Volumn 8, Issue 4, 1998, Pages 896-902

Assessment of coronary artery patency after stent placement using magnetic resonance angiography

Author keywords

Cardiac MRI; Coronary stent; Coronary vessel, MR; MR Angiography

Indexed keywords

ADULT; AGED; ANGIOCARDIOGRAPHY; ARTICLE; CLINICAL ARTICLE; CORONARY ARTERY DISEASE; FEMALE; GRAFT PATENCY; HUMAN; LEFT ANTERIOR DESCENDING CORONARY ARTERY; MAGNETIC RESONANCE ANGIOGRAPHY; MALE; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; RIGHT CORONARY ARTERY; SAPHENOUS VEIN GRAFT; STENT; TRANSLUMINAL CORONARY ANGIOPLASTY;

EID: 0031848849     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/jmri.1880080420     Document Type: Article
Times cited : (28)

References (46)
  • 1
    • 0028087616 scopus 로고
    • Caveats about elective coronary stenting
    • Topol EJ. Caveats about elective coronary stenting (editorial). N Engl J Med 1994; 331(8):539-541.
    • (1994) N Engl J Med , vol.331 , Issue.8 , pp. 539-541
    • Topol, E.J.1
  • 2
    • 0028123099 scopus 로고
    • A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease
    • Benestent studygroup
    • Serruys PW, de Jaegere P, Kiemeneij F, et al. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease (Benestent study group). N Engl J Med 1994; 331:489-495.
    • (1994) N Engl J Med , vol.331 , pp. 489-495
    • Serruys, P.W.1    De Jaegere, P.2    Kiemeneij, F.3
  • 3
    • 0027934377 scopus 로고
    • A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease
    • Stent Restenosis Study-STRESS
    • Fishman DL, Leon MB, Baim DS, et al. A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease (Stent Restenosis Study-STRESS). N Engl J Med 1994; 331:496-501.
    • (1994) N Engl J Med , vol.331 , pp. 496-501
    • Fishman, D.L.1    Leon, M.B.2    Baim, D.S.3
  • 4
    • 13344293686 scopus 로고    scopus 로고
    • Three-year follow-up after implantation of metallic coronary-artery stents
    • Kimura T, Yokoi H, Nakagawa Y, et al. Three-year follow-up after implantation of metallic coronary-artery stents. N Engl J Med 1996; 334:561-566.
    • (1996) N Engl J Med , vol.334 , pp. 561-566
    • Kimura, T.1    Yokoi, H.2    Nakagawa, Y.3
  • 5
    • 0029113225 scopus 로고
    • Review: MR angiography of the coronary arteries
    • Duerinckx AJ. Review: MR angiography of the coronary arteries. Top Magn Reson Imaging 1995; 7(4):267-285.
    • (1995) Top Magn Reson Imaging , vol.7 , Issue.4 , pp. 267-285
    • Duerinckx, A.J.1
  • 6
    • 0029974482 scopus 로고    scopus 로고
    • Angiography
    • Boxt LM, guest ed. MRI Clinics of North America. Philadelphia, PA: WB Saunders Co
    • Duerinckx AJ. Coronary MR angiography. In: Boxt LM, guest ed. Cardiac MR imaging. MRI Clinics of North America. Philadelphia, PA: WB Saunders Co, 1996; 4 (2):361-418.
    • (1996) Cardiac MR Imaging , vol.4 , Issue.2 , pp. 361-418
    • Duerinckx, A.J.1    Coronary, M.R.2
  • 7
    • 0030797368 scopus 로고    scopus 로고
    • MRI of coronary arteries
    • Duerinckx AJ. MRI of coronary arteries. Int J Card Imaging 1997; 13(3):191-197.
    • (1997) Int J Card Imaging , vol.13 , Issue.3 , pp. 191-197
    • Duerinckx, A.J.1
  • 8
    • 0025961482 scopus 로고
    • Cineangiography of the heart in a single breathhold with a segmented TurboFLASH sequence
    • Atkinson D, Edelman R. Cineangiography of the heart in a single breathhold with a segmented TurboFLASH sequence. Radiology 1991; 178:359-362.
