메뉴 건너뛰기




Volumn 29, Issue 3, 2002, Pages 167-174

Artificial oxygen carriers - A critical analysis

Author keywords

Blood substitutes; Hemoglobin solutions; Nitric oxide scavenger; Oxygen carrier; Perfluorocarbons

Indexed keywords

DEXAMETHASONE; DIASPIRIN CROSSLINKED HEMOGLOBIN; ENDOTOXIN; FLUOROCARBON; FLUOSOL DA; HEMOGLOBIN; HEMOGLOBIN DERIVATIVE; NITRIC OXIDE DONOR; PERFLUORODECALIN; PERFLUOROOCTYL BROMIDE; PHOSPHATIDYLCHOLINE; POLOXAMER; POLYMERIZED HEMOGLOBIN; RECOMBINANT HEMOGLOBIN; UNCLASSIFIED DRUG; VTR PHP;

EID: 0036067078     PISSN: 14245485     EISSN: None     Source Type: Journal    
DOI: 10.1159/000064237     Document Type: Conference Paper
Times cited : (5)

References (68)
  • 1
    • 0035912180 scopus 로고    scopus 로고
    • Blood product from cattle wins approval for use in humans
    • (2001) Nature , vol.410 , pp. 855
    • Lok, C.1
  • 5
    • 0002295399 scopus 로고
    • Perfluorochemical emulsions as blood substitutes: Clinical data and new applications
    • Tsuchida E (ed). Chicester, Wiley and Sons
    • (1995) Artificial Red Cells , pp. 199-226
    • Ohyanagi, H.1
  • 6
    • 0028330954 scopus 로고
    • Phagocytosis of colloidal carbon after administration of perfluorochemicals of first and second generation
    • (1994) Adv Exp Med Biol , vol.345 , pp. 221-226
    • Jager, L.J.1    Lutz, J.2
  • 20
    • 0032040264 scopus 로고    scopus 로고
    • Clinical experience with AF0150 (Imagent US), a new ultrasound contrast agent
    • (1998) Acad Radiol , vol.5 , Issue.SUPPL. 1
    • Pelura, T.J.1
  • 29
    • 0035008248 scopus 로고    scopus 로고
    • Safety and efficacy of o-raffinose cross-linked human hemoglobin (Hemolink) in cardiac surgery
    • (2001) Can J Anaesth , vol.48
    • Cheng, D.C.1
  • 47
    • 0031257769 scopus 로고    scopus 로고
    • Interactions of recombinant hemoglobin (rHb1.1) and endotoxin in vivo: Effects on systemic tumor necrosis factor and interleukin-6 levels in lethal and sublethal murine models of endotoxemia
    • (1997) J Lab Clin Med , vol.130 , pp. 427-435
    • Zuckerman, S.H.1    Evans, G.F.2    Bryan, N.3
  • 51
    • 0033624586 scopus 로고    scopus 로고
    • alphaalpha-crosslinked hemoglobin: Was failure predicted by preclinical testing?
    • (2000) Vox Sang , vol.79 , pp. 1-20
    • Winslow, R.M.1
  • 57
    • 0032869183 scopus 로고    scopus 로고
    • Modified hemoglobins produce venular interendothelial gaps and albumin leakage in the rat mesentery
    • (1999) Am J Physiol , vol.277
    • Baldwin, A.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.