-
1
-
-
84979136206
-
Blood substitutes
-
Amberson WR: Blood substitutes. Biol Rev 12:48, 1937
-
(1937)
Biol Rev
, vol.12
, pp. 48
-
-
Amberson, W.R.1
-
2
-
-
0025909084
-
Three li'l pigs and the hunt for blood substitutes
-
Moffat AS: Three li'l pigs and the hunt for blood substitutes. Science 253:32, 1991
-
(1991)
Science
, vol.253
, pp. 32
-
-
Moffat, A.S.1
-
3
-
-
0027358190
-
Production of human hemoglobin in transgenic swine: An approach to a blood substitute
-
O'Donnell JK, Martin MJ, Logan JS, Kumar R: Production of human hemoglobin in transgenic swine: An approach to a blood substitute. Cancer Detect Prev 17:307, 1993
-
(1993)
Cancer Detect Prev
, vol.17
, pp. 307
-
-
O'Donnell, J.K.1
Martin, M.J.2
Logan, J.S.3
Kumar, R.4
-
4
-
-
0024448557
-
Equilibrium oxygen binding to human hemoglobin crosslinked between the α chains by bis(3,5-dibromosalicyl) fumarate
-
Vandegriff KD, Medina F, Marini M, Winslow RM: Equilibrium oxygen binding to human hemoglobin crosslinked between the α chains by bis(3,5-dibromosalicyl) fumarate. J Biol Chem 264:17824, 1989
-
(1989)
J Biol Chem
, vol.264
, pp. 17824
-
-
Vandegriff, K.D.1
Medina, F.2
Marini, M.3
Winslow, R.M.4
-
5
-
-
0027145583
-
Production of modified crosslinked cell-free hemoglobin for human use: The role of quantitative determination of endotoxin contamination
-
Roth RI, Levin J, Chapman KW, Scmeizl M, Rickles FR: Production of modified crosslinked cell-free hemoglobin for human use: The role of quantitative determination of endotoxin contamination. Transfusion 33:919, 1993
-
(1993)
Transfusion
, vol.33
, pp. 919
-
-
Roth, R.I.1
Levin, J.2
Chapman, K.W.3
Scmeizl, M.4
Rickles, F.R.5
-
6
-
-
0023024415
-
Isolation and characterization of a new hemoglobin derivative crosslinked between the α chains
-
Chatterjee R, Welty EV, Walder RY, Pruitt ST, Rogers PH, Arnone A, Walders JA: Isolation and characterization of a new hemoglobin derivative crosslinked between the α chains. J Biol Chem 261:9929, 1986
-
(1986)
J Biol Chem
, vol.261
, pp. 9929
-
-
Chatterjee, R.1
Welty, E.V.2
Walder, R.Y.3
Pruitt, S.T.4
Rogers, P.H.5
Arnone, A.6
Walders, J.A.7
-
7
-
-
0023428522
-
HbXL99a, a hemoglobin derivative that is crosslinked between the α subunits is useful as a blood substitute
-
Snyder SR, Welty EV, Walder RY, Williams LA, Walder JA: HbXL99a, a hemoglobin derivative that is crosslinked between the α subunits is useful as a blood substitute. Proc Natl Acad Sci USA 84:7280, 1987
-
(1987)
Proc Natl Acad Sci USA
, vol.84
, pp. 7280
-
-
Snyder, S.R.1
Welty, E.V.2
Walder, R.Y.3
Williams, L.A.4
Walder, J.A.5
-
8
-
-
0005356260
-
Preclinical data and clinical trial with diaspirin crosslinked hemoglobin
-
Tsuchida E (ed): New York, NY, Wiley
-
Farmer MC, Pryzbelski RJ, McKenzie JE, Burhop KE: Preclinical data and clinical trial with diaspirin crosslinked hemoglobin, in Tsuchida E (ed): Artificial Red Cells. New York, NY, Wiley, 1995, p 177
-
(1995)
Artificial Red Cells
, pp. 177
-
-
Farmer, M.C.1
Pryzbelski, R.J.2
McKenzie, J.E.3
Burhop, K.E.4
-
9
-
-
0027340271
-
Focal cerebral ischemia in rats: Effect of hemodilution with α-α crosslinked hemoglobin on brain injury and edema
-
Cole DJ, Schell RM, Drummond JC, Pryzbelski RJ, Marcantonio S: Focal cerebral ischemia in rats: Effect of hemodilution with α-α crosslinked hemoglobin on brain injury and edema. Can J Neurol Sci 20:30, 1993
-
(1993)
Can J Neurol Sci
, vol.20
, pp. 30
-
-
Cole, D.J.1
Schell, R.M.2
Drummond, J.C.3
Pryzbelski, R.J.4
Marcantonio, S.5
-
10
-
-
0024693332
-
Immunogenicity of proteins administered to humans for therapeutic purposes
-
Konrad M: Immunogenicity of proteins administered to humans for therapeutic purposes. Trends Biotechnol 7:175, 1989
-
(1989)
Trends Biotechnol
, vol.7
, pp. 175
-
-
Konrad, M.1
-
11
-
-
0015993283