    • (1991) Radiology , vol.178 , pp. 359-362
    • Atkinson, D.1    Edelman, R.2
  • 9
    • 0026316572 scopus 로고
    • Coronary arteries: Breath-hold MR angiography
    • Edelman R, Manning W, Burstein D, Paulin S. Coronary arteries: breath-hold MR angiography. Radiology 1991; 181(3): 641-643.
    • (1991) Radiology , vol.181 , Issue.3 , pp. 641-643
    • Edelman, R.1    Manning, W.2    Burstein, D.3    Paulin, S.4
  • 10
    • 0027395731 scopus 로고
    • Fat-suppressed breath-hold magnetic resonance coronary angiography
    • Manning WJ, Li W, Boyle NG, Edelman RE. Fat-suppressed breath-hold magnetic resonance coronary angiography. Circulation 1993; 87:94-104.
    • (1993) Circulation , vol.87 , pp. 94-104
    • Manning, W.J.1    Li, W.2    Boyle, N.G.3    Edelman, R.E.4
  • 11
    • 0027670756 scopus 로고
    • Magnetic resonance coronary angiography
    • Manning W, Edelman R. Magnetic resonance coronary angiography. Magn Reson Q 1993; 9(3):131-151.
    • (1993) Magn Reson Q , vol.9 , Issue.3 , pp. 131-151
    • Manning, W.1    Edelman, R.2
  • 14
    • 0029303953 scopus 로고
    • Anomalous origin of the left coronary artery: Diagnosis by coronary MR angiography (Case Report)
    • Duerinckx AJ, Bogaert J, Jiang H, Lewis BS. Anomalous origin of the left coronary artery: diagnosis by coronary MR angiography (Case Report). Am J Roentgenol 1995; 164:1095-1097.
    • (1995) Am J Roentgenol , vol.164 , pp. 1095-1097
    • Duerinckx, A.J.1    Bogaert, J.2    Jiang, H.3    Lewis, B.S.4
  • 15
    • 0029089949 scopus 로고
    • Improved definition of anomalous left coronary artery by magnetic resonance coronary angiography
    • Manning WJ, Li W, Cohen SI, Johnson RG, Edelman RR. Improved definition of anomalous left coronary artery by magnetic resonance coronary angiography. Am Heart J 1995; 130(3 pt 1):615-617.
    • (1995) Am Heart J , vol.130 , Issue.3 PT 1 , pp. 615-617
    • Manning, W.J.1    Li, W.2    Cohen, S.I.3    Johnson, R.G.4    Edelman, R.R.5
  • 16
    • 0028866518 scopus 로고
    • Magnetic resonance angiography of anomalous coronary arteries: A new gold standard for delineating the proximal course?
    • Post JC, van Rossum AC, Bronzwaer JGF, et al. Magnetic resonance angiography of anomalous coronary arteries: a new gold standard for delineating the proximal course? Circulation 1995; 92:3163-3171.
    • (1995) Circulation , vol.92 , pp. 3163-3171
    • Post, J.C.1    Van Rossum, A.C.2    Bronzwaer, J.G.F.3
  • 17
    • 0028791286 scopus 로고
    • Identification of anomalous coronary arteries and their anatomic course by magnetic resonance coronary angiography
    • McConnell MV, Ganz P, Selwyn AP, Li W, Edelman RR, Manning WJ. Identification of anomalous coronary arteries and their anatomic course by magnetic resonance coronary angiography. Circulation 1995; 92:3158-3162.
    • (1995) Circulation , vol.92 , pp. 3158-3162
    • McConnell, M.V.1    Ganz, P.2    Selwyn, A.P.3    Li, W.4    Edelman, R.R.5    Manning, W.J.6
  • 18
    • 0345415803 scopus 로고
    • Coronary artery graft disease: Diagnosis of graft failure by magnetic resonance imaging
    • Lüscher TF, Turina M, Braunwald E, eds. Berlin: Springer-Verlag
    • Buser PT, Higgins CB. Coronary artery graft disease: diagnosis of graft failure by magnetic resonance imaging. In: Lüscher TF, Turina M, Braunwald E, eds. Coronary artery graft disease: mechanisms and prevention. Berlin: Springer-Verlag, 1994; 99-112.
