메뉴 건너뛰기




Volumn 4702, Issue , 2002, Pages 212-221

Development of a directional sensitive pressure and shear sensor

Author keywords

Distributive mechanical sensor; Fiber optic sensor; Macro bend sensor; Pressure sensor; Shear sensor

Indexed keywords

ARRAYS; BENDING (DEFORMATION); COMPRESSION TESTING; ELASTOMERS; LOADS (FORCES); OPTICAL FIBERS; PRESSURE EFFECTS; PRESSURE MEASUREMENT; SENSITIVITY ANALYSIS; SHEAR STRESS;

EID: 0036028944     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.469910     Document Type: Conference Paper
Times cited : (7)

References (30)
  • 1
    • 0034648723 scopus 로고    scopus 로고
    • Foot ulcers
    • Sumpio, B.E., Foot ulcers. N Engl J Med, 2000. 343(11): p. 787-93.
    • (2000) N Engl J Med , vol.343 , Issue.11 , pp. 787-793
    • Sumpio, B.E.1
  • 2
    • 0002706936 scopus 로고    scopus 로고
    • The biomechanics of the boot in diabetes mellitus
    • J.H. Bokwer and M.A. Pfeifer, Editors: St. Louis
    • Cavanagh, P., J.S. Ulbrecht, and G.M. Capulo, "The biomechanics of the boot in diabetes mellitus," in The Diabetic Foot, J.H. Bokwer and M.A. Pfeifer, Editors. 2001: St. Louis. p. 125 - 196.
    • (2001) The Diabetic Foot , pp. 125-196
    • Cavanagh, P.1    Ulbrecht, J.S.2    Capulo, G.M.3
  • 3
    • 0020661209 scopus 로고
    • Dynamic foot pressure and other studies as diagnostic and management aids in diabetic neuropathy
    • Boulton, A.J., et al., "Dynamic foot pressure and other studies as diagnostic and management aids in diabetic neuropathy," Diabetes Care, 1983.6(1): p. 26-33.
    • (1983) Diabetes Care , vol.6 , Issue.1 , pp. 26-33
    • Boulton, A.J.1
  • 6
    • 0021894295 scopus 로고
    • The aetiology of diabetic neuropathic ulceration of the foot
    • Delbridge, L., et al., "The aetiology of diabetic neuropathic ulceration of the foot," Br J Surg, 1985. 72(1):p. 1-6.
    • (1985) Br J Surg , vol.72 , Issue.1 , pp. 1-6
    • Delbridge, L.1
  • 9
    • 0043139056 scopus 로고    scopus 로고
    • A Novel tactile sensor system for heavy-load applications based on an integrated capacitive pressure sensor
    • Paschen-U., Leineweber-M., Amelung-J., Schmidt-M. Zimmer-G., "A Novel tactile sensor system for heavy-load applications based on an integrated capacitive pressure sensor," Sensors and Actuators A 68, p. 294-8, 1998.
    • (1998) Sensors and Actuators A , vol.68 , pp. 294-298
    • Paschen, U.1    Leineweber, M.2    Amelung, J.3    Schmidt, M.4    Zimmer, G.5
  • 11
    • 0032520419 scopus 로고    scopus 로고
    • An arbitrarily distributed tactile piezoelectric sensor array
    • Pinh-Li, Yumei-Wen, "An arbitrarily distributed tactile piezoelectric sensor array," Sensors and Actuators A, 65, No.2-3, p. 141-6, 1998.
    • (1998) Sensors and Actuators A , vol.65 , Issue.2-3 , pp. 141-146
    • Pinh, L.1    Yumei, W.2
  • 21
    • 0001558496 scopus 로고
    • Use of piezoresistive materials in the measurement of displacement, force, and torque
    • W.P. Mason and R.N. Thurston, "use of Piezoresistive materials in the Measurement of Displacement, Force, and Torque," Journal of the Acoustical Society of America, Vol.29, No. 10, p. 1096-1101, 1957.
    • (1957) Journal of the Acoustical Society of America , vol.29 , Issue.10 , pp. 1096-1101
    • Mason, W.P.1    Thurston, R.N.2
  • 22
    • 0015588568 scopus 로고
    • An IC piezoresistive pressure sensor for biomedical instrumentation
    • S.K.D. Wise, J. Angell, "An IC Piezoresistive Pressure Sensor for Biomedical Instrumentation", IEEE Trans. On Biomedical Engineering, 20, No.2, p.101-109, 1973.
    • (1973) IEEE Trans. On Biomedical Engineering , vol.20 , Issue.2 , pp. 101-109
    • Wise, S.K.D.1    Angell, J.2
  • 24
    • 0005084814 scopus 로고    scopus 로고
    • PVDF and array transducers
    • R.A. Day, "PVDF and Array Transducers", Transducer 96 Workshop,.1 No. 9, 1996.
    • (1996) Transducer 96 Workshop , vol.1 , Issue.9
    • Day, R.A.1
  • 27
  • 28
    • 0002872111 scopus 로고
    • Plantar pressure in the diabetic foot
    • G.J. Sammarco, Editor, Lea & Febiger: Malvern, PA
    • Cavanagh, P.R. and J.S. Ulbrecht, Plantar pressure in the diabetic foot, in The Foot in Diabetes, G.J. Sammarco, Editor. 1991, Lea & Febiger: Malvern, PA. p. 54-69.
    • (1991) The Foot in Diabetes , pp. 54-69
    • Cavanagh, P.R.1    Ulbrecht, J.S.2
  • 29
    • 0000711845 scopus 로고
    • Effects of walking speed on plantar pressure patterns and hindfoot angular motion
    • Rosenbaum, D., et al., Effects of walking speed on plantar pressure patterns and hindfoot angular motion. Gait & Posture, 1994. 2: p. 191-197.
    • (1994) Gait & Posture , vol.2 , pp. 191-197
    • Rosenbaum, D.1
  • 30
    • 0036142848 scopus 로고    scopus 로고
    • Simultaneous measurement of plantar pressure and shear forces in diabetic individuals
    • Perry, J.E., J.O. Hall, and B.L. Davis, Simultaneous measurement of plantar pressure and shear forces in diabetic individuals. Gait Posture, 2002. 15(1): p. 101-7.
    • (2002) Gait Posture , vol.15 , Issue.1 , pp. 101-107
    • Perry, J.E.1    Hall, J.O.2    Davis, B.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.