-
Hemoglobin II. Immunogenic properties of stroma versus stroma-free hemoglobin solution
-
Cochin A, Das Gupta TK, De Woskin, R, Moss, GS: Hemoglobin II. Immunogenic properties of stroma versus stroma-free hemoglobin solution. J Surg Oncol 4:19, 1974
-
(1974)
J Surg Oncol
, vol.4
, pp. 19
-
-
Cochin, A.1
Das Gupta, T.K.2
De Woskin, R.3
Moss, G.S.4
-
12
-
-
0026706548
-
Immunogenicity of diaspirin cross-linked human hemoglobin solutions
-
Estep TN, Gonder J, Bornstein I, Aono F: Immunogenicity of diaspirin cross-linked human hemoglobin solutions. Biomat Art Cells Immob Biotech 20:603, 1992
-
(1992)
Biomat Art Cells Immob Biotech
, vol.20
, pp. 603
-
-
Estep, T.N.1
Gonder, J.2
Bornstein, I.3
Aono, F.4
-
14
-
-
0027366806
-
The resonant mirror: A novel optical biosensor for direct sensing of biomolecular interactions. Part I: Principles of operation and associated instrumentation
-
Cush R, Cronin JM, Stewart WJ, Maule CH, Molloy J, Goddard NJ: The resonant mirror: A novel optical biosensor for direct sensing of biomolecular interactions. Part I: Principles of operation and associated instrumentation. Biosens Bioelectron 8:347, 1993
-
(1993)
Biosens Bioelectron
, vol.8
, pp. 347
-
-
Cush, R.1
Cronin, J.M.2
Stewart, W.J.3
Maule, C.H.4
Molloy, J.5
Goddard, N.J.6
-
15
-
-
0027489142
-
The resonant mirror: A novel optical biosensor for direct sensing of biomolecular interactions. Part II: Applications
-
Buckle BE, Davies RJ, Kinning T, Yeung D, Edwards PR, Pollard-Knight D, Lowe CR: The resonant mirror: A novel optical biosensor for direct sensing of biomolecular interactions. Part II: Applications. Biosens Bioelectron 8:355, 1993
-
(1993)
Biosens Bioelectron
, vol.8
, pp. 355
-
-
Buckle, B.E.1
Davies, R.J.2
Kinning, T.3
Yeung, D.4
Edwards, P.R.5
Pollard-Knight, D.6
Lowe, C.R.7
-
16
-
-
0029053975
-
Measurement of kinetic binding constants of a panel of anti-saporin antibodies using a resonant mirror biosensor
-
George AJT, French RR, Glennie MJ: Measurement of kinetic binding constants of a panel of anti-saporin antibodies using a resonant mirror biosensor. J Immunol Methods 183:51, 1995
-
(1995)
J Immunol Methods
, vol.183
, pp. 51
-
-
George, A.J.T.1
French, R.R.2
Glennie, M.J.3
-
17
-
-
0019169471
-
The communication of ELISA data from laboratory to clinician
-
de Savigny D, Voller A: The communication of ELISA data from laboratory to clinician. J Immunoassay 1:105, 1980
-
(1980)
J Immunoassay
, vol.1
, pp. 105
-
-
De Savigny, D.1
Voller, A.2
-
18
-
-
84920301945
-
Structural characterization of a hemoglobin based blood substitute: Diaspirin crosslinked hemoglobin (DCLHb™)
-
Patel MJ, Yu Z, Friso G, Lo-Tseng T, Webb EJ, Moore EG, Burlingame AL: Structural characterization of a hemoglobin based blood substitute: Diaspirin crosslinked hemoglobin (DCLHb™). Prot Sci 6:109, 1997 (suppl 1)
-
(1997)
Prot Sci
, vol.6
, Issue.1 SUPPL.
, pp. 109
-
-
Patel, M.J.1
Yu, Z.2
Friso, G.3
Lo-Tseng, T.4
Webb, E.J.5
Moore, E.G.6
Burlingame, A.L.7
-
19
-
-
24544440516
-
Characterization of diaspirin crosslinked hemoglobin (DCLHb™) by spectroscopic techniques
-
Shelbourn TE, Moore EG, Patel MJ: Characterization of diaspirin crosslinked hemoglobin (DCLHb™) by spectroscopic techniques. FASEB J 10:A1388, 1996
-
(1996)
FASEB J
, vol.10
-
-
Shelbourn, T.E.1
Moore, E.G.2
Patel, M.J.3
-
21
-
-
0029958436
-
Phase I study of the safety and pharmacologic effects of diaspirin crosslinked hemoglobin solution
-
Pryzbelski RJ, Daily EK, Kisicki JC, Mattia-Goldberg C, Bounds MJ, Colburn WA: Phase I study of the safety and pharmacologic effects of diaspirin crosslinked hemoglobin solution. Crit Care Med 24:1993, 1996
-
(1996)
Crit Care Med
, vol.24
, pp. 1993
-
-
Pryzbelski, R.J.1
Daily, E.K.2
Kisicki, J.C.3
Mattia-Goldberg, C.4
Bounds, M.J.5
Colburn, W.A.6
|