A.N.4
Safian, R.5
Simonetti, O.6
-
17
-
-
0031940113
-
Detection of coronary stenoses on source and projection images using three-dimensional MR angiography with retrospective respiratory gating: Preliminary experience
-
Woodard PK, Li D, Haacke EM et al. (1998) Detection of coronary stenoses on source and projection images using three-dimensional MR angiography with retrospective respiratory gating: preliminary experience. AJR 170: 883-888
-
(1998)
AJR
, vol.170
, pp. 883-888
-
-
Woodard, P.K.1
Li, D.2
Haacke, E.M.3
-
18
-
-
0034097058
-
Three-dimensional, navigator-echo MR coronary angiography in detecting stenoses of the major epicardial vessels, with conventional coronary angiography as the standard of reference
-
Sardanelli F, Molinari G, Zandrino F, Balbi M (2000) Three-dimensional, navigator-echo MR coronary angiography in detecting stenoses of the major epicardial vessels, with conventional coronary angiography as the standard of reference. Radiology 214: 808-814
-
(2000)
Radiology
, vol.214
, pp. 808-814
-
-
Sardanelli, F.1
Molinari, G.2
Zandrino, F.3
Balbi, M.4
-
19
-
-
0028230123
-
Major clinical events after coronary stenting. The multicenter registry of acute and elective Gianturco-Roubin stent placement
-
Sutton JM, Ellis SG, Roubin GS et al. (1994) Major clinical events after coronary stenting. The multicenter registry of acute and elective Gianturco-Roubin stent placement. Circulation 89: 1126-1137
-
(1994)
Circulation
, vol.89
, pp. 1126-1137
-
-
Sutton, J.M.1
Ellis, S.G.2
Roubin, G.S.3
-
20
-
-
0029857354
-
Non-invasive assessment of coronary Palmaz-Schatz stents by contrast enhanced electron beam computed tomography
-
Schmermund A, Haude M, Baumgart D et al. (1996) Non-invasive assessment of coronary Palmaz-Schatz stents by contrast enhanced electron beam computed tomography. Eur Heart J 17: 1546-1553
-
(1996)
Eur. Heart J.
, vol.17
, pp. 1546-1553
-
-
Schmermund, A.1
Haude, M.2
Baumgart, D.3
-
21
-
-
0032466808
-
Electron-beam CT in the noninvasive assessment of coronary stent patency
-
Pump H, Moehlenkamp S, Sehnert C et al. (1998) Electron-beam CT in the noninvasive assessment of coronary stent patency. Acad Radiol 5: 858-862
-
(1998)
Acad. Radiol.
, vol.5
, pp. 858-862
-
-
Pump, H.1
Moehlenkamp, S.2
Sehnert, C.3
-
22
-
-
0001377832
-
Multidetector-row CT for the noninvasive detection of high-grade coronary-artery stenoses an occlusions: First results
-
Kopp AF, Ohnesorge BM, Flohr T, Schroeder S (1999) Multidetector-row CT for the noninvasive detection of high-grade coronary-artery stenoses an occlusions: first results. Radiology 213(P):435
-
(1999)
Radiology
, vol.213
, Issue.P
, pp. 435
-
-
Kopp, A.F.1
Ohnesorge, B.M.2
Flohr, T.3
Schroeder, S.4
-
24
-
-
0027439822
-
Intravascular stents: Tissue-stent interactions and design considerations
-
Palmaz JC (1993) Intravascular stents: tissue-stent interactions and design considerations. AJR 160: 613-618
-
(1993)
AJR
, vol.160
, pp. 613-618
-
-
Palmaz, J.C.1
-
25
-
-
0023640674
-
Early and late results of intracoronary arterial stenting after coronary angioplasty in dogs
-
Roubin GS, Robinson KA, King SB III et al. (1987) Early and late results of intracoronary arterial stenting after coronary angioplasty in dogs. Circulation 76: 891-897
-
(1987)
Circulation
, vol.76
, pp. 891-897
-
-
Roubin, G.S.1
Robinson, K.A.2
King S.B. III3
-
26
-
-
0027379107
-
MR procedures and biomedical implants, materials, devices: 1993 update
-
Shellock FG, Morisoli S, Kanal E (1993) MR procedures and biomedical implants, materials, devices: 1993 update. Radiology 189: 587-599
-
(1993)
Radiology
, vol.189
, pp. 587-599
-
-
Shellock, F.G.1
Morisoli, S.2
Kanal, E.3
-
27
-
-
0028364655
-
Absence of movement of coronary stents after placement in a magnetic resonance imaging field
-
Scott NA, Pettigrew RI (1994) Absence of movement of coronary stents after placement in a magnetic resonance imaging field. Am J Cardiol 73: 900-901
-
(1994)
Am. J. Cardiol.