    • (1994) Coronary Artery Graft Disease: Mechanisms and Prevention , pp. 99-112
    • Buser, P.T.1    Higgins, C.B.2
  • 19
    • 0027403101 scopus 로고
    • A preliminary report comparing magnetic resonance coronary angiography with conventional angiography
    • Manning WJ, Li W, Edelman RR. A preliminary report comparing magnetic resonance coronary angiography with conventional angiography. N Engl J Med 1993; 328:828-832.
    • (1993) N Engl J Med , vol.328 , pp. 828-832
    • Manning, W.J.1    Li, W.2    Edelman, R.R.3
  • 20
    • 0028036749 scopus 로고
    • Two-dimensional coronary MR angiography: Analysis of initial clinical results
    • Duerinckx AJ, Urman M. Two-dimensional coronary MR angiography: analysis of initial clinical results. Radiology 1994; 193:731-738.
    • (1994) Radiology , vol.193 , pp. 731-738
    • Duerinckx, A.J.1    Urman, M.2
  • 21
    • 0029351385 scopus 로고
    • Clinical application of magnetic resonance angiography for coronary arteries: Correlation with conventional angiography and evaluation of imaging time
    • Nitatori T, Hanaoka H, Yoshino A, Tominaga M, et al. Clinical application of magnetic resonance angiography for coronary arteries: correlation with conventional angiography and evaluation of imaging time. Nippon Acta Radiol 1995; 55:670-676.
    • (1995) Nippon Acta Radiol , vol.55 , pp. 670-676
    • Nitatori, T.1    Hanaoka, H.2    Yoshino, A.3    Tominaga, M.4
  • 22
  • 23
    • 0029855777 scopus 로고    scopus 로고
    • Magnetic resonance coronary angiography in heart transplant recipients
    • Mohiaddin RH, Bogren HG, Lazim F, et al. Magnetic resonance coronary angiography in heart transplant recipients. Coron Artery Dis 1996; 7(8):591-597.
    • (1996) Coron Artery Dis , vol.7 , Issue.8 , pp. 591-597
    • Mohiaddin, R.H.1    Bogren, H.G.2    Lazim, F.3
  • 24
    • 0031056691 scopus 로고    scopus 로고
    • Clinical utility of two-dimensional magnetic resonance angiography in detecting coronary artery disease
    • Post JC, van Rossum AC, Hofman MB, de Cock CC, Valk J, Visser CA. Clinical utility of two-dimensional magnetic resonance angiography in detecting coronary artery disease. Eur Heart J 1997; 18(3):426-433.
    • (1997) Eur Heart J , vol.18 , Issue.3 , pp. 426-433
    • Post, J.C.1    Van Rossum, A.C.2    Hofman, M.B.3    De Cock, C.C.4    Valk, J.5    Visser, C.A.6
  • 26
    • 0028962053 scopus 로고
    • Noninvasive determination of infarct artery patency by cine magnetic resonance angiography
    • Hundley WG, Clarke GD, Landau C, et al. Noninvasive determination of infarct artery patency by cine magnetic resonance angiography. Circulation 1995; 91:1347-1353.
    • (1995) Circulation , vol.91 , pp. 1347-1353
    • Hundley, W.G.1    Clarke, G.D.2    Landau, C.3
  • 27
    • 0029878647 scopus 로고    scopus 로고
    • Assessment of flow in the right human coronary artery by magnetic resonance phase contrast velocity measurements: Effects of cardiac and respiratory motion
    • Hofman MBM, van Rossum AC, Sprenger M, Westerhof N. Assessment of flow in the right human coronary artery by magnetic resonance phase contrast velocity measurements: effects of cardiac and respiratory motion. Magn Reson Med 1996; 35:521-531.
    • (1996) Magn Reson Med , vol.35 , pp. 521-531
    • Hofman, M.B.M.1    Van Rossum, A.C.2    Sprenger, M.3    Westerhof, N.4
  • 28
    • 0030024521 scopus 로고    scopus 로고
    • Coronary flow reserve: Noninvasive measurement in humans with breath-hold velocity-encoded cine MR imaging
    • Sakuma H, Blake LM, Amidon TM, et al. Coronary flow reserve: noninvasive measurement in humans with breath-hold velocity-encoded cine MR imaging. Radiology 1996; 198:745-750.
    • (1996) Radiology , vol.198 , pp. 745-750
    • Sakuma, H.1    Blake, L.M.2    Amidon, T.M.3
  • 29
    • 9244244132 scopus 로고    scopus 로고
    • Assessment of coronary arterial flow and flow reserve in humans with magnetic resonance imaging
    • Hundley WG, Lange RA, Clarke GD, Meshack BM, Payne J, Landau C, et al. Assessment of coronary arterial flow and flow reserve in humans with magnetic resonance imaging. Circulation 1996; 93:1502-1508.
    • (1996) Circulation , vol.93 , pp. 1502-1508
    • Hundley, W.G.1    Lange, R.A.2    Clarke, G.D.3    Meshack, B.M.4    Payne, J.5    Landau, C.6
  • 30
    • 0027394275 scopus 로고
    • Thrombosis of a flexible coil coronary stent: Frequency, predictors and clinical outcome
    • Nath FC, Muller DW, Ellis SG, et al. Thrombosis of a flexible coil coronary stent: frequency, predictors and clinical outcome. J Am Coll Cardiol 1993; 21(3):622-627.
    • (1993) J Am Coll Cardiol , vol.21 , Issue.3 , pp. 622-627
    • Nath, F.C.1    Muller, D.W.2    Ellis, S.G.3
  • 31
    • 0030042142 scopus 로고    scopus 로고
    • Coronary Palmaz-Schatz stent implantation in acute myocardial infarction
    • Neumann FJ, Walter H, Richardt G, Schmitt C, Schomig A. Coronary Palmaz-Schatz stent implantation in acute myocardial infarction. Heart 1996; 75(2):121-126.
    • (1996) Heart , vol.75 , Issue.2 , pp. 121-126
    • Neumann, F.J.1    Walter, H.2    Richardt, G.3    Schmitt, C.4    Schomig, A.5
  • 32
    • 0028812257 scopus 로고
    • Detection of Palmaz-Schatz stent by ultrafast CT
    • Yamaoka O, Ikeno K, Fujioka H, et al. Detection of Palmaz-Schatz stent by ultrafast CT. J Comput Assist Tomogr 1995; 19(1):128-130.
    • (1995) J Comput Assist Tomogr , vol.19 , Issue.1 , pp. 128-130
    • Yamaoka, O.1    Ikeno, K.2    Fujioka, H.3
  • 33
    • 0027358858 scopus 로고
    • Ultrafast computed tomographic scanning to assess patency of coronary artery stents in bypass grafts
    • Nyman MA, Schwartz RS, Breen JF, Garratt KN, Holmes DR. Ultrafast computed tomographic scanning to assess patency of coronary artery stents in bypass grafts. Mayo Clin Proc 1993; 68:1021-1023.
    • (1993) Mayo Clin Proc , vol.68 , pp. 1021-1023
    • Nyman, M.A.1    Schwartz, R.S.2    Breen, J.F.3    Garratt, K.N.4    Holmes, D.R.5
  • 34
    • 0028824215 scopus 로고
    • Noninvasive evaluation of the patency of coronary vessel stents using electron beam tomography segment images with administration of contrast media
    • Schmermund A, Haude M, Sehnert C, et al. [Noninvasive evaluation of the patency of coronary vessel stents using electron beam tomography segment images with administration of contrast media]. Z Kardiol 1995; 84(11):892-897.
    • (1995) Z Kardiol , vol.84 , Issue.11 , pp. 892-897
    • Schmermund, A.1    Haude, M.2    Sehnert, C.3
  • 35
    • 0029857354 scopus 로고    scopus 로고
    • Non-invasive assessment of coronary Palmaz-Schatz stents by contrast enhanced electron beam computed tomography
    • Schmermund A, Haude M, Baumgart D, et al. Non-invasive assessment of coronary Palmaz-Schatz stents by contrast enhanced electron beam computed tomography. Eur Heart J 1996; 17(10):1546-1553.
    • (1996) Eur Heart J , vol.17 , Issue.10 , pp. 1546-1553
    • Schmermund, A.1    Haude, M.2    Baumgart, D.3
  • 36
    • 0028364655 scopus 로고
    • Absence of movement of coronary stents after placement in a magnetic resonance imaging field
    • Scott NA, Pettigrew RI. Absence of movement of coronary stents after placement in a magnetic resonance imaging field. Am J Cardiol 1994; 73:900-901.