, vol.73
, pp. 900-901
-
-
Scott, N.A.1
Pettigrew, R.I.2
-
28
-
-
0029143654
-
Coronary MR angiography after coronary stent placement
-
Duerinckx AJ, Atkinson D, Hurwitz R, Mintorovitch J, Whitney W (1995) Coronary MR angiography after coronary stent placement. AJR 165: 662-664
-
(1995)
AJR
, vol.165
, pp. 662-664
-
-
Duerinckx, A.J.1
Atkinson, D.2
Hurwitz, R.3
Mintorovitch, J.4
Whitney, W.5
-
29
-
-
0031613391
-
Magnetic resonance angiography of coronary arteries: Assessment in patients with coronary stenosis and control after stent positioning
-
De Cobelli F, Guidetti D, Vanzulli A, Mellone R, Chierchia S, Del Maschio A (1998) Magnetic resonance angiography of coronary arteries: assessment in patients with coronary stenosis and control after stent positioning. Radiol Med 95: 54-61
-
(1998)
Radiol. Med.
, vol.95
, pp. 54-61
-
-
De Cobelli, F.1
Guidetti, D.2
Vanzulli, A.3
Mellone, R.4
Chierchia, S.5
Del Maschio, A.6
-
30
-
-
0033836904
-
Coronary arterial stents: Safety and artifacts during MR imaging
-
Hug J, Nagel E, Bornstedt A, Schnackenburg B, Oswald H, Fleck E (2000) Coronary arterial stents: safety and artifacts during MR imaging. Radiology 216: 781-787
-
(2000)
Radiology
, vol.216
, pp. 781-787
-
-
Hug, J.1
Nagel, E.2
Bornstedt, A.3
Schnackenburg, B.4
Oswald, H.5
Fleck, E.6
-
31
-
-
0003703555
-
Magnetic resonance. Bioeffects, safety, and patient management
-
Raven Press, New York
-
Shellock FG, Kanal E (1994) Magnetic resonance. Bioeffects, safety, and patient management. Raven Press, New York, pp 101-121
-
(1994)
, pp. 101-121
-
-
Shellock, F.G.1
Kanal, E.2
-
32
-
-
0021678581
-
MRI of postoperative patients with metallic implants
-
Mechlin M, Thickman D, Kressel HY et al. (1984) MRI of postoperative patients with metallic implants. AJR 143: 1281-1284
-
(1984)
AJR
, vol.143
, pp. 1281-1284
-
-
Mechlin, M.1
Thickman, D.2
Kressel, H.Y.3
-
33
-
-
0023832613
-
MR imaging artifacts, ferromagnetism, and magnetic torque of intravascular filters, stents, and coils
-
Teitelbaum GP, Bradley WG, Klein BD (1998) MR imaging artifacts, ferromagnetism, and magnetic torque of intravascular filters, stents, and coils. Radiology 166: 657-664
-
(1998)
Radiology
, vol.166
, pp. 657-664
-
-
Teitelbaum, G.P.1
Bradley, W.G.2
Klein, B.D.3
-
34
-
-
0031848849
-
Assessment of coronary artery patency after stent placement using magnetic resonance angiography
-
Duerinckx AJ, Atkinson D, Hurwitz (1998) Assessment of coronary artery patency after stent placement using magnetic resonance angiography. J Magn Reson Med 8: 896-902
-
(1998)