    • (1994) Am J Cardiol , vol.73 , pp. 900-901
    • Scott, N.A.1    Pettigrew, R.I.2
  • 37
    • 0344984551 scopus 로고
    • Bail-out stenting following percutaneous transluminal coronary angioplasty
    • Boston-Scientific-Corporation, Liermann D, ed. Morin Heights, Canada: Polyscience Publications, Inc.
    • Reifart N, Massa T, Langer A, et al. Bail-out stenting following percutaneous transluminal coronary angioplasty. In: Boston-Scientific-Corporation, Liermann D, ed. Stents: state of the art and future developments. Morin Heights, Canada: Polyscience Publications, Inc., 1995; 93-99.
    • (1995) Stents: State of the Art and Future Developments , pp. 93-99
    • Reifart, N.1    Massa, T.2    Langer, A.3
  • 38
    • 0344984550 scopus 로고
    • The future of cardiologic stents
    • Boston-Scientific-Corporation, Liermann D, ed. Morin Heights, Canada: Polyscience Publications, Inc.
    • Labinaz M, Phillips R, Stack RS, Zidar JP, Brott B. The future of cardiologic stents. In: Boston-Scientific-Corporation, Liermann D, ed. Stents: state of the art and future developments. Morin Heights, Canada: Polyscience Publications, Inc., 1995; 394-399.
    • (1995) Stents: State of the Art and Future Developments , pp. 394-399
    • Labinaz, M.1    Phillips, R.2    Stack, R.S.3    Zidar, J.P.4    Brott, B.5
  • 39
    • 0028817597 scopus 로고
    • Localization of a misplaced coronary artery stent by magnetic resonance imaging
    • Mohiaddin RH, Roberts RH, Underwood R, Rothman M. Localization of a misplaced coronary artery stent by magnetic resonance imaging. Clin Cardiol 1995; 18(3):175-177.
    • (1995) Clin Cardiol , vol.18 , Issue.3 , pp. 175-177
    • Mohiaddin, R.H.1    Roberts, R.H.2    Underwood, R.3    Rothman, M.4
  • 40
    • 0344553561 scopus 로고
    • Magnetic resonance examination of implanted endovascular prostheses in vessels: Initial results
    • Boston-Scientific-Corporation, Liermann D, ed. Morin Heights, Canada: Polyscience Publications, Inc.
    • Liermann D, Berkefeld J. Magnetic resonance examination of implanted endovascular prostheses in vessels: initial results. In: Boston-Scientific-Corporation, Liermann D, ed. Stents: state of the art and future developments. Morin Heights, Canada: Polyscience Publications, Inc., 1995; 386-393.
    • (1995) Stents: State of the Art and Future Developments , pp. 386-393
    • Liermann, D.1    Berkefeld, J.2
  • 43
    • 0024807123 scopus 로고
    • Noninvasive determination of coronary artery bypass graft patency by cine magnetic resonance imaging
    • Aurigemma G, Reichek N, Axel L, Schiebler M, Harris C, Kressel H. Noninvasive determination of coronary artery bypass graft patency by cine magnetic resonance imaging. Circulation 1989; 80:1595-1602.
    • (1989) Circulation , vol.80 , pp. 1595-1602
    • Aurigemma, G.1    Reichek, N.2    Axel, L.3    Schiebler, M.4    Harris, C.5    Kressel, H.6
  • 45
    • 0026734837 scopus 로고
    • Identification of coronary artery bypass grafts: Reliability of MRI in clinical practice
    • DiRenzi P, Fedele F, DiCesare E, et al. Identification of coronary artery bypass grafts: reliability of MRI in clinical practice. Int J Card Imaging. 1992; 8:85-94.
    • (1992) Int J Card Imaging , vol.8 , pp. 85-94
    • DiRenzi, P.1    Fedele, F.2    Dicesare, E.3
  • 46
    • 0023252971 scopus 로고
    • Coronary artery bypass graft patency: Noninvasive evaluation with MR imaging
    • White R, Caputo G, Mark A, Modin G, Higgins C. Coronary artery bypass graft patency: noninvasive evaluation with MR imaging. Radiology 1987; 164(3):681-686.
    • (1987) Radiology , vol.164 , Issue.3 , pp. 681-686
    • White, R.1    Caputo, G.2    Mark, A.3    Modin, G.4    Higgins, C.5