J. Magn. Reson. Med.
, vol.8
, pp. 896-902
-
-
Duerinckx, A.J.1
Atkinson, D.2
Hurwitz, R.3
-
35
-
-
0030024521
-
Coronary flow reserve: Noninvasive measurement in humans with breath-hold velocity-encoded cine MR imaging
-
Sakuma H, Blake LM, Amidon TM et al. (1996) Coronary flow reserve: noninvasive measurement in humans with breath-hold velocity-encoded cine MR imaging. Radiology 198: 745-750
-
(1996)
Radiology
, vol.198
, pp. 745-750
-
-
Sakuma, H.1
Blake, L.M.2
Amidon, T.M.3
-
36
-
-
0032709110
-
Error assessment due to coronary stents in flow-encoded phase contrast MR angiography: A phantom study
-
Lethimonnier F, Bouligand B, Thouveny F et al. (1999) Error assessment due to coronary stents in flow-encoded phase contrast MR angiography: a phantom study. J Magn Reson Imaging 10: 899-902
-
(1999)
J. Magn. Reson. Imaging
, vol.10
, pp. 899-902
-
-
Lethimonnier, F.1
Bouligand, B.2
Thouveny, F.3
-
37
-
-
0029688157
-
Two-dimensional coronary MRA: Limitations and artifacts
-
Duerinckx AJ, Atkinson D, Mintorovitch J, Simonetti OP, Urman MK (1996) Two-dimensional coronary MRA: limitations and artifacts. Eur Radiol 6: 312-325
-
(1996)
Eur. Radiol.
, vol.6
, pp. 312-325
-
-
Duerinckx, A.J.1
Atkinson, D.2
Mintorovitch, J.3
Simonetti, O.P.4
Urman, M.K.5
-
38
-
-
0027173863
-
A new macromolecule as a contrast agent for MR angiography: Preparation, properties, and animal studies
-
Bogdanov Jr AA, Weissleder R, Frank HW et al. (1993) A new macromolecule as a contrast agent for MR angiography: preparation, properties, and animal studies. Radiology 187: 701-706
-
(1993)
Radiology
, vol.187
, pp. 701-706
-
-
Bogdanov A.A., Jr.1
Weissleder, R.2
Frank, H.W.3
-
39
-
-
0030060015
-
Ultrasmall superparamagnetic iron oxide to enhance MRA of the renal and coronary arteries: Studies in human patients
-
Stillman AE, Wilke N, Li D, Haacke EM, McLachlan S (1996) Ultrasmall superparamagnetic iron oxide to enhance MRA of the renal and coronary arteries: studies in human patients. J Comput Assist Tomogr 20: 51-55
-
(1996)
J. Comput. Assist. Tomogr.
, vol.20
, pp. 51-55
-
-
Stillman, A.E.1
Wilke, N.2
Li, D.3
Haacke, E.M.4
McLachlan, S.5
-
41
-
-
0346847413
-
A completely new biocompatible metal alloy for construction of stents with minimal MR interference: Initial tests versus nitinol, tantalum, and stainless steel
-
Van Dijk LC, Van dijk BP, VanHolten J, Van Matheijssen NA, Pattynama PM (1999) A completely new biocompatible metal alloy for construction of stents with minimal MR interference: initial tests versus nitinol, tantalum, and stainless steel. Radiology 213(P):366
-
(1999)
Radiology
, vol.213
, Issue.P
, pp. 366
-
-
Van Dijk, L.C.1
Van dijk, B.P.2
VanHolten, J.3
Van Matheijssen, N.A.4
Pattynama, P.M.5